From b928e56347c682fdb9762ccbe2f368329d4037e4 Mon Sep 17 00:00:00 2001 From: pmikus Date: Thu, 9 Mar 2023 13:32:33 +0000 Subject: feat(docs): Hugo Signed-off-by: pmikus Change-Id: Id8b43ef1f31f39b19a0629c52581514fda278f3b --- docs/lab/fdio-dc-physical.md | 118 -- docs/lab/fdio-dc-physical.yaml | 462 -------- docs/lab/testbed_specifications.md | 1879 ------------------------------- docs/lab/testbeds_sm_clx_hw_bios_cfg.md | 1439 ----------------------- docs/lab/testbeds_sm_icx_hw_bios_cfg.md | 1132 ------------------- docs/lab/testbeds_sm_spr_hw_bios_cfg.md | 845 -------------- docs/lab/testbeds_sm_zn2_hw_bios_cfg.md | 634 ----------- 7 files changed, 6509 deletions(-) delete mode 100644 docs/lab/fdio-dc-physical.md delete mode 100644 docs/lab/fdio-dc-physical.yaml delete mode 100644 docs/lab/testbed_specifications.md delete mode 100644 docs/lab/testbeds_sm_clx_hw_bios_cfg.md delete mode 100644 docs/lab/testbeds_sm_icx_hw_bios_cfg.md delete mode 100644 docs/lab/testbeds_sm_spr_hw_bios_cfg.md delete mode 100644 docs/lab/testbeds_sm_zn2_hw_bios_cfg.md (limited to 'docs/lab') diff --git a/docs/lab/fdio-dc-physical.md b/docs/lab/fdio-dc-physical.md deleted file mode 100644 index 055a084336..0000000000 --- a/docs/lab/fdio-dc-physical.md +++ /dev/null @@ -1,118 +0,0 @@ - - -- [FD.io DC Vexxhost Inventory](#fdio-dc-vexxhost-inventory) - - [Missing Equipment Inventory](#missing-equipment-inventory) - - [YUL1 Inventory](#yul1-inventory) - - [Rack YUL1-8 (3016.8)](#rack-yul1-8-3016.8) - - [Rack YUL1-9 (3016.9)](#rack-yul1-9-3016.9) - - [Rack YUL1-10 (3016.10)](#rack-yul1-10-3016.10) - - [Rack YUL1-11 (3016.11)](#rack-yul1-11-3016.11) - - [Rack YUL1-12 (3016.12)](#rack-yul1-12-3016.12) - - - -## FD.io DC Vexxhost Inventory - -- for each DC location, per rack .csv table with server inventory -- captured inventory data: name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4 - - name: CSIT functional server name as tracked in [CSIT testbed specification](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md), followed by "/" and the actual configured hostname, unless it is the same as CSIT name. - - oper-status: operational status (up|down|ipmi). - - testbed-id: CSIT testbed identifier. - - role: 2n/3n-xxx performance testbed, nomad-client, nomad-server. - - role exceptions: decommission, repurpose, spare. - - model: server model. - - s/n: serial number. - - mgmt-ip4: current management IPv4 address on management VLAN. - - ipmi-ip4: current IPMI IPv4 address on LOM VLAN. - - rackid: new location rack id. - - rackunit: new location rack unit id. - -### Missing Equipment Inventory - -1. Ixia PerfectStorm One Appliance - - [Specification: Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n554) - - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017) - - [mgmt-ip4 10.30.51.62 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n374) - - [ipmi-ip4 10.30.50.59 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n281) - -### YUL1 Inventory - -#### Rack YUL1-8 (3016.8) -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -mtl1-8-lb4m,up,switch,uplink,?,?,?,?,3016.8,u47,?,? -s65-t37-sut1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50098,10.30.51.75,10.30.50.75,3016.8,u42-u45 -s66-t37-sut2,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK33P50247,10.30.51.76,10.30.50.76,3016.8,u38-u41 -s67-t37-tg1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50076,10.30.51.77,10.30.50.77,3016.8,u34-u37 -s71-t212-sut1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK25P50173,10.30.51.81,10.30.50.81,3016.8,u30-u33 -s72-t212-tg1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK33P50220,10.30.51.82,10.30.50.82,3016.8,u26-u29 -s83-t213-sut1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL07P50300,10.30.51.83,10.30.50.83,3016.8,u22-u25 -s84-t213-tg1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL03P50187,10.30.51.84,10.30.50.84,3016.8,u18-u21 -s85-t214-sut1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KK33P50219,10.30.51.85,10.30.50.85,3016.8,u14-u17 -s86-t214-tg1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KL07P50312,10.30.51.86,10.30.50.86,3016.8,u10-u13 -s87-t215-sut1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL03P50171,10.30.51.87,10.30.50.87,3016.8,u6-u9 -s88-t215-tg1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL07P50301,10.30.51.88,10.30.50.88,3016.8,u2-u5 - -#### Rack YUL1-9 (3016.9) -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -mtl1-5-lb4m,up,switch,uplink,?,?,?,?,3016.9,u47,?,? -s52-t21-sut1,up,t21,2n-spr,SYS-741GE-TNRT,C7490FL36A40118,10.30.51.52,10.30.50.52,3016.9,u42-u45 -s53-t21-tg1,up,t21,2n-spr,SYS-741GE-TNRT,???,10.30.51.53,10.30.50.53,3016.9,u38-u41 -s54-t22-sut1,up,t22,2n-spr,SYS-741GE-TNRT,???,10.30.51.54,10.30.50.54,3016.9,u34-u37 -s55-t22-tg1,up,t22,2n-spr,SYS-741GE-TNRT,???,10.30.51.55,10.30.50.55,3016.9,u30-u33 -s56-t23-sut1,up,t23,2n-spr,SYS-741GE-TNRT,???,10.30.51.56,10.30.50.56,3016.9,u26-u29 -s57-t23-tg1,up,t23,2n-spr,SYS-741GE-TNRT,???,10.30.51.57,10.30.50.57,3016.9,u22-u25 -s25-t25-sut1,down,t25,2n-p1,SYS-7049GP-TRT,C7470KH06A20022,10.30.51.61,10.30.50.58,3016.9,u18-u21 -s19-t33t211-tg1,up,t33t211,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51.49,10.30.50.46,3016.9,u14-u17 -s27-t211-sut1,up,t211,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13 -s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.37,10.30.50.37,3016.9,u11-u12 -s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.36,10.30.50.36,3016.9,u9-u10 -s79-t39t310-tg1,in-transit,t39t310,tbd,SYS-740GP-TNRT,???,10.30.51.89,10.30.50.89,3016.9,u5-u8 - -#### Rack YUL1-10 (3016.10) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-10-lb4m,up,switch,uplink,?,?,?,?,3016.10,u47,?,? -s2-t12-sut1,up,t12,1n-skx,SYS-7049GP-TRT,C7470KH06A20119,10.30.51.51,10.30.50.48,3016.10,u42-u45 -s1-t11-sut1,up,t11,1n-skx,SYS-7049GP-TRT,C7470KH06A20154,10.30.51.50,10.30.50.47,3016.10,u38-u41 -s58-t24-sut1,up,t24,2n-spr,SYS-741GE-TNRT,???,10.30.51.58,10.30.50.58,3016.10,u34-u37 -s59-t24-tg1,up,t24,2n-spr,SYS-741GE-TNRT,???,10.30.51.59,10.30.50.59,3016.10,u30-u33 -s93-t39-sut1,up,t39,3n-snr,?,?,10.30.51.93,10.30.50.93,3016.10,u10-u13 -s94-t39-sut2,up,t39,3n-snr,?,?,10.30.51.94,10.30.50.94,3016.10,u6-u9 -s89-t39t310-tg1,up,t39,3n-snr,?,?,10.30.51.89,10.30.50.89,3016.10,u2-u5 - -#### Rack YUL1-11 (3016.11) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-11-lb6m,up,switch,arm-uplink,?,?,?,?,3016.11,u48 -yul1-11-lf-tor-switch,up,switch,uplink,?,?,?,?,3016.11,u47 -mtl1-6-7050QX-32,up,switch,uplink,?,?,?,?,3016.11,u46 -fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,10.30.51.38,10.30.50.38,3016.11,u45 -s56-t14-sut1,up,t14,1n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u41-u42 -s78-t38-sut1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50450,10.30.51.78,10.30.50.78,3016.11,u31-u34 -s79-t38-sut2,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL07P50297,10.30.51.79,10.30.50.79,3016.11,u27-u30 -s80-t38-tg1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50454,10.30.51.80,10.30.50.80,3016.11,u23-u26 -s55-t13-sut1,up,t13,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12 -s62-t34-sut1,up,t34,3n-alt,WIWYNN,04000059N0SC,10.30.51.72,10.30.50.72,3016.11,u9-u10 -s63-t34-sut2,up,t34,3n-alt,WIWYNN,0390003EN0SC,10.30.51.73,10.30.50.73,3016.11,u7-u8 -s64-t34-tg1,up,t34,3n-alt,SYS-740GP-TNRT,C7470KK40P50249,10.30.51.74,10.30.50.74,3016.11,u3-u6 - -#### Rack YUL1-12 (3016.12) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-12-lb4m,up,switch,uplink,?,?,?,?,3016.12,u47 -s28-nomad,up,nomad-cluster1.nomad-client,SYS-7049GP-TRT,C7470KH06A20196,10.30.51.28,10.30.50.28,3016.12,u41-u44 -s27-nomad,up,nomad-cluster1,nomad-client,SYS-7049GP-TRT,C7470KH06A20055,10.30.51.27,10.30.50.27,3016.12,u37-u40 -s91-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0016,10.30.51.91,10.30.50.91,3016.12,u36 -s92-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0004,10.30.51.92,10.30.50.92,3016.12,u35 -s23-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0256,10.30.51.23,10.30.51.23,3016.12,u34 -s24-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0241,10.30.51.24,10.30.51.24,3016.12,u33 -s25-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0540,10.30.51.25,10.30.51.25,3016.12,u32 -s61-t210-tg1,up,t210,2n-zn2,AS-1014S-WTRT,C8150LI50NS2689,10.32.8.25,10.30.55.25,3016.12,u31 -s60-t210-sut1,up,t210,2n-zn2,AS-1114S-WTRT,N/A,10.32.8.24,10.30.55.24,3016.12,u30 -s26-nomad,up,nomad-cluster1,nomad-server,SYS-7049GP-TRT,C7470KH37A30505,10.30.51.26,10.30.51.26,3016.12,u26-u29 -s33-t27-sut1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30567,10.32.8.18,10.30.55.18,3016.12,u22-u25 -s34-t27-tg1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30565,10.32.8.19,10.30.55.19,3016.12,u18-u21 -s35-t28-sut1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30509,10.32.8.20,10.30.55.20,3016.12,u14-u17 -s36-t28-tg1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30511,10.32.8.21,10.30.55.21,3016.12,u10-u13 -s37-t29-sut1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30566,10.32.8.22,10.30.55.22,3016.12,u6-u9 -s38-t29-tg1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30506,10.32.8.23,10.30.55.23,3016.12,u2-u5 diff --git a/docs/lab/fdio-dc-physical.yaml b/docs/lab/fdio-dc-physical.yaml deleted file mode 100644 index cbcca02f76..0000000000 --- a/docs/lab/fdio-dc-physical.yaml +++ /dev/null @@ -1,462 +0,0 @@ ---- -# file: fdio-dc-physical.yaml - -yul1: - rack: - name: yul1-8 - facility_id: 3016.8 - tenant: Linux Foundation - status: active - dimensions: - type: 4-post cabinet - width: 19 inches - height: 48U - - unit: 47 - name: mtl1-8-lb4m - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - lom_type: N/A - - unit: 42..45 - name: s65-t37-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK25P50098 - mgmt_ip4: 10.30.51.75 - lom_ip4: 10.30.50.75 - - unit: 38..41 - name: s66-t37-sut2 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK33P50247 - mgmt_ip4: 10.30.51.76 - lom_ip4: 10.30.50.76 - - unit: 34..37 - name: s67-t37-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK25P50076 - mgmt_ip4: 10.30.51.77 - lom_ip4: 10.30.50.77 - - unit: 30..33 - name: s71-t212-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK25P50173 - mgmt_ip4: 10.30.51.81 - lom_ip4: 10.30.50.81 - - unit: 26..29 - name: s72-t212-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK33P50220 - mgmt_ip4: 10.30.51.82 - lom_ip4: 10.30.50.82 - - unit: 22..25 - name: s83-t213-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL07P50300 - mgmt_ip4: 10.30.51.83 - lom_ip4: 10.30.50.83 - - unit: 18..21 - name: s84-t213-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL03P50187 - mgmt_ip4: 10.30.51.84 - lom_ip4: 10.30.50.84 - - unit: 14..17 - name: s85-t214-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK33P50219 - mgmt_ip4: 10.30.51.85 - lom_ip4: 10.30.50.85 - - unit: 10..13 - name: s86-t214-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL07P50312 - mgmt_ip4: 10.30.51.86 - lom_ip4: 10.30.50.86 - - unit: 6..9 - name: s87-t215-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL03P50171 - mgmt_ip4: 10.30.51.87 - lom_ip4: 10.30.50.87 - - unit: 2..5 - name: s88-t215-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL07P50301 - mgmt_ip4: 10.30.51.88 - lom_ip4: 10.30.50.88 - name: yul1-9 - facility_id: 3016.9 - tenant: Linux Foundation - status: active - dimensions: - type: 4-post cabinet - width: 19 inches - height: 48U - - unit: 47 - name: mtl1-5-lb4m - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - lom_type: N/A - - unit: 42..45 - name: s52-t21-sut1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: C7490FL36A40118 - mgmt_ip4: 10.30.51.52 - lom_ip4: 10.30.50.52 - - unit: 38..41 - name: s53-t21-tg1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.53 - lom_ip4: 10.30.50.53 - - unit: 34..37 - name: s54-t22-sut1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.54 - lom_ip4: 10.30.50.54 - - unit: 30..33 - name: s55-t22-tg1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.55 - lom_ip4: 10.30.50.55 - - unit: 26..29 - name: s56-t23-sut1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.56 - lom_ip4: 10.30.50.56 - - unit: 22..25 - name: s57-t23-tg1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.57 - lom_ip4: 10.30.50.57 - - unit: 18..21 - name: s25-t25-sut1 - oper_status: stage - device_type: SYS-7049GP-TRT - serial_number: C7470KH06A20022 - mgmt_ip4: 10.30.51.61 - lom_ip4: 10.30.50.58 - - unit: 14..17 - name: s19-t33t211-tg1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH06A20056 - mgmt_ip4: 10.30.51.49 - lom_ip4: 10.30.50.46 - - unit: 13 - name: s27-t211-sut1 - oper_status: production - device_type: ThunderX2-9975 - serial_number: K61186073100003 - mgmt_ip4: 10.30.51.69 - lom_ip4: 10.30.50.69 - - unit: 11..12 - name: s18-t33-sut2 - oper_status: production - device_type: HUAWEI-TAISHAN-2280 - serial_number: N/A - mgmt_ip4: 10.30.51.37 - lom_ip4: 10.30.50.37 - - unit: 9..10 - name: s17-t33-sut1 - oper_status: production - device_type: HUAWEI-TAISHAN-2280 - serial_number: N/A - mgmt_ip4: 10.30.51.36 - lom_ip4: 10.30.50.36 -yul1: - rack: - name: yul1-10 - facility_id: 3016.10 - tenant: Linux Foundation - status: active - dimensions: - type: 4-post cabinet - width: 19 inches - height: 48U - - unit: 47 - name: yul1-10-lb4m - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - - unit: 42..45 - name: s2-t12-sut1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH06A20119 - mgmt_ip4: 10.30.51.51 - lom_ip4: 10.30.50.48 - - unit: 38..41 - name: s1-t11-sut1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH06A20154 - mgmt_ip4: 10.30.51.50 - lom_ip4: 10.30.50.47 - - unit: 34..37 - name: s58-t24-sut1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.58 - lom_ip4: 10.30.50.58 - - unit: 30..33 - name: s59-t24-tg1 - oper_status: production - device_type: SYS-741GE-TNRT - serial_number: ? - mgmt_ip4: 10.30.51.59 - lom_ip4: 10.30.50.59 - - unit: 10..13 - name: s93-t39-sut1 - oper_status: production - device_type: ? - serial_number: ? - mgmt_ip4: 10.30.51.93 - lom_ip4: 10.30.50.93 - - unit: 6..9 - name: s94-t39-sut2 - oper_status: production - device_type: ? - serial_number: ? - mgmt_ip4: 10.30.51.94 - lom_ip4: 10.30.50.94 - - unit: 2..5 - name: s89-t39t310-tg1 - oper_status: production - device_type: ? - serial_number: ? - mgmt_ip4: 10.30.51.89 - lom_ip4: 10.30.50.89 - rack: - name: yul1-11 - facility_id: 3016.11 - tenant: Linux Foundation - status: active - dimensions: - type: 4-post cabinet - width: 19 inches - height: 48U - - unit: 48 - name: yul1-11-lb6m - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - - unit: 47 - name: yul1-11-lf-tor-switch - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - - unit: 46 - name: mtl1-6-7050QX-32 - oper_status: production - device_type: switch - serial_number: N/A - mgmt_ip4: N/A - lom_ip4: N/A - - unit: 45 - name: fdio-marvell-dev - oper_status: production - device_type: ThunderX-88XX - serial_number: N/A - mgmt_ip4: 10.30.51.38 - lom_ip4: 10.30.50.38 - - unit: 41..42 - name: s56-t14-sut1 - oper_status: production - device_type: ThunderX2-9980 - serial_number: N/A - mgmt_ip4: 10.30.51.71 - lom_ip4: 10.30.50.71 - - unit: 31..34 - name: s78-t38-sut1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL03P50450 - mgmt_ip4: 10.30.51.78 - lom_ip4: 10.30.50.78 - - unit: 27..30 - name: s79-t38-sut2 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL07P50297 - mgmt_ip4: 10.30.51.79 - lom_ip4: 10.30.50.79 - - unit: 23..26 - name: s80-t38-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KL03P50454 - mgmt_ip4: 10.30.51.80 - lom_ip4: 10.30.50.80 - - unit: 11..12 - name: s55-t13-sut1 - oper_status: production - device_type: ThunderX2-9980 - serial_number: N/A - mgmt_ip4: 10.30.51.70 - lom_ip4: 10.30.50.70 - - unit: 9..10 - name: s62-t34-sut1 - oper_status: production - device_type: Mt.Jade Server System B81.030Z1.0007 - serial_number: 04000059N0SC - mgmt_ip4: 10.30.51.72 - lom_ip4: 10.30.50.72 - - unit: 7..8 - name: s63-t34-sut2 - oper_status: production - device_type: Mt.Jade Server System B81.030Z1.0007 - serial_number: 0390003EN0SC - mgmt_ip4: 10.30.51.73 - lom_ip4: 10.30.50.73 - - unit: 3..6 - name: s64-t34-tg1 - oper_status: production - device_type: SYS-740GP-TNRT - serial_number: C7470KK40P50249 - mgmt_ip4: 10.30.51.74 - lom_ip4: 10.30.50.74 - rack: - name: yul1-12 - facility_id: 3016.12 - tenant: Linux Foundation - status: active - dimensions: - type: 4-post cabinet - width: 19 inches - height: 48U - layout: - - unit: 47 - name: yul1-12-lb4m - oper_status: production - - unit: 36 - name: s58-nomad - oper_status: - device_type: R152-P30-00 - serial_number: GLG4P9912A0016 - mgmt_ip4: 10.30.51.91 - lom_ip4: 10.30.50.91 - - unit: 35 - name: s59-nomad - oper_status: - device_type: R152-P30-00 - serial_number: GLG4P9912A0004 - mgmt_ip4: 10.30.51.92 - lom_ip4: 10.30.50.92 - - unit: 34 - name: s23-nomad - oper_status: production - device_type: SYS-1029P-WTRT - serial_number: C1160LI12NM0256 - mgmt_ip4: 10.30.51.23 - lom_ip4: 10.30.51.23 - - unit: 33 - name: s24-nomad - oper_status: production - device_type: SYS-1029P-WTRT - serial_number: C1160LI12NM0241 - mgmt_ip4: 10.30.51.24 - lom_ip4: 10.30.51.24 - - unit: 32 - name: s25-nomad - oper_status: production - device_type: SYS-1029P-WTRT - serial_number: C1160LI12NM0540 - mgmt_ip4: 10.30.51.25 - lom_ip4: 10.30.51.25 - - unit: 31 - name: s61-t210-tg1 - oper_status: production - device_type: AS-1014S-WTRT - serial_number: C8150LI50NS2689 - mgmt_ip4: 10.32.8.25 - lom_ip4: 10.30.55.25 - - unit: 30 - name: s60-t210-sut1 - oper_status: production - device_type: AS-1114S-WTRT - serial_number: N/A - mgmt_ip4: 10.32.8.24 - lom_ip4: 10.30.55.24 - - unit: 26..29 - name: s26-nomad - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30505 - mgmt_ip4: 10.30.51.26 - lom_ip4: 10.30.51.26 - - unit: 22..25 - name: s33-t27-sut1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30567 - mgmt_ip4: 10.32.8.18 - lom_ip4: 10.30.55.18 - - unit: 18..21 - name: s34-t27-tg1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30565 - mgmt_ip4: 10.32.8.19 - lom_ip4: 10.30.55.19 - - unit: 14..17 - name: s35-t28-sut1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30509 - mgmt_ip4: 10.32.8.20 - lom_ip4: 10.30.55.20 - - unit: 10..13 - name: s36-t28-tg1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30511 - mgmt_ip4: 10.32.8.21 - lom_ip4: 10.30.55.21 - - unit: 6..9 - name: s37-t29-sut1 - oper_status: production - device_type: SYS-7049GP-TRT - serial_number: C7470KH37A30566 - mgmt_ip4: 10.32.8.22 - lom_ip4: 10.30.55.22 - lom_type: ipmi - - unit: 2..5 - name: s38-t29-tg1 - oper_status: production - model: SYS-7049GP-TRT - serial_number: C7470KH37A30506 - mgmt_ip4: 10.32.8.23 - ilo_ip4: 10.30.55.23 \ No newline at end of file diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md deleted file mode 100644 index fc59465569..0000000000 --- a/docs/lab/testbed_specifications.md +++ /dev/null @@ -1,1879 +0,0 @@ -# FD.io CSIT Testbed Specifications - -1. [Purpose](#purpose) -1. [Testbeds Overview](#testbeds-overview) - 1. [Summary List](#summary-list) - 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) - 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) - 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) - 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) - 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) - 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) - 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) - 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) - 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) - 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) - 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) - 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx) - 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr) - 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr) - 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr) -1. [Server Management](#server-management) - 1. [Addressing](#addressing) -1. [Server Specifications](#server-specifications) - 1. [Server Types](#server-types) - 1. [Naming Convention](#naming-convention) -1. [Testbeds Configuration](#testbeds-configuration) - 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) - 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) - 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) - 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) - 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) - 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) - 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) - 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) - 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) - 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) - 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod) - 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod) - 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod) - 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod) - 1. [Per Testbed Wiring](#per-testbed-wiring) - 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) - 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) - 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) - 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) - 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) - 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) - 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) - 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo) - 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) - 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod) - 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod) - 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod) - 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod) - -## Purpose - -This note includes specification of the physical testbed infrastructure -hosted by LFN FD.io CSIT project. - -## Testbeds Overview - -### Summary List - -``` - #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr - 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 - 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 - 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 - 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 - 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 - 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 -10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 -11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 -12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 -13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 -13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 - Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 -``` - -### 1-Node-Skylake Xeon Intel (1n-skx) - -Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC -ports connected back-to-back ([Server Types](#server-types)). -Used for FD.io VPP_Device functional driver tests. - -### 1-Node-ThunderX2 Arm Marvell (1n-tx2) - -Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC -ports connected back-to-back ([Server Types](#server-types)). -Used for FD.io VPP_Device functional driver tests. - -### 1-Node-Cascadelake Xeon Intel (1n-clx) - -Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with -NIC ports connected back-to-back ([Server Types](#server-types)). - -Used for FD.io VPP_Device functional driver tests. - -### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) - -Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one -TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node -circular topology ([Server Types](#server-types)). -Used for FD.io TCP/IP and HTTP performance tests. - -### 2-Node-Cascadelake Xeon Intel (2n-clx) - -Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and -one TG (Server-Type-C3) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Zen2 EPYC AMD (2n-zn2) - -Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and -one TG (Server-Type-D2) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-ThunderX2 Arm Marvell (2x-tx2) - -Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and -one TG (Server-Type-E31) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Icelake Xeon Intel (2n-icx) - -Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and -one TG (Server-Type-F2) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Rangeley Atom Testbeds - -Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one -TG (Server-Type-2) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-TaiShan Arm Huawei (3n-tsh) - -Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one -TG (Server-Type-E31) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Altra Arm Ampere (3n-alt) - -Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one -TG (Server-Type-F4) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Icelake Xeon Intel (3n-icx) - -Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one -TG (Server-Type-F3) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-SnowRidge Atom Intel (3n-snr) - -Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one -TG (Server-Type-F4) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) - -One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and -one TG (Server-Type-H2) connected in a 2-node physical topology -with NUMA (socket) daisy chaining. For more detail see -[Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests in a full system SUT setup with all PCIe -Gen5 x16 lane slots populated with 2p200GbE NICs. - -### 2-Node-SapphireRapids Xeon Intel (2n-spr) - -Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and -one TG (Server-Type-H6) connected in a 2-node circular topology. For more -detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests. - -## Server Management - -### Addressing - -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a -Management port, which are connected to two different VLANs. - -``` -1. LOM (IPMI) VLAN: - - Subnet: 10.30.50.0/24 - - Gateway: 10.30.50.1 - - Broadcast: 10.30.50.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -2. Management Vlan: - - Subnet: 10.30.51.0/24 - - Gateway: 10.30.51.1 - - Broadcast: 10.30.51.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -``` - -To access these hosts, VPN connection is required. - -## Server Specifications - -### Server Types - -FD.io CSIT lab contains following server types: -``` -1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: empty. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - - Quantity: 1. - - Physical connectivity: - - Host management interface: 10/100/1000-BaseT. - - 8-port 10GE SFP+ integrated NIC. - - Main HW configuration: - - Chassis: PS10GE4NG. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: Quad-Core, Intel Processor. - - HW accelerators: FPGA offload. - - RAM Memory: 64GB. - - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - - Physical Interfaces: 4 * 10GE SFP+. - - Operating System: Native IxOS. - - Interface configuration: - - Port-1: 10GE SFP+. - - Port-2: 10GE SFP+. - - Port-3: 10GE SFP+. - - Port-4: 10GE SFP+. -4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - - Quantity: 3 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Gold 6252N 2.3 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot10 d8:00.xx: empty. -8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - no NIC ports, standalone setup. - - Main HW configuration: - - Chassis: SuperMicro 1029P-WTRT. - - Motherboard: SuperMicro X11DDW-NT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 4* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: - - no cards. - - Numa1: - - no cards. -9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro AS-1114S-WTRT - - Processors: 1* AMD EPYC 7532 2.4 GHz. - - RAM Memory: 8* 32GB DDR4-2933. - - Disks: 1* 1TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro AS-1114S-WTRT - - Processors: 1* AMD EPYC 7532 2.4 GHz. - - RAM Memory: 8* 32GB DDR4-2933. - - Disks: 1* 1TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. -11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: GIGABYTE Rack Mount - - Motherboard: MT91-FS4-00 - - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - - RAM Memory: 16 * 16GB DIMM - - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - NICs configuration: - - Numa0: - - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - - Numa1: - - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. -12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI(?) and host management ports. - - NIC ports connected into 3-node topology. - - Main HW configuration: - - Chassis: Huawei TaiShan 2280. - - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - - RAM Memory: 8* 16GB DDR4-2400MT/s - - Disks: 1* 4TB SATA HDD - - NICs configuration: - - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node topologies. - - Main HW configuration: - - Chassis: Gigabyte R181-T90 1U - - Motherboard: MT91-FS1 - - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - - RAM Memory: 4* 32GB RDIMM - - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - - NICs configuration: - - Numa0: - - no cards - - Numa1: - - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node topologies. - - Main HW configuration: - - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U - - Motherboard: Mt.Jade Motherboard - - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 - - RAM Memory: 16* 8GB DDR4-3200MT/s - - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - - NICs configuration: - - Numa0: - - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - - Numa1: - - no cards. -15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: Gigabyte R152-P30-00 1U - - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - - RAM Memory: 12* 16GB DDR4-3200MT/s - - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. - - Quantity: 8. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node or 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and/or 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 d8:00.xx: empty. -21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node testbed topology. - - Main HW configuration: - - Chassis: Intel JACOBSVILLE SDP. - - Motherboard: Intel JACOBSVILLE E63448-400. - - Processors: 1* Intel Atom P5362B 2.2 GHz. - - RAM Memory: 2* 16GB DDR4-2933. - - Disks: ?* ? SATA SSD. - - NICs configuration: - - Numa0: (x16, PCIe3.0 lane) - - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot11 d8:00.xx: empty. -24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot10 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot11 d8:00.xx: empty. -25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot10 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: empty. - - PCIe Slot9 af:00.xx: empty. - - PCIe Slot11 d8:00.xx: empty. -26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: empty. - - PCIe Slot9 af:00.xx: empty. - - PCIe Slot11 d8:00.xx: empty. -27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot11 d8:00.xx: empty. -``` - -### Naming Convention - -Following naming convention is used within this page to specify physical -connectivity and wiring across defined CSIT testbeds: - -``` -- testbedname: testbedN. -- hostname: - - traffic-generator: tN-tgW. - - system-under-testX: tN-sutX. -- portnames: - - tN-tgW-cY/pZ. - - tN-sutX-cY/pZ. -- where: - - N - testbed number. - - tgW - server acts as traffic-generator with W index. - - sutX - server acts as system-under-test with X index. - - Y - PCIe slot number denoting a NIC card number within the host. - - Z - port number on the NIC card. -``` - -## Testbeds Configuration - -### Per Testbed Server Allocation and Naming - -#### 1-Node-Skylake Servers (1n-skx) PROD - -``` -- SUT [Server-Type-B6]: - - testbedname: testbed11. - - hostname: s1-t11-sut1. - - IPMI IP: 10.30.50.47 - - Host IP: 10.30.51.50 - - portnames: - - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B6]: - - testbedname: testbed12. - - hostname: s2-t12-sut1. - - IPMI IP: 10.30.50.48 - - Host IP: 10.30.51.51 - - portnames: - - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 1-Node-ThunderX2 Servers (1n-tx2) PROD - -``` -- SUT [Server-Type-E11]: - - testbedname: testbed13 - - hostname: s55-t13-sut1 - - IPMI IP: 10.30.50.70 - - Host IP: 10.30.51.70 - - portnames: - - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -- SUT [Server-Type-E11]: - - testbedname: testbed14 - - hostname: s56-t14-sut1 - - IPMI IP: 10.30.50.71 - - Host IP: 10.30.51.71 - - portnames: - - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -``` - -#### 1-Node-Cascadelake Servers (1n-clx) PROD - -``` -- SUT [Server-Type-C1]: - - testbedname: testbed11. - - hostname: s32-t14-sut1. - - IPMI IP: 10.30.55.17 - - Host IP: 10.32.8.17 - - portnames: - - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY - -``` -- SUT [Server-Type-B8]: - - testbedname: testbed25. - - hostname: s25-t25-sut1. - - IPMI IP: 10.30.50.58 - - Host IP: 10.30.51.61 - - portnames: - - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. -- TG [Server-Type-B7]: - - testbedname: testbed25. - - hostname: s26-t25-tg1. - - IPMI IP: 10.30.50.59 - - Host IP: 10.30.51.62 - - portnames: - - s26-t25-tg1-p1 - 10GE-port1. - - s26-t25-tg1-p2 - 10GE-port2. - - s26-t25-tg1-p3 - 10GE-port3. - - s26-t25-tg1-p4 - 10GE-port4. -``` - -#### 2-Node-Cascadelake Servers (2n-clx) PROD - -``` -- SUT [Server-Type-C2]: - - testbedname: testbed27. - - hostname: s33-t27-sut1. - - IPMI IP: 10.30.55.18 - - Host IP: 10.32.8.18 - - portnames: - - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed27. - - hostname: s34-t27-tg1. - - IPMI IP: 10.30.55.19 - - Host IP: 10.32.8.19 - - portnames: - - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- SUT [Server-Type-C2]: - - testbedname: testbed28. - - hostname: s35-t28-sut1. - - IPMI IP: 10.30.55.20 - - Host IP: 10.32.8.20 - - portnames: - - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed28. - - hostname: s36-t28-tg1. - - IPMI IP: 10.30.55.21 - - Host IP: 10.32.8.21 - - portnames: - - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- SUT [Server-Type-C2]: - - testbedname: testbed29. - - hostname: s37-t29-sut1. - - IPMI IP: 10.30.55.22 - - Host IP: 10.32.8.22 - - portnames: - - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed29. - - hostname: s38-t29-tg1. - - IPMI IP: 10.30.55.23 - - Host IP: 10.32.8.23 - - portnames: - - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -``` - -#### 2-Node-Zen2 Servers (2n-zn2) PROD - -``` -- SUT [Server-Type-D1]: - - testbedname: testbed210. - - hostname: s60-t210-sut1. - - IPMI IP: 10.30.55.24 - - Host IP: 10.32.8.24 - - portnames: - - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. - - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. - - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. - - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. - - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. - - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-D2]: - - testbedname: testbed210. - - hostname: s61-t210-tg1. - - IPMI IP: 10.30.55.25 - - Host IP: 10.32.8.25 - - portnames: - - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. - - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. - - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. -``` - -#### 2-Node-ThunderX2 Servers (2x-tx2) PROD - -Note: Server19 (TG) is shared between testbed33 & testbed211 - -``` -- SUT [Server-Type-E22]: - - testbedname: testbed211. - - hostname: s27-t211-sut1. - - IPMI IP: 10.30.50.69 - - Host IP: 10.30.51.69 - - portnames: - - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. -- TG [Server-Type-E31]: - - testbedname: testbed33 and testbed211. - - hostname: s19-t33t211-tg1. - - IPMI IP: 10.30.50.46 - - Host IP: 10.30.51.49 - - portnames: - - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 2-Node-Icelake Servers (2n-icx) PROD - -``` -- SUT [Server-Type-F1]: - - testbedname: testbed212. - - hostname: s71-t212-sut1. - - IPMI IP: 10.30.50.81 - - Host IP: 10.30.51.81 - - portnames: - - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed212. - - hostname: s72-t212-tg1. - - IPMI IP: 10.30.50.82 - - Host IP: 10.30.51.82 - - portnames: - - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed213. - - hostname: s83-t213-sut1. - - IPMI IP: 10.30.50.83 - - Host IP: 10.30.51.83 - - portnames: - - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed213. - - hostname: s84-t213-tg1. - - IPMI IP: 10.30.50.84 - - Host IP: 10.30.51.84 - - portnames: - - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed214. - - hostname: s85-t214-sut1. - - IPMI IP: 10.30.50.85 - - Host IP: 10.30.51.85 - - portnames: - - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed214. - - hostname: s86-t214-tg1. - - IPMI IP: 10.30.50.86 - - Host IP: 10.30.51.86 - - portnames: - - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed215. - - hostname: s87-t215-sut1. - - IPMI IP: 10.30.50.87 - - Host IP: 10.30.51.87 - - portnames: - - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed215. - - hostname: s88-t215-tg1. - - IPMI IP: 10.30.50.88 - - Host IP: 10.30.51.88 - - portnames: - - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-Rangeley Servers (3n-rng) VERIFY - -Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - -``` -- ServerB22 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 - - Host IP: 10.30.51.9 - - portnames: - - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB23 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 - - Host IP: 10.30.51.10 - - portnames: - - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB24 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 - - Host IP: 10.30.51.11 - - portnames: - - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -``` - -#### 3-Node-Taishan Servers (3n-tsh) PROD - -Note: Server19 (TG) is shared between testbed33 & testbed211 - -``` -- SUT [Server-Type-E21]: - - testbedname: testbed33. - - hostname: s17-t33-sut1. - - IPMI IP: 10.30.50.36 - - Host IP: 10.30.51.36 - - portnames: - - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE. - - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- SUT [Server-Type-E21]: - - testbedname: testbed33. - - hostname: s18-t33-sut2. - - IPMI IP: 10.30.50.37 - - Host IP: 10.30.51.37 - - portnames: - - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE. - - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- TG [Server-Type-E31]: - - testbedname: testbed33 and testbed211. - - hostname: s19-t33t211-tg1. - - IPMI IP: 10.30.50.46 - - Host IP: 10.30.51.49 - - portnames: - - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 3-Node-Altra Servers (3n-alt) PROD - -``` -- SUT [Server-Type-E23]: - - testbedname: testbed34. - - hostname: s62-t34-sut1. - - IPMI IP: 10.30.50.72 - - Host IP: 10.30.51.72 - - portnames: - - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. -- SUT [Server-Type-E23]: - - testbedname: testbed34. - - hostname: s63-t34-sut2. - - IPMI IP: 10.30.50.73 - - Host IP: 10.30.51.73 - - portnames: - - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. -- TG [Server-Type-F4]: - - testbedname: testbed34. - - hostname: s64-t34-tg1. - - IPMI IP: 10.30.50.74 - - Host IP: 10.30.51.74 - - portnames: - - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-Icelake Servers (3n-icx) PROD - -``` -- ServerF1 [Server-Type-F1]: - - testbedname: testbed37. - - hostname: s65-t37-sut1. - - IPMI IP: 10.30.50.75 - - Host IP: 10.30.51.75 - - portnames: - - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed37. - - hostname: s66-t37-sut2. - - IPMI IP: 10.30.50.76 - - Host IP: 10.30.51.76 - - portnames: - - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: - - testbedname: testbed37. - - hostname: s67-t37-tg1. - - IPMI IP: 10.30.50.77 - - Host IP: 10.30.51.77 - - portnames: - - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed38. - - hostname: s78-t38-sut1. - - IPMI IP: 10.30.50.78 - - Host IP: 10.30.51.78 - - portnames: - - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed38. - - hostname: s79-t38-sut2. - - IPMI IP: 10.30.50.79 - - Host IP: 10.30.51.79 - - portnames: - - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: - - testbedname: testbed38. - - hostname: s80-t38-tg1. - - IPMI IP: 10.30.50.80 - - Host IP: 10.30.51.80 - - portnames: - - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-SnowRidge Servers (3n-snr) PROD - -``` -- ServerG1 [Server-Type-G1]: - - testbedname: testbed39. - - hostname: s93-t39-sut1. - - IPMI IP: 10.30.50.93 - - Host IP: 10.30.51.93 - - portnames: - - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerG1 [Server-Type-G1]: - - testbedname: testbed39. - - hostname: s94-t39-sut2. - - IPMI IP: 10.30.50.94 - - Host IP: 10.30.51.94 - - portnames: - - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerF4 [Server-Type-F4]: - - testbedname: testbed39. - - hostname: s89-t39t310-tg1. - - IPMI IP: 10.30.50.89 - - Host IP: 10.30.51.89 - - portnames: - - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -``` - -#### 2-Node-SapphireRapids Servers (2n-spr) PROD - -``` -- SUT [Server-Type-H1]: - - testbedname: testbed21. - - hostname: s52-t21-sut1. - - IPMI IP: 10.30.50.52 - - Host IP: 10.30.51.52 - - portnames: - - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE. -- TG [Server-Type-H2]: - - testbedname: testbed21. - - hostname: s53-t21-tg1. - - IPMI IP: 10.30.50.53 - - Host IP: 10.30.51.53 - - portnames: - - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. -- SUT [Server-Type-H3]: - - testbedname: testbed22. - - hostname: s54-t22-sut1. - - IPMI IP: 10.30.50.54 - - Host IP: 10.30.51.54 - - portnames: - - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H4]: - - testbedname: testbed22. - - hostname: s55-t22-tg1. - - IPMI IP: 10.30.50.55 - - Host IP: 10.30.51.55 - - portnames: - - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- SUT [Server-Type-H5]: - - testbedname: testbed23. - - hostname: s56-t23-sut1. - - IPMI IP: 10.30.50.56 - - Host IP: 10.30.51.56 - - portnames: - - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H6]: - - testbedname: testbed23. - - hostname: s57-t23-tg1. - - IPMI IP: 10.30.50.57 - - Host IP: 10.30.51.57 - - portnames: - - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-H5]: - - testbedname: testbed24. - - hostname: s58-t24-sut1. - - IPMI IP: 10.30.50.58 - - Host IP: 10.30.51.58 - - portnames: - - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H6]: - - testbedname: testbed24. - - hostname: s59-t24-tg1. - - IPMI IP: 10.30.50.59 - - Host IP: 10.30.51.59 - - portnames: - - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -### Per Testbed Wiring - -#### 1-Node-Skylake Wiring (1n-skx) PROD - -``` -- testbed11: - - ring1 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. - - ring2 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. - - ring3 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - - ring4 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. - - ring5 100GE-ports e810-2p100GE: - - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. - - ring6 100GE-ports e810-2p100GE: - - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. -- testbed12: - - ring1 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. - - ring2 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. - - ring3 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - - ring4 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. - - ring5 100GE-ports e810-2p100GE: - - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. - - ring6 100GE-ports e810-2p100GE: - - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. -``` - -#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD - -``` -- testbed13: - - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. - - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. - -- testbed14: - - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. - - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. - - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. -``` - -#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY - -``` -- testbed25: - - link1 10GE-port x710-4p10GE on SUT: - - t25-tg1-p1 to t25-sut1-c2/p1. - - link2 10GE-port x710-4p10GE on SUT: - - t25-tg1-p2 to t25-sut1-c2/p2. - - link3 10GE-port x710-4p10GE on SUT: - - t25-tg1-p3 to t25-sut1-c2/p3. - - link4 10GE-port x710-4p10GE on SUT: - - t25-tg1-p4 to t25-sut1-c2/p4. -``` - -#### 2-Node-Cascadelake Wiring (2n-clx) PROD - -``` -- testbed27: - - ring1 10GE-ports x710-4p10GE on SUT: - - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. - - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. - - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. - - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. - - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. - - ring6 100GE-ports e810-2p100GE on TG: - - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. - - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. -- testbed28: - - ring1 10GE-ports x710-4p10GE on SUT: - - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. - - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. - - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. - - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. - - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. - - ring6 100GE-ports e810-2p100GE on TG: - - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. - - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. -- testbed29: - - ring1 10GE-ports x710-4p10GE on SUT: - - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. - - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. - - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. - - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. - - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. -``` - -#### 2-Node-Zen2 Wiring (2n-zn2) PROD - -``` -- testbed210: - - ring1 10GE-ports x710-4p10GE on SUT: - - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. - - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. - - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. - - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. - - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. -``` - -#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD - -``` -- testbed211: - - ring1 10GE-ports x520-2p10GE on SUTs: - - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. - - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. -``` - -#### 2-Node-Icelake Wiring (2n-icx) PROD - -``` -- testbed212: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. - - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. - - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. - - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. - - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. - - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. -- testbed213: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. - - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. - - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. - - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. - - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. - - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. -- testbed214: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. - - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. - - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. - - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. - - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. - - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. -- testbed215: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. - - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. - - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. - - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. - - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. - - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. -``` - -#### 3-Node-Rangeley Wiring (3n-rng) VERIFY - -``` -To be completed. -``` - -#### 3-Node-Taishan Wiring (3n-tsh) PROD - -``` -- testbed33: - - ring1 10GE-ports x520-2p10GE on SUTs: - - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. - - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. - - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - - ring2 25GE-ports cx4-2p25GE on SUTs: - - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. - - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. - - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. -``` - -#### 3-Node-Altra Wiring (3n-alt) PROD - -``` -- testbed34: - - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: - - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. - - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. - - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. -``` - -#### 3-Node-Icelake Wiring (3n-icx) PROD - -``` -- testbed37: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. - - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. - - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. - - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. - - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. - - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. - - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. - - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. -- testbed38: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. - - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. - - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. - - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. - - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. - - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. - - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. - - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. -``` - -#### 3-Node-SnowRidge Wiring (3n-snr) PROD - -``` -- testbed39: - - ring1 25GE-ports e810-XXVDA4-4p25GE: - - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. - - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. - - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. - - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3. - - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4. - - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. -``` - -#### 2-Node-SapphireRapids Wiring (2n-spr) PROD - -``` -- testbed21: - - ring1 200GE-ports ConnectX7-2p200GE: - - s52-t21-tg1-c2/p1 to s53-t21-sut1-c2/p1 - - s52-t21-tg1-c7/p1 to s53-t21-sut1-c7/p1 - - s53-t21-sut1-c4/p2 to s53-t21-sut1-c9/p2 - - ring2 200GE-ports ConnectX7-2p200GE: - - s52-t21-tg1-c2/p2 to s53-t21-sut1-c2/p2 - - s52-t21-tg1-c7/p2 to s53-t21-sut1-c7/p2 - - s53-t21-sut1-c10/p1 to s53-t21-sut1-c11/p1 - - ring3 200GE-ports ConnectX7-2p200GE: - - s52-t21-tg1-c4/p1 to s53-t21-sut1-c4/p1 - - s52-t21-tg1-c9/p1 to s53-t21-sut1-c9/p1 - - s53-t21-sut1-c10/p2 to s53-t21-sut1-c11/p2 -- testbed22: - - ring1 100GE-ports e810-2CQDA2-2p100GE: - - s54-t22-tg1-c2/p1 to s55-t22-sut1-c2/p1 - - s54-t22-tg1-c2/p2 to s55-t22-sut1-c7/p1 - - s54-t22-sut1-c2/p2 to s55-t22-sut1-c7/p2 - - ring2 25GE-ports e810-XXVDA4-4p25GE: - - s54-t22-tg1-c4/p1 to s55-t22-sut1-c4/p1 - - s54-t22-tg1-c4/p2 to s55-t22-sut1-c9/p1 - - s54-t22-sut1-c4/p2 to s55-t22-sut1-c9/p2 -- testbed23: - - ring1 200GE-ports ConnectX7-2p200GE: - - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1. - - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2. - - ring2 100GE-ports e810-2CQDA2-2p100GE: - - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. - - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: - - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. - - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. - - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. - - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4. - - ring4 200GE-ports ConnectX7-2p200GE: - - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2. - - ring5 100GE-ports e810-2CQDA2-2p100GE: - - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2. -- testbed24: - - ring1 200GE-ports ConnectX7-2p200GE: - - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1. - - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2. - - ring2 100GE-ports e810-2CQDA2-2p100GE: - - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. - - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: - - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. - - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. - - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. - - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4. - - ring4 200GE-ports ConnectX7-2p200GE: - - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. - - ring5 100GE-ports e810-2CQDA2-2p100GE: - - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. -``` \ No newline at end of file diff --git a/docs/lab/testbeds_sm_clx_hw_bios_cfg.md b/docs/lab/testbeds_sm_clx_hw_bios_cfg.md deleted file mode 100644 index 4b22d09325..0000000000 --- a/docs/lab/testbeds_sm_clx_hw_bios_cfg.md +++ /dev/null @@ -1,1439 +0,0 @@ -# SuperMicro Cascadelake Servers - HW and BIOS Configuration - -1. [Linux lscpu](#linux-lscpu) -1. [Linux dmidecode](#dmidecode) -1. [Linux dmidecode pci](#linux-dmidecode-pci) -1. [Linux dmidecode memory](#linux-dmidecode-memory) -1. [Xeon Clx Server BIOS Configuration](#xeon-clx-server-bios-configuration) - 1. [Boot Feature](#boot-feature) - 1. [CPU Configuration](#cpu-configuration) - 1. [Advanced Power Management Configuration](#advanced-power-management-configuration) - 1. [CPU P State Control](#cpu-p-state-control) - 1. [Hardware PM State Control](#hardware-pm-state-control) - 1. [CPU C State Control](#cpu-c-state-control) - 1. [Package C State Control](#package-c-state-control) - 1. [CPU T State Control](#cpu-t-state-control) - 1. [Chipset Configuration](#chipset-configuration) - 1. [North Bridge](#north-bridge) - 1. [UPI Configuration](#upi-configuration) - 1. [Memory Configuration](#memory-configuration) - 1. [IIO Configuration](#iio-configuration) - 1. [CPU1 Configuration](#cpu1-configuration) - 1. [CPU2 Configuration](#cpu2-configuration) - 1. [South Bridge](#south-bridge) - 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration) - 1. [ACPI Settings](#acpi-settings) -1. [Xeon Clx Server Firmware Inventory](#xeon-clx-server-firmware-inventory) - -## Linux lscpu - -``` -Architecture: x86_64 -CPU op-mode(s): 32-bit, 64-bit -Byte Order: Little Endian -CPU(s): 112 -On-line CPU(s) list: 0-111 -Thread(s) per core: 2 -Core(s) per socket: 28 -Socket(s): 2 -NUMA node(s): 2 -Vendor ID: GenuineIntel -CPU family: 6 -Model: 85 -Model name: Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz -Stepping: 7 -CPU MHz: 3299.609 -BogoMIPS: 5400.00 -Virtualization: VT-x -L1d cache: 32K -L1i cache: 32K -L2 cache: 1024K -L3 cache: 39424K -NUMA node0 CPU(s): 0-27,56-83 -NUMA node1 CPU(s): 28-55,84-111 -Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca -cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx -pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology -nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est -tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt -tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch -cpuid_fault epb cat_l3 cdp_l3 invpcid_single ssbd mba ibrs ibpb stibp -ibrs_enhanced tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 -hle avx2 smep bmi2 erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx -smap clflushopt clwb intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1 -xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts -pku ospke avx512_vnni md_clear flush_l1d arch_capabilities -``` - -``` -Architecture: x86_64 -CPU op-mode(s): 32-bit, 64-bit -Byte Order: Little Endian -CPU(s): 96 -On-line CPU(s) list: 0-95 -Thread(s) per core: 2 -Core(s) per socket: 24 -Socket(s): 2 -NUMA node(s): 2 -Vendor ID: GenuineIntel -CPU family: 6 -Model: 85 -Model name: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz -Stepping: 7 -CPU MHz: 3000.989 -BogoMIPS: 4600.00 -Virtualization: VT-x -L1d cache: 32K -L1i cache: 32K -L2 cache: 1024K -L3 cache: 36608K -NUMA node0 CPU(s): 0-23,48-71 -NUMA node1 CPU(s): 24-47,72-95 -Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca -cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx -pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology -nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 -ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt -tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch -cpuid_fault epb cat_l3 cdp_l3 invpcid_single ssbd mba ibrs ibpb stibp -ibrs_enhanced tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 hle -avx2 smep bmi2 erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx smap -clflushopt clwb intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1 -xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts -pku ospke avx512_vnni md_clear flush_l1d arch_capabilities -``` - -## Linux dmidecode - -``` - # dmidecode 3.1 - Getting SMBIOS data from sysfs. - SMBIOS 3.1.2 present. - Table at 0x6EB92000. - - Handle 0x0000, DMI type 0, 26 bytes - BIOS Information - Vendor: American Megatrends Inc. - Version: 3.0c - Release Date: 03/27/2019 - Address: 0xF0000 - Runtime Size: 64 kB - ROM Size: 32 MB - Characteristics: - PCI is supported - BIOS is upgradeable - BIOS shadowing is allowed - Boot from CD is supported - Selectable boot is supported - BIOS ROM is socketed - EDD is supported - 5.25"/1.2 MB floppy services are supported (int 13h) - 3.5"/720 kB floppy services are supported (int 13h) - 3.5"/2.88 MB floppy services are supported (int 13h) - Print screen service is supported (int 5h) - Serial services are supported (int 14h) - Printer services are supported (int 17h) - ACPI is supported - USB legacy is supported - BIOS boot specification is supported - Targeted content distribution is supported - UEFI is supported - BIOS Revision: 5.14 - - Handle 0x0001, DMI type 1, 27 bytes - System Information - Manufacturer: Supermicro - Product Name: SYS-7049GP-TRT - Version: 0123456789 - Serial Number: S291427X9525476 - UUID: 00000000-0000-0000-0000-AC1F6BACD7BA - Wake-up Type: Power Switch - SKU Number: To be filled by O.E.M. - Family: To be filled by O.E.M. - - Handle 0x0002, DMI type 2, 15 bytes - Base Board Information - Manufacturer: Supermicro - Product Name: X11DPG-QT - Version: 1.10A - Serial Number: VM189S007860 - Asset Tag: To be filled by O.E.M. - Features: - Board is a hosting board - Board is replaceable - Location In Chassis: To be filled by O.E.M. - Chassis Handle: 0x0003 - Type: Motherboard - Contained Object Handles: 0 - - Handle 0x0003, DMI type 3, 22 bytes - Chassis Information - Manufacturer: Supermicro - Type: Other - Lock: Not Present - Version: 0123456789 - Serial Number: C7470KH37A30566 - Asset Tag: To be filled by O.E.M. - Boot-up State: Safe - Power Supply State: Safe - Thermal State: Safe - Security Status: None - OEM Information: 0x00000000 - Height: Unspecified - Number Of Power Cords: 1 - Contained Elements: 0 - SKU Number: To be filled by O.E.M. - - Handle 0x0055, DMI type 4, 48 bytes - Processor Information - Socket Designation: CPU1 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: 57 06 05 00 FF FB EB BF - Signature: Type 0, Family 6, Model 85, Stepping 7 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4500 MHz - Current Speed: 2300 MHz - Status: Populated, Enabled - Upgrade: Socket LGA3647-1 - L1 Cache Handle: 0x0052 - L2 Cache Handle: 0x0053 - L3 Cache Handle: 0x0054 - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 24 - Core Enabled: 24 - Thread Count: 48 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control - - Handle 0x0059, DMI type 4, 48 bytes - Processor Information - Socket Designation: CPU2 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: 57 06 05 00 FF FB EB BF - Signature: Type 0, Family 6, Model 85, Stepping 7 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4500 MHz - Current Speed: 2300 MHz - Status: Populated, Enabled - Upgrade: Socket LGA3647-1 - L1 Cache Handle: 0x0056 - L2 Cache Handle: 0x0057 - L3 Cache Handle: 0x0058 - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 24 - Core Enabled: 24 - Thread Count: 48 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control -``` - -## Linux dmidecode pci - -``` - Handle 0x000B, DMI type 9, 17 bytes - System Slot Information - Designation: CPU1 SLOT2 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: In Use - Length: Long - ID: 2 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:18:00.0 - - Handle 0x000C, DMI type 9, 17 bytes - System Slot Information - Designation: CPU1 SLOT4 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: In Use - Length: Short - ID: 4 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:3b:00.0 - - Handle 0x000D, DMI type 9, 17 bytes - System Slot Information - Designation: CPU2 SLOT6 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: Available - Length: Short - ID: 6 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x000E, DMI type 9, 17 bytes - System Slot Information - Designation: CPU2 SLOT8 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: Available - Length: Short - ID: 8 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x000F, DMI type 9, 17 bytes - System Slot Information - Designation: CPU1 SLOT9 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: Available - Length: Short - ID: 9 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x0010, DMI type 9, 17 bytes - System Slot Information - Designation: CPU2 SLOT10 PCI-E 3.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: Available - Length: Short - ID: 10 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x0011, DMI type 9, 17 bytes - System Slot Information - Designation: CPU2 SLOT11 PCI-E 3.0 X4(IN X8) - Type: x4 PCI Express 3 x8 - Current Usage: Available - Length: Short - ID: 11 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x0012, DMI type 9, 17 bytes - System Slot Information - Designation: M.2 CONNECTOR - Type: x4 M.2 Socket 2 - Current Usage: Available - Length: Short - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 -``` - -## Linux dmidecode memory - -``` - Handle 0x0023, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0021 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMA1 - Bank Locator: P0_Node0_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F0E - Asset Tag: P1-DIMMA1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0024, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0021 - Error Information Handle: Not Provided - Total Width: Unknown - Data Width: Unknown - Size: No Module Installed - Form Factor: DIMM - Set: None - Locator: P1-DIMMA2 - Bank Locator: P0_Node0_Channel0_Dimm1 - Type: Unknown - Type Detail: Unknown - Speed: Unknown - Manufacturer: NO DIMM - Serial Number: NO DIMM - Asset Tag: NO DIMM - Part Number: NO DIMM - Rank: Unknown - Configured Clock Speed: Unknown - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0025, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0021 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMB1 - Bank Locator: P0_Node0_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F1F - Asset Tag: P1-DIMMB1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0027, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0021 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMC1 - Bank Locator: P0_Node0_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F07 - Asset Tag: P1-DIMMC1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x002B, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0029 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMD1 - Bank Locator: P0_Node1_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F02 - Asset Tag: P1-DIMMD1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x002C, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0029 - Error Information Handle: Not Provided - Total Width: Unknown - Data Width: Unknown - Size: No Module Installed - Form Factor: DIMM - Set: None - Locator: P1-DIMMD2 - Bank Locator: P0_Node1_Channel0_Dimm1 - Type: Unknown - Type Detail: Unknown - Speed: Unknown - Manufacturer: NO DIMM - Serial Number: NO DIMM - Asset Tag: NO DIMM - Part Number: NO DIMM - Rank: Unknown - Configured Clock Speed: Unknown - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x002D, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0029 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMME1 - Bank Locator: P0_Node1_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F19 - Asset Tag: P1-DIMME1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x002F, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0029 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMF1 - Bank Locator: P0_Node1_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275FD3 - Asset Tag: P1-DIMMF1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0031, DMI type 16, 23 bytes - Physical Memory Array - Location: System Board Or Motherboard - Use: System Memory - Error Correction Type: Single-bit ECC - Maximum Capacity: 2304 GB - Error Information Handle: Not Provided - Number Of Devices: 4 - - Handle 0x0033, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0031 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMA1 - Bank Locator: P1_Node0_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275FE2 - Asset Tag: P2-DIMMA1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0034, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0031 - Error Information Handle: Not Provided - Total Width: Unknown - Data Width: Unknown - Size: No Module Installed - Form Factor: DIMM - Set: None - Locator: P2-DIMMA2 - Bank Locator: P1_Node0_Channel0_Dimm1 - Type: Unknown - Type Detail: Unknown - Speed: Unknown - Manufacturer: NO DIMM - Serial Number: NO DIMM - Asset Tag: NO DIMM - Part Number: NO DIMM - Rank: Unknown - Configured Clock Speed: Unknown - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0035, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0031 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMB1 - Bank Locator: P1_Node0_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93276001 - Asset Tag: P2-DIMMB1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0037, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0031 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMC1 - Bank Locator: P1_Node0_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93276005 - Asset Tag: P2-DIMMC1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0039, DMI type 16, 23 bytes - Physical Memory Array - Location: System Board Or Motherboard - Use: System Memory - Error Correction Type: Single-bit ECC - Maximum Capacity: 2304 GB - Error Information Handle: Not Provided - Number Of Devices: 4 - - Handle 0x003B, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0039 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMD1 - Bank Locator: P1_Node1_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275F44 - Asset Tag: P2-DIMMD1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x003C, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0039 - Error Information Handle: Not Provided - Total Width: Unknown - Data Width: Unknown - Size: No Module Installed - Form Factor: DIMM - Set: None - Locator: P2-DIMMD2 - Bank Locator: P1_Node1_Channel0_Dimm1 - Type: Unknown - Type Detail: Unknown - Speed: Unknown - Manufacturer: NO DIMM - Serial Number: NO DIMM - Asset Tag: NO DIMM - Part Number: NO DIMM - Rank: Unknown - Configured Clock Speed: Unknown - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x003D, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0039 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMME1 - Bank Locator: P1_Node1_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275FDF - Asset Tag: P2-DIMME1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x003F, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0039 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMF1 - Bank Locator: P1_Node1_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous - Speed: 2933 MT/s - Manufacturer: SK Hynix - Serial Number: 93275FDD - Asset Tag: P2-DIMMF1_AssetTag (date:19/22) - Part Number: HMA82GR7CJR8N-WM - Rank: 2 - Configured Clock Speed: 2934 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V -``` - -## Xeon CLX Server BIOS Configuration - TG - -### Boot Feature - -``` - | Quiet Boot [Enabled] |Boot option | - | | | - | Option ROM Messages [Force BIOS] | | - | Bootup NumLock State [On] | | - | Wait For "F1" If Error [Enabled] | | - | INT19 Trap Response [Immediate] | | - | Re-try Boot [Disabled] | | - | Install Windows 7 USB support [Disabled] | | - | Port 61h Bit-4 Emulation [Disabled] | | - | | | - | Power Configuration | | - | Watch Dog Function [Disabled] | | - | Restore on AC Power Loss [Last State] | | - | Power Button Function [Instant Off] | | -``` - -### CPU Configuration - -``` - | Processor Configuration ^|Enables Hyper Threading | - | -------------------------------------------------- *|(Software Method to | - | Processor BSP Revision 50657 - CLX B1 *|Enable/Disable Logical | - | Processor Socket CPU1 | CPU2 *|Processor threads. | - | Processor ID 00050657* | 00050657 *| | - | Processor Frequency 2.700GHz | 2.700GHz *| | - | Processor Max Ratio 1BH | 1BH *| | - | Processor Min Ratio 0AH | 0AH *| | - | Microcode Revision 0500002C | 0500002C *| | - | L1 Cache RAM 64KB | 64KB *| | - | L2 Cache RAM 1024KB | 1024KB *| | - | L3 Cache RAM 39424KB | 39424KB *| | - | Processor 0 Version *| | - | Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz *| | - | Processor 1 Version *| | - | Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz *| | - | *|-----------------------------| - | Hyper-Threading [ALL] [Enable] *|><: Select Screen | - | Cores Enabled 0 *|^v: Select Item | - | Monitor/Mwait [Auto] *|Enter: Select | - | Execute Disable Bit [Enable] +|+/-: Change Opt. | - | Intel Virtualization Technology [Enable] +|F1: General Help | - | PPIN Control [Unlock/Enable] +|F2: Previous Values | - | Hardware Prefetcher [Enable] +|F3: Optimized Defaults | - | Adjacent Cache Prefetch [Enable] v|F4: Save & Exit | - | DCU Streamer Prefetcher [Enable] | | - | DCU IP Prefetcher [Enable] | | - | LLC Prefetch [Disable] | | - | Extended APIC [Disable] | | - | AES-NI [Enable] | | - |> Advanced Power Management Configuration | | -``` - -#### Advanced Power Management Configuration - -``` - | Advanced Power Management Configuration |Switch CPU Power Management | - | -------------------------------------------------- |profile | - | Power Technology [Custom] | | - | Power Performance Tuning [BIOS Controls EPB] | | - | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | | - |> CPU P State Control | | - |> Hardware PM State Control | | - |> CPU C State Control | | - |> Package C State Control | | - |> CPU T State Control | | -``` - -##### CPU P State Control - -``` - | CPU P State Control |EIST allows the processor | - | |to dynamically adjust | - | SpeedStep (P-States) [Disable] |frequency and voltage based | - | EIST PSD Function [HW_ALL] |on power versus performance | - | |needs. | - | | | -``` - -##### Hardware PM State Control - -``` - | Hardware PM State Control |If set to Disable, hardware ^| - | |will choose a P-state *| - | Hardware P-States [Disable] |setting for the system *| - | |based on an OS request. *| - | |If set to Native Mode, *| - | |hardware will choose a *| - | |P-state setting based on OS *| - | |guidance. *| - | |If set to Native Mode with *| - | |No Legacy Support, hardware *| - | |will choose a P-state *| - | |setting independently *| - | |without OS guidance. +| - | |If set to Out of Band Mode, +| - | |hardware autonomously v| -``` - -##### CPU C State Control - -``` - | CPU C State Control |Select Enable to support | - | |Autonomous Core C-State | - | Autonomous Core C-State [Disable] |control which will allow | - | CPU C6 report [Disable] |the processor core to | - | Enhanced Halt State (C1E) [Disable] |control its C-State setting | - | |automatically and | - | |independently. | -``` - -##### Package C State Control - -``` - | Package C State Control |Limit the lowest package | - | |level C-State to | - | Package C State [C0/C1 state] |processors. Lower package | - | |C-State lower processor | - | |power consumption upon idle. | -``` - -##### CPU T State Control - -``` - | CPU T State Control |Enable/Disable CPU | - | |throttling by OS. | - | Software Controlled T-States [Disable] |Throttling reduces power | - | |consumption | -``` - -#### Chipset Configuration - -``` - | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters | - | system to malfunction. | | - |> North Bridge | | - |> South Bridge | | -``` - -##### North Bridge - -``` - |> UPI Configuration |Displays and provides | - |> Memory Configuration |option to change the UPI | - |> IIO Configuration |Settings | -``` - -##### UPI Configuration - -``` - | UPI Configuration |Use this feature to select | - | -------------------------------------------------- |the degrading precedence | - | Number of CPU 2 |option for Ultra Path | - | Number of Active UPI Link 3 |Interconnect connections. | - | Current UPI Link Speed Fast |Select Topology Precedent | - | Current UPI Link Frequency 10.4 GT/s |to degrade UPI features if | - | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |system options are in | - | UPI Global MMIO High Base / Limit 0000000000000000 / |conflict. Select Feature | - | 00000000FFFFFFFF |Precedent to degrade UPI | - | UPI Pci-e Configuration Base / Size 80000000 / 10000000 |topology if system options | - | Degrade Precedence [Topology Precedence] |are in conflict. | - | Link L0p Enable [Disable] | | - | Link L1 Enable [Disable] | | - | IO Directory Cache (IODC) [Auto] | | - | SNC [Disable] | | - | XPT Prefetch [Disable] | | - | KTI Prefetch [Enable] |-----------------------------| - | Local/Remote Threshold [Auto] |><: Select Screen | - | Stale AtoS [Auto] |^v: Select Item | - | LLC Dead Line Alloc [Enable] |Enter: Select | - | Isoc Mode [Auto] |+/-: Change Opt. | -``` - -##### Memory Configuration - -``` - | |Select POR to enforce POR | - | -------------------------------------------------- |restrictions for DDR4 | - | Integrated Memory Controller (iMC) |frequency and voltage | - | -------------------------------------------------- |programming | - | | | - | Enforce POR [POR] | | - | PPR Type [Hard PPR] | | - | Enhanced PPR [Disable] | | - | Operation Mode [Test and Repair] | | - | Memory Frequency [2933] | | - | Data Scrambling for DDR4 [Auto] | | - | tCCD_L Relaxation [Auto] | | - | tRWSR Relaxation [Disable] | | - | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | | - | 2x Refresh [Auto] | | - | Page Policy [Auto] | | - | IMC Interleaving [2-way Interleave] |-----------------------------| - |> Memory Topology |><: Select Screen | - |> Memory RAS Configuration |^v: Select Item | -``` - -##### IIO Configuration - -``` - | IIO Configuration |Expose IIO DFX devices and | - | -------------------------------------------------- |other CPU devices like PMON | - | | | - | EV DFX Features [Disable] | | - |> CPU1 Configuration | | - |> CPU2 Configuration | | - |> IOAT Configuration | | - |> Intel. VT for Directed I/O (VT-d) | | - |> Intel. VMD technology | | - | | | - | IIO-PCIE Express Global Options | | - | ======================================== | | - | PCI-E Completion Timeout Disable [No] | | -``` - -##### CPU1 Configuration - -``` - | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | - | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | - |> CPU1 SLOT2 PCI-E 3.0 X16 | | - |> CPU1 SLOT4 PCI-E 3.0 X16 | | - |> CPU1 SLOT9 PCI-E 3.0 X16 | | -``` - -##### CPU2 Configuration - -``` - | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | - | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | - |> CPU2 SLOT6 PCI-E 3.0 X16 | | - |> CPU2 SLOT8 PCI-E 3.0 X16 | | - |> CPU2 SLOT10 PCI-E 3.0 X16 | | -``` - -#### South Bridge - -``` - | |Enables Legacy USB support. | - | USB Module Version 21 |AUTO option disables legacy | - | |support if no USB devices | - | USB Devices: |are connected. DISABLE | - | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB | - | |devices available only for | - | Legacy USB Support [Enabled] |EFI applications. | - | XHCI Hand-off [Enabled] | | - | Port 60/64 Emulation [Enabled] | | - | PCIe PLL SSC [Disable] | | - | Real USB Wake Up [Enabled] | | - | Front USB Wake Up [Enabled] | | - | | | - | Azalia [Auto] | | - | Azalia PME Enable [Disabled] | | -``` - -### PCIe/PCI/PnP Configuration - -``` - | PCI Bus Driver Version A5.01.18 ^|Enables or Disables 64bit | - | *|capable Devices to be | - | PCI Devices Common Settings: *|Decoded in Above 4G Address | - | Above 4G Decoding [Enabled] *|Space (Only if System | - | SR-IOV Support [Enabled] *|Supports 64 bit PCI | - | ARI Support [Enabled] *|Decoding). | - | MMIO High Base [56T] *| | - | MMIO High Granularity Size [256G] *| | - | Maximum Read Request [Auto] *| | - | MMCFG Base [2G] *| | - | NVMe Firmware Source [Vendor Defined *| | - | Firmware] *| | - | VGA Priority [Onboard] *| | - | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] *|-----------------------------| - | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] *|><: Select Screen | - | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] *|^v: Select Item | - | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] *|Enter: Select | - | M.2 CONNECTOR OPROM [Legacy] *|+/-: Change Opt. | - | Bus Master Enable [Enabled] +|F1: General Help | - | Onboard LAN1 Option ROM [Legacy] +|F2: Previous Values | - | Onboard LAN2 Option ROM [Disabled] +|F3: Optimized Defaults | - | Onboard Video Option ROM [Legacy] v|F4: Save & Exit | - |> Network Stack Configuration | | -``` - -### ACPI Settings - -``` - | ACPI Settings |Enable or Disable Non | - | |uniform Memory Access | - | NUMA [Enabled] |(NUMA). | - | WHEA Support [Enabled] | | - | High Precision Event Timer [Enabled] | | -``` - -## Xeon CLX Server BIOS Configuration - DUT - -### Boot Feature - -``` - | Quiet Boot [Enabled] |Boot option | - | | | - | Option ROM Messages [Force BIOS] | | - | Bootup NumLock State [On] | | - | Wait For "F1" If Error [Enabled] | | - | INT19 Trap Response [Immediate] | | - | Re-try Boot [Disabled] | | - | Install Windows 7 USB support [Disabled] | | - | Port 61h Bit-4 Emulation [Disabled] | | - | | | - | Power Configuration | | - | Watch Dog Function [Disabled] | | - | Restore on AC Power Loss [Last State] | | - | Power Button Function [Instant Off] | | -``` - -### CPU Configuration - -``` - |--------------------------------------------------------------------+-----------------------------\ - | Processor Configuration ^|Enables Hyper Threading | - | -------------------------------------------------- *|(Software Method to | - | Processor BSP Revision 50657 - CLX B1 *|Enable/Disable Logical | - | Processor Socket CPU1 | CPU2 *|Processor threads. | - | Processor ID 00050657* | 00050657 *| | - | Processor Frequency 2.300GHz | 2.300GHz *| | - | Processor Max Ratio 17H | 17H *| | - | Processor Min Ratio 0AH | 0AH *| | - | Microcode Revision 0500002C | 0500002C *| | - | L1 Cache RAM 64KB | 64KB *| | - | L2 Cache RAM 1024KB | 1024KB *| | - | L3 Cache RAM 36608KB | 36608KB *| | - | Processor 0 Version *| | - | Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz *| | - | Processor 1 Version *| | - | Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz *| | - | *|-----------------------------| - | Hyper-Threading [ALL] [Enable] *|><: Select Screen | - | Cores Enabled 0 *|^v: Select Item | - | Monitor/Mwait [Auto] *|Enter: Select | - | Execute Disable Bit [Enable] +|+/-: Change Opt. | - | Intel Virtualization Technology [Enable] +|F1: General Help | - | PPIN Control [Unlock/Enable] +|F2: Previous Values | - | Hardware Prefetcher [Enable] +|F3: Optimized Defaults | - | Adjacent Cache Prefetch [Enable] v|F4: Save & Exit | - | DCU Streamer Prefetcher [Enable] | | - | DCU IP Prefetcher [Enable] | | - | LLC Prefetch [Disable] | | - | Extended APIC [Disable] | | - | AES-NI [Enable] | | - |> Advanced Power Management Configuration | | -``` - -#### Advanced Power Management Configuration - -``` - | Advanced Power Management Configuration |Switch CPU Power Management | - | -------------------------------------------------- |profile | - | Power Technology [Custom] | | - | Power Performance Tuning [BIOS Controls EPB] | | - | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | | - |> CPU P State Control | | - |> Hardware PM State Control | | - |> CPU C State Control | | - |> Package C State Control | | - |> CPU T State Control | | -``` - -##### CPU P State Control - -``` - | CPU P State Control |EIST allows the processor | - | |to dynamically adjust | - | SpeedStep (P-States) [Disable] |frequency and voltage based | - | Activate PBF [Disable] |on power versus performance | - | Configure PBF [Enable] |needs. | - | EIST PSD Function [HW_ALL] | | -``` - -##### Hardware PM State Control - -``` - | Hardware PM State Control |If set to Disable, hardware ^| - | |will choose a P-state *| - | Hardware P-States [Disable] |setting for the system *| - | |based on an OS request. *| - | |If set to Native Mode, *| - | |hardware will choose a *| - | |P-state setting based on OS *| - | |guidance. *| - | |If set to Native Mode with *| - | |No Legacy Support, hardware *| - | |will choose a P-state *| - | |setting independently *| - | |without OS guidance. +| - | |If set to Out of Band Mode, +| - | |hardware autonomously v| -``` - -##### CPU C State Control - -``` - | CPU C State Control |Select Enable to support | - | |Autonomous Core C-State | - | Autonomous Core C-State [Disable] |control which will allow | - | CPU C6 report [Disable] |the processor core to | - | Enhanced Halt State (C1E) [Disable] |control its C-State setting | - | |automatically and | - | |independently. | -``` - -##### Package C State Control - -``` - | Package C State Control |Limit the lowest package | - | |level C-State to | - | Package C State [C0/C1 state] |processors. Lower package | - | |C-State lower processor | - | |power consumption upon idle. | -``` - -##### CPU T State Control - -``` - | CPU T State Control |Enable/Disable CPU | - | |throttling by OS. | - | Software Controlled T-States [Disable] |Throttling reduces power | - | |consumption | -``` - -#### Chipset Configuration - -``` - | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters | - | system to malfunction. | | - |> North Bridge | | - |> South Bridge | | -``` - -##### North Bridge - -``` - |> UPI Configuration |Displays and provides | - |> Memory Configuration |option to change the UPI | - |> IIO Configuration |Settings | -``` - -##### UPI Configuration - -``` - | UPI Configuration |Use this feature to select | - | -------------------------------------------------- |the degrading precedence | - | Number of CPU 2 |option for Ultra Path | - | Number of Active UPI Link 3 |Interconnect connections. | - | Current UPI Link Speed Fast |Select Topology Precedent | - | Current UPI Link Frequency 10.4 GT/s |to degrade UPI features if | - | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |system options are in | - | UPI Global MMIO High Base / Limit 0000000000000000 / |conflict. Select Feature | - | 00000000FFFFFFFF |Precedent to degrade UPI | - | UPI Pci-e Configuration Base / Size 80000000 / 10000000 |topology if system options | - | Degrade Precedence [Topology Precedence] |are in conflict. | - | Link L0p Enable [Disable] | | - | Link L1 Enable [Disable] | | - | IO Directory Cache (IODC) [Auto] | | - | SNC [Disable] | | - | XPT Prefetch [Disable] | | - | KTI Prefetch [Enable] |-----------------------------| - | Local/Remote Threshold [Auto] |><: Select Screen | - | Stale AtoS [Auto] |^v: Select Item | - | LLC Dead Line Alloc [Enable] |Enter: Select | - | Isoc Mode [Auto] |+/-: Change Opt. | -``` - -##### Memory Configuration - -``` - | |Select POR to enforce POR | - | -------------------------------------------------- |restrictions for DDR4 | - | Integrated Memory Controller (iMC) |frequency and voltage | - | -------------------------------------------------- |programming | - | | | - | Enforce POR [POR] | | - | PPR Type [Hard PPR] | | - | Enhanced PPR [Disable] | | - | Operation Mode [Test and Repair] | | - | Memory Frequency [2933] | | - | Data Scrambling for DDR4 [Auto] | | - | tCCD_L Relaxation [Auto] | | - | tRWSR Relaxation [Disable] | | - | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | | - | 2x Refresh [Auto] | | - | Page Policy [Auto] | | - | IMC Interleaving [2-way Interleave] |-----------------------------| - |> Memory Topology |><: Select Screen | - |> Memory RAS Configuration |^v: Select Item | -``` - -##### IIO Configuration - -``` - | IIO Configuration |Expose IIO DFX devices and | - | -------------------------------------------------- |other CPU devices like PMON | - | | | - | EV DFX Features [Disable] | | - |> CPU1 Configuration | | - |> CPU2 Configuration | | - |> IOAT Configuration | | - |> Intel. VT for Directed I/O (VT-d) | | - |> Intel. VMD technology | | - | | | - | IIO-PCIE Express Global Options | | - | ======================================== | | - | PCI-E Completion Timeout Disable [No] | | -``` - -##### CPU1 Configuration - -``` - | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | - | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | - |> CPU1 SLOT2 PCI-E 3.0 X16 | | - |> CPU1 SLOT4 PCI-E 3.0 X16 | | - |> CPU1 SLOT9 PCI-E 3.0 X16 | | -``` - -##### CPU2 Configuration - -``` - | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | - | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | - |> CPU2 SLOT6 PCI-E 3.0 X16 | | - |> CPU2 SLOT8 PCI-E 3.0 X16 | | - |> CPU2 SLOT10 PCI-E 3.0 X16 | | -``` - -#### South Bridge - -``` - | |Enables Legacy USB support. | - | USB Module Version 21 |AUTO option disables legacy | - | |support if no USB devices | - | USB Devices: |are connected. DISABLE | - | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB | - | |devices available only for | - | Legacy USB Support [Enabled] |EFI applications. | - | XHCI Hand-off [Enabled] | | - | Port 60/64 Emulation [Enabled] | | - | PCIe PLL SSC [Disable] | | - | Real USB Wake Up [Enabled] | | - | Front USB Wake Up [Enabled] | | - | | | - | Azalia [Auto] | | - | Azalia PME Enable [Disabled] | | -``` - -### PCIe/PCI/PnP Configuration - -``` - | PCI Bus Driver Version A5.01.18 ^|Enables or Disables 64bit | - | *|capable Devices to be | - | PCI Devices Common Settings: *|Decoded in Above 4G Address | - | Above 4G Decoding [Enabled] *|Space (Only if System | - | SR-IOV Support [Enabled] *|Supports 64 bit PCI | - | ARI Support [Enabled] *|Decoding). | - | MMIO High Base [56T] *| | - | MMIO High Granularity Size [256G] *| | - | Maximum Read Request [Auto] *| | - | MMCFG Base [2G] *| | - | NVMe Firmware Source [Vendor Defined *| | - | Firmware] *| | - | VGA Priority [Onboard] *| | - | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] *| | - | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] *|-----------------------------| - | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] *|><: Select Screen | - | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] *|^v: Select Item | - | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] *|Enter: Select | - | M.2 CONNECTOR OPROM [Legacy] *|+/-: Change Opt. | - | Bus Master Enable [Enabled] +|F1: General Help | - | Onboard LAN1 Option ROM [Legacy] +|F2: Previous Values | - | Onboard LAN2 Option ROM [Disabled] +|F3: Optimized Defaults | - | Onboard Video Option ROM [Legacy] v|F4: Save & Exit | - |> Network Stack Configuration | | -``` - -### ACPI Settings - -``` - | ACPI Settings |Enable or Disable Non | - | |uniform Memory Access | - | NUMA [Enabled] |(NUMA). | - | WHEA Support [Enabled] | | - | High Precision Event Timer [Enabled] | | -``` - - -## Xeon Clx Server Firmware Inventory - -``` -Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. PCI Bus. X710 Firmware. XXV710 Firmware. i40e. MLX5 Firmware. mlx5_core E810 Firmware. ice. -s33-t27-sut1. 10.30.55.18. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.70. 8.70. 2.19.3. 16.32.1010. 5.6-1.0.3.3. 4.00. 1.9.7. -s34-t27-tg1. 10.30.55.19. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.30. 8.30. 2.19.3. 16.32.1010. 5.6-1.0.3.3. N/A. N/A. -s35-t28-sut1. 10.30.55.20. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.70. 8.70. 2.19.3. 16.32.1010. 5.6-1.0.3.3. 4.00. 1.9.7. -s36-t28-tg1. 10.30.55.21. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.30. 8.30. 2.19.3. 16.32.1010. 5.6-1.0.3.3. N/A. N/A. -s37-t29-sut1. 10.30.55.22. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.70. 8.70. 2.19.3. 16.32.1010. 5.6-1.0.3.3. 4.00. 1.9.7. -s38-t29-tg1. 10.30.55.23. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 8.30. 8.30. 2.19.3. 16.32.1010. 5.6-1.0.3.3. N/A. N/A. -``` diff --git a/docs/lab/testbeds_sm_icx_hw_bios_cfg.md b/docs/lab/testbeds_sm_icx_hw_bios_cfg.md deleted file mode 100644 index d0bea7f40f..0000000000 --- a/docs/lab/testbeds_sm_icx_hw_bios_cfg.md +++ /dev/null @@ -1,1132 +0,0 @@ -# SuperMicro Icelake Servers - HW and BIOS Configuration - -1. [Linux lscpu](#linux-lscpu) -1. [Linux dmidecode](#dmidecode) -1. [Linux dmidecode memory](#linux-dmidecode-memory) -1. [Xeon ICX Server BIOS Configuration](#xeon-icx-server-bios-configuration) - 1. [Boot Feature](#boot-feature) - 1. [CPU Configuration](#cpu-configuration) - 1. [Advanced Power Management Configuration](#advanced-power-management-configuration) - 1. [CPU P State Control](#cpu-p-state-control) - 1. [Hardware PM State Control](#hardware-pm-state-control) - 1. [CPU C State Control](#cpu-c-state-control) - 1. [Package C State Control](#package-c-state-control) - 1. [CPU T State Control](#cpu-t-state-control) - 1. [Chipset Configuration](#chipset-configuration) - 1. [North Bridge](#north-bridge) - 1. [UPI Configuration](#upi-configuration) - 1. [Memory Configuration](#memory-configuration) - 1. [IIO Configuration](#iio-configuration) - 1. [CPU1 Configuration](#cpu1-configuration) - 1. [CPU2 Configuration](#cpu2-configuration) - 1. [South Bridge](#south-bridge) - 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration) - 1. [ACPI Settings](#acpi-settings) -1. [Xeon ICX Server Firmware Inventory](#xeon-icx-server-firmware-inventory) - -## Linux lscpu - -``` -$ lscpu -Architecture: x86_64 -CPU op-mode(s): 32-bit, 64-bit -Byte Order: Little Endian -Address sizes: 46 bits physical, 57 bits virtual -CPU(s): 128 -On-line CPU(s) list: 0-127 -Thread(s) per core: 2 -Core(s) per socket: 32 -Socket(s): 2 -NUMA node(s): 2 -Vendor ID: GenuineIntel -CPU family: 6 -Model: 106 -Model name: Intel(R) Xeon(R) Platinum 8358 CPU @ 2.60GHz -Stepping: 6 -CPU MHz: 3283.980 -BogoMIPS: 5200.00 -Virtualization: VT-x -L1d cache: 3 MiB -L1i cache: 2 MiB -L2 cache: 80 MiB -L3 cache: 96 MiB -NUMA node0 CPU(s): 0-31,64-95 -NUMA node1 CPU(s): 32-63,96-127 -Vulnerability Itlb multihit: Not affected -Vulnerability L1tf: Not affected -Vulnerability Mds: Not affected -Vulnerability Meltdown: Not affected -Vulnerability Spec store bypass: Mitigation; Speculative Store Bypass disabled via prctl and seccomp -Vulnerability Spectre v1: Mitigation; usercopy/swapgs barriers and __user pointer sanitization -Vulnerability Spectre v2: Mitigation; Enhanced IBRS, IBPB conditional, RSB filling -Vulnerability Srbds: Not affected -Vulnerability Tsx async abort: Not affected -Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe sysca - ll nx pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc cpuid aperfmperf pni pclmu - lqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadl - ine_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch cpuid_fault epb cat_l3 invpcid_single ssbd mba ibrs ibpb stibp - ibrs_enhanced tpr_shadow vnmi flexpriority ept vpid ept_ad fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm rdt_a avx - 512f avx512dq rdseed adx smap avx512ifma clflushopt clwb intel_pt avx512cd sha_ni avx512bw avx512vl xsaveopt xsavec xgetbv1 x - saves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local wbnoinvd dtherm ida arat pln pts avx512vbmi umip pku ospke avx512_vbm - i2 gfni vaes vpclmulqdq avx512_vnni avx512_bitalg tme avx512_vpopcntdq rdpid md_clear pconfig flush_l1d arch_capabilities -``` - -## Linux dmidecode - -``` -# dmidecode 3.2 -Getting SMBIOS data from sysfs. -SMBIOS 3.3.0 present. -# SMBIOS implementations newer than version 3.2.0 are not -# fully supported by this version of dmidecode. -Table at 0x6BAEE000. - -Handle 0x0000, DMI type 0, 26 bytes -BIOS Information - Vendor: American Megatrends International, LLC. - Version: 1.1 - Release Date: 04/09/2021 - Address: 0xF0000 - Runtime Size: 64 kB - ROM Size: 32 MB - Characteristics: - PCI is supported - BIOS is upgradeable - BIOS shadowing is allowed - Boot from CD is supported - Selectable boot is supported - BIOS ROM is socketed - EDD is supported - Japanese floppy for NEC 9800 1.2 MB is supported (int 13h) - Japanese floppy for Toshiba 1.2 MB is supported (int 13h) - 5.25"/360 kB floppy services are supported (int 13h) - 5.25"/1.2 MB floppy services are supported (int 13h) - 3.5"/720 kB floppy services are supported (int 13h) - 3.5"/2.88 MB floppy services are supported (int 13h) - Print screen service is supported (int 5h) - Serial services are supported (int 14h) - Printer services are supported (int 17h) - CGA/mono video services are supported (int 10h) - USB legacy is supported - BIOS boot specification is supported - Targeted content distribution is supported - UEFI is supported - BIOS Revision: 5.22 - -Handle 0x0001, DMI type 1, 27 bytes -System Information - Manufacturer: Supermicro - Product Name: SYS-740GP-TNRT - Version: 0123456789 - Serial Number: S424016X1B00510 - UUID: 0698ae00-2383-11ec-8000-3cecefb9a6ba - Wake-up Type: Power Switch - SKU Number: To be filled by O.E.M. - Family: Family - -Handle 0x0002, DMI type 2, 15 bytes -Base Board Information - Manufacturer: Supermicro - Product Name: X12DPG-QT6 - Version: 1.00 - Serial Number: UM219S003392 - Asset Tag: Base Board Asset Tag - Features: - Board is a hosting board - Board is replaceable - Location In Chassis: Part Component - Chassis Handle: 0x0003 - Type: Motherboard - Contained Object Handles: 0 - -Handle 0x0003, DMI type 3, 22 bytes -Chassis Information - Manufacturer: Supermicro - Type: Other - Lock: Not Present - Version: 0123456789 - Serial Number: C7470KK25P50098 - Asset Tag: Chassis Asset Tag - Boot-up State: Safe - Power Supply State: Safe - Thermal State: Safe - Security Status: None - OEM Information: 0x00000000 - Height: Unspecified - Number Of Power Cords: 1 - Contained Elements: 0 - SKU Number: To be filled by O.E.M. - -Handle 0x001B, DMI type 38, 18 bytes -IPMI Device Information - Interface Type: KCS (Keyboard Control Style) - Specification Version: 2.0 - I2C Slave Address: 0x10 - NV Storage Device: Not Present - Base Address: 0x0000000000000CA2 (I/O) - Register Spacing: Successive Byte Boundaries - -Handle 0x002A, DMI type 4, 48 bytes -Processor Information - Socket Designation: CPU1 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: A6 06 06 00 FF FB EB BF - Signature: Type 0, Family 6, Model 106, Stepping 6 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Platinum 8358 CPU @ 2.60GHz - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4500 MHz - Current Speed: 2600 MHz - Status: Populated, Enabled - Upgrade: - L1 Cache Handle: 0x0027 - L2 Cache Handle: 0x0028 - L3 Cache Handle: 0x0029 - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 32 - Core Enabled: 32 - Thread Count: 64 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control - -Handle 0x002E, DMI type 4, 48 bytes -Processor Information - Socket Designation: CPU2 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: A6 06 06 00 FF FB EB BF - Signature: Type 0, Family 6, Model 106, Stepping 6 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Platinum 8358 CPU @ 2.60GHz - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4500 MHz - Current Speed: 2600 MHz - Status: Populated, Enabled - Upgrade: - L1 Cache Handle: 0x002B - L2 Cache Handle: 0x002C - L3 Cache Handle: 0x002D - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 32 - Core Enabled: 32 - Thread Count: 64 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control -``` - -## Linux dmidecode memory - -``` -Handle 0x0034, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMA1 - Bank Locator: P0_Node0_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705C2E3 - Asset Tag: P1-DIMMA1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0036, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMB1 - Bank Locator: P0_Node0_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CE60 - Asset Tag: P1-DIMMB1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0038, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMC1 - Bank Locator: P0_Node0_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705C59E - Asset Tag: P1-DIMMC1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x003A, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMD1 - Bank Locator: P0_Node0_Channel3_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705D12D - Asset Tag: P1-DIMMD1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x003C, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMME1 - Bank Locator: P0_Node1_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705C69C - Asset Tag: P1-DIMME1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x003E, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMF1 - Bank Locator: P0_Node1_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705C33A - Asset Tag: P1-DIMMF1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0040, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMG1 - Bank Locator: P0_Node1_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705C59F - Asset Tag: P1-DIMMG1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0042, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P1-DIMMH1 - Bank Locator: P0_Node1_Channel3_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CA16 - Asset Tag: P1-DIMMH1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0044, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMA1 - Bank Locator: P1_Node0_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CBFE - Asset Tag: P2-DIMMA1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0046, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMB1 - Bank Locator: P1_Node0_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CFC8 - Asset Tag: P2-DIMMB1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0048, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMC1 - Bank Locator: P1_Node0_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CC02 - Asset Tag: P2-DIMMC1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x004A, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMD1 - Bank Locator: P1_Node0_Channel3_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CB5A - Asset Tag: P2-DIMMD1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x004C, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMME1 - Bank Locator: P1_Node1_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CB30 - Asset Tag: P2-DIMME1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x004E, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMF1 - Bank Locator: P1_Node1_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CB87 - Asset Tag: P2-DIMMF1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0050, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMG1 - Bank Locator: P1_Node1_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CB08 - Asset Tag: P2-DIMMG1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None - -Handle 0x0052, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x0033 - Error Information Handle: Not Provided - Total Width: 72 bits - Data Width: 64 bits - Size: 16384 MB - Form Factor: DIMM - Set: None - Locator: P2-DIMMH1 - Bank Locator: P1_Node1_Channel3_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: Samsung - Serial Number: H0MK0001304705CC01 - Asset Tag: P2-DIMMH1_AssetTag (date:21/30) - Part Number: M393A2K43DB3-CWE - Rank: 2 - Configured Memory Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xCE - Module Product ID: Unknown - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 16 GB - Cache Size: None - Logical Size: None -``` - -## Xeon ICX Server BIOS Configuration - -### Boot Feature - -``` - | |Enables or disables Quiet | - | Quiet Boot [Enabled] |Boot option | - | | | - | Option ROM Messages [Force BIOS] | | - | Bootup NumLock State [On] | | - | Wait For "F1" If Error [Disabled] | | - | INT19 Trap Response [Immediate] | | - | Re-try Boot [Disabled] | | - | | | - | Power Configuration | | - | | | - | Watch Dog Function [Disabled] | | - | Restore on AC Power Loss [Last State] | | - | Power Button Function [Instant Off] | | - | Deep Sleep Mode [Disabled] | | -``` - -### CPU Configuration - -``` - | Processor Configuration ^|Enables Hyper Threading | - | -------------------------------------------------- *|(Software Method to | - | Processor BSP Revision 606A6 - ICX D2 *|Enable/Disable Logical | - | Processor Socket CPU1 CPU2 *|Processor threads. | - | Processor ID 000606A6* | 000606A6 *| | - | Processor Frequency 2.600GHz | 2.600GHz *| | - | Processor Max Ratio 1AH | 1AH *| | - | Processor Min Ratio 08H | 08H *| | - | Microcode Revision 0D000280 | 0D000280 *| | - | L1 Cache RAM(Per Core) 80KB | 80KB *| | - | L2 Cache RAM(Per Core) 1280KB | 1280KB *| | - | L3 Cache RAM(Per Package) 49152KB | 49152KB *| | - | Processor 0 Version Intel(R) Xeon(R) *| | - | Platinum 8358 CPU @ *| | - | 2.60GHz *| | - | Processor 1 Version Intel(R) Xeon(R) *| | - | Platinum 8358 CPU @ *| | - | 2.60GHz *| | - | +| | - |> CPU1 Core Disable Bitmap +| | - |> CPU2 Core Disable Bitmap +|-----------------------------| - | Hyper-Threading [ALL] [Enable] +|><: Select Screen | - | Hardware Prefetcher [Enable] +|^v: Select Item | - | Adjacent Cache Prefetch [Enable] +|Enter: Select | - | DCU Streamer Prefetcher [Enable] +|+/-: Change Opt. | - | DCU IP Prefetcher [Enable] +|F1: General Help | - | LLC Prefetch [Enable] +|F2: Previous Values | - | Extended APIC [Disable] +|F3: Optimized Defaults | - | VMX [Enable] v|F4: Save & Exit | - | Enable SMX [Disable] +| | - | PPIN Control [Unlock/Enable] *| | - | AES-NI [Enable] *| | - | -------------------------------------------------- *| | - | TME, TME-MT, TDX *| | - | -------------------------------------------------- *| | - | Total Memory Encryption (TME) [Disabled] *| | - | -------------------------------------------------- *|-----------------------------| - | Software Guard Extension (SGX) *|><: Select Screen | - | -------------------------------------------------- *|^v: Select Item | - | SGX Factory Reset [Disabled] *|Enter: Select | - | SW Guard Extensions (SGX) [Disabled] *|+/-: Change Opt. | - | SGX Package Info In-Band Access [Disabled] *|F1: General Help | - | -------------------------------------------------- *|F2: Previous Values | - | Limit CPU PA to 46 Bits [Enable] *|F3: Optimized Defaults | - |> Advanced Power Management Configuration v|F4: Save & Exit | -``` - -#### Advanced Power Management Configuration - -``` - | Advanced Power Management Configuration |Enable processor power | - | -------------------------------------------------- |management features. | - | Power Technology [Custom] | | - | Power Performance Tuning [BIOS Controls EPB] | | - | ENERGY_PERF_BIAS_CFG Mode [Maximum Performance] | | -``` - -##### CPU P State Control - -``` - | CPU P State Control |EIST allows the processor | - | |to dynamically adjust | - | SpeedStep (P-States) [Disable] |frequency and voltage based | - | Activate SST-BF [Disable] |on power versus performance | - | Configure SST-BF [Enable] |needs. | - | EIST PSD Function [HW_ALL] | | -``` - -##### Hardware PM State Control - -``` - | Hardware PM State Control |If set to Disable, hardware ^| - | |will choose a P-state *| - | Hardware P-States [Disable] |setting for the system *| - | |based on an OS request. *| - - | Frequency Prioritization |This knob controls whether | - | |RAPL balancer is enabled. | - | RAPL Prioritization [Disable] |When enabled it activates | -``` - -##### CPU C State Control - -``` - | CPU C State Control |Allows Monitor and MWAIT | - | |instructions. | - | Enable Monitor MWAIT [Enable] | | - | CPU C6 Report [Disable] | | - | Enhanced Halt State (C1E) [Disable] | | -``` - -##### Package C State Control - -``` - | Package C State Control |Limit the lowest package | - | |level C-State to | - | Package C State [C0/C1 state] |processors. Lower package | -``` - -##### CPU T State Control - -``` - | CPU T State Control |Enable/Disable CPU | - | |throttling by OS. | - | Software Controlled T-States [Disable] |Throttling reduces power | -``` - -##### UPI Configuration - -``` - | Uncore Configuration |Choose Topology Precedence | - | -------------------------------------------------- |to degrade features if | - | Number of CPU 2 |system options are in | - | Number of IIO 2 |conflict or choose Feature | - | Current UPI Link Speed Fast |Precedence to degrade | - | Current UPI Link Frequency 11.2 GT/s |topology if system options | - | Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. | - | Global MMIO High Base / Limit 0000200000000000 / | | - | 0000204FFFFFFFFF | | - | Pci-e Configuration Base / Size 80000000 / 10000000 | | - | Degrade Precedence [Topology Precedence] | | - | Link L0p Enable [Disable] | | - | Link L1 Enable [Disable] | | - | XPT Remote Prefetch [Auto] | | - | KTI Prefetch [Auto] |-----------------------------| - | Local/Remote Threshold [Auto] |><: Select Screen | - | IO Directory Cache (IODC) [Auto] |^v: Select Item | - | SNC (Sub NUMA) [Disable] |Enter: Select | - | XPT Prefetch [Auto] |+/-: Change Opt. | - | Snoop Throttle Configuration [Auto] |F1: General Help | - | PCIe Remote P2P Relaxed Ordering [Disable] |F2: Previous Values | - | Stale AtoS [Auto] |F3: Optimized Defaults | - | LLC Dead Line Alloc [Enable] |F4: Save & Exit | -``` - -##### Memory Configuration - -``` - | |Set Enable or Disable | - | -------------------------------------------------- |STEP(Samsung TestBIOS & | - | Integrated Memory Controller (iMC) |Enhanced PPR)function | - | -------------------------------------------------- | | - | | | - | STEP DRAM Test [Disable] | | - | Operation Mode [Test and Repair] | | - | Enforce POR [POR] | | - | PPR Type [Hard PPR] | | - | Memory Frequency [Auto] | | - | Data Scrambling for DDR4 [Enable] | | - | 2x Refresh Enable [Auto] | | -``` - -##### IIO Configuration - -``` - | IIO Configuration |Press to bring up | - | -------------------------------------------------- |the Intel. Virtualization | - | |for Directed I/O (VT-d) | - |> CPU1 Configuration |Configuration menu. | - |> CPU2 Configuration | | - |> IOAT Configuration | | - |> Intel. VT for Directed I/O (VT-d) | | - |> Intel. VMD Technology | | - | PCI-E ASPM Support (Global) [Disable] | | - | IIO eDPC Support [Disable] | | -``` - -##### CPU1 Configuration - -``` - | IOU0 (IIO PCIe Port 1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Port 2) [Auto] |Bifurcation for selected | - | IOU3 (IIO PCIe Port 4) [Auto] |slot(s) | - | IOU4 (IIO PCIe Port 5) [Auto] | | -``` - -##### CPU2 Configuration - -``` - | IOU0 (IIO PCIe Port 1) [Auto] |Selects PCIe port | - | IOU1 (IIO PCIe Port 2) [Auto] |Bifurcation for selected | - | IOU3 (IIO PCIe Port 4) [Auto] |slot(s) | - | IOU4 (IIO PCIe Port 5) [Auto] | | -``` - -#### South Bridge - -``` - | USB Module Version 26 |AUTO option disables legacy | - | |support if no USB devices | - | USB Devices: |are connected. DISABLE | - | 1 Drive, 2 Keyboards, 2 Mice, 1 Hub |option will keep USB | - | |devices available only for | - | Legacy USB Support [Enabled] |EFI applications. | - | XHCI Hand-off [Enabled] | | - | Port 60/64 Emulation [Disabled] | | - | PCIe PLL SSC [Disabled] | | - | Port 61h Bit-4 Emulation [Disabled] | | -``` - -### PCIe/PCI/PnP Configuration - -``` - | PCI Bus Driver Version A5.01.24 ^|Enables or Disables 64bit | - | *|capable Devices to be | - | PCI Devices Common Settings: *|Decoded in Above 4G Address | - | Above 4G Decoding [Enabled] *|Space (Only if System | - | SR-IOV Support [Enabled] *|Supports 64 bit PCI | - | ARI Support [Enabled] *|Decoding). | - | Bus Master Enable [Enabled] *| | - | Consistent Device Name Support [Disabled] *| | - | MMIO High Base [32T] *| | - | MMIO High Granularity Size [64G] *| | - | Maximum Read Request [Auto] *| | - | MMCFG Base [Auto] *| | - | NVMe Firmware Source [Vendor Defined *| | - | Firmware] *| | - | VGA Priority [Onboard] *| | - | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [EFI] *| | - | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [EFI] *| | - | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [EFI] *| | - | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [EFI] *|-----------------------------| - | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [EFI] *|><: Select Screen | - | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [EFI] *|^v: Select Item | - | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [EFI] *|Enter: Select | - | M.2 CONNECTOR OPROM [EFI] *|+/-: Change Opt. | - | Bus Master Enable [Enabled] +|F1: General Help | - | Onboard LAN1 Option ROM [EFI] +|F2: Previous Values | - | Onboard LAN2 Option ROM [Disabled] +|F3: Optimized Defaults | - | Onboard Video Option ROM [EFI] v|F4: Save & Exit | - |> Network Stack Configuration | | -``` - -## Xeon ICX Server Firmware Inventory - -``` -Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. PCI Bus. X710 Firmware. i40e. E810 Firmware. ice. -s65-t37-sut1. 10.30.50.75. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s66-t37-sut2. 10.30.50.76. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s67-t37-tg1. 10.30.50.77. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -s78-t38-sut1. 10.30.50.78. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s79-t38-sut2. 10.30.50.79. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s80-t38-tg1. 10.30.50.80. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -s71-t212-sut1. 10.30.50.81. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s72-t212-tg1. 10.30.50.82. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -s83-t213-sut1. 10.30.50.83. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s84-t213-tg1. 10.30.50.84. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -s85-t214-sut1. 10.30.50.85. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s86-t214-tg1. 10.30.50.86. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -s87-t215-sut1. 10.30.50.87. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.70. 2.19.3. 4.00. 1.9.7. -s88-t215-tg1. 10.30.50.88. 1.00.21. 1.1. F1.00.07. 0D000280. A5.01.24. 8.30. 2.19.3. 3.20. 1.9.7. -``` diff --git a/docs/lab/testbeds_sm_spr_hw_bios_cfg.md b/docs/lab/testbeds_sm_spr_hw_bios_cfg.md deleted file mode 100644 index 9a72b84510..0000000000 --- a/docs/lab/testbeds_sm_spr_hw_bios_cfg.md +++ /dev/null @@ -1,845 +0,0 @@ -# SuperMicro SapphireRapids Servers - HW and BIOS Configuration - -1. [Linux lscpu](#linux-lscpu) -1. [Linux dmidecode](#dmidecode) -1. [Linux dmidecode memory](#linux-dmidecode-memory) -1. [Xeon SPR Server Firmware Inventory](#xeon-spr-server-firmware-inventory) - -## Linux lscpu - -``` -Architecture: x86_64 - CPU op-mode(s): 32-bit, 64-bit - Address sizes: 46 bits physical, 57 bits virtual - Byte Order: Little Endian -CPU(s): 128 - On-line CPU(s) list: 0-127 -Vendor ID: GenuineIntel - Model name: Intel(R) Xeon(R) Platinum 8462Y+ - CPU family: 6 - Model: 143 - Thread(s) per core: 2 - Core(s) per socket: 32 - Socket(s): 2 - Stepping: 8 - BogoMIPS: 5600.00 - Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1 - gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc cpuid aperfmperf tsc_known_freq pni pclmulqdq dt - es64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsav - e avx f16c rdrand lahf_lm abm 3dnowprefetch cpuid_fault epb cat_l3 cat_l2 cdp_l3 invpcid_single cdp_l2 ssbd mba ibrs ibpb stibp ibrs_enh - anced tpr_shadow vnmi flexpriority ept vpid ept_ad fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm rdt_a avx512f avx512dq rdsee - d adx smap avx512ifma clflushopt clwb intel_pt avx512cd sha_ni avx512bw avx512vl xsaveopt xsavec xgetbv1 xsaves cqm_llc cqm_occup_llc cq - m_mbm_total cqm_mbm_local split_lock_detect avx_vnni avx512_bf16 wbnoinvd dtherm arat pln pts hwp hwp_act_window hwp_epp hwp_pkg_req avx - 512vbmi umip pku ospke waitpkg avx512_vbmi2 gfni vaes vpclmulqdq avx512_vnni avx512_bitalg tme avx512_vpopcntdq la57 rdpid bus_lock_dete - ct cldemote movdiri movdir64b enqcmd fsrm md_clear serialize tsxldtrk pconfig arch_lbr amx_bf16 avx512_fp16 amx_tile amx_int8 flush_l1d - arch_capabilities -Virtualization features: - Virtualization: VT-x -Caches (sum of all): - L1d: 3 MiB (64 instances) - L1i: 2 MiB (64 instances) - L2: 128 MiB (64 instances) - L3: 120 MiB (2 instances) -NUMA: - NUMA node(s): 2 - NUMA node0 CPU(s): 0-31,64-95 - NUMA node1 CPU(s): 32-63,96-127 -Vulnerabilities: - Itlb multihit: Not affected - L1tf: Not affected - Mds: Not affected - Meltdown: Not affected - Mmio stale data: Not affected - Retbleed: Not affected - Spec store bypass: Mitigation; Speculative Store Bypass disabled via prctl and seccomp - Spectre v1: Mitigation; usercopy/swapgs barriers and __user pointer sanitization - Spectre v2: Mitigation; Enhanced IBRS, IBPB conditional, RSB filling - Srbds: Not affected - Tsx async abort: Not affected -``` - -## Linux dmidecode - -``` -# dmidecode 3.3 -Getting SMBIOS data from sysfs. -SMBIOS 3.5.0 present. -Table at 0x000E6E00. - -Handle 0x0000, DMI type 0, 26 bytes -BIOS Information - Vendor: American Megatrends International, LLC. - Version: 1.0 - Release Date: 11/16/2022 - Address: 0xF0000 - Runtime Size: 64 kB - ROM Size: 32 MB - Characteristics: - PCI is supported - BIOS is upgradeable - BIOS shadowing is allowed - Boot from CD is supported - Selectable boot is supported - BIOS ROM is socketed - EDD is supported - Japanese floppy for NEC 9800 1.2 MB is supported (int 13h) - Japanese floppy for Toshiba 1.2 MB is supported (int 13h) - 5.25"/360 kB floppy services are supported (int 13h) - 5.25"/1.2 MB floppy services are supported (int 13h) - 3.5"/720 kB floppy services are supported (int 13h) - 3.5"/2.88 MB floppy services are supported (int 13h) - Print screen service is supported (int 5h) - Serial services are supported (int 14h) - Printer services are supported (int 17h) - CGA/mono video services are supported (int 10h) - ACPI is supported - USB legacy is supported - BIOS boot specification is supported - Targeted content distribution is supported - UEFI is supported - BIOS Revision: 5.29 - -Handle 0x0001, DMI type 1, 27 bytes -System Information - Manufacturer: Supermicro - Product Name: SYS-741GE-TNRT - Version: 0123456789 - Serial Number: S512539X3109946 - UUID: 00000000-0000-0000-0000-7cc255275836 - Wake-up Type: Power Switch - SKU Number: To be filled by O.E.M. - Family: Family - -Handle 0x0002, DMI type 2, 15 bytes -Base Board Information - Manufacturer: Supermicro - Product Name: X13DEG-QT - Version: 1.10 - Serial Number: OM22CS039806 - Asset Tag: Base Board Asset Tag - Features: - Board is a hosting board - Board is replaceable - Location In Chassis: Part Component - Chassis Handle: 0x0003 - Type: Motherboard - Contained Object Handles: 0 - -Handle 0x0003, DMI type 3, 22 bytes -Chassis Information - Manufacturer: Supermicro - Type: Other - Lock: Not Present - Version: 0123456789 - Serial Number: C7490FL36A40118 - Asset Tag: Chassis Asset Tag - Boot-up State: Safe - Power Supply State: Safe - Thermal State: Safe - Security Status: None - OEM Information: 0x00000000 - Height: Unspecified - Number Of Power Cords: 1 - Contained Elements: 0 - SKU Number: 0123456789 - -Handle 0x0032, DMI type 4, 50 bytes -Processor Information - Socket Designation: CPU1 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: F8 06 08 00 FF FB EB BF - Signature: Type 0, Family 6, Model 143, Stepping 8 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Platinum 8462Y+ - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4000 MHz - Current Speed: 2800 MHz - Status: Populated, Enabled - Upgrade: Socket LGA4677 - L1 Cache Handle: 0x002F - L2 Cache Handle: 0x0030 - L3 Cache Handle: 0x0031 - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 32 - Core Enabled: 32 - Thread Count: 64 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control - -Handle 0x0036, DMI type 4, 50 bytes -Processor Information - Socket Designation: CPU2 - Type: Central Processor - Family: Xeon - Manufacturer: Intel(R) Corporation - ID: F8 06 08 00 FF FB EB BF - Signature: Type 0, Family 6, Model 143, Stepping 8 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - DS (Debug store) - ACPI (ACPI supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - SS (Self-snoop) - HTT (Multi-threading) - TM (Thermal monitor supported) - PBE (Pending break enabled) - Version: Intel(R) Xeon(R) Platinum 8462Y+ - Voltage: 1.6 V - External Clock: 100 MHz - Max Speed: 4000 MHz - Current Speed: 2800 MHz - Status: Populated, Enabled - Upgrade: Socket LGA4677 - L1 Cache Handle: 0x0033 - L2 Cache Handle: 0x0034 - L3 Cache Handle: 0x0035 - Serial Number: Not Specified - Asset Tag: UNKNOWN - Part Number: Not Specified - Core Count: 32 - Core Enabled: 32 - Thread Count: 64 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control -``` - -## Linux dmidecode memory - -``` -Handle 0x003D, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMA1 - Bank Locator: P0_Node0_Channel0_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A27F - Asset Tag: P1-DIMMA1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x003E, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMB1 - Bank Locator: P0_Node0_Channel1_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A1CC - Asset Tag: P1-DIMMB1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x003F, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMC1 - Bank Locator: P0_Node0_Channel2_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A1B7 - Asset Tag: P1-DIMMC1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0040, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMD1 - Bank Locator: P0_Node0_Channel3_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612927A - Asset Tag: P1-DIMMD1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0041, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMME1 - Bank Locator: P0_Node1_Channel0_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A2B2 - Asset Tag: P1-DIMME1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0042, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMF1 - Bank Locator: P0_Node1_Channel1_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A7F0 - Asset Tag: P1-DIMMF1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0043, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMG1 - Bank Locator: P0_Node1_Channel2_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A1B0 - Asset Tag: P1-DIMMG1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0044, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P1-DIMMH1 - Bank Locator: P0_Node1_Channel3_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD012214961292F4 - Asset Tag: P1-DIMMH1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0045, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMA1 - Bank Locator: P1_Node0_Channel0_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD01221496129322 - Asset Tag: P2-DIMMA1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0046, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMB1 - Bank Locator: P1_Node0_Channel1_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A282 - Asset Tag: P2-DIMMB1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0047, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMC1 - Bank Locator: P1_Node0_Channel2_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612936B - Asset Tag: P2-DIMMC1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0048, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMD1 - Bank Locator: P1_Node0_Channel3_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD012214961292FA - Asset Tag: P2-DIMMD1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x0049, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMME1 - Bank Locator: P1_Node1_Channel0_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD012214961292ED - Asset Tag: P2-DIMME1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x004A, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMF1 - Bank Locator: P1_Node1_Channel1_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A888 - Asset Tag: P2-DIMMF1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x004B, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMG1 - Bank Locator: P1_Node1_Channel2_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A299 - Asset Tag: P2-DIMMG1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None - -Handle 0x004C, DMI type 17, 92 bytes -Memory Device - Array Handle: 0x003C - Error Information Handle: Not Provided - Total Width: 80 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: P2-DIMMH1 - Bank Locator: P1_Node1_Channel3_Dimm0 - Type: DDR5 - Type Detail: Synchronous Registered (Buffered) - Speed: 4800 MT/s - Manufacturer: SK Hynix - Serial Number: 80AD0122149612A195 - Asset Tag: P2-DIMMH1_AssetTag (date:22/14) - Part Number: HMCG88MEBRA107N - Rank: 2 - Configured Memory Speed: 4800 MT/s - Minimum Voltage: 1.1 V - Maximum Voltage: 1.1 V - Configured Voltage: 1.1 V - Memory Technology: DRAM - Memory Operating Mode Capability: Volatile memory - Firmware Version: 0000 - Module Manufacturer ID: Bank 1, Hex 0xAD - Module Product ID: 0xAD00 - Memory Subsystem Controller Manufacturer ID: Unknown - Memory Subsystem Controller Product ID: Unknown - Non-Volatile Size: None - Volatile Size: 32 GB - Cache Size: None - Logical Size: None -``` - -## Xeon ICX Server Firmware Inventory - -``` -Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. Cx-7 Firmware. mlx5. E810 Firmware. ice. -s52-t21-sut1. 10.30.50.52. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. -. -. -s53-t21-tg1. 10.30.50.53. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. -. -. -s54-t22-sut1. 10.30.50.54. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. -. -. 4.00. 1.9.7. -s55-t22-tg1. 10.30.50.55. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. -. -. 3.20. 1.9.7. -s56-t23-sut1. 10.30.50.56. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. 4.00. 1.9.7. -s57-t23-tg1. 10.30.50.57. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. 3.20. 1.9.7. -s58-t24-sut1. 10.30.50.58. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. 4.00. 1.9.7. -s59-t24-tg1. 10.30.50.59. 1.00.2. 1.0. F2.43.09. 0x2b0000c0. 28.34.1002. 5.9-0.5.6.0. 3.20. 1.9.7. -``` diff --git a/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md b/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md deleted file mode 100644 index 457eb9f87f..0000000000 --- a/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md +++ /dev/null @@ -1,634 +0,0 @@ -# SuperMicro Cascadelake Servers - HW and BIOS Configuration - -1. [Linux lscpu](#linux-lscpu) -1. [Linux dmidecode](#dmidecode) -1. [Linux dmidecode pci](#linux-dmidecode-pci) -1. [Linux dmidecode memory](#linux-dmidecode-memory) -1. [EPYC zn2 Server BIOS Configuration](#epyc-zn2-server-bios-configuration) - 1. [Boot Feature](#boot-feature) - 1. [CPU Configuration](#cpu-configuration) - 1. [Advanced Power Management Configuration](#advanced-power-management-configuration) - 1. [CPU P State Control](#cpu-p-state-control) - 1. [Hardware PM State Control](#hardware-pm-state-control) - 1. [CPU C State Control](#cpu-c-state-control) - 1. [Package C State Control](#package-c-state-control) - 1. [CPU T State Control](#cpu-t-state-control) - 1. [Chipset Configuration](#chipset-configuration) - 1. [North Bridge](#north-bridge) - 1. [UPI Configuration](#upi-configuration) - 1. [Memory Configuration](#memory-configuration) - 1. [IIO Configuration](#iio-configuration) - 1. [CPU1 Configuration](#cpu1-configuration) - 1. [CPU2 Configuration](#cpu2-configuration) - 1. [South Bridge](#south-bridge) - 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration) - 1. [ACPI Settings](#acpi-settings) -1. [EPYC zn2 Server Firmware Inventory](#epyc-zn2-server-firmware-inventory) - -## Linux lscpu - -``` -$ lscpu -Architecture: x86_64 -CPU op-mode(s): 32-bit, 64-bit -Byte Order: Little Endian -CPU(s): 64 -On-line CPU(s) list: 0-63 -Thread(s) per core: 2 -Core(s) per socket: 32 -Socket(s): 1 -NUMA node(s): 2 -Vendor ID: AuthenticAMD -CPU family: 23 -Model: 49 -Model name: AMD EPYC 7532 32-Core Processor -Stepping: 0 -CPU MHz: 1981.470 -CPU max MHz: 2400.0000 -CPU min MHz: 1500.0000 -BogoMIPS: 4800.05 -Virtualization: AMD-V -L1d cache: 32K -L1i cache: 32K -L2 cache: 512K -L3 cache: 16384K -NUMA node0 CPU(s): 0-15,32-47 -NUMA node1 CPU(s): 16-31,48-63 -Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm constant_tsc rep_good nopl xtopology nonstop_tsc cpuid extd_apicid aperfmperf pni pclmulqdq monitor ssse3 fma cx16 sse4_1 sse4_2 x2apic movbe popcnt aes xsave avx f16c rdrand lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs skinit wdt tce topoext perfctr_core perfctr_nb bpext perfctr_llc mwaitx cpb cat_l3 cdp_l3 hw_pstate sme ssbd ibrs ibpb stibp vmmcall fsgsbase bmi1 avx2 smep bmi2 cqm rdt_a rdseed adx smap clflushopt clwb sha_ni xsaveopt xsavec xgetbv1 xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local clzero irperf xsaveerptr arat npt lbrv svm_lock nrip_save tsc_scale vmcb_clean flushbyasid decodeassists pausefilter pfthreshold avic v_vmsave_vmload vgif umip rdpid overflow_recov succor smca -``` - -``` -$ lscpu -Architecture: x86_64 -CPU op-mode(s): 32-bit, 64-bit -Byte Order: Little Endian -CPU(s): 64 -On-line CPU(s) list: 0-63 -Thread(s) per core: 2 -Core(s) per socket: 32 -Socket(s): 1 -NUMA node(s): 2 -Vendor ID: AuthenticAMD -CPU family: 23 -Model: 49 -Model name: AMD EPYC 7532 32-Core Processor -Stepping: 0 -CPU MHz: 1981.470 -CPU max MHz: 2400.0000 -CPU min MHz: 1500.0000 -BogoMIPS: 4800.05 -Virtualization: AMD-V -L1d cache: 32K -L1i cache: 32K -L2 cache: 512K -L3 cache: 16384K -NUMA node0 CPU(s): 0-15,32-47 -NUMA node1 CPU(s): 16-31,48-63 -Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm constant_tsc rep_good nopl xtopology nonstop_tsc cpuid extd_apicid aperfmperf pni pclmulqdq monitor ssse3 fma cx16 sse4_1 sse4_2 x2apic movbe popcnt aes xsave avx f16c rdrand lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs skinit wdt tce topoext perfctr_core perfctr_nb bpext perfctr_llc mwaitx cpb cat_l3 cdp_l3 hw_pstate sme ssbd ibrs ibpb stibp vmmcall fsgsbase bmi1 avx2 smep bmi2 cqm rdt_a rdseed adx smap clflushopt clwb sha_ni xsaveopt xsavec xgetbv1 xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local clzero irperf xsaveerptr arat npt lbrv svm_lock nrip_save tsc_scale vmcb_clean flushbyasid decodeassists pausefilter pfthreshold avic v_vmsave_vmload vgif umip rdpid overflow_recov succor smca -``` - -## Linux dmidecode - -``` - $ dmidecode -t slot - Handle 0x0026, DMI type 7, 27 bytes - Cache Information - Socket Designation: L1 Cache - Configuration: Enabled, Not Socketed, Level 1 - Operational Mode: Write Back - Location: Internal - Installed Size: 2048 kB - Maximum Size: 2048 kB - Supported SRAM Types: - Pipeline Burst - Installed SRAM Type: Pipeline Burst - Speed: 1 ns - Error Correction Type: Multi-bit ECC - System Type: Unified - Associativity: 8-way Set-associative - - Handle 0x0027, DMI type 7, 27 bytes - Cache Information - Socket Designation: L2 Cache - Configuration: Enabled, Not Socketed, Level 2 - Operational Mode: Write Back - Location: Internal - Installed Size: 16384 kB - Maximum Size: 16384 kB - Supported SRAM Types: - Pipeline Burst - Installed SRAM Type: Pipeline Burst - Speed: 1 ns - Error Correction Type: Multi-bit ECC - System Type: Unified - Associativity: 8-way Set-associative - - Handle 0x0028, DMI type 7, 27 bytes - Cache Information - Socket Designation: L3 Cache - Configuration: Enabled, Not Socketed, Level 3 - Operational Mode: Write Back - Location: Internal - Installed Size: 262144 kB - Maximum Size: 262144 kB - Supported SRAM Types: - Pipeline Burst - Installed SRAM Type: Pipeline Burst - Speed: 1 ns - Error Correction Type: Multi-bit ECC - System Type: Unified - Associativity: 16-way Set-associative - - Handle 0x0029, DMI type 4, 48 bytes - Processor Information - Socket Designation: CPU - Type: Central Processor - Family: Zen - Manufacturer: Advanced Micro Devices, Inc. - ID: 10 0F 83 00 FF FB 8B 17 - Signature: Family 23, Model 49, Stepping 0 - Flags: - FPU (Floating-point unit on-chip) - VME (Virtual mode extension) - DE (Debugging extension) - PSE (Page size extension) - TSC (Time stamp counter) - MSR (Model specific registers) - PAE (Physical address extension) - MCE (Machine check exception) - CX8 (CMPXCHG8 instruction supported) - APIC (On-chip APIC hardware supported) - SEP (Fast system call) - MTRR (Memory type range registers) - PGE (Page global enable) - MCA (Machine check architecture) - CMOV (Conditional move instruction supported) - PAT (Page attribute table) - PSE-36 (36-bit page size extension) - CLFSH (CLFLUSH instruction supported) - MMX (MMX technology supported) - FXSR (FXSAVE and FXSTOR instructions supported) - SSE (Streaming SIMD extensions) - SSE2 (Streaming SIMD extensions 2) - HTT (Multi-threading) - Version: AMD EPYC 7532 32-Core Processor - Voltage: 1.1 V - External Clock: 100 MHz - Max Speed: 3300 MHz - Current Speed: 2400 MHz - Status: Populated, Enabled - Upgrade: Socket SP3 - L1 Cache Handle: 0x0026 - L2 Cache Handle: 0x0027 - L3 Cache Handle: 0x0028 - Serial Number: Unknown - Asset Tag: Unknown - Part Number: Unknown - Core Count: 32 - Core Enabled: 32 - Thread Count: 64 - Characteristics: - 64-bit capable - Multi-Core - Hardware Thread - Execute Protection - Enhanced Virtualization - Power/Performance Control -``` - -## Linux dmidecode pci - -``` - $ dmidecode -t slot - Getting SMBIOS data from sysfs. - SMBIOS 3.2.0 present. - # SMBIOS implementations newer than version 3.1.1 are not - # fully supported by this version of dmidecode. - - Handle 0x000A, DMI type 9, 17 bytes - System Slot Information - Designation: M.2-HC1 CPU PCI-E 4.0 X4/X2 - Type: x4 PCI Express 3 x4 - Current Usage: Available - Length: Short - ID: 1 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x000B, DMI type 9, 17 bytes - System Slot Information - Designation: M.2-HC2 CPU PCI-E 4.0 X2 - Type: x2 PCI Express 3 x2 - Current Usage: Available - Length: Short - ID: 2 - Characteristics: - 3.3 V is provided - Opening is shared - PME signal is supported - Bus Address: 0000:ff:00.0 - - Handle 0x0042, DMI type 9, 17 bytes - System Slot Information - Designation: RSC-W-66G4 SLOT1 PCI-E 4.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: In Use - Length: Long - ID: 1 - Characteristics: - 3.3 V is provided - PME signal is supported - Bus Address: 0000:41:00.0 - - Handle 0x0043, DMI type 9, 17 bytes - System Slot Information - Designation: RSC-W-66G4 SLOT2 PCI-E 4.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: In Use - Length: Long - ID: 2 - Characteristics: - 3.3 V is provided - PME signal is supported - Bus Address: 0000:81:00.0 - - Handle 0x0045, DMI type 9, 17 bytes - System Slot Information - Designation: RSC-WR-6 SLOT1 PCI-E 4.0 X16 - Type: x16 PCI Express 3 x16 - Current Usage: In Use - Length: Long - ID: 1 - Characteristics: - 3.3 V is provided - PME signal is supported - Bus Address: 0000:01:00.0 - -``` - -## Linux dmidecode memory - -``` - $ dmidecode -t memory - # dmidecode 3.1 - Getting SMBIOS data from sysfs. - SMBIOS 3.2.0 present. - # SMBIOS implementations newer than version 3.1.1 are not - # fully supported by this version of dmidecode. - - Handle 0x0023, DMI type 16, 23 bytes - Physical Memory Array - Location: System Board Or Motherboard - Use: System Memory - Error Correction Type: Multi-bit ECC - Maximum Capacity: 2 TB - Error Information Handle: 0x0022 - Number Of Devices: 8 - - Handle 0x002B, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x002A - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMA1 - Bank Locator: P0_Node0_Channel0_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9216 - Asset Tag: P1-DIMMA1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x002E, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x002D - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMB1 - Bank Locator: P0_Node0_Channel1_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E91D2 - Asset Tag: P1-DIMMB1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0031, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x0030 - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMC1 - Bank Locator: P0_Node0_Channel2_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E918A - Asset Tag: P1-DIMMC1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0034, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x0033 - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMD1 - Bank Locator: P0_Node0_Channel3_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9187 - Asset Tag: P1-DIMMD1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0037, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x0036 - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMME1 - Bank Locator: P0_Node0_Channel4_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9178 - Asset Tag: P1-DIMME1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x003A, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x0039 - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMF1 - Bank Locator: P0_Node0_Channel5_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9206 - Asset Tag: P1-DIMMF1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x003D, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x003C - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMG1 - Bank Locator: P0_Node0_Channel6_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9207 - Asset Tag: P1-DIMMG1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V - - Handle 0x0040, DMI type 17, 84 bytes - Memory Device - Array Handle: 0x0023 - Error Information Handle: 0x003F - Total Width: 72 bits - Data Width: 64 bits - Size: 32 GB - Form Factor: DIMM - Set: None - Locator: DIMMH1 - Bank Locator: P0_Node0_Channel7_Dimm0 - Type: DDR4 - Type Detail: Synchronous Registered (Buffered) - Speed: 3200 MT/s - Manufacturer: SK Hynix - Serial Number: 431E9209 - Asset Tag: P1-DIMMH1_AssetTag (date:19/00) - Part Number: HMA84GR7CJR4N-XN - Rank: 2 - Configured Clock Speed: 3200 MT/s - Minimum Voltage: 1.2 V - Maximum Voltage: 1.2 V - Configured Voltage: 1.2 V -``` - -## EPYC zn2 Server BIOS Configuration - TG - -### Boot Feature - -``` - | Quiet Boot [Enabled] |Boot option | - | | | - | Option ROM Messages [Force BIOS] | | - | Bootup NumLock State [On] | | - | Wait For "F1" If Error [Enabled] | | - | INT19 Trap Response [Immediate] | | - | Re-try Boot [Disabled] | | - | | | - | Power Configuration | | - | Watch Dog Function [Disabled] | | - | Restore on AC Power Loss [Last State] | | - | Power Button Function [Instant Off] | | -``` - -### CPU Configuration - -``` - | ACPI Settings ^| | - | -------------------------------------------------- *| | - | PCI AER Support [Disabled] *| | - | High Precision Event Timer [Disabled] *| | - | NUMA Nodes Per Socket [NPS2] *| | - | ACPI SRAT L3 Cache As NUMA Domain [Auto] *| | - | *| | - | CPU Configuration ^| | - | -------------------------------------------------- *| | - | SMT Control [Auto] *| | - | Core Performance Boost [Auto] *| | - | Global C-state control [Disabled] *| | - | Local APIC Mode [Auto] *| | - | CCD Control [Auto] *| | - | Core Control [Auto] *| | - | Core Control [Auto] *| | - | L1 Stream HW Prefetcher [Enabled] *| | - | L2 Stream HW Prefetcher [Enabled] *| | - | SVM Mode [Enabled] *| | - | SMEE [Disabled] *| | - | *| | - |> CPU1 Information *| | - | *| | - | NB Configuration ^| | - | -------------------------------------------------- *| | - | Determinism Control [Manual] *| | - | Determinism Slider [Performance] *| | - | cTDP Control [Disabled] *| | - | IOMMU [Disabled] *| | - | ACS Enable [Auto] *| | - | Package Power Limit Control [Auto] *| | - | APBDIS [1] *| | - | Fixed SOC Pstate [P0] *| | - | DF Cstates [Enabled] *| | - | Preferred IO [Manual] *| | - | Preferred IO Bus [##] *| | - | *| | - | *|-----------------------------| - | *|><: Select Screen | - | *|^v: Select Item | - | *|Enter: Select | - | +|+/-: Change Opt. | - | +|F1: General Help | - | +|F2: Previous Values | - | +|F3: Optimized Defaults | - | v|F4: Save & Exit | - | | | -``` - - -## EPYC zn2 Server BIOS Configuration - DUT - -### Boot Feature - -``` - | Quiet Boot [Enabled] |Boot option | - | | | - | Option ROM Messages [Force BIOS] | | - | Bootup NumLock State [On] | | - | Wait For "F1" If Error [Enabled] | | - | INT19 Trap Response [Immediate] | | - | Re-try Boot [Disabled] | | - | | | - | Power Configuration | | - | Watch Dog Function [Disabled] | | - | Restore on AC Power Loss [Last State] | | - | Power Button Function [Instant Off] | | -``` - -### CPU Configuration - -``` - | ACPI Settings ^| | - | -------------------------------------------------- *| | - | PCI AER Support [Disabled] *| | - | High Precision Event Timer [Disabled] *| | - | NUMA Nodes Per Socket [NPS2] *| | - | ACPI SRAT L3 Cache As NUMA Domain [Auto] *| | - | *| | - | CPU Configuration ^| | - | -------------------------------------------------- *| | - | SMT Control [Auto] *| | - | Core Performance Boost [Auto] *| | - | Global C-state control [Disabled] *| | - | Local APIC Mode [Auto] *| | - | CCD Control [Auto] *| | - | Core Control [Auto] *| | - | Core Control [Auto] *| | - | L1 Stream HW Prefetcher [Enabled] *| | - | L2 Stream HW Prefetcher [Enabled] *| | - | SVM Mode [Enabled] *| | - | SMEE [Disabled] *| | - | *| | - |> CPU1 Information *| | - | *| | - | NB Configuration ^| | - | -------------------------------------------------- *| | - | Determinism Control [Manual] *| | - | Determinism Slider [Performance] *| | - | cTDP Control [Disabled] *| | - | IOMMU [Disabled] *| | - | ACS Enable [Auto] *| | - | Package Power Limit Control [Auto] *| | - | APBDIS [1] *| | - | Fixed SOC Pstate [P0] *| | - | DF Cstates [Enabled] *| | - | Preferred IO [Manual] *| | - | Preferred IO Bus [##] *| | - | *| | - | *|-----------------------------| - | *|><: Select Screen | - | *|^v: Select Item | - | *|Enter: Select | - | +|+/-: Change Opt. | - | +|F1: General Help | - | +|F2: Previous Values | - | +|F3: Optimized Defaults | - | v|F4: Save & Exit | - | | | -``` - - -## EPYC zn2 Server Firmware Inventory - -``` -Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. PCI Bus. X710 Firmware. XXV710 Firmware. i40e. MLX5 Firmware. mlx5_core -s60-t210-sut1. 10.30.55.24. 03.10.04. 1.1a. 02.c2.00. 0x8301038. ?. 8.70. 8.70. 2.19.3. 16.32.1010. 5.6-1.0.3.3. -s61-t210-tg1. 10.30.55.25. 03.10.04. 1.1a. 02.c2.00. 0x8301038. ?. 8.30. 8.30. 2.19.3. 16.32.1010. 5.6-1.0.3.3. -``` \ No newline at end of file -- cgit 1.2.3-korg