From ddbfd9e68e81e77bd253c8b6cd81839ec3bd2715 Mon Sep 17 00:00:00 2001 From: Maciek Konstantynowicz Date: Wed, 27 Feb 2019 21:27:04 +0000 Subject: docs/lab: merged testbed specifications, separated out detailed HW and BIOS configs. Change-Id: I5945723676361fdbe180a3bd5a6a366102ee6c67 Signed-off-by: Maciek Konstantynowicz --- docs/lab/testbed_specifications.md | 1469 ++++++++++++++++++++++++++++++++++++ 1 file changed, 1469 insertions(+) create mode 100644 docs/lab/testbed_specifications.md (limited to 'docs/lab/testbed_specifications.md') diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md new file mode 100644 index 0000000000..b12d42d22f --- /dev/null +++ b/docs/lab/testbed_specifications.md @@ -0,0 +1,1469 @@ + + + - [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications) + - [Testbeds Overview](#testbeds-overview) + - [Summary List](#summary-list) + - [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) + - [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) + - [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) + - [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) + - [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) + - [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) + - [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) + - [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) + - [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell) + - [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) + - [Server Management](#server-management) + - [Requirements](#requirements) + - [Addressing](#addressing) + - [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) + - [Management VLAN IP Addresses](#management-vlan-ip-addresses) + - [Server Type Specification](#server-type-specification) + - [Server and Port Naming](#server-and-port-naming) + - [Testbeds Configuration](#testbeds-configuration) + - [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) + - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) + - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) + - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) + - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) + - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) + - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) + - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) + - [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify) + - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) + - [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo) + - [Per Testbed Wiring](#per-testbed-wiring) + - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) + - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) + - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) + - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) + - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) + - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) + - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) + - [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo) + - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) + - [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip) + - [Inventory](#inventory) + - [Appliances](#appliances) + - [Arm Servers](#arm-servers) + - [Xeon and Atom Servers](#xeon-and-atom-servers) + - [Network Interface Cards](#network-interface-cards) + - [Pluggables and Cables](#pluggables-and-cables) + - [Other Parts](#other-parts) + + +## FD.io CSIT Testbed Specifications + +This note includes specification of the physical testbed infrastructure +hosted by LFN FD.io CSIT project. + +## Testbeds Overview + +### Summary List + +``` + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb + 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0 + 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0 + 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 + 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 + 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 + 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 + 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 + 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 + 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 +10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 +11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 + Totals: 17 26 14 12 19 1 2 1 1 2 2 +``` + +### 1-Node-Skylake Xeon Intel (1n-skx) + +Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC +ports connected back-to-back. +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-ThunderX2 Arm Marvell (1n-tx2) + +Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC +ports connected back-to-back. +Used for FD.io VPP_Device functional driver tests. + +### 2-Node-Skylake Xeon Intel (2n-skx) + +Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG +(Type-B2 server) connected back-to-back. +Used for FD.io performance tests. + +### 2-Node-Denverton Atom Intel (2n-dnv) + +Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG +(Type-B2 server) connected back-to-back. +Used for FD.io performance tests. + +### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) + +Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one +TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back. +Used for FD.io TCP/IP and HTTP performance tests. + +### 3-Node-Haswell Xeon Intel (3n-skx) + +### 3-Node-Skylake Xeon Intel (3n-skx) + +Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one +TG (Type-B2 server) connected in full-mesh triangle. +Used for FD.io performance tests. + +### 3-Node-TaiShan Arm Huawei (3n-tsh) + +Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG +(Type-B2 server) connected in full-mesh triangle. +Used for FD.io performance tests. + +### 3-Node-MACCHIATObin Arm Marvell + +Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and +one TG (Type-B2 server) connected in full-mesh triangle. +Used for FD.io performance tests. + +### 3-Node-Rangeley Atom Testbeds + +Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device) +and one TG (Type-2 server) connected in full-mesh triangle. +Used for FD.io performance tests. + +## Server Management + +### Requirements + +For management purposes, each server must have following two ports +connected to the management network: + +``` +- 1GE IPMI port + - IPMI - Intelligent Platform Management Interface. + - Required for access to embedded server management with WebUI, CLI, SNMPv3, + IPMIv2.0, for firmware (BIOS) and OS updates. +- 1GE/10GE/40GE management port + - hostOS management port for general system management. +``` + +### Addressing + +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management +port, which are connected to two different VLANs. + +``` +1. LOM (IPMI) VLAN: + - Subnet: 10.30.50.0/24 + - Gateway: 10.30.50.1 + - Broadcast: 10.30.50.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 +2. Management Vlan: + - Subnet: 10.30.51.0/24 + - Gateway: 10.30.51.1 + - Broadcast: 10.30.51.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 +``` + +To access these hosts, VPN connection is required. + +### LOM (IPMI) VLAN IP Addresses + +Name | Comment +------------ | ------- +10.30.50.0 | network +10.30.51.1 | Router +10.30.50.2 | LF Reserved +10.30.50.3 | LF Reserved +10.30.50.4 | LF Reserved +10.30.50.5 | LF Reserved +10.30.50.6 | LF Reserved +10.30.50.7 | LF Reserved +10.30.50.8 | LF Reserved +10.30.50.9 | LF Reserved +10.30.50.10 | LF Reserved +10.30.50.11 | LF Reserved +10.30.50.12 | LF Reserved +10.30.50.13 | LF Reserved +10.30.50.14 | LF Reserved +10.30.50.15 | LF Reserved +10.30.50.16 | t1-tg1 +10.30.50.17 | t1-sut1 +10.30.50.18 | t1-sut2 +10.30.50.20 | t2-tg1 +10.30.50.21 | t2-sut1 +10.30.50.22 | t2-sut2 +10.30.50.24 | t3-tg1 +10.30.50.25 | t3-sut1 +10.30.50.26 | t3-sut-2 +10.30.50.28 | t4-sut1 +10.30.50.29 | t4-sut2 +10.30.50.30 | t4-sut3 +10.30.50.36 | s17-t33-sut1 +10.30.50.37 | s18-t33-sut2 +10.30.50.41 | s3-t21-sut1 +10.30.50.42 | s4-t21-tg1 +10.30.50.43 | s11-t31-sut1 +10.30.50.44 | s12-t31-sut2 +10.30.50.45 | s13-t31-tg1 +10.30.50.46 | s19-t33t34-tg1 +10.30.50.47 | s1-t11-sut1 +10.30.50.48 | s2-t12-sut1 +10.30.50.49 | s5-t22-sut1 +10.30.50.50 | s6-t22-tg1 +10.30.50.51 | s7-t23-sut1 +10.30.50.52 | s8-t23-tg1 +10.30.50.53 | s9-t24-sut1 +10.30.50.54 | s10-t24-tg1 +10.30.50.55 | s14-t32-sut1 +10.30.50.56 | s15-t32-sut2 +10.30.50.57 | s16-t32-tg1 +10.30.50.58 | s25-t25-sut1 +10.30.50.59 | s26-t25-tg1 +10.30.50.69 | s27-t13-sut +10.30.50.255 | Broadcast + +### Management VLAN IP Addresses + +Name | Comment +------------------------- | ------- +10.30.51.0 | network +10.30.51.1 | Router +10.30.51.2 | LF Reserved +10.30.51.3 | LF Reserved +10.30.51.4 | LF Reserved +10.30.51.5 | LF Reserved +10.30.51.6 | LF Reserved +10.30.51.7 | LF Reserved +10.30.51.8 | LF Reserved +10.30.51.9 | s22-t35-sut1 (netgate-1) +10.30.51.10 | s23-t35-sut2 (netgate-2) +10.30.51.11 | s24-t35-sut3 (netgate-3) +10.30.51.12 | softiron-1 +10.30.51.13 | softiron-2 +10.30.51.14 | softiron-3 +10.30.51.15 | LF Reserved +10.30.51.16 | t1-tg1 +10.30.51.17 | t1-sut1 +10.30.51.18 | t1-sut2 +10.30.51.20 | t2-tg1 +10.30.51.21 | t2-sut1 +10.30.51.22 | t2-sut2 +10.30.51.24 | t3-tg1 +10.30.51.25 | t3-sut1 +10.30.51.26 | t3-sut-2 +10.30.51.28 | t4-sut1 +10.30.51.29 | t4-sut2 +10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED +10.30.51.30 | t4-sut3 +10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED +10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED +10.30.51.36 | s17-t33-sut1 +10.30.51.37 | s18-t33-sut2 +10.30.51.41 | s20-t34-sut1 +10.30.51.42 | s21-t34-sut2 +10.30.51.44 | s3-t21-sut1 +10.30.51.45 | s4-t21-tg1 +10.30.51.46 | s11-t31-sut1 +10.30.51.47 | s12-t31-sut2 +10.30.51.48 | s13-t31-tg1 +10.30.51.49 | s19-t33t34-tg1 +10.30.51.50 | s1-t11-sut1 +10.30.51.51 | s2-t12-sut1 +10.30.51.52 | s5-t22-sut1 +10.30.51.53 | s6-t22-tg1 +10.30.51.54 | s7-t23-sut1 +10.30.51.55 | s8-t23-tg1 +10.30.51.56 | s9-t24-sut1 +10.30.51.57 | s10-t24-tg1 +10.30.51.58 | s14-t32-sut1 +10.30.51.59 | s15-t32-sut2 +10.30.51.60 | s16-t32-tg1 +10.30.51.61 | s25-t25-sut1 +10.30.51.62 | s26-t25-tg1 +10.30.51.69 | s27-t13-sut1 +10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED +10.30.51.106-10.30.51.180 | VIRL2 +10.30.51.181-10.30.51.254 | VIRL3 +10.30.51.255 | Broadcast + +## Server Type Specification + +FD.io CSIT lab contains following server types: +``` +1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. + - Quantity: 6 servers. + - Physical connectivity: + - CIMC and host management ports. + - NIC ports connected in 3-node topologies. + - Main HW configuration: + - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. + - Processors: 2* E5-2699v3 2.3 GHz. + - RAM Memory: 16* 32GB DDR4-2133MHz. + - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. + - NICs configuration: + - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) + - PCIe Slot1: Cisco VIC 1385 2p40GE. + - PCIe Slot2: Intel NIC x520 2p10GE. + - PCIe Slot3: empty. + - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) + - PCIe Slot4: Intel NIC xl710 2p40GE. + - PCIe Slot5: Intel NIC x710 2p10GE. + - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) + - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). +2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. + - Quantity: 3 servers. + - Physical connectivity: + - CIMC and host management ports. + - NIC ports connected in 3-node topologies. + - Main HW configuration: + - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. + - Processors: 2* E5-2699v3 2.3 GHz. + - RAM Memory: 16* 32GB DDR4-2133MHz. + - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. + - NICs configuration: + - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) + - PCIe Slot1: Intel NIC xl710 2p40GE. + - PCIe Slot2: Intel NIC x710 2p10GE. + - PCIe Slot3: Intel NIC x710 2p10GE. + - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) + - PCIe Slot4: Intel NIC xl710 2p40GE. + - PCIe Slot5: Intel NIC x710 2p10GE. + - PCIe Slot6: Intel NIC x710 2p10GE. + - MLOM slot: empty. +3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. + - Quantity: 3 servers. + - Physical connectivity: + - CIMC and host management ports. + - no NIC ports, standalone setup. + - Main HW configuration: + - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. + - Processors: 2* E5-2699v3 2.3 GHz. + - RAM Memory: 16* 32GB DDR4-2133MHz. + - Disks: 2* 480 GB 2.5inch 6G SATA SSD. + - NICs configuration: + - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) + - no cards. + - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) + - no cards. + - MLOM slot: empty. +4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. + - Quantity: --- + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: --- + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. +3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slot6 11:00.xx: 82599-2p10GE Intel. +4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. + - Quantity: 3 + - Physical connectivity: + - Host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: MACCHIATObin. + - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72 + - RAM Memory: 1* 16GB DDR4 + - Disks: 1* 128GB(?) SATA SDD + - NICs configuration: + - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) +5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. + - Quantity: TBD based on testbed allocation. + - Physical connectivity: + - Management: serial Port (usb) for console + - NIC ports connected into 2-node. + - Main HW configuration: + - Chassis: Netgate XG-2758-1u + - Processors: 1* Rangeley (Atom) C2758 2.4 GHz + - RAM Memory: 16GB ECC + - Disks: 150 GB + - NICs configuration: + - 2x 10Gb Intel 82599ES + - 4x 1GB Intel I354 +6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. + - Quantity: 1. + - Physical connectivity: + - Host management interface: 10/100/1000-BaseT. + - 8-port 10GE SFP+ integrated NIC. + - Main HW configuration: + - Chassis: PS10GE4NG. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: Quad-Core, Intel Processor. + - HW accelerators: FPGA offload. + - RAM Memory: 64GB. + - Disks: 1 * 1 TB, Enterprise Class, High MTBF. + - Physical Interfaces: 4 * 10GE SFP+. + - Operating System: Native IxOS. + - Interface configuration: + - Port-1: 10GE SFP+. + - Port-2: 10GE SFP+. + - Port-3: 10GE SFP+. + - Port-4: 10GE SFP+. +8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: Gigabyte R181-T90 1U + - Motheboard: MT91-FS1 + - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - NICs configuration: + - Numa0: + - PCIe Slot1 05:00.xx: XL710-QDA2. + - PCIe Slot3 08:00.xx: XL710-QDA2. + - Numa1: + - PCIe Slot6 85:00.xx: XL710-QDA2. +10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. + - Quantity: 4 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-E300-9A + - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz + - RAM Memory: 32GB ECC + - Disks: 480 GB + - NICs configuration: + - 2x 10Gb Intel x553 fiber ports + - 2x 10Gb Intel x553 copper ports + - 4x 1GB Intel I350 ports +``` + +### Server and Port Naming + +Following naming convention is used within this page to specify physical +connectivity and wiring across defined CSIT testbeds: + +``` +- testbedname: testbedN. +- hostname: + - traffic-generator: tN-tgW. + - system-under-testX: tN-sutX. +- portnames: + - tN-tgW-cY/pZ. + - tN-sutX-cY/pZ. +- where: + - N - testbed number. + - tgW - server acts as traffic-generator with W index. + - sutX - server acts as system-under-test with X index. + - Y - PCIe slot number denoting a NIC card number within the host. + - Z - port number on the NIC card. +``` + +## Testbeds Configuration + +### Per Testbed Server Allocation and Naming + +#### 1-Node-Skylake (1n-skx) PROD + +``` +- ServerB1 [Type-B6]: + - testbedname: testbed11. + - hostname: s1-t11-sut1. + - IPMI IP: 10.30.50.47 + - Host IP: 10.30.51.50 + - portnames: + - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +- ServerB2 [Type-B6]: + - testbedname: testbed12. + - hostname: s2-t12-sut1. + - IPMI IP: 10.30.50.48 + - Host IP: 10.30.51.51 + - portnames: + - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 1-Node-Thunderx2 (1n-tx2) WIP + +``` +- ServerB17 [Type-B9]: + - testbedname: testbed13. + - hostname: s27-t13-sut1. + - IPMI IP: 10.30.50.69 + - Host IP: 10.30.51.69 + - portnames: + - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. +``` + +#### 2-Node-Skylake (2n-skx) PROD + +``` +- ServerB3 [Type-B1]: + - testbedname: testbed21. + - hostname: s3-t21-sut1. + - IPMI IP: 10.30.50.41 + - Host IP: 10.30.51.44 + - portnames: + - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB4 [Type-B2]: + - testbedname: testbed21. + - hostname: s4-t21-tg1. + - IPMI IP: 10.30.50.42 + - Host IP: 10.30.51.45 + - portnames: + - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB5 [Type-B1]: + - testbedname: testbed22. + - hostname: s5-t22-sut1. + - IPMI IP: 10.30.50.49 + - Host IP: 10.30.51.52 + - portnames: + - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB6 [Type-B2]: + - testbedname: testbed22. + - hostname: s6-t22-tg1. + - IPMI IP: 10.30.50.50 + - Host IP: 10.30.51.53 + - portnames: + - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB7 [Type-B1]: + - testbedname: testbed23. + - hostname: s7-t23-sut1. + - IPMI IP: 10.30.50.51 + - Host IP: 10.30.51.54 + - portnames: + - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB8 [Type-B2]: + - testbedname: testbed23. + - hostname: s8-t23-tg1. + - IPMI IP: 10.30.50.52 + - Host IP: 10.30.51.55 + - portnames: + - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB9 [Type-B1]: + - testbedname: testbed24. + - hostname: s9-t24-sut1. + - IPMI IP: 10.30.50.53 + - Host IP: 10.30.51.56 + - portnames: + - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB10 [Type-B2]: + - testbedname: testbed24. + - hostname: s10-t24-tg1. + - IPMI IP: 10.30.50.54 + - Host IP: 10.30.51.57 + - portnames: + - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +``` + +#### 2-Node-Denverton (2n-dnv) TODO + +``` +To be completed. +``` + +#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY + +``` +- ServerB25 [Type-B8]: + - testbedname: testbed25. + - hostname: s25-t25-sut1. + - IPMI IP: 10.30.50.58 + - Host IP: 10.30.51.61 + - portnames: + - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. +- ServerB26 [Type-B7]: + - testbedname: testbed25. + - hostname: s26-t25-tg1. + - IPMI IP: 10.30.50.59 + - Host IP: 10.30.51.62 + - portnames: + - s26-t25-tg1-p1 - 10GE-port1. + - s26-t25-tg1-p2 - 10GE-port2. + - s26-t25-tg1-p3 - 10GE-port3. + - s26-t25-tg1-p4 - 10GE-port4. +``` + +#### 3-Node-Haswell (3n-hsw) PROD + +``` + 1. Server1 of Type-1: + - testbedname: testbed1. + - hostname: t1-sut1. + - CIMC IP: 10.30.50.17 + - Host IP: 10.30.51.17 + - portnames: + - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 2. Server2 of Type-1: + - testbedname: testbed1. + - hostname: t1-sut2. + - CIMC IP: 10.30.50.18 + - Host IP: 10.30.51.18 + - portnames: + - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 3. Server3 of Type-2: + - testbedname: testbed1. + - hostname: t1-tg1. + - CIMC IP: 10.30.50.16 + - Host IP: 10.30.51.16 + - portnames: + - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. + 4. Server4 of Type-1: + - testbedname: testbed2. + - hostname: t2-sut1. + - CIMC IP: 10.30.50.21 + - Host IP: 10.30.51.21 + - portnames: + - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 5. Server5 of Type-1: + - testbedname: testbed2. + - hostname: t2-sut2. + - CIMC IP: 10.30.50.22 + - Host IP: 10.30.51.22 + - portnames: + - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 6. Server6 of Type-2: + - testbedname: testbed2. + - hostname: t2-tg1. + - CIMC IP: 10.30.50.20 + - Host IP: 10.30.51.20 + - portnames: + - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. + 7. Server7 of Type-1: + - testbedname: testbed3. + - hostname: t3-sut1. + - CIMC IP: 10.30.50.25 + - Host IP: 10.30.51.25 + - portnames: + - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 8. Server8 of Type-1: + - testbedname: testbed3. + - hostname: t3-sut2. + - CIMC IP: 10.30.50.26 + - Host IP: 10.30.51.26 + - portnames: + - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. + - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. + - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. + - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. + - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. + - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. + 9. Server9 of Type-2: + - testbedname: testbed3. + - hostname: t3-tg1. + - CIMC IP: 10.30.50.24 + - Host IP: 10.30.51.24 + - portnames: + - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. + - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. + - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. + - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. +``` + +#### 3-Node-Skylake (3n-skx) PROD + +``` +- ServerB11 [Type-B1]: + - testbedname: testbed31. + - hostname: s11-t31-sut1. + - IPMI IP: 10.30.50.43 + - Host IP: 10.30.51.46 + - portnames: + - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB12 [Type-B1]: + - testbedname: testbed31. + - hostname: s12-t31-sut2. + - IPMI IP: 10.30.50.44 + - Host IP: 10.30.51.47 + - portnames: + - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE. + - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE. + - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE. + - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. + - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB13 [Type-B2]: + - testbedname: testbed31. + - hostname: s13-t31-tg1. + - IPMI IP: 10.30.50.45 + - Host IP: 10.30.51.48 + - portnames: + - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB14 [Type-B1]: + - testbedname: testbed32. + - hostname: s14-t32-sut1. + - IPMI IP: 10.30.50.55 + - Host IP: 10.30.51.58 + - portnames: + - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB15 [Type-B1]: + - testbedname: testbed32. + - hostname: s15-t32-sut2. + - IPMI IP: 10.30.50.56 + - Host IP: 10.30.51.59 + - portnames: + - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE. + - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE. + - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE. + - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. + - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- ServerB16 [Type-B2]: + - testbedname: testbed32. + - hostname: s16-t32-tg1. + - IPMI IP: 10.30.50.57 + - Host IP: 10.30.51.60 + - portnames: + - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +``` + +Note: ServerB19 (TG) is shared between testbed33 & testbed34 + +#### 3-Node-Rangeley (3n-rng) VERIFY + +Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. + +``` +- ServerB22 [Type-B5]: + - testbedname: testbed35. + - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). + - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 + - Host IP: 10.30.51.9 + - portnames: + - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- ServerB23 [Type-B5]: + - testbedname: testbed35. + - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 + - Host IP: 10.30.51.10 + - portnames: + - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- ServerB24 [Type-B5]: + - testbedname: testbed35. + - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 + - Host IP: 10.30.51.11 + - portnames: + - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +``` + +#### 3-Node-Taishan (3n-tsh) WIP + +``` +- ServerB17 [Type-B3]: + - testbedname: testbed33. + - hostname: s17-t33-sut1. + - IPMI IP: 10.30.50.36 + - Host IP: 10.30.51.36 + - portnames: + - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE. + - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE. + - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. + - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. +- ServerB18 [Type-B3]: + - testbedname: testbed33. + - hostname: s18-t33-sut2. + - IPMI IP: 10.30.50.37 + - Host IP: 10.30.51.37 + - portnames: + - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE. + - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE. + - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. + - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. +- ServerB19 [Type-B2]: + - testbednames: testbed33 and testbed34. + - hostname: s19-t33t34-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 + - portnames: + - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +- ServerB20 [Type-B4]: + - testbedname: testbed34. + - hostname: s20-t34-sut1. + - IPMI IP: N/A + - Host IP: 10.30.51.41 + - portnames: + - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. + - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. +- ServerB21 [Type-B4]: + - testbedname: testbed34. + - hostname: s21-t34-sut2. + - IPMI IP: N/A + - Host IP: 10.30.51.42 + - portnames: + - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell. + - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. +``` + +#### 3-Node-Mcbin (3n-mcb) TODO + +``` +To be completed. +``` + +### Per Testbed Wiring + +#### 1-Node-Skylake (1n-skx) PROD + +``` +- testbed11: + - ring1 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. +- testbed12: + - ring1 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. +``` + +#### 1-Node-Thunderx2 (1n-tx2) WIP + +``` +- testbed13: + - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1. + - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1. + - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. +``` + +#### 2-Node-Skylake (2n-skx) PROD + +``` +- testbed21: + - ring1 10GE-ports x710-4p10GE on SUT: + - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1. + - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3. + - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. + - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. + - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. + - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. +- testbed22: + - ring1 10GE-ports x710-4p10GE on SUT: + - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. + - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3. + - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. + - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. + - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. + - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. +- testbed23: + - ring1 10GE-ports x710-4p10GE on SUT: + - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. + - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3. + - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. + - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. + - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. + - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. +- testbed24: + - ring1 10GE-ports x710-4p10GE on SUT: + - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. + - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3. + - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. + - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. + - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. + - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. +``` + +#### 2-Node-Denverton (2n-dnv) TODO + +``` +To be completed. +``` + +#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY + +``` +- testbed25: + - link1 10GE-port x710-4p10GE on SUT: + - t25-tg1-p1 to t25-sut1-c2/p1. + - link2 10GE-port x710-4p10GE on SUT: + - t25-tg1-p2 to t25-sut1-c2/p2. + - link3 10GE-port x710-4p10GE on SUT: + - t25-tg1-p3 to t25-sut1-c2/p3. + - link4 10GE-port x710-4p10GE on SUT: + - t25-tg1-p4 to t25-sut1-c2/p4. +``` + +#### 3-Node-Haswell (3n-hsw) PROD + +``` + 1. testbed1: + - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs + - t1-tg1-c1/p1 to t1-sut1-c1/p2. + - t1-sut1-c1/p1 to t1-sut2-c1/p2. + - t1-sut2-c1/p1 to t1-tg1-c1/p2. + - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs + - t1-tg1-c2/p1 to t1-sut1-c2/p2. + - t1-sut1-c2/p1 to t1-sut2-c2/p2. + - t1-sut2-c2/p1 to t1-tg1-c2/p2. + - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs + - t1-tg1-c4/p1 to t1-sut1-c4/p2. + - t1-sut1-c4/p1 to t1-sut2-c4/p2. + - t1-sut2-c4/p1 to t1-tg1-c4/p2. + - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs + - t1-tg1-c5/p1 to t1-sut1-c5/p2. + - t1-sut1-c5/p1 to t1-sut2-c5/p2. + - t1-sut2-c5/p1 to t1-tg1-c5/p2. + - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs + - t1-tg1-c2/p1 to t1-sut1-cm/p2. + - t1-sut1-cm/p1 to t1-sut2-cm/p2. + - t1-sut2-cm/p1 to t1-tg1-c2/p2. + - TG loopback ports Intel NIC x710 2p10GE + - t1-tg1-c6/p1 to t1-tg1-c6/p2. + + 2. testbed2: + - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs + - t2-tg1-c1/p1 to t2-sut1-c1/p2. + - t2-sut1-c1/p1 to t2-sut2-c1/p2. + - t2-sut2-c1/p1 to t2-tg1-c1/p2. + - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs + - t2-tg1-c2/p1 to t2-sut1-c2/p2. + - t2-sut1-c2/p1 to t2-sut2-c2/p2. + - t2-sut2-c2/p1 to t2-tg1-c2/p2. + - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs + - t2-tg1-c4/p1 to t2-sut1-c4/p2. + - t2-sut1-c4/p1 to t2-sut2-c4/p2. + - t2-sut2-c4/p1 to t2-tg1-c4/p2. + - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs + - t2-tg1-c5/p1 to t2-sut1-c5/p2. + - t2-sut1-c5/p1 to t2-sut2-c5/p2. + - t2-sut2-c5/p1 to t2-tg1-c5/p2. + - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs + - t2-tg1-c2/p1 to t2-sut1-cm/p2. + - t2-sut1-cm/p1 to t2-sut2-cm/p2. + - t2-sut2-cm/p1 to t2-tg1-c2/p2. + - TG loopback ports Intel NIC x710 2p10GE + - t2-tg1-c6/p1 to t2-tg1-c6/p2. + + 3. testbed3: + - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs + - t3-tg1-c1/p1 to t3-sut1-c1/p2. + - t3-sut1-c1/p1 to t3-sut2-c1/p2. + - t3-sut2-c1/p1 to t3-tg1-c1/p2. + - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs + - t3-tg1-c2/p1 to t3-sut1-c2/p2. + - t3-sut1-c2/p1 to t3-sut2-c2/p2. + - t3-sut2-c2/p1 to t3-tg1-c2/p2. + - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs + - t3-tg1-c4/p1 to t3-sut1-c4/p2. + - t3-sut1-c4/p1 to t3-sut2-c4/p2. + - t3-sut2-c4/p1 to t3-tg1-c4/p2. + - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs + - t3-tg1-c5/p1 to t3-sut1-c5/p2. + - t3-sut1-c5/p1 to t3-sut2-c5/p2. + - t3-sut2-c5/p1 to t3-tg1-c5/p2. + - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs + - t3-tg1-c2/p1 to t3-sut1-cm/p2. + - t3-sut1-cm/p1 to t3-sut2-cm/p2. + - t3-sut2-cm/p1 to t3-tg1-c2/p2. + - TG loopback ports Intel NIC x710 2p10GE + - t3-tg1-c6/p1 to t3-tg1-c6/p2. +``` + +#### 3-Node-Skylake (3n-skx) PROD + +``` +- testbed31: + - ring1 10GE-ports x710-4p10GE on SUTs: + - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1. + - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2. + - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3. + - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4. + - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1. + - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2. + - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1. + - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2. + - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2. + - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4. +- testbed32: + - ring1 10GE-ports x710-4p10GE on SUTs: + - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1. + - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2. + - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3. + - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4. + - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1. + - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2. + - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1. + - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2. + - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2. + - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. +``` + +#### 3-Node-Rangeley (3n-rng) TODO + +``` +To be completed. +``` + +#### 3-Node-Taishan (3n-tsh) WIP + +``` +- testbed33: + - ring1 10GE-ports 82599-2p10GE on SUTs: + - t33t34-tg1-c2/p2 - t33-sut1-c6/p2. + - t33-sut1-c6/p1 - t33-sut2-c6/p2. + - t33-sut2-c6/p1 - t33t34-tg1-c2/p1. + - ring2 25GE-ports cx4-2p25GE on SUTs: + - t33t34-tg1-c4/p2 - t33-sut1-c4/p2. + - t33-sut1-c4/p1 - t33-sut2-c4/p2. + - t33-sut2-c4/p1 - t33t34-tg1-c4/p1. +``` + +#### 3-Node-Mcbin (3n-mcb) WIP + +``` +- testbed34: + - ring1 10GE-ports Marvell on SUTs: + - t33t34-tg1-c2/p3 - t34-sut1-ca/p1. + - t34-sut1-ca/p2 - t34-sut2-ca/p1. + - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. +``` + +## Inventory + +### Appliances + +``` +1. Ixia PerfectStorm One Appliance + - 1 * PS10GE4NG + - Chassis: PS10GE4NG. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: Quad-Core, Intel Processor. + - HW accelerators: FPGA offload. + - RAM Memory: 64GB. + - Disks: 1 * 1 TB, Enterprise Class, High MTBF. + - Physical Interfaces: 4 * 10GE SFP+. + - Operating System: Native IxOS. +``` + +### Arm Servers + +``` +1. Arm Cortex A-72 servers + - 1 * ThunderX2 + - Chassis: Marvell ThunderX2 + - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2. + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - 2 * Huawei TaiShan 2280. + - Chassis: Huawei TaiShan 2280. + - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. + - RAM Memory: 8* 16GB DDR4-2400MT/s. + - Disks: 1* 4TB SATA HDD. + - 3 * MACCHIATObin + - Chassis: MACCHIATObin. + - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72. + - RAM Memory: 1* 16GB DDR4. + - Disks: 1* 128GB(?) SATA SDD. +``` + +### Xeon and Atom Servers + +``` +1. Intel Xeon servers: + - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. +2. Intel Atom servers with Rangely processors. + - 3 * Netgate XG-2758-1u + - Chassis: Netgate XG-2758-1u + - Processors: 1* Rangely (Atom) C2758 2.4 GHz + - RAM Memory: 16GB ECC + - Disks: 150 GB +``` + +### Network Interface Cards + +``` +1. 10GE NICs + - 14 * Intel® Ethernet Converged Network Adapter X710-DA4 + - 6 * Intel® Ethernet Converged Network Adapter X710-DA2 + - 6 * Intel® Ethernet Converged Network Adapter X520-DA2 +2. 25GE NICs + - 12 * Intel® Ethernet Network Adapter XXV710-DA2 +3. 40GE NICs + - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2 +4. 100GE NICs + - 4 * mcx556a-edat NICs (not on site yet, in transit) +``` + +### Pluggables and Cables + +Pluggables: + +``` +1. 10GE SFP+ + - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics + - 80 * 10G SR optic (generic, "Intel" compatible branded) +2. 25GE SFP28 + - None +3. 40GE QSFP+ + - None +4. 100GE + - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit) +``` + +Standalone cables: + +``` +1. 10GE + - None +2. 25GE + - None +3. 40GE QSFP+ + - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable +4. 100GE + - None +``` + +### Other Parts + +None. -- cgit 1.2.3-korg