diff options
author | Juraj Linkeš <juraj.linkes@pantheon.tech> | 2022-03-14 14:46:47 +0100 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2022-06-30 09:01:47 +0000 |
commit | 547ab281e31b796d1e69cd455b4e830892773dce (patch) | |
tree | aa60f4eedf7580031ac3151934a1d5e4e663db0d | |
parent | 082a4e57bc6b722567d4890efa62000b661bf6a0 (diff) |
lab: update 3n-alt docs
Change-Id: I6c77f633bfcae3b342d211a6b6379acb2f1adb6a
Signed-off-by: Juraj Linkeš <juraj.linkes@pantheon.tech>
(cherry picked from commit 7b06cddf4f0ceca580b71b695e34a39e706931fc)
-rw-r--r-- | docs/lab/fdio-dc-physical.yaml | 78 | ||||
-rw-r--r-- | docs/lab/testbed_specifications.md | 119 |
2 files changed, 101 insertions, 96 deletions
diff --git a/docs/lab/fdio-dc-physical.yaml b/docs/lab/fdio-dc-physical.yaml index 98a0332bbd..9747c24f74 100644 --- a/docs/lab/fdio-dc-physical.yaml +++ b/docs/lab/fdio-dc-physical.yaml @@ -383,6 +383,34 @@ yul1: serial_number: C7470KL03P50454 mgmt_ip4: 10.30.51.80 lom_ip4: 10.30.50.80 + - unit: 21..22 + name: s52-nomad + oper_status: production + device_type: ThunderX-88XX + serial_number: N/A + mgmt_ip4: 10.30.51.65 + lom_ip4: 10.30.50.65 + - unit: 21..22 + name: s51-nomad + oper_status: production + device_type: ThunderX-88XX + serial_number: N/A + mgmt_ip4: 10.30.51.66 + lom_ip4: 10.30.50.66 + - unit: 21..22 + name: s49-nomad + oper_status: production + device_type: ThunderX-88XX + serial_number: N/A + mgmt_ip4: 10.30.51.67 + lom_ip4: 10.30.50.67 + - unit: 21..22 + name: s50-nomad + oper_status: production + device_type: ThunderX-88XX + serial_number: N/A + mgmt_ip4: 10.30.51.68 + lom_ip4: 10.30.50.68 - unit: 19..20 name: s42-nomad oper_status: production @@ -419,52 +447,24 @@ yul1: mgmt_ip4: 10.30.51.70 lom_ip4: 10.30.50.70 - unit: 9..10 - name: s52-nomad - oper_status: production - device_type: ThunderX-88XX - serial_number: N/A - mgmt_ip4: 10.30.51.65 - lom_ip4: 10.30.50.65 - - unit: 9..10 - name: s52-nomad - oper_status: production - device_type: ThunderX-88XX - serial_number: N/A - mgmt_ip4: 10.30.51.66 - lom_ip4: 10.30.50.66 - - unit: 9..10 - name: s52-nomad - oper_status: production - device_type: ThunderX-88XX - serial_number: N/A - mgmt_ip4: 10.30.51.67 - lom_ip4: 10.30.50.67 - - unit: 9..10 - name: s52-nomad - oper_status: production - device_type: ThunderX-88XX - serial_number: N/A - mgmt_ip4: 10.30.51.68 - lom_ip4: 10.30.50.68 - - unit: 7..8 name: s62-t34-sut1 - oper_status: in-transit - device_type: Ampere-TBD - serial_number: TBD + oper_status: production + device_type: Mt.Jade Server System B81.030Z1.0007 + serial_number: 04000059N0SC mgmt_ip4: 10.30.51.72 lom_ip4: 10.30.50.72 - - unit: 5..6 + - unit: 7..8 name: s63-t34-sut2 - oper_status: in-transit - device_type: Ampere-TBD - serial_number: TBD + oper_status: production + device_type: Mt.Jade Server System B81.030Z1.0007 + serial_number: 0390003EN0SC mgmt_ip4: 10.30.51.73 lom_ip4: 10.30.50.73 - - unit: 1..4 + - unit: 3..6 name: s64-t34-tg1 - oper_status: in-transit - device_type: Intel-TBD - serial_number: TBD + oper_status: production + device_type: SYS-740GP-TNRT + serial_number: C7470KK40P50249 mgmt_ip4: 10.30.51.74 lom_ip4: 10.30.50.74 rack: diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 196c956dea..9306177011 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -95,12 +95,12 @@ hosted by LFN FD.io CSIT project. 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0 -15. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5 0 +15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0 16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2 - Totals: 34 44 21 4 17 1 2 3 3 2 4 7 2 15 2 + Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -321,7 +321,7 @@ Name | Comment 10.30.50.71 | s56-t14-sut1 10.30.50.72 | s62-t34-sut1 10.30.50.73 | s63-t34-sut2 -10.30.50.74 | s64-t34t36-tg1 +10.30.50.74 | s64-t34-tg1 10.30.50.75 | s65-t37-sut1 10.30.50.76 | s66-t37-sut2 10.30.50.77 | s67-t37-tg1 @@ -417,7 +417,7 @@ Name | Comment 10.30.51.71 | s56-t14-sut1 10.30.51.72 | s62-t34-sut1 10.30.51.73 | s63-t34-sut2 -10.30.51.74 | s64-t34t36-tg1 +10.30.51.74 | s64-t34-tg1 10.30.51.75 | s65-t37-sut1 10.30.51.76 | s66-t37-sut2 10.30.51.77 | s67-t37-tg1 @@ -797,28 +797,38 @@ FD.io CSIT lab contains following server types: - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. + - no cards - Numa1: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - - Quantity: 1 + - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node topologies. - Main HW configuration: - - Chassis: TBD - - Motherboard: TBD - - Processors: n* TBD - - RAM Memory: n* TBD - - Disks: TBD + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Motherboard: Mt.Jade Motherboard + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - NICs configuration: - Numa0: - - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - Numa1: - - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + - no cards. +21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 +22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -838,7 +848,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. +23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 8. - Physical connectivity: - IPMI and host management ports. @@ -858,7 +868,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. +24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -878,7 +888,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. +25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -898,7 +908,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -918,16 +928,6 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. -26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: Gigabyte R152-P30-00 1U - - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1) - - RAM Memory: 4* 16GB RDIMM-3200MHz - - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: @@ -1380,8 +1380,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. - TG [Server-Type-E31]: @@ -1695,8 +1693,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 #### 3-Node-Altra Servers (3n-alt) PROD -Note: Server64 (TG) is shared between testbed34 & testbed36 - ``` - SUT [Server-Type-E23]: - testbedname: testbed34. @@ -1704,28 +1700,32 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - IPMI IP: 10.30.50.72 - Host IP: 10.30.51.72 - portnames: - - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE. + - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. - IPMI IP: 10.30.50.73 - Host IP: 10.30.51.73 - portnames: - - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE. + - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - TG [Server-Type-F4]: - testbedname: testbed34. - - hostname: s64-t34t36-tg1. + - hostname: s64-t34-tg1. - IPMI IP: 10.30.50.74 - Host IP: 10.30.51.74 - portnames: - - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` #### 3-Node-Denverton Servers (3n-dnv) PROD @@ -2232,13 +2232,9 @@ To be completed. ``` - testbed34: - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: - - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2. - - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2. - - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1. - - ring2 100GE-ports ConnectX5-2p100GE on SUTs: - - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2. - - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2. - - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1. + - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. + - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. + - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. ``` #### 3-Node-Denverton Wiring (3n-dnv) PROD @@ -2338,11 +2334,20 @@ To be completed. - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. - - 2 * Ampere Altra - - Chassis: TBD - - Processors: TBD - - RAM Memory: TBD - - Disks: TBD +2. Arm Neoverse N1 servers + - 2 * Ampere Altra (Performance) + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 + - 2 * Ampere Altra (Build) + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 ``` ### Xeon and Atom Servers |