--- bookToc: true title: "FD.io DC Testbed Specifications" weight: 2 --- # FD.io DC Testbed Specifications ## Purpose This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project. ## Server Management ### Addressing Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. #### LOM (IPMI) VLAN - Subnet: 10.30.50.0/24 - Gateway: 10.30.50.1 - Broadcast: 10.30.50.255 - DNS1: 199.204.44.24 - DNS2: 199.204.47.54 #### Management VLAN - Subnet: 10.30.51.0/24 - Gateway: 10.30.51.1 - Broadcast: 10.30.51.255 - DNS1: 199.204.44.24 - DNS2: 199.204.47.54 To access these hosts, VPN connection is required. ## Testbeds Overview ### Summary List ``` #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 1-Node-Cascadelake Xeon Intel (1n-clx) Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io TCP/IP and HTTP performance tests. ### 2-Node-Cascadelake Xeon Intel (2n-clx) Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and one TG (Server-Type-C3) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Zen2 EPYC AMD (2n-zn2) Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and one TG (Server-Type-D2) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-ThunderX2 Arm Marvell (2x-tx2) Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and one TG (Server-Type-E31) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Icelake Xeon Intel (2n-icx) Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and one TG (Server-Type-F2) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Rangeley Atom Testbeds Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one TG (Server-Type-2) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-TaiShan Arm Huawei (3n-tsh) Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one TG (Server-Type-E31) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Altra Arm Ampere (3n-alt) Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one TG (Server-Type-F4) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Icelake Xeon Intel (3n-icx) Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one TG (Server-Type-F3) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-SnowRidge Atom Intel (3n-snr) Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one TG (Server-Type-F4) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and one TG (Server-Type-H2) connected in a 2-node physical topology with NUMA (socket) daisy chaining. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). Used for FD.io performance tests in a full system SUT setup with all PCIe Gen5 x16 lane slots populated with 2p200GbE NICs. ### 2-Node-SapphireRapids Xeon Intel (2n-spr) Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and one TG (Server-Type-H6) connected in a 2-node circular topology. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). Used for FD.io performance tests. ## Tesdtbed Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: - **testbedname**: testbedN. - **hostname**: - traffic-generator: tN-tgW. - system-under-testX: tN-sutX. - **portnames**: - tN-tgW-cY/pZ. - tN-sutX-cY/pZ. - **where**: - N - testbed number. - tgW - server acts as traffic-generator with W index. - sutX - server acts as system-under-test with X index. - Y - PCIe slot number denoting a NIC card number within the host. - Z - port number on the NIC card. ## Server Types FD.io CSIT lab contains following server types: 1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: empty. - PCIe Slot4 3b:00.xx: empty. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. - 8-port 10GE SFP+ integrated NIC. - Main HW configuration: - Chassis: PS10GE4NG. - Motherboard: SuperMicro X11DPG-QT. - Processors: Quad-Core, Intel Processor. - HW accelerators: FPGA offload. - RAM Memory: 64GB. - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - Physical Interfaces: 4 * 10GE SFP+. - Operating System: Native IxOS. - Interface configuration: - Port-1: 10GE SFP+. - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. 4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: empty. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8280 2.7 GHz. - RAM Memory: 12* 16GB DDR4-2933. - Disks: 2* 1.92TB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Gold 6252N 2.3 GHz. - RAM Memory: 12* 16GB DDR4-2933. - Disks: 2* 1.92TB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8280 2.7 GHz. - RAM Memory: 12* 16GB DDR4-2933. - Disks: 2* 1.92TB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot10 d8:00.xx: empty. 8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. - no NIC ports, standalone setup. - Main HW configuration: - Chassis: SuperMicro 1029P-WTRT. - Motherboard: SuperMicro X11DDW-NT. - Processors: 2* Intel Platinum 8280 2.7 GHz. - RAM Memory: 12* 16GB DDR4-2933. - Disks: 4* 1.92TB SATA SSD. - NICs configuration: - Numa0: - no cards. - Numa1: - no cards. 9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro AS-1114S-WTRT - Processors: 1* AMD EPYC 7532 2.4 GHz. - RAM Memory: 8* 32GB DDR4-2933. - Disks: 1* 1TB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. 10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro AS-1114S-WTRT - Processors: 1* AMD EPYC 7532 2.4 GHz. - RAM Memory: 8* 32GB DDR4-2933. - Disks: 1* 1TB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. 11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: GIGABYTE Rack Mount - Motherboard: MT91-FS4-00 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - RAM Memory: 16 * 16GB DIMM - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - NICs configuration: - Numa0: - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - Numa1: - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. 12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. - NIC ports connected into 3-node topology. - Main HW configuration: - Chassis: Huawei TaiShan 2280. - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - RAM Memory: 8* 16GB DDR4-2400MT/s - Disks: 1* 4TB SATA HDD - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: x520-2p10GE Intel. 13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node topologies. - Main HW configuration: - Chassis: Gigabyte R181-T90 1U - Motherboard: MT91-FS1 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - no cards - Numa1: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. 14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node topologies. - Main HW configuration: - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U - Motherboard: Mt.Jade Motherboard - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 - RAM Memory: 16* 8GB DDR4-3200MT/s - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - NICs configuration: - Numa0: - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - Numa1: - no cards. 15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - Main HW configuration: - Chassis: Gigabyte R152-P30-00 1U - Motherboard: MP32-AR1-00 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - RAM Memory: 12* 16GB DDR4-3200MT/s - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and 3-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. 17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 8. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node or 3-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-740GP-TNRT. - Motherboard: Super X12DPG-QT6. - Processors: 2* Intel Platinum 8358 2.6 GHz. - RAM Memory: 16* 16GB DDR4-3200. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-740GP-TNRT. - Motherboard: Super X12DPG-QT6. - Processors: 2* Intel Platinum 8358 2.6 GHz. - RAM Memory: 16* 16GB DDR4-3200. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-740GP-TNRT. - Motherboard: Super X12DPG-QT6. - Processors: 2* Intel Platinum 8358 2.6 GHz. - RAM Memory: 16* 16GB DDR4-3200. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and/or 3-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-740GP-TNRT. - Motherboard: Super X12DPG-QT6. - Processors: 2* Intel Platinum 8358 2.6 GHz. - RAM Memory: 16* 16GB DDR4-3200. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot4 3b:00.xx: empty. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. 21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node testbed topology. - Main HW configuration: - Chassis: Intel JACOBSVILLE SDP. - Motherboard: Intel JACOBSVILLE E63448-400. - Processors: 1* Intel Atom P5362B 2.2 GHz. - RAM Memory: 2* 16GB DDR4-2933. - Disks: ?* ? SATA SSD. - NICs configuration: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. 22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-numa-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. 23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-numa-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. 24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-numa-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot10 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. 25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-numa-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot10 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: empty. - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. 26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: empty. - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. 27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test. - Main HW configuration: - Chassis: SuperMicro SYS-741GE-TNRT. - Motherboard: Super X13DEG-QT-P. - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - RAM Memory: 16* 32GB DDR5-4800. - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot11 d8:00.xx: empty. ## Testbeds Configuration ### 1-Node-Skylake (1n-skx) ``` - SUT [Server-Type-B6]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 - Host IP: 10.30.51.50 - portnames: - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. - SUT [Server-Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 - Host IP: 10.30.51.51 - portnames: - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` ### 1-Node-ThunderX2 (1n-tx2) ``` - SUT [Server-Type-E11]: - testbedname: testbed13 - hostname: s55-t13-sut1 - IPMI IP: 10.30.50.70 - Host IP: 10.30.51.70 - portnames: - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - SUT [Server-Type-E11]: - testbedname: testbed14 - hostname: s56-t14-sut1 - IPMI IP: 10.30.50.71 - Host IP: 10.30.51.71 - portnames: - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` ### 1-Node-Cascadelake (1n-clx) ``` - SUT [Server-Type-C1]: - testbedname: testbed11. - hostname: s32-t14-sut1. - IPMI IP: 10.30.55.17 - Host IP: 10.32.8.17 - portnames: - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` ### 2-Node-IxiaPS1L47 (2n-ps1) ``` - SUT [Server-Type-B8]: - testbedname: testbed25. - hostname: s25-t25-sut1. - IPMI IP: 10.30.50.58 - Host IP: 10.30.51.61 - portnames: - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - TG [Server-Type-B7]: - testbedname: testbed25. - hostname: s26-t25-tg1. - IPMI IP: 10.30.50.59 - Host IP: 10.30.51.62 - portnames: - s26-t25-tg1-p1 - 10GE-port1. - s26-t25-tg1-p2 - 10GE-port2. - s26-t25-tg1-p3 - 10GE-port3. - s26-t25-tg1-p4 - 10GE-port4. ``` ### 2-Node-Cascadelake (2n-clx) {{< figure src="/cdocs/testbed-2n-clx.svg" >}} ``` - SUT [Server-Type-C2]: - testbedname: testbed27. - hostname: s33-t27-sut1. - IPMI IP: 10.30.55.18 - Host IP: 10.32.8.18 - portnames: - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: - testbedname: testbed27. - hostname: s34-t27-tg1. - IPMI IP: 10.30.55.19 - Host IP: 10.32.8.19 - portnames: - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: - testbedname: testbed28. - hostname: s35-t28-sut1. - IPMI IP: 10.30.55.20 - Host IP: 10.32.8.20 - portnames: - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: - testbedname: testbed28. - hostname: s36-t28-tg1. - IPMI IP: 10.30.55.21 - Host IP: 10.32.8.21 - portnames: - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: - testbedname: testbed29. - hostname: s37-t29-sut1. - IPMI IP: 10.30.55.22 - Host IP: 10.32.8.22 - portnames: - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: - testbedname: testbed29. - hostname: s38-t29-tg1. - IPMI IP: 10.30.55.23 - Host IP: 10.32.8.23 - portnames: - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. ``` ### 2-Node-Zen2 (2n-zn2) {{< figure src="/cdocs/testbed-2n-zn2.svg" >}} ``` - SUT [Server-Type-D1]: - testbedname: testbed210. - hostname: s60-t210-sut1. - IPMI IP: 10.30.55.24 - Host IP: 10.32.8.24 - portnames: - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-D2]: - testbedname: testbed210. - hostname: s61-t210-tg1. - IPMI IP: 10.30.55.25 - Host IP: 10.32.8.25 - portnames: - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` ### 2-Node-ThunderX2 (2x-tx2) {{< figure src="/cdocs/testbed-2n-tx2.svg" >}} ``` - SUT [Server-Type-E22]: - testbedname: testbed211. - hostname: s27-t211-sut1. - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. - TG [Server-Type-E31]: - testbedname: testbed33 and testbed211. - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` ### 2-Node-Icelake (2n-icx) {{< figure src="/cdocs/testbed-2n-icx.svg" >}} ``` - SUT [Server-Type-F1]: - testbedname: testbed212. - hostname: s71-t212-sut1. - IPMI IP: 10.30.50.81 - Host IP: 10.30.51.81 - portnames: - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - TG [Server-Type-F2]: - testbedname: testbed212. - hostname: s72-t212-tg1. - IPMI IP: 10.30.50.82 - Host IP: 10.30.51.82 - portnames: - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - SUT [Server-Type-F1]: - testbedname: testbed213. - hostname: s83-t213-sut1. - IPMI IP: 10.30.50.83 - Host IP: 10.30.51.83 - portnames: - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - TG [Server-Type-F2]: - testbedname: testbed213. - hostname: s84-t213-tg1. - IPMI IP: 10.30.50.84 - Host IP: 10.30.51.84 - portnames: - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - SUT [Server-Type-F1]: - testbedname: testbed214. - hostname: s85-t214-sut1. - IPMI IP: 10.30.50.85 - Host IP: 10.30.51.85 - portnames: - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - TG [Server-Type-F2]: - testbedname: testbed214. - hostname: s86-t214-tg1. - IPMI IP: 10.30.50.86 - Host IP: 10.30.51.86 - portnames: - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - SUT [Server-Type-F1]: - testbedname: testbed215. - hostname: s87-t215-sut1. - IPMI IP: 10.30.50.87 - Host IP: 10.30.51.87 - portnames: - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - TG [Server-Type-F2]: - testbedname: testbed215. - hostname: s88-t215-tg1. - IPMI IP: 10.30.50.88 - Host IP: 10.30.51.88 - portnames: - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` ### 3-Node-Rangeley (3n-rng) Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` - ServerB22 [Server-Type-B5]: - testbedname: testbed35. - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 - Host IP: 10.30.51.9 - portnames: - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) - ServerB23 [Server-Type-B5]: - testbedname: testbed35. - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 - Host IP: 10.30.51.10 - portnames: - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) - ServerB24 [Server-Type-B5]: - testbedname: testbed35. - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 - Host IP: 10.30.51.11 - portnames: - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) ``` ### 3-Node-Taishan (3n-tsh) {{< figure src="/cdocs/testbed-3n-tsh.svg" >}} ``` - SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 - Host IP: 10.30.51.36 - portnames: - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE. - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. - SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 - Host IP: 10.30.51.37 - portnames: - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE. - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. - TG [Server-Type-E31]: - testbedname: testbed33 and testbed211. - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` ### 3-Node-Altra (3n-alt) {{< figure src="/cdocs/testbed-3n-alt.svg" >}} ``` - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s62-t34-sut1. - IPMI IP: 10.30.50.72 - Host IP: 10.30.51.72 - portnames: - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. - IPMI IP: 10.30.50.73 - Host IP: 10.30.51.73 - portnames: - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - TG [Server-Type-F4]: - testbedname: testbed34. - hostname: s64-t34-tg1. - IPMI IP: 10.30.50.74 - Host IP: 10.30.51.74 - portnames: - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` ### 3-Node-Icelake (3n-icx) {{< figure src="/cdocs/testbed-3n-icx.svg" >}} ``` - ServerF1 [Server-Type-F1]: - testbedname: testbed37. - hostname: s65-t37-sut1. - IPMI IP: 10.30.50.75 - Host IP: 10.30.51.75 - portnames: - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - ServerF1 [Server-Type-F1]: - testbedname: testbed37. - hostname: s66-t37-sut2. - IPMI IP: 10.30.50.76 - Host IP: 10.30.51.76 - portnames: - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - ServerF3 [Server-Type-F3]: - testbedname: testbed37. - hostname: s67-t37-tg1. - IPMI IP: 10.30.50.77 - Host IP: 10.30.51.77 - portnames: - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - ServerF1 [Server-Type-F1]: - testbedname: testbed38. - hostname: s78-t38-sut1. - IPMI IP: 10.30.50.78 - Host IP: 10.30.51.78 - portnames: - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - ServerF1 [Server-Type-F1]: - testbedname: testbed38. - hostname: s79-t38-sut2. - IPMI IP: 10.30.50.79 - Host IP: 10.30.51.79 - portnames: - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - ServerF3 [Server-Type-F3]: - testbedname: testbed38. - hostname: s80-t38-tg1. - IPMI IP: 10.30.50.80 - Host IP: 10.30.51.80 - portnames: - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` ### 3-Node-SnowRidge (3n-snr) {{< figure src="/cdocs/testbed-3n-snr.svg" >}} ``` - ServerG1 [Server-Type-G1]: - testbedname: testbed39. - hostname: s93-t39-sut1. - IPMI IP: 10.30.50.93 - Host IP: 10.30.51.93 - portnames: - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE. - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE. - ServerG1 [Server-Type-G1]: - testbedname: testbed39. - hostname: s94-t39-sut2. - IPMI IP: 10.30.50.94 - Host IP: 10.30.51.94 - portnames: - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - ServerF4 [Server-Type-F4]: - testbedname: testbed39. - hostname: s89-t39t310-tg1. - IPMI IP: 10.30.50.89 - Host IP: 10.30.51.89 - portnames: - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. ``` ### 2-Node-SapphireRapids (2n-spr) {{< figure src="/cdocs/testbed-2n-spr.svg" >}} ``` - SUT [Server-Type-H1]: - testbedname: testbed21. - hostname: s52-t21-sut1. - IPMI IP: 10.30.50.52 - Host IP: 10.30.51.52 - portnames: - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - TG [Server-Type-H2]: - testbedname: testbed21. - hostname: s53-t21-tg1. - IPMI IP: 10.30.50.53 - Host IP: 10.30.51.53 - portnames: - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - SUT [Server-Type-H3]: - testbedname: testbed22. - hostname: s54-t22-sut1. - IPMI IP: 10.30.50.54 - Host IP: 10.30.51.54 - portnames: - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - TG [Server-Type-H4]: - testbedname: testbed22. - hostname: s55-t22-tg1. - IPMI IP: 10.30.50.55 - Host IP: 10.30.51.55 - portnames: - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - SUT [Server-Type-H5]: - testbedname: testbed23. - hostname: s56-t23-sut1. - IPMI IP: 10.30.50.56 - Host IP: 10.30.51.56 - portnames: - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - TG [Server-Type-H6]: - testbedname: testbed23. - hostname: s57-t23-tg1. - IPMI IP: 10.30.50.57 - Host IP: 10.30.51.57 - portnames: - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - SUT [Server-Type-H5]: - testbedname: testbed24. - hostname: s58-t24-sut1. - IPMI IP: 10.30.50.58 - Host IP: 10.30.51.58 - portnames: - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - TG [Server-Type-H6]: - testbedname: testbed24. - hostname: s59-t24-tg1. - IPMI IP: 10.30.50.59 - Host IP: 10.30.51.59 - portnames: - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` ## Testbed Wiring ### 1-Node-Skylake (1n-skx) ``` - testbed11: - ring1 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. - ring2 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. - ring3 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. - ring5 100GE-ports e810-2p100GE: - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. - ring6 100GE-ports e810-2p100GE: - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. - testbed12: - ring1 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. - ring2 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. - ring3 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. - ring5 100GE-ports e810-2p100GE: - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. - ring6 100GE-ports e810-2p100GE: - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. ``` ### 1-Node-ThunderX2 (1n-tx2) ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. - testbed14: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` ### 2-Node-IxiaPS1L47 (2n-ps1) ``` - testbed25: - link1 10GE-port x710-4p10GE on SUT: - t25-tg1-p1 to t25-sut1-c2/p1. - link2 10GE-port x710-4p10GE on SUT: - t25-tg1-p2 to t25-sut1-c2/p2. - link3 10GE-port x710-4p10GE on SUT: - t25-tg1-p3 to t25-sut1-c2/p3. - link4 10GE-port x710-4p10GE on SUT: - t25-tg1-p4 to t25-sut1-c2/p4. ``` ### 2-Node-Cascadelake (2n-clx) ``` - testbed27: - ring1 10GE-ports x710-4p10GE on SUT: - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. - ring6 100GE-ports e810-2p100GE on TG: - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. - testbed28: - ring1 10GE-ports x710-4p10GE on SUT: - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. - ring6 100GE-ports e810-2p100GE on TG: - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. - testbed29: - ring1 10GE-ports x710-4p10GE on SUT: - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. ``` ### 2-Node-Zen2 (2n-zn2) ``` - testbed210: - ring1 10GE-ports x710-4p10GE on SUT: - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. ``` ### 2-Node-ThunderX2 (2n-tx2) ``` - testbed211: - ring1 10GE-ports x520-2p10GE on SUTs: - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. ``` ### 2-Node-Icelake (2n-icx) ``` - testbed212: - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. - testbed213: - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. - testbed214: - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. - testbed215: - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. ``` ### 3-Node-Rangeley (3n-rng) ``` To be completed. ``` ### 3-Node-Taishan (3n-tsh) ``` - testbed33: - ring1 10GE-ports x520-2p10GE on SUTs: - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. ``` ### 3-Node-Altra (3n-alt) ``` - testbed34: - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. ``` ### 3-Node-Icelake (3n-icx) ``` - testbed37: - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. - testbed38: - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. ``` ### 3-Node-SnowRidge (3n-snr) ``` - testbed39: - ring1 25GE-ports e810-XXVDA4-4p25GE: - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3. - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4. - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. ``` ### 2-Node-SapphireRapids (2n-spr) ``` - testbed21: - ring1 200GE-ports ConnectX7-2p200GE: - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1 - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1 - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2 - ring2 200GE-ports ConnectX7-2p200GE: - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2 - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2 - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1 - ring3 200GE-ports ConnectX7-2p200GE: - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1 - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1 - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2 - testbed22: - ring1 100GE-ports e810-2CQDA2-2p100GE: - s55-t22-tg1-c4/p1 to s54-t22-sut1-c9/p2 - s55-t22-tg1-c4/p2 to s54-t22-sut1-c4/p2 - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1 - ring2 25GE-ports e810-XXVDA4-4p25GE: - s55-t22-tg1-c2/p1 to s54-t22-sut1-c2/p1 - s55-t22-tg1-c2/p2 to s54-t22-sut1-c7/p1 - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2 - testbed23: - ring1 200GE-ports ConnectX7-2p200GE: - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1. - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2. - ring2 100GE-ports e810-2CQDA2-2p100GE: - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. - ring3 25GE-ports e810-XXVDA4-2p25GE: - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4. - ring4 200GE-ports ConnectX7-2p200GE: - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2. - ring5 100GE-ports e810-2CQDA2-2p100GE: - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2. - testbed24: - ring1 200GE-ports ConnectX7-2p200GE: - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1. - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2. - ring2 100GE-ports e810-2CQDA2-2p100GE: - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. - ring3 25GE-ports e810-XXVDA4-2p25GE: - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4. - ring4 200GE-ports ConnectX7-2p200GE: - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. - ring5 100GE-ports e810-2CQDA2-2p100GE: - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. ```