# FD.io CSIT Testbed Specifications 1. [Purpose](#purpose) 1. [Testbeds Overview](#testbeds-overview) 1. [Summary List](#summary-list) 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) 1. [Server Management](#server-management) 1. [Requirements](#requirements) 1. [Addressing](#addressing) 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses) 1. [Server Type Specification](#server-type-specification) 1. [Server and Port Naming](#server-and-port-naming) 1. [Testbeds Configuration](#testbeds-configuration) 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify) 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) 1. [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo) 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo) 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) 1. [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip) 1. [Inventory](#inventory) 1. [Appliances](#appliances) 1. [Arm Servers](#arm-servers) 1. [Xeon and Atom Servers](#xeon-and-atom-servers) 1. [Network Interface Cards](#network-interface-cards) 1. [Pluggables and Cables](#pluggables-and-cables) 1. [Other Parts](#other-parts) ## Purpose This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project. ## Testbeds Overview ### Summary List ``` #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 Totals: 17 26 14 12 19 1 2 1 1 2 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC ports connected back-to-back. Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC ports connected back-to-back. Used for FD.io VPP_Device functional driver tests. ### 2-Node-Skylake Xeon Intel (2n-skx) Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG (Type-B2 server) connected back-to-back. Used for FD.io performance tests. ### 2-Node-Denverton Atom Intel (2n-dnv) Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG (Type-B2 server) connected back-to-back. Used for FD.io performance tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back. Used for FD.io TCP/IP and HTTP performance tests. ### 3-Node-Haswell Xeon Intel (3n-hsw) Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one TG (Type-A2 server) connected in full-mesh triangle. Used for FD.io performance tests. ### 3-Node-Skylake Xeon Intel (3n-skx) Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one TG (Type-B2 server) connected in full-mesh triangle. Used for FD.io performance tests. ### 3-Node-TaiShan Arm Huawei (3n-tsh) Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG (Type-B2 server) connected in full-mesh triangle. Used for FD.io performance tests. ### 3-Node-MACCHIATObin Arm Marvell Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and one TG (Type-B2 server) connected in full-mesh triangle. Used for FD.io performance tests. ### 3-Node-Rangeley Atom Testbeds Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device) and one TG (Type-2 server) connected in full-mesh triangle. Used for FD.io performance tests. ## Server Management ### Requirements For management purposes, each server must have following two ports connected to the management network: ``` - 1GE IPMI port - IPMI - Intelligent Platform Management Interface. - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. - 1GE/10GE/40GE management port - hostOS management port for general system management. ``` ### Addressing Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. ``` 1. LOM (IPMI) VLAN: - Subnet: 10.30.50.0/24 - Gateway: 10.30.50.1 - Broadcast: 10.30.50.255 - DNS1: 199.204.44.24 - DNS2: 199.204.47.54 2. Management Vlan: - Subnet: 10.30.51.0/24 - Gateway: 10.30.51.1 - Broadcast: 10.30.51.255 - DNS1: 199.204.44.24 - DNS2: 199.204.47.54 ``` To access these hosts, VPN connection is required. ### LOM (IPMI) VLAN IP Addresses Name | Comment ------------ | ------- 10.30.50.0 | network 10.30.51.1 | Router 10.30.50.2 | LF Reserved 10.30.50.3 | LF Reserved 10.30.50.4 | LF Reserved 10.30.50.5 | LF Reserved 10.30.50.6 | LF Reserved 10.30.50.7 | LF Reserved 10.30.50.8 | LF Reserved 10.30.50.9 | LF Reserved 10.30.50.10 | LF Reserved 10.30.50.11 | LF Reserved 10.30.50.12 | LF Reserved 10.30.50.13 | LF Reserved 10.30.50.14 | LF Reserved 10.30.50.15 | LF Reserved 10.30.50.16 | t1-tg1 10.30.50.17 | t1-sut1 10.30.50.18 | t1-sut2 10.30.50.20 | t2-tg1 10.30.50.21 | t2-sut1 10.30.50.22 | t2-sut2 10.30.50.24 | t3-tg1 10.30.50.25 | t3-sut1 10.30.50.26 | t3-sut-2 10.30.50.28 | t4-sut1 10.30.50.29 | t4-sut2 10.30.50.30 | t4-sut3 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 10.30.50.41 | s3-t21-sut1 10.30.50.42 | s4-t21-tg1 10.30.50.43 | s11-t31-sut1 10.30.50.44 | s12-t31-sut2 10.30.50.45 | s13-t31-tg1 10.30.50.46 | s19-t33t34-tg1 10.30.50.47 | s1-t11-sut1 10.30.50.48 | s2-t12-sut1 10.30.50.49 | s5-t22-sut1 10.30.50.50 | s6-t22-tg1 10.30.50.51 | s7-t23-sut1 10.30.50.52 | s8-t23-tg1 10.30.50.53 | s9-t24-sut1 10.30.50.54 | s10-t24-tg1 10.30.50.55 | s14-t32-sut1 10.30.50.56 | s15-t32-sut2 10.30.50.57 | s16-t32-tg1 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 10.30.50.69 | s27-t13-sut 10.30.50.255 | Broadcast ### Management VLAN IP Addresses Name | Comment ------------------------- | ------- 10.30.51.0 | network 10.30.51.1 | Router 10.30.51.2 | LF Reserved 10.30.51.3 | LF Reserved 10.30.51.4 | LF Reserved 10.30.51.5 | LF Reserved 10.30.51.6 | LF Reserved 10.30.51.7 | LF Reserved 10.30.51.8 | LF Reserved 10.30.51.9 | s22-t35-sut1 (netgate-1) 10.30.51.10 | s23-t35-sut2 (netgate-2) 10.30.51.11 | s24-t35-sut3 (netgate-3) 10.30.51.12 | softiron-1 10.30.51.13 | softiron-2 10.30.51.14 | softiron-3 10.30.51.15 | LF Reserved 10.30.51.16 | t1-tg1 10.30.51.17 | t1-sut1 10.30.51.18 | t1-sut2 10.30.51.20 | t2-tg1 10.30.51.21 | t2-sut1 10.30.51.22 | t2-sut2 10.30.51.24 | t3-tg1 10.30.51.25 | t3-sut1 10.30.51.26 | t3-sut-2 10.30.51.28 | t4-sut1 10.30.51.29 | t4-sut2 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED 10.30.51.30 | t4-sut3 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED 10.30.51.36 | s17-t33-sut1 10.30.51.37 | s18-t33-sut2 10.30.51.41 | s20-t34-sut1 10.30.51.42 | s21-t34-sut2 10.30.51.44 | s3-t21-sut1 10.30.51.45 | s4-t21-tg1 10.30.51.46 | s11-t31-sut1 10.30.51.47 | s12-t31-sut2 10.30.51.48 | s13-t31-tg1 10.30.51.49 | s19-t33t34-tg1 10.30.51.50 | s1-t11-sut1 10.30.51.51 | s2-t12-sut1 10.30.51.52 | s5-t22-sut1 10.30.51.53 | s6-t22-tg1 10.30.51.54 | s7-t23-sut1 10.30.51.55 | s8-t23-tg1 10.30.51.56 | s9-t24-sut1 10.30.51.57 | s10-t24-tg1 10.30.51.58 | s14-t32-sut1 10.30.51.59 | s15-t32-sut2 10.30.51.60 | s16-t32-tg1 10.30.51.61 | s25-t25-sut1 10.30.51.62 | s26-t25-tg1 10.30.51.69 | s27-t13-sut1 10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED 10.30.51.106-10.30.51.180 | VIRL2 10.30.51.181-10.30.51.254 | VIRL3 10.30.51.255 | Broadcast ## Server Type Specification FD.io CSIT lab contains following server types: ``` 1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. - Quantity: 6 servers. - Physical connectivity: - CIMC and host management ports. - NIC ports connected in 3-node topologies. - Main HW configuration: - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. - Processors: 2* E5-2699v3 2.3 GHz. - RAM Memory: 16* 32GB DDR4-2133MHz. - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) - PCIe Slot1: Cisco VIC 1385 2p40GE. - PCIe Slot2: Intel NIC x520 2p10GE. - PCIe Slot3: empty. - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) - PCIe Slot4: Intel NIC xl710 2p40GE. - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). 2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. - NIC ports connected in 3-node topologies. - Main HW configuration: - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. - Processors: 2* E5-2699v3 2.3 GHz. - RAM Memory: 16* 32GB DDR4-2133MHz. - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) - PCIe Slot1: Intel NIC xl710 2p40GE. - PCIe Slot2: Intel NIC x710 2p10GE. - PCIe Slot3: Intel NIC x710 2p10GE. - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - PCIe Slot4: Intel NIC xl710 2p40GE. - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel NIC x710 2p10GE. - MLOM slot: empty. 3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. - no NIC ports, standalone setup. - Main HW configuration: - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots. - Processors: 2* E5-2699v3 2.3 GHz. - RAM Memory: 16* 32GB DDR4-2133MHz. - Disks: 2* 480 GB 2.5inch 6G SATA SSD. - NICs configuration: - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) - no cards. - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - no cards. - MLOM slot: empty. 4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and 3-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.3 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and 3-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.3 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. 3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. - NIC ports connected into 3-node topology. - Main HW configuration: - Chassis: Huawei TaiShan 2280. - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 - RAM Memory: 8* 16GB DDR4-2400MT/s - Disks: 1* 4TB SATA HDD - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: 82599-2p10GE Intel. 4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - Host management ports. - NIC ports connected into 2-node and 3-node topologies. - Main HW configuration: - Chassis: MACCHIATObin. - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72 - RAM Memory: 1* 16GB DDR4 - Disks: 1* 128GB(?) SATA SDD - NICs configuration: - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) 5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console - NIC ports connected into 2-node. - Main HW configuration: - Chassis: Netgate XG-2758-1u - Processors: 1* Rangeley (Atom) C2758 2.4 GHz - RAM Memory: 16GB ECC - Disks: 150 GB - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and 3-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.3 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. - 8-port 10GE SFP+ integrated NIC. - Main HW configuration: - Chassis: PS10GE4NG. - Motherboard: SuperMicro X11DPG-QT. - Processors: Quad-Core, Intel Processor. - HW accelerators: FPGA offload. - RAM Memory: 64GB. - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - Physical Interfaces: 4 * 10GE SFP+. - Operating System: Native IxOS. - Interface configuration: - Port-1: 10GE SFP+. - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. 8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.3 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: empty. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: Gigabyte R181-T90 1U - Motheboard: MT91-FS1 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - PCIe Slot1 05:00.xx: XL710-QDA2. - PCIe Slot3 08:00.xx: XL710-QDA2. - Numa1: - PCIe Slot6 85:00.xx: XL710-QDA2. 10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. - NIC ports. - Main HW configuration: - Chassis: SuperMicro SYS-E300-9A - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz - RAM Memory: 32GB ECC - Disks: 480 GB - NICs configuration: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports ``` ### Server and Port Naming Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: ``` - testbedname: testbedN. - hostname: - traffic-generator: tN-tgW. - system-under-testX: tN-sutX. - portnames: - tN-tgW-cY/pZ. - tN-sutX-cY/pZ. - where: - N - testbed number. - tgW - server acts as traffic-generator with W index. - sutX - server acts as system-under-test with X index. - Y - PCIe slot number denoting a NIC card number within the host. - Z - port number on the NIC card. ``` ## Testbeds Configuration ### Per Testbed Server Allocation and Naming #### 1-Node-Skylake (1n-skx) PROD ``` - ServerB1 [Type-B6]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 - Host IP: 10.30.51.50 - portnames: - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. - ServerB2 [Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 - Host IP: 10.30.51.51 - portnames: - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` #### 1-Node-Thunderx2 (1n-tx2) WIP ``` - ServerB17 [Type-B9]: - testbedname: testbed13. - hostname: s27-t13-sut1. - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. ``` #### 2-Node-Skylake (2n-skx) PROD ``` - ServerB3 [Type-B1]: - testbedname: testbed21. - hostname: s3-t21-sut1. - IPMI IP: 10.30.50.41 - Host IP: 10.30.51.44 - portnames: - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB4 [Type-B2]: - testbedname: testbed21. - hostname: s4-t21-tg1. - IPMI IP: 10.30.50.42 - Host IP: 10.30.51.45 - portnames: - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB5 [Type-B1]: - testbedname: testbed22. - hostname: s5-t22-sut1. - IPMI IP: 10.30.50.49 - Host IP: 10.30.51.52 - portnames: - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB6 [Type-B2]: - testbedname: testbed22. - hostname: s6-t22-tg1. - IPMI IP: 10.30.50.50 - Host IP: 10.30.51.53 - portnames: - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB7 [Type-B1]: - testbedname: testbed23. - hostname: s7-t23-sut1. - IPMI IP: 10.30.50.51 - Host IP: 10.30.51.54 - portnames: - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB8 [Type-B2]: - testbedname: testbed23. - hostname: s8-t23-tg1. - IPMI IP: 10.30.50.52 - Host IP: 10.30.51.55 - portnames: - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB9 [Type-B1]: - testbedname: testbed24. - hostname: s9-t24-sut1. - IPMI IP: 10.30.50.53 - Host IP: 10.30.51.56 - portnames: - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB10 [Type-B2]: - testbedname: testbed24. - hostname: s10-t24-tg1. - IPMI IP: 10.30.50.54 - Host IP: 10.30.51.57 - portnames: - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` #### 2-Node-Denverton (2n-dnv) TODO ``` To be completed. ``` #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY ``` - ServerB25 [Type-B8]: - testbedname: testbed25. - hostname: s25-t25-sut1. - IPMI IP: 10.30.50.58 - Host IP: 10.30.51.61 - portnames: - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - ServerB26 [Type-B7]: - testbedname: testbed25. - hostname: s26-t25-tg1. - IPMI IP: 10.30.50.59 - Host IP: 10.30.51.62 - portnames: - s26-t25-tg1-p1 - 10GE-port1. - s26-t25-tg1-p2 - 10GE-port2. - s26-t25-tg1-p3 - 10GE-port3. - s26-t25-tg1-p4 - 10GE-port4. ``` #### 3-Node-Haswell (3n-hsw) PROD ``` 1. Server1 of Type-1: - testbedname: testbed1. - hostname: t1-sut1. - CIMC IP: 10.30.50.17 - Host IP: 10.30.51.17 - portnames: - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 2. Server2 of Type-1: - testbedname: testbed1. - hostname: t1-sut2. - CIMC IP: 10.30.50.18 - Host IP: 10.30.51.18 - portnames: - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 3. Server3 of Type-2: - testbedname: testbed1. - hostname: t1-tg1. - CIMC IP: 10.30.50.16 - Host IP: 10.30.51.16 - portnames: - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. 4. Server4 of Type-1: - testbedname: testbed2. - hostname: t2-sut1. - CIMC IP: 10.30.50.21 - Host IP: 10.30.51.21 - portnames: - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 5. Server5 of Type-1: - testbedname: testbed2. - hostname: t2-sut2. - CIMC IP: 10.30.50.22 - Host IP: 10.30.51.22 - portnames: - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 6. Server6 of Type-2: - testbedname: testbed2. - hostname: t2-tg1. - CIMC IP: 10.30.50.20 - Host IP: 10.30.51.20 - portnames: - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. 7. Server7 of Type-1: - testbedname: testbed3. - hostname: t3-sut1. - CIMC IP: 10.30.50.25 - Host IP: 10.30.51.25 - portnames: - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 8. Server8 of Type-1: - testbedname: testbed3. - hostname: t3-sut2. - CIMC IP: 10.30.50.26 - Host IP: 10.30.51.26 - portnames: - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. 9. Server9 of Type-2: - testbedname: testbed3. - hostname: t3-tg1. - CIMC IP: 10.30.50.24 - Host IP: 10.30.51.24 - portnames: - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. ``` #### 3-Node-Skylake (3n-skx) PROD ``` - ServerB11 [Type-B1]: - testbedname: testbed31. - hostname: s11-t31-sut1. - IPMI IP: 10.30.50.43 - Host IP: 10.30.51.46 - portnames: - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB12 [Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. - IPMI IP: 10.30.50.44 - Host IP: 10.30.51.47 - portnames: - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE. - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE. - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE. - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB13 [Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. - IPMI IP: 10.30.50.45 - Host IP: 10.30.51.48 - portnames: - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB14 [Type-B1]: - testbedname: testbed32. - hostname: s14-t32-sut1. - IPMI IP: 10.30.50.55 - Host IP: 10.30.51.58 - portnames: - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB15 [Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. - IPMI IP: 10.30.50.56 - Host IP: 10.30.51.59 - portnames: - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE. - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE. - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE. - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB16 [Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. - IPMI IP: 10.30.50.57 - Host IP: 10.30.51.60 - portnames: - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` Note: ServerB19 (TG) is shared between testbed33 & testbed34 #### 3-Node-Rangeley (3n-rng) VERIFY Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` - ServerB22 [Type-B5]: - testbedname: testbed35. - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 - Host IP: 10.30.51.9 - portnames: - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) - ServerB23 [Type-B5]: - testbedname: testbed35. - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 - Host IP: 10.30.51.10 - portnames: - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) - ServerB24 [Type-B5]: - testbedname: testbed35. - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 - Host IP: 10.30.51.11 - portnames: - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) ``` #### 3-Node-Taishan (3n-tsh) WIP ``` - ServerB17 [Type-B3]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 - Host IP: 10.30.51.36 - portnames: - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE. - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. - ServerB18 [Type-B3]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 - Host IP: 10.30.51.37 - portnames: - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE. - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. - ServerB19 [Type-B2]: - testbednames: testbed33 and testbed34. - hostname: s19-t33t34-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. - ServerB20 [Type-B4]: - testbedname: testbed34. - hostname: s20-t34-sut1. - IPMI IP: N/A - Host IP: 10.30.51.41 - portnames: - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. - ServerB21 [Type-B4]: - testbedname: testbed34. - hostname: s21-t34-sut2. - IPMI IP: N/A - Host IP: 10.30.51.42 - portnames: - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell. - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. ``` #### 3-Node-Mcbin (3n-mcb) TODO ``` To be completed. ``` ### Per Testbed Wiring #### 1-Node-Skylake (1n-skx) PROD ``` - testbed11: - ring1 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. - ring2 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. - ring3 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - testbed12: - ring1 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. - ring2 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. - ring3 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. ``` #### 1-Node-Thunderx2 (1n-tx2) WIP ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1. - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs: - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. ``` #### 2-Node-Skylake (2n-skx) PROD ``` - testbed21: - ring1 10GE-ports x710-4p10GE on SUT: - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1. - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3. - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. - testbed22: - ring1 10GE-ports x710-4p10GE on SUT: - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3. - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. - testbed23: - ring1 10GE-ports x710-4p10GE on SUT: - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3. - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. - testbed24: - ring1 10GE-ports x710-4p10GE on SUT: - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3. - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` #### 2-Node-Denverton (2n-dnv) TODO ``` To be completed. ``` #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY ``` - testbed25: - link1 10GE-port x710-4p10GE on SUT: - t25-tg1-p1 to t25-sut1-c2/p1. - link2 10GE-port x710-4p10GE on SUT: - t25-tg1-p2 to t25-sut1-c2/p2. - link3 10GE-port x710-4p10GE on SUT: - t25-tg1-p3 to t25-sut1-c2/p3. - link4 10GE-port x710-4p10GE on SUT: - t25-tg1-p4 to t25-sut1-c2/p4. ``` #### 3-Node-Haswell (3n-hsw) PROD ``` 1. testbed1: - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - t1-tg1-c1/p1 to t1-sut1-c1/p2. - t1-sut1-c1/p1 to t1-sut2-c1/p2. - t1-sut2-c1/p1 to t1-tg1-c1/p2. - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - t1-tg1-c2/p1 to t1-sut1-c2/p2. - t1-sut1-c2/p1 to t1-sut2-c2/p2. - t1-sut2-c2/p1 to t1-tg1-c2/p2. - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - t1-tg1-c4/p1 to t1-sut1-c4/p2. - t1-sut1-c4/p1 to t1-sut2-c4/p2. - t1-sut2-c4/p1 to t1-tg1-c4/p2. - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - t1-tg1-c5/p1 to t1-sut1-c5/p2. - t1-sut1-c5/p1 to t1-sut2-c5/p2. - t1-sut2-c5/p1 to t1-tg1-c5/p2. - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - t1-tg1-c2/p1 to t1-sut1-cm/p2. - t1-sut1-cm/p1 to t1-sut2-cm/p2. - t1-sut2-cm/p1 to t1-tg1-c2/p2. - TG loopback ports Intel NIC x710 2p10GE - t1-tg1-c6/p1 to t1-tg1-c6/p2. 2. testbed2: - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - t2-tg1-c1/p1 to t2-sut1-c1/p2. - t2-sut1-c1/p1 to t2-sut2-c1/p2. - t2-sut2-c1/p1 to t2-tg1-c1/p2. - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - t2-tg1-c2/p1 to t2-sut1-c2/p2. - t2-sut1-c2/p1 to t2-sut2-c2/p2. - t2-sut2-c2/p1 to t2-tg1-c2/p2. - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - t2-tg1-c4/p1 to t2-sut1-c4/p2. - t2-sut1-c4/p1 to t2-sut2-c4/p2. - t2-sut2-c4/p1 to t2-tg1-c4/p2. - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - t2-tg1-c5/p1 to t2-sut1-c5/p2. - t2-sut1-c5/p1 to t2-sut2-c5/p2. - t2-sut2-c5/p1 to t2-tg1-c5/p2. - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - t2-tg1-c2/p1 to t2-sut1-cm/p2. - t2-sut1-cm/p1 to t2-sut2-cm/p2. - t2-sut2-cm/p1 to t2-tg1-c2/p2. - TG loopback ports Intel NIC x710 2p10GE - t2-tg1-c6/p1 to t2-tg1-c6/p2. 3. testbed3: - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - t3-tg1-c1/p1 to t3-sut1-c1/p2. - t3-sut1-c1/p1 to t3-sut2-c1/p2. - t3-sut2-c1/p1 to t3-tg1-c1/p2. - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - t3-tg1-c2/p1 to t3-sut1-c2/p2. - t3-sut1-c2/p1 to t3-sut2-c2/p2. - t3-sut2-c2/p1 to t3-tg1-c2/p2. - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - t3-tg1-c4/p1 to t3-sut1-c4/p2. - t3-sut1-c4/p1 to t3-sut2-c4/p2. - t3-sut2-c4/p1 to t3-tg1-c4/p2. - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - t3-tg1-c5/p1 to t3-sut1-c5/p2. - t3-sut1-c5/p1 to t3-sut2-c5/p2. - t3-sut2-c5/p1 to t3-tg1-c5/p2. - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - t3-tg1-c2/p1 to t3-sut1-cm/p2. - t3-sut1-cm/p1 to t3-sut2-cm/p2. - t3-sut2-cm/p1 to t3-tg1-c2/p2. - TG loopback ports Intel NIC x710 2p10GE - t3-tg1-c6/p1 to t3-tg1-c6/p2. ``` #### 3-Node-Skylake (3n-skx) PROD ``` - testbed31: - ring1 10GE-ports x710-4p10GE on SUTs: - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1. - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2. - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3. - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4. - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1. - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2. - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1. - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2. - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2. - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4. - testbed32: - ring1 10GE-ports x710-4p10GE on SUTs: - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1. - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2. - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2. - ring2 10GE-ports x710-4p10GE on SUT: - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3. - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4. - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1. - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2. - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2. - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1. - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2. - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2. - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2. - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. ``` #### 3-Node-Rangeley (3n-rng) TODO ``` To be completed. ``` #### 3-Node-Taishan (3n-tsh) WIP ``` - testbed33: - ring1 10GE-ports 82599-2p10GE on SUTs: - t33t34-tg1-c2/p2 - t33-sut1-c6/p2. - t33-sut1-c6/p1 - t33-sut2-c6/p2. - t33-sut2-c6/p1 - t33t34-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - t33t34-tg1-c4/p2 - t33-sut1-c4/p2. - t33-sut1-c4/p1 - t33-sut2-c4/p2. - t33-sut2-c4/p1 - t33t34-tg1-c4/p1. ``` #### 3-Node-Mcbin (3n-mcb) WIP ``` - testbed34: - ring1 10GE-ports Marvell on SUTs: - t33t34-tg1-c2/p3 - t34-sut1-ca/p1. - t34-sut1-ca/p2 - t34-sut2-ca/p1. - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. ``` ## Inventory ### Appliances ``` 1. Ixia PerfectStorm One Appliance - 1 * PS10GE4NG - Chassis: PS10GE4NG. - Motherboard: SuperMicro X11DPG-QT. - Processors: Quad-Core, Intel Processor. - HW accelerators: FPGA offload. - RAM Memory: 64GB. - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - Physical Interfaces: 4 * 10GE SFP+. - Operating System: Native IxOS. ``` ### Arm Servers ``` 1. Arm Cortex A-72 servers - 1 * ThunderX2 - Chassis: Marvell ThunderX2 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2. - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - 2 * Huawei TaiShan 2280. - Chassis: Huawei TaiShan 2280. - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. - 3 * MACCHIATObin - Chassis: MACCHIATObin. - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72. - RAM Memory: 1* 16GB DDR4. - Disks: 1* 128GB(?) SATA SDD. ``` ### Xeon and Atom Servers ``` 1. Intel Xeon servers: - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - Processors: 2* Intel Platinum 8180 2.3 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. 2. Intel Atom servers with Rangely processors. - 3 * Netgate XG-2758-1u - Chassis: Netgate XG-2758-1u - Processors: 1* Rangely (Atom) C2758 2.4 GHz - RAM Memory: 16GB ECC - Disks: 150 GB ``` ### Network Interface Cards ``` 1. 10GE NICs - 14 * Intel® Ethernet Converged Network Adapter X710-DA4 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2 2. 25GE NICs - 12 * Intel® Ethernet Network Adapter XXV710-DA2 3. 40GE NICs - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2 4. 100GE NICs - 4 * mcx556a-edat NICs (not on site yet, in transit) ``` ### Pluggables and Cables Pluggables: ``` 1. 10GE SFP+ - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics - 80 * 10G SR optic (generic, "Intel" compatible branded) 2. 25GE SFP28 - None 3. 40GE QSFP+ - None 4. 100GE - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit) ``` Standalone cables: ``` 1. 10GE - None 2. 25GE - None 3. 40GE QSFP+ - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable 4. 100GE - None ``` ### Other Parts None.