aboutsummaryrefslogtreecommitdiffstats
path: root/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot
diff options
context:
space:
mode:
Diffstat (limited to 'tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot')
-rw-r--r--tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot447
1 files changed, 211 insertions, 236 deletions
diff --git a/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot b/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot
index 58963a59d9..3bfcf9044f 100644
--- a/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot
+++ b/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot
@@ -24,7 +24,7 @@
| ...
| Test Setup | Performance test setup
| Test Teardown | Performance test with vhost and VM with dpdk-testpmd teardown
-| ... | ${min_rate}pps | ${framesize} | 3-node-IPv4
+| ... | ${min_rate}pps | ${framesize} | ${traffic_profile}
| ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs}
| ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs}
| ...
@@ -56,12 +56,14 @@
| ... | *[Ref] Applicable standard specifications:* RFC2544.
*** Variables ***
-#X520-DA2 bandwidth limit
+# X520-DA2 bandwidth limit
| ${s_limit} | ${10000000000}
| ${sock1}= | /tmp/sock-1
| ${sock2}= | /tmp/sock-2
| ${fib_table_1}= | 100
| ${fib_table_2}= | 101
+# Traffic profile:
+| ${traffic_profile} | trex-sl-3n-ethip4-ip4src253
*** Test Cases ***
| tc01-64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
@@ -79,23 +81,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc02-64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -112,25 +113,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc03-1518B-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -147,23 +146,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc04-1518B-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -180,25 +178,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc05-IMIX-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -216,23 +212,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc06-IMIX-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -250,25 +245,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc07-64B-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -285,23 +278,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc08-64B-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -318,25 +310,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc09-1518B-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -353,23 +343,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc10-1518B-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -386,25 +375,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc11-IMIX-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -422,23 +409,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc12-IMIX-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -456,25 +442,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc13-64B-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -491,23 +475,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc14-64B-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -524,25 +507,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc15-1518B-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -559,23 +540,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc16-1518B-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -592,25 +572,23 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
| tc17-IMIX-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc
| | [Documentation]
@@ -628,23 +606,22 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
| tc18-IMIX-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc
| | [Documentation]
@@ -662,22 +639,20 @@
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And Add PCI devices to DUTs from 3-node single link topology
-| | And Add No Multi Seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
-| | ... | ${sock1} | ${sock2}
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology
+| | ... | ${sock1} | ${sock2}
| | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
-| | ... | ${dut1_vif2_mac}
+| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac}
+| | ... | ${dut1_vif2_mac}
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
-| | ... | ${dut2_vif2_mac}
+| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac}
+| | ... | ${dut2_vif2_mac}
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | 3-node-IPv4
-| | ... | ${min_rate} | ${max_rate}
-| | ... | ${threshold}
-| | ... | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
+| | ... | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}