space:
mode:
authorChristian Ehrhardt <christian.ehrhardt@canonical.com>2018-06-01 09:09:08 +0200
committerChristian Ehrhardt <christian.ehrhardt@canonical.com>2018-06-01 09:12:07 +0200
commit1bd9b61222f3a81ffe770fc00b70ded6e760c42b (patch)
tree0bf7d996cf0664796687c1be6d22958fcf6a8096 /doc/guides/nics/enic.rst
parentbb4e158029645f37809fcf81a3acddd6fa11f88a (diff)
New upstream version 18.05
Change-Id: Icd4170ddc4f63aeae5d0559490e5195b5349f9c2 Signed-off-by: Christian Ehrhardt <christian.ehrhardt@canonical.com>
Diffstat (limited to 'doc/guides/nics/enic.rst')
-rw-r--r--doc/guides/nics/enic.rst156
1 files changed, 127 insertions, 29 deletions
diff --git a/doc/guides/nics/enic.rst b/doc/guides/nics/enic.rst
index 4dffce1a..d650ba0f 100644
--- a/doc/guides/nics/enic.rst
+++ b/doc/guides/nics/enic.rst
@@ -114,11 +114,24 @@ Configuration information
- **Interrupts**
- Only one interrupt per vNIC interface should be configured in the UCS
+ At least one interrupt per vNIC interface should be configured in the UCS
manager regardless of the number receive/transmit queues. The ENIC PMD
uses this interrupt to get information about link status and errors
in the fast path.
+ In addition to the interrupt for link status and errors, when using Rx queue
+ interrupts, increase the number of configured interrupts so that there is at
+ least one interrupt for each Rx queue. For example, if the app uses 3 Rx
+ queues and wants to use per-queue interrupts, configure 4 (3 + 1) interrupts.
+
+ - **Receive Side Scaling**
+
+ In order to fully utilize RSS in DPDK, enable all RSS related settings in
+ CIMC or UCSM. These include the following items listed under
+ Receive Side Scaling:
+ TCP, IPv4, TCP-IPv4, IPv6, TCP-IPv6, IPv6 Extension, TCP-IPv6 Extension.
+
+
.. _enic-flow-director:
Flow director support
@@ -140,20 +153,21 @@ perfect filtering of the 5-tuple with no masking of fields supported.
SR-IOV mode utilization
-----------------------
-UCS blade servers configured with dynamic vNIC connection policies in UCS
-manager are capable of supporting assigned devices on virtual machines (VMs)
-through a KVM hypervisor. Assigned devices, also known as 'passthrough'
-devices, are SR-IOV virtual functions (VFs) on the host which are exposed
-to VM instances.
+UCS blade servers configured with dynamic vNIC connection policies in UCSM
+are capable of supporting SR-IOV. SR-IOV virtual functions (VFs) are
+specialized vNICs, distinct from regular Ethernet vNICs. These VFs can be
+directly assigned to virtual machines (VMs) as 'passthrough' devices.
-The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
+In UCS, SR-IOV VFs require the use of the Cisco Virtual Machine Fabric Extender
+(VM-FEX), which gives the VM a dedicated
interface on the Fabric Interconnect (FI). Layer 2 switching is done at
the FI. This may eliminate the requirement for software switching on the
host to route intra-host VM traffic.
Please refer to `Creating a Dynamic vNIC Connection Policy
<http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
-for information on configuring SR-IOV adapter policies using UCS manager.
+for information on configuring SR-IOV adapter policies and port profiles
+using UCSM.
Once the policies are in place and the host OS is rebooted, VFs should be
visible on the host, E.g.:
@@ -170,30 +184,37 @@ visible on the host, E.g.:
0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
-Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
-be created with an assigned device. When using libvirt, this configuration can
-be done within the domain (i.e. VM) config file. For example this entry maps
-host VF 0d:00:01 into the VM.
+Enable Intel IOMMU on the host and install KVM and libvirt, and reboot again as
+required. Then, using libvirt, create a VM instance with an assigned device.
+Below is an example ``interface`` block (part of the domain configuration XML)
+that adds the host VF 0d:00:01 to the VM. ``profileid='pp-vlan-25'`` indicates
+the port profile that has been configured in UCSM.
.. code-block:: console
<interface type='hostdev' managed='yes'>
<mac address='52:54:00:ac:ff:b6'/>
+ <driver name='vfio'/>
<source>
<address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
</source>
+ <virtualport type='802.1Qbh'>
+ <parameters profileid='pp-vlan-25'/>
+ </virtualport>
+ </interface>
+
Alternatively, the configuration can be done in a separate file using the
``network`` keyword. These methods are described in the libvirt documentation for
`Network XML format <https://libvirt.org/formatnetwork.html>`_.
-When the VM instance is started, the ENIC KVM driver will bind the host VF to
+When the VM instance is started, libvirt will bind the host VF to
vfio, complete provisioning on the FI and bring up the link.
.. note::
It is not possible to use a VF directly from the host because it is not
- fully provisioned until the hypervisor brings up the VM that it is assigned
+ fully provisioned until libvirt brings up the VM that it is assigned
to.
In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
@@ -207,9 +228,27 @@ seen on the VM instance and should be available for binding to a DPDK.
Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
or ``vfio`` in non-IOMMU mode.
+In the VM, the kernel enic driver may be automatically bound to the VF during
+boot. Unbinding it currently hangs due to a known issue with the driver. To
+work around the issue, blacklist the enic module as follows.
Please see :ref:`Limitations <enic_limitations>` for limitations in
the use of SR-IOV.
+.. code-block:: console
+
+ # cat /etc/modprobe.d/enic.conf
+ blacklist enic
+
+ # dracut --force
+
+.. note::
+
+ Passthrough does not require SR-IOV. If VM-FEX is not desired, the user
+ may create as many regular vNICs as necessary and assign them to VMs as
+ passthrough devices. Since these vNICs are not SR-IOV VFs, using them as
+ passthrough devices do not require libvirt, port profiles, and VM-FEX.
+
+
.. _enic-genic-flow-api:
Generic Flow API support
@@ -227,7 +266,7 @@ Generic Flow API is supported. The baseline support is:
- Actions: queue and void
- Selectors: 'is'
-- **1300 series VICS with advanced filters disabled**
+- **1300 and later series VICS with advanced filters disabled**
With advanced filters disabled, an IPv4 or IPv6 item must be specified
in the pattern.
@@ -238,17 +277,65 @@ Generic Flow API is supported. The baseline support is:
- Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
- In total, up to 64 bytes of mask is allowed across all headers
-- **1300 series VICS with advanced filters enabled**
+- **1300 and later series VICS with advanced filters enabled**
- Attributes: ingress
- Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
- - Actions: queue, mark, flag and void
+ - Actions: queue, mark, drop, flag and void
- Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
- In total, up to 64 bytes of mask is allowed across all headers
More features may be added in future firmware and new versions of the VIC.
Please refer to the release notes.
+.. _overlay_offload:
+
+Overlay Offload
+---------------
+
+Recent hardware models support overlay offload. When enabled, the NIC performs
+the following operations for VXLAN, NVGRE, and GENEVE packets. In all cases,
+inner and outer packets can be IPv4 or IPv6.
+
+- TSO for VXLAN and GENEVE packets.
+
+ Hardware supports NVGRE TSO, but DPDK currently has no NVGRE offload flags.
+
+- Tx checksum offloads.
+
+ The NIC fills in IPv4/UDP/TCP checksums for both inner and outer packets.
+
+- Rx checksum offloads.
+
+ The NIC validates IPv4/UDP/TCP checksums of both inner and outer packets.
+ Good checksum flags (e.g. ``PKT_RX_L4_CKSUM_GOOD``) indicate that the inner
+ packet has the correct checksum, and if applicable, the outer packet also
+ has the correct checksum. Bad checksum flags (e.g. ``PKT_RX_L4_CKSUM_BAD``)
+ indicate that the inner and/or outer packets have invalid checksum values.
+
+- Inner Rx packet type classification
+
+ PMD sets inner L3/L4 packet types (e.g. ``RTE_PTYPE_INNER_L4_TCP``), and
+ ``RTE_PTYPE_TUNNEL_GRENAT`` to indicate that the packet is tunneled.
+ PMD does not set L3/L4 packet types for outer packets.
+
+- Inner RSS
+
+ RSS hash calculation, therefore queue selection, is done on inner packets.
+
+In order to enable overlay offload, the 'Enable VXLAN' box should be checked
+via CIMC or UCSM followed by a reboot of the server. When PMD successfully
+enables overlay offload, it prints the following message on the console.
+
+.. code-block:: console
+
+ Overlay offload is enabled
+
+By default, PMD enables overlay offload if hardware supports it. To disable
+it, set ``devargs`` parameter ``disable-overlay=1``. For example::
+
+ -w 12:00.0,disable-overlay=1
+
.. _enic_limitations:
Limitations
@@ -305,6 +392,20 @@ Limitations
were added. Since there currently is no grouping or priority support,
'catch-all' filters should be added last.
+- **Statistics**
+
+ - ``rx_good_bytes`` (ibytes) always includes VLAN header (4B) and CRC bytes (4B).
+ This behavior applies to 1300 and older series VIC adapters.
+ - When the NIC drops a packet because the Rx queue has no free buffers,
+ ``rx_good_bytes`` still increments by 4B if the packet is not VLAN tagged or
+ VLAN stripping is disabled, or by 8B if the packet is VLAN tagged and stripping
+ is enabled. This behavior applies to 1300 and older series VIC adapters.
+
+- **RSS Hashing**
+
+ - Hardware enables and disables UDP and TCP RSS hashing together. The driver
+ cannot control UDP and TCP hashing individually.
+
How to build the suite
----------------------
@@ -322,17 +423,8 @@ Supported Cisco VIC adapters
ENIC PMD supports all recent generations of Cisco VIC adapters including:
-- VIC 1280
-- VIC 1240
-- VIC 1225
-- VIC 1285
-- VIC 1225T
-- VIC 1227
-- VIC 1227T
-- VIC 1380
-- VIC 1340
-- VIC 1385
-- VIC 1387
+- VIC 1200 series
+- VIC 1300 series
Supported Operating Systems
---------------------------
@@ -356,10 +448,16 @@ Supported features
- VLAN filtering (supported via UCSM/CIMC only)
- Execution of application by unprivileged system users
- IPV4, IPV6 and TCP RSS hashing
+- UDP RSS hashing (support for upcoming adapters)
- Scattered Rx
- MTU update
- SR-IOV on UCS managed servers connected to Fabric Interconnects
- Flow API
+- Overlay offload
+
+ - Rx/Tx checksum offloads for VXLAN, NVGRE, GENEVE
+ - TSO for VXLAN and GENEVE packets
+ - Inner RSS
Known bugs and unsupported features in this release
---------------------------------------------------
@@ -369,8 +467,8 @@ Known bugs and unsupported features in this release
- VLAN based flow direction
- Non-IPV4 flow direction
- Setting of extended VLAN
-- UDP RSS hashing
- MTU update only works if Scattered Rx mode is disabled
+- Maximum receive packet length is ignored if Scattered Rx mode is used
Prerequisites
-------------