diff options
author | pmikus <pmikus@cisco.com> | 2017-03-30 07:42:40 +0200 |
---|---|---|
committer | pmikus <pmikus@cisco.com> | 2017-03-30 09:37:46 +0200 |
commit | 974897e8bcff8f3baeadf09b87840f530d8f41c1 (patch) | |
tree | a53d9e15fca8c19783d89b7f0767356bad377e27 /tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot | |
parent | 81fc408c0dfcce0e093733810d80598abf25866a (diff) |
Fix: Naming of perf suites following conventions
Change-Id: I39c3b6b1555a165f2103068a5296d92e0210f221
Signed-off-by: pmikus <pmikus@cisco.com>
Diffstat (limited to 'tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot')
-rw-r--r-- | tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot | 257 |
1 files changed, 257 insertions, 0 deletions
diff --git a/tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot b/tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot new file mode 100644 index 0000000000..c80d6f901a --- /dev/null +++ b/tests/perf/40ge2p1xl710-eth-l2xcbase-ndrpdrdisc.robot @@ -0,0 +1,257 @@ +# Copyright (c) 2017 Cisco and/or its affiliates. +# Licensed under the Apache License, Version 2.0 (the "License"); +# you may not use this file except in compliance with the License. +# You may obtain a copy of the License at: +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, +# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. +# See the License for the specific language governing permissions and +# limitations under the License. + +*** Settings *** +| Resource | resources/libraries/robot/performance.robot +| Library | resources.libraries.python.InterfaceUtil +| Library | resources.libraries.python.NodePath +| ... +| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC +| ... | NIC_Intel-XL710 | ETH | L2XCFWD | BASE +| ... +| Suite Setup | 3-node Performance Suite Setup with DUT's NIC model +| ... | L2 | Intel-XL710 +| Suite Teardown | 3-node Performance Suite Teardown +| ... +| Test Setup | Performance test setup +| Test Teardown | Performance test teardown | ${min_rate}pps | ${framesize} +| ... | 3-node-xconnect +| ... +| Documentation | *RFC2544: Pkt throughput L2XC test cases* +| ... +| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology +| ... | with single links between nodes. +| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 cross connect. +| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross- +| ... | connect. DUT1 and DUT2 tested with 2p40GE NIC XL710 by Intel. +| ... | *[Ver] TG verification:* TG finds and reports throughput NDR (Non Drop +| ... | Rate) with zero packet loss tolerance or throughput PDR (Partial Drop +| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage +| ... | of packets transmitted. NDR and PDR are discovered for different +| ... | Ethernet L2 frame sizes using either binary search or linear search +| ... | algorithms with configured starting rate and final step that determines +| ... | throughput measurement resolution. Test packets are generated by TG on +| ... | links to DUTs. TG traffic profile contains two L3 flow-groups +| ... | (flow-group per direction, 253 flows per flow-group) with all packets +| ... | containing Ethernet header, IPv4 header with IP protocol=61 and static +| ... | payload. MAC addresses are matching MAC addresses of the TG node +| ... | interfaces. +| ... | *[Ref] Applicable standard specifications:* RFC2544. + +*** Variables *** +# XL710-DA2 bandwidth limit ~49Gbps/2=24.5Gbps +| ${s_24.5G} | ${24500000000} +# XL710-DA2 Mpps limit 37.5Mpps/2=18.75Mpps +| ${s_18.75Mpps} | ${18750000} + +*** Test Cases *** +| tc01-64B-1t1c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy core, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for 64 Byte frames +| | ... | using binary search start at 18.75Mpps rate, step 100kpps. +| | [Tags] | 1T1C | STHREAD | NDRDISC +| | ${framesize}= | Set Variable | 64 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Set Variable | ${s_18.75Mpps} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc03-1518B-1t1c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy core, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for 1518 Byte frames +| | ... | using binary search start at 24.5G rate, step 10kpps. +| | [Tags] | 1T1C | STHREAD | NDRDISC +| | ${framesize}= | Set Variable | 1518 +| | ${min_rate}= | Set Variable | ${10000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${framesize} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc07-64B-2t2c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy cores, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for 64 Byte frames +| | ... | using binary search start at 18.75Mpps rate, step 100kpps. +| | [Tags] | 2T2C | MTHREAD | NDRDISC +| | ${framesize}= | Set Variable | 64 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Set Variable | ${s_18.75Mpps} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc09-1518B-2t2c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy cores, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for 1518 Byte frames +| | ... | using binary search start at 24.5G rate, step 10kpps. +| | [Tags] | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH +| | ${framesize}= | Set Variable | 1518 +| | ${min_rate}= | Set Variable | ${10000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${framesize} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc13-64B-4t4c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy cores, \ +| | ... | 2 receive queues per NIC port. [Ver] Find NDR for 64 Byte frames +| | ... | using binary search start at 18.75Mpps rate, step 100kpps. +| | [Tags] | 4T4C | MTHREAD | NDRDISC +| | ${framesize}= | Set Variable | 64 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Set Variable | ${s_18.75Mpps} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc15-1518B-4t4c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy cores, \ +| | ... | 2 receive queues per NIC port. [Ver] Find NDR for 1518 Byte frames +| | ... | using binary search start at 24.5G rate, step 10kpps. +| | [Tags] | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH +| | ${framesize}= | Set Variable | 1518 +| | ${min_rate}= | Set Variable | ${10000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${framesize} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc19-IMIX-1t1c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy core, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for IMIX_v4_1 frame size +| | ... | using binary search start at 24.5G rate, step 100kpps. +| | ... | IMIX_v4_1 = (28x64B;16x570B;4x1518B) +| | [Tags] | 1T1C | STHREAD | NDRDISC +| | ${framesize}= | Set Variable | IMIX_v4_1 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${353.83333} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add all PCI devices to all DUTs +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc20-IMIX-2t2c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 thread, 2 phy core, \ +| | ... | 1 receive queue per NIC port. [Ver] Find NDR for IMIX_v4_1 frame size +| | ... | using binary search start at 24.5G rate, step 100kpps. +| | ... | IMIX_v4_1 = (28x64B;16x570B;4x1518B) +| | [Tags] | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH +| | ${framesize}= | Set Variable | IMIX_v4_1 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${353.83333} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo +| | And Add all PCI devices to all DUTs +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} + +| tc21-IMIX-4t4c-eth-l2xcbase-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 thread, 4 phy core, \ +| | ... | 2 receive queue per NIC port. [Ver] Find NDR for IMIX_v4_1 frame size +| | ... | using binary search start at 24.5G rate, step 100kpps. +| | ... | IMIX_v4_1 = (28x64B;16x570B;4x1518B) +| | [Tags] | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH +| | ${framesize}= | Set Variable | IMIX_v4_1 +| | ${min_rate}= | Set Variable | ${100000} +| | ${max_rate}= | Calculate pps | ${s_24.5G} | ${353.83333} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo +| | And Add all PCI devices to all DUTs +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | And L2 xconnect initialized in a 3-node circular topology +| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} +| | ... | ${binary_max} | 3-node-xconnect +| | ... | ${min_rate} | ${max_rate} +| | ... | ${threshold} |