diff --git a/doc/guides/nics/i40e.rst b/doc/guides/nics/i40e.rst
index 4d3c7ca0..bc200d39 100644
--- a/doc/guides/nics/i40e.rst
+++ b/doc/guides/nics/i40e.rst
@@ -404,16 +404,6 @@ is used as the VF driver, DPDK cannot choose 16 byte receive descriptor. That
is to say, user should keep ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in
config file.
-Link down with i40e kernel driver after DPDK application exit
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-After DPDK application quit, and the device is bound back to Linux i40e
-kernel driver, the link cannot be up after ``ifconfig <dev> up``.
-To work around this issue, ``ethtool -s <dev> autoneg on`` should be
-set first and then the link can be brought up through ``ifconfig <dev> up``.
-
-NOTE: requires Linux kernel i40e driver version >= 1.4.X
-
Receive packets with Ethertype 0x88A8
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
@@ -447,3 +437,109 @@ It means if APP has set the max bandwidth for that TC, it comes to no
effect.
It's suggested to set the strict priority mode for a TC that is latency
sensitive but no consuming much bandwidth.
+
+VF performance is impacted by PCI extended tag setting
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+To reach maximum NIC performance in the VF the PCI extended tag must be
+enabled. The DPDK I40E PF driver will set this feature during initialization,
+but the kernel PF driver does not. So when running traffic on a VF which is
+managed by the kernel PF driver, a significant NIC performance downgrade has
+been observed (for 64 byte packets, there is about 25% linerate downgrade for
+a 25G device and about 35% for a 40G device).
+
+For kernel version >= 4.11, the kernel's PCI driver will enable the extended
+tag if it detects that the device supports it. So by default, this is not an
+issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
+enabled using the steps below.
+
+#. Get the current value of the PCI configure register::
+
+ setpci -s <XX:XX.X> a8.w
+
+#. Set bit 8::
+
+ value = value | 0x100
+
+#. Set the PCI configure register with new value::
+
+ setpci -s <XX:XX.X> a8.w=<value>
+
+High Performance of Small Packets on 40G NIC
+--------------------------------------------
+
+As there might be firmware fixes for performance enhancement in latest version
+of firmware image, the firmware update might be needed for getting high performance.
+Check with the local Intel's Network Division application engineers for firmware updates.
+Users should consult the release notes specific to a DPDK release to identify
+the validated firmware version for a NIC using the i40e driver.
+
+Use 16 Bytes RX Descriptor Size
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
+Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
+
+High Performance and per Packet Latency Tradeoff
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+Due to the hardware design, the interrupt signal inside NIC is needed for per
+packet descriptor write-back. The minimum interval of interrupts could be set
+at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
+Though there is a default configuration, the interval could be tuned by the
+users with that configuration item depends on what the user cares about more,
+performance or per packet latency.
+
+Example of getting best performance with l3fwd example
+------------------------------------------------------
+
+The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
+Intel server platform and Intel XL710 NICs.
+
+The example scenario is to get best performance with two Intel XL710 40GbE ports.
+See :numref:`figure_intel_perf_test_setup` for the performance test setup.
+
+.. _figure_intel_perf_test_setup:
+
+.. figure:: img/intel_perf_test_setup.*
+
+ Performance Test Setup
+
+
+1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
+ The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
+ for two 40G ports, but two different PCIe Gen3 x8 slot can.
+ Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
+
+ 82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
+ 85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
+
+2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
+
+3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
+ In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
+ are 18-35 and 54-71.
+ Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
+ cores from different cores (e.g core18 and core19).
+
+4. Bind these two ports to igb_uio.
+
+5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
+ will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
+
+6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
+ Compile the ``l3fwd sample`` with the default lpm mode.
+
+7. The command line of running l3fwd would be something like the following::
+
+ ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
+ -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
+
+ This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
+ core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
+
+8. Configure the traffic at a traffic generator.
+
+ * Start creating a stream on packet generator.
+
+ * Set the Ethernet II type to 0x0800.