-Overview
-========
-
-VPP performance test results are reported for a range of processors.
-For description of physical testbeds used for VPP performance tests
-please refer to :ref:`tested_physical_topologies`.
-
-.. _tested_logical_topologies:
-
-Logical Topologies
-------------------
-
-CSIT VPP performance tests are executed on physical testbeds described
-in :ref:`tested_physical_topologies`. Based on the packet path thru
-server SUTs, three distinct logical topology types are used for VPP DUT
-data plane testing:
-
-#. NIC-to-NIC switching topologies.
-#. VM service switching topologies.
-#. Container service switching topologies.
-
-NIC-to-NIC Switching
-~~~~~~~~~~~~~~~~~~~~
-
-The simplest logical topology for software data plane application like
-VPP is NIC-to-NIC switching. Tested topologies for 2-Node and 3-Node
-testbeds are shown in figures below.
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-2n-nic2nic}
- \label{fig:logical-2n-nic2nic}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-2n-nic2nic.svg
- :alt: logical-2n-nic2nic
- :align: center
-
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-3n-nic2nic}
- \label{fig:logical-3n-nic2nic}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-3n-nic2nic.svg
- :alt: logical-3n-nic2nic
- :align: center
-
-Server Systems Under Test (SUT) run VPP application in Linux user-mode
-as a Device Under Test (DUT). Server Traffic Generator (TG) runs T-Rex
-application. Physical connectivity between SUTs and TG is provided using
-different drivers and NIC models that need to be tested for performance
-(packet/bandwidth throughput and latency).
-
-From SUT and DUT perspectives, all performance tests involve forwarding
-packets between two (or more) physical Ethernet ports (10GE, 25GE, 40GE,
-100GE). In most cases both physical ports on SUT are located on the same
-NIC. The only exceptions are link bonding and 100GE tests. In the latter
-case only one port per NIC can be driven at linerate due to PCIe Gen3
-x16 slot bandwidth limiations. 100GE NICs are not supported in PCIe Gen3
-x8 slots.
-
-Note that reported VPP DUT performance results are specific to the SUTs
-tested. SUTs with other processors than the ones used in FD.io lab are
-likely to yield different results. A good rule of thumb, that can be
-applied to estimate VPP packet thoughput for NIC-to-NIC switching
-topology, is to expect the forwarding performance to be proportional to
-processor core frequency for the same processor architecture, assuming
-processor is the only limiting factor and all other SUT parameters are
-equivalent to FD.io CSIT environment.
-
-VM Service Switching
-~~~~~~~~~~~~~~~~~~~~
-
-VM service switching topology test cases require VPP DUT to communicate
-with Virtual Machines (VMs) over vhost-user virtual interfaces.
-
-Two types of VM service topologies are tested in |csit-release|:
-
-#. "Parallel" topology with packets flowing within SUT from NIC(s) via
- VPP DUT to VM, back to VPP DUT, then out thru NIC(s).
-
-#. "Chained" topology (a.k.a. "Snake") with packets flowing within SUT
- from NIC(s) via VPP DUT to VM, back to VPP DUT, then to the next VM,
- back to VPP DUT and so on and so forth until the last VM in a chain,
- then back to VPP DUT and out thru NIC(s).
-
-For each of the above topologies, VPP DUT is tested in a range of L2
-or IPv4/IPv6 configurations depending on the test suite. Sample VPP DUT
-"Chained" VM service topologies for 2-Node and 3-Node testbeds with each
-SUT running N of VM instances is shown in the figures below.
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-2n-vm-vhost}
- \label{fig:logical-2n-vm-vhost}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-2n-vm-vhost.svg
- :alt: logical-2n-vm-vhost
- :align: center
-
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-3n-vm-vhost}
- \label{fig:logical-3n-vm-vhost}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-3n-vm-vhost.svg
- :alt: logical-3n-vm-vhost
- :align: center
-
-In "Chained" VM topologies, packets are switched by VPP DUT multiple
-times: twice for a single VM, three times for two VMs, N+1 times for N
-VMs. Hence the external throughput rates measured by TG and listed in
-this report must be multiplied by N+1 to represent the actual VPP DUT
-aggregate packet forwarding rate.
-
-For "Parallel" service topology packets are always switched twice by VPP
-DUT per service chain.
-
-Note that reported VPP DUT performance results are specific to the SUTs
-tested. SUTs with other processor than the ones used in FD.io lab are
-likely to yield different results. Similarly to NIC-to-NIC switching
-topology, here one can also expect the forwarding performance to be
-proportional to processor core frequency for the same processor
-architecture, assuming processor is the only limiting factor. However
-due to much higher dependency on intensive memory operations in VM
-service chained topologies and sensitivity to Linux scheduler settings
-and behaviour, this estimation may not always yield good enough
-accuracy.
-
-Container Service Switching
-~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-Container service switching topology test cases require VPP DUT to
-communicate with Containers (Ctrs) over memif virtual interfaces.
-
-Three types of VM service topologies are tested in |csit-release|:
-
-#. "Parallel" topology with packets flowing within SUT from NIC(s) via
- VPP DUT to Container, back to VPP DUT, then out thru NIC(s).
-
-#. "Chained" topology (a.k.a. "Snake") with packets flowing within SUT
- from NIC(s) via VPP DUT to Container, back to VPP DUT, then to the
- next Container, back to VPP DUT and so on and so forth until the
- last Container in a chain, then back to VPP DUT and out thru NIC(s).
-
-#. "Horizontal" topology with packets flowing within SUT from NIC(s) via
- VPP DUT to Container, then via "horizontal" memif to the next
- Container, and so on and so forth until the last Container, then
- back to VPP DUT and out thru NIC(s).
-
-For each of the above topologies, VPP DUT is tested in a range of L2
-or IPv4/IPv6 configurations depending on the test suite. Sample VPP DUT
-"Chained" Container service topologies for 2-Node and 3-Node testbeds
-with each SUT running N of Container instances is shown in the figures
-below.
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-2n-container-memif}
- \label{fig:logical-2n-container-memif}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-2n-container-memif.svg
- :alt: logical-2n-container-memif
- :align: center
-
-
-.. only:: latex
-
- .. raw:: latex
-
- \begin{figure}[H]
- \centering
- \graphicspath{{../_tmp/src/vpp_performance_tests/}}
- \includegraphics[width=0.90\textwidth]{logical-3n-container-memif}
- \label{fig:logical-3n-container-memif}
- \end{figure}
-
-.. only:: html
-
- .. figure:: logical-3n-container-memif.svg
- :alt: logical-3n-container-memif
- :align: center
-
-In "Chained" Container topologies, packets are switched by VPP DUT
-multiple times: twice for a single Container, three times for two
-Containers, N+1 times for N Containers. Hence the external throughput
-rates measured by TG and listed in this report must be multiplied by N+1
-to represent the actual VPP DUT aggregate packet forwarding rate.
-
-For a "Parallel" and "Horizontal" service topologies packets are always
-switched by VPP DUT twice per service chain.
-
-Note that reported VPP DUT performance results are specific to the SUTs
-tested. SUTs with other processor than the ones used in FD.io lab are
-likely to yield different results. Similarly to NIC-to-NIC switching
-topology, here one can also expect the forwarding performance to be
-proportional to processor core frequency for the same processor
-architecture, assuming processor is the only limiting factor. However
-due to much higher dependency on intensive memory operations in
-Container service chained topologies and sensitivity to Linux scheduler
-settings and behaviour, this estimation may not always yield good enough
-accuracy.
-
-Performance Tests Coverage
---------------------------
-
-Performance tests measure following metrics for tested VPP DUT
-topologies and configurations:
-
-- Packet Throughput: measured in accordance with :rfc:`2544`, using
- FD.io CSIT Multiple Loss Ratio search (MLRsearch), an optimized binary
- search algorithm, producing throughput at different Packet Loss Ratio
- (PLR) values:
-
- - Non Drop Rate (NDR): packet throughput at PLR=0%.
- - Partial Drop Rate (PDR): packet throughput at PLR=0.5%.
-
-- One-Way Packet Latency: measured at different offered packet loads:
-
- - 90% of discovered PDR throughput.
- - 50% of discovered PDR throughput.
- - 10% of discovered PDR throughput.
- - Minimal offered load.
-
-- Maximum Receive Rate (MRR): measure packet forwarding rate under the
- maximum load offered by traffic generator over a set trial duration,
- regardless of packet loss. Maximum load for specified Ethernet frame
- size is set to the bi-directional link rate, unless there is a known
- limitation preventing Traffic Generator from achieving the line rate.
-
-.. todo::
-
- - Connections per second (CPS): TODO
-
-|csit-release| includes following VPP data plane functionality
-performance tested across a range of NIC drivers and NIC models:
-
-+-----------------------+----------------------------------------------+
-| Functionality | Description |
-+=======================+==============================================+
-| ACL | L2 Bridge-Domain switching and |
-| | IPv4and IPv6 routing with iACL and oACL IP |
-| | address, MAC address and L4 port security. |
-+-----------------------+----------------------------------------------+
-| ADL | IPv4 and IPv6 routing with ADL address |
-| | security. |
-+-----------------------+----------------------------------------------+
-| GENEVE | GENEVE tunnels for IPv4 routing. |
-+-----------------------+----------------------------------------------+
-| IPv4 | IPv4 routing. |
-+-----------------------+----------------------------------------------+
-| IPv6 | IPv6 routing. |
-+-----------------------+----------------------------------------------+
-| IPv4 Scale | IPv4 routing with 20k, 200k and 2M FIB |
-| | entries. |
-+-----------------------+----------------------------------------------+
-| IPv6 Scale | IPv6 routing with 20k, 200k and 2M FIB |
-| | entries. |
-+-----------------------+----------------------------------------------+
-| IPSecAsyncHW | IPSec encryption with AES-GCM, CBC-SHA-256 |
-| | ciphers in async mode, in combination with |
-| | IPv4 routing. Intel QAT HW acceleration. |
-+-----------------------+----------------------------------------------+
-| IPSecHW | IPSec encryption with AES-GCM, CBC-SHA-256 |
-| | ciphers, in combination with IPv4 routing. |
-| | Intel QAT HW acceleration. |
-+-----------------------+----------------------------------------------+
-| IPSec+LISP | IPSec encryption with CBC-SHA1 ciphers, in |
-| | combination with LISP-GPE overlay tunneling |
-| | for IPv4-over-IPv4. |
-+-----------------------+----------------------------------------------+
-| IPSecSW | IPSec encryption with AES-GCM, CBC-SHA-256 |
-| | ciphers, in combination with IPv4 routing. |
-+-----------------------+----------------------------------------------+
-| KVM VMs vhost-user | Virtual topologies with service |
-| | chains of 1 VM using vhost-user |
-| | interfaces, with different VPP forwarding |
-| | modes incl. L2XC, L2BD, VXLAN with L2BD, |
-| | IPv4 routing. |
-+-----------------------+----------------------------------------------+
-| L2BD | L2 Bridge-Domain switching of untagged |
-| | Ethernet frames with MAC learning; disabled |
-| | MAC learning i.e. static MAC tests to be |
-| | added. |
-+-----------------------+----------------------------------------------+
-| L2BD Scale | L2 Bridge-Domain switching of untagged |
-| | Ethernet frames with MAC learning; disabled |
-| | MAC learning i.e. static MAC tests to be |
-| | added with 20k, 200k and 2M FIB entries. |
-+-----------------------+----------------------------------------------+
-| L2XC | L2 Cross-Connect switching of untagged, |
-| | dot1q, dot1ad VLAN tagged Ethernet frames. |
-+-----------------------+----------------------------------------------+
-| LISP | LISP overlay tunneling for IPv4-over-IPv4, |
-| | IPv6-over-IPv4, IPv6-over-IPv6, |
-| | IPv4-over-IPv6 in IPv4 and IPv6 routing |
-| | modes. |
-+-----------------------+----------------------------------------------+
-| LXC/DRC Containers | Container VPP memif virtual interface tests |
-| Memif | with different VPP forwarding modes incl. |
-| | L2XC, L2BD. |
-+-----------------------+----------------------------------------------+
-| NAT44 | (Source) Network Address Translation |
-| | deterministic mode and endpoint-dependent |
-| | mode tests with varying number of users and |
-| | ports per user for IPv4. |
-+-----------------------+----------------------------------------------+
-| QoS Policer | Ingress packet rate measuring, marking and |
-| | limiting (IPv4). |
-+-----------------------+----------------------------------------------+
-| SRv6 Routing | Segment Routing IPv6 tests. |
-+-----------------------+----------------------------------------------+
-| VPP TCP/IP stack | Tests of VPP TCP/IP stack used with VPP |
-| | built-in HTTP server. |
-+-----------------------+----------------------------------------------+
-| VTS | Virtual Topology System use case tests |
-| | combining VXLAN overlay tunneling with L2BD, |
-| | ACL and KVM VM vhost-user features. |
-+-----------------------+----------------------------------------------+
-| VXLAN | VXLAN overlay tunnelling integration with |
-| | L2XC and L2BD. |
-+-----------------------+----------------------------------------------+
-
-Execution of performance tests takes time, especially the throughput
-tests. Due to limited HW testbed resources available within FD.io labs
-hosted by :abbr:`LF (Linux Foundation)`, the number of tests for some
-NIC models has been limited to few baseline tests.
-
-Performance Tests Naming
-------------------------
-
-FD.io |csit-release| follows a common structured naming convention for
-all performance and system functional tests, introduced in CSIT-17.01.
-
-The naming should be intuitive for majority of the tests. Complete
-description of FD.io CSIT test naming convention is provided on
-:ref:`csit_test_naming`.