aboutsummaryrefslogtreecommitdiffstats
path: root/doc/guides/nics/i40e.rst
diff options
context:
space:
mode:
authorC.J. Collier <cjcollier@linuxfoundation.org>2016-06-14 07:50:17 -0700
committerC.J. Collier <cjcollier@linuxfoundation.org>2016-06-14 12:17:54 -0700
commit97f17497d162afdb82c8704bf097f0fee3724b2e (patch)
tree1c6269614c0c15ffef8451c58ae8f8b30a1bc804 /doc/guides/nics/i40e.rst
parente04be89c2409570e0055b2cda60bd11395bb93b0 (diff)
Imported Upstream version 16.04
Change-Id: I77eadcd8538a9122e4773cbe55b24033dc451757 Signed-off-by: C.J. Collier <cjcollier@linuxfoundation.org>
Diffstat (limited to 'doc/guides/nics/i40e.rst')
-rw-r--r--doc/guides/nics/i40e.rst368
1 files changed, 368 insertions, 0 deletions
diff --git a/doc/guides/nics/i40e.rst b/doc/guides/nics/i40e.rst
new file mode 100644
index 00000000..934eb027
--- /dev/null
+++ b/doc/guides/nics/i40e.rst
@@ -0,0 +1,368 @@
+.. BSD LICENSE
+ Copyright(c) 2016 Intel Corporation. All rights reserved.
+ All rights reserved.
+
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions
+ are met:
+
+ * Redistributions of source code must retain the above copyright
+ notice, this list of conditions and the following disclaimer.
+ * Redistributions in binary form must reproduce the above copyright
+ notice, this list of conditions and the following disclaimer in
+ the documentation and/or other materials provided with the
+ distribution.
+ * Neither the name of Intel Corporation nor the names of its
+ contributors may be used to endorse or promote products derived
+ from this software without specific prior written permission.
+
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+ "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+ LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
+ A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
+ OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
+ SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
+ LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
+ DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
+ THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
+ (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
+ OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+
+I40E Poll Mode Driver
+======================
+
+The I40E PMD (librte_pmd_i40e) provides poll mode driver support
+for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
+
+
+Features
+--------
+
+Features of the I40E PMD are:
+
+- Multiple queues for TX and RX
+- Receiver Side Scaling (RSS)
+- MAC/VLAN filtering
+- Packet type information
+- Flow director
+- Cloud filter
+- Checksum offload
+- VLAN/QinQ stripping and inserting
+- TSO offload
+- Promiscuous mode
+- Multicast mode
+- Port hardware statistics
+- Jumbo frames
+- Link state information
+- Link flow control
+- Mirror on port, VLAN and VSI
+- Interrupt mode for RX
+- Scattered and gather for TX and RX
+- Vector Poll mode driver
+- DCB
+- VMDQ
+- SR-IOV VF
+- Hot plug
+- IEEE1588/802.1AS timestamping
+
+
+Prerequisites
+-------------
+
+- Identifying your adapter using `Intel Support
+ <http://www.intel.com/support>`_ and get the latest NVM/FW images.
+
+- Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
+
+- To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
+ section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
+
+
+Pre-Installation Configuration
+------------------------------
+
+Config File Options
+~~~~~~~~~~~~~~~~~~~
+
+The following options can be modified in the ``config`` file.
+Please note that enabling debugging options may affect system performance.
+
+- ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
+
+ Toggle compilation of the ``librte_pmd_i40e`` driver.
+
+- ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
+
+ Toggle display of generic debugging messages.
+
+- ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
+
+ Toggle bulk allocation for RX.
+
+- ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
+
+ Toggle the use of Vector PMD instead of normal RX/TX path.
+ To enable vPMD for RX, bulk allocation for Rx must be allowed.
+
+- ``CONFIG_RTE_LIBRTE_I40E_RX_OLFLAGS_ENABLE`` (default ``y``)
+
+ Toggle to enable RX ``olflags``.
+ This is only meaningful when Vector PMD is used.
+
+- ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
+
+ Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
+
+- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
+
+ Number of queues reserved for PF.
+
+- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``)
+
+ Number of queues reserved for each SR-IOV VF.
+
+- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
+
+ Number of queues reserved for each VMDQ Pool.
+
+- ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
+
+ Interrupt Throttling interval.
+
+
+Driver Compilation
+~~~~~~~~~~~~~~~~~~
+
+To compile the I40E PMD see :ref:`Getting Started Guide for Linux <linux_gsg>` or
+:ref:`Getting Started Guide for FreeBSD <freebsd_gsg>` depending on your platform.
+
+
+Linux
+-----
+
+
+Running testpmd
+~~~~~~~~~~~~~~~
+
+This section demonstrates how to launch ``testpmd`` with Intel XL710/X710
+devices managed by ``librte_pmd_i40e`` in the Linux operating system.
+
+#. Load ``igb_uio`` or ``vfio-pci`` driver:
+
+ .. code-block:: console
+
+ modprobe uio
+ insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko
+
+ or
+
+ .. code-block:: console
+
+ modprobe vfio-pci
+
+#. Bind the XL710/X710 adapters to ``igb_uio`` or ``vfio-pci`` loaded in the previous step:
+
+ .. code-block:: console
+
+ ./tools/dpdk_nic_bind.py --bind igb_uio 0000:83:00.0
+
+ Or setup VFIO permissions for regular users and then bind to ``vfio-pci``:
+
+ .. code-block:: console
+
+ ./tools/dpdk_nic_bind.py --bind vfio-pci 0000:83:00.0
+
+#. Start ``testpmd`` with basic parameters:
+
+ .. code-block:: console
+
+ ./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 83:00.0 -- -i
+
+ Example output:
+
+ .. code-block:: console
+
+ ...
+ EAL: PCI device 0000:83:00.0 on NUMA socket 1
+ EAL: probe driver: 8086:1572 rte_i40e_pmd
+ EAL: PCI memory mapped at 0x7f7f80000000
+ EAL: PCI memory mapped at 0x7f7f80800000
+ PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
+ Interactive-mode selected
+ Configuring Port 0 (socket 0)
+ ...
+
+ PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
+ satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
+
+ ...
+ Port 0: 68:05:CA:26:85:84
+ Checking link statuses...
+ Port 0 Link Up - speed 10000 Mbps - full-duplex
+ Done
+
+ testpmd>
+
+
+SR-IOV: Prerequisites and sample Application Notes
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+#. Load the kernel module:
+
+ .. code-block:: console
+
+ modprobe i40e
+
+ Check the output in dmesg:
+
+ .. code-block:: console
+
+ i40e 0000:83:00.1 ens802f0: renamed from eth0
+
+#. Bring up the PF ports:
+
+ .. code-block:: console
+
+ ifconfig ens802f0 up
+
+#. Create VF device(s):
+
+ Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
+ of the parent PF.
+
+ Example:
+
+ .. code-block:: console
+
+ echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
+
+
+#. Assign VF MAC address:
+
+ Assign MAC address to the VF using iproute2 utility. The syntax is:
+
+ .. code-block:: console
+
+ ip link set <PF netdev id> vf <VF id> mac <macaddr>
+
+ Example:
+
+ .. code-block:: console
+
+ ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
+
+#. Assign VF to VM, and bring up the VM.
+ Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
+
+
+Sample Application Notes
+------------------------
+
+Vlan filter
+~~~~~~~~~~~
+
+Vlan filter only works when Promiscuous mode is off.
+
+To start ``testpmd``, and add vlan 10 to port 0:
+
+.. code-block:: console
+
+ ./app/testpmd -c ffff -n 4 -- -i --forward-mode=mac
+ ...
+
+ testpmd> set promisc 0 off
+ testpmd> rx_vlan add 10 0
+
+
+Flow Director
+~~~~~~~~~~~~~
+
+The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
+The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
+
+The default input set of each flow type is::
+
+ ipv4-other : src_ip_address, dst_ip_address
+ ipv4-frag : src_ip_address, dst_ip_address
+ ipv4-tcp : src_ip_address, dst_ip_address, src_port, dst_port
+ ipv4-udp : src_ip_address, dst_ip_address, src_port, dst_port
+ ipv4-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
+ verification_tag
+ ipv6-other : src_ip_address, dst_ip_address
+ ipv6-frag : src_ip_address, dst_ip_address
+ ipv6-tcp : src_ip_address, dst_ip_address, src_port, dst_port
+ ipv6-udp : src_ip_address, dst_ip_address, src_port, dst_port
+ ipv6-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
+ verification_tag
+ l2_payload : ether_type
+
+The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
+
+Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
+
+.. code-block:: console
+
+ ./app/testpmd -c ffff -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
+ --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
+
+Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
+
+.. code-block:: console
+
+ testpmd> flow_director_filter 0 mode IP add flow ipv4-udp \
+ src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
+ fwd pf queue 1 fd_id 1
+
+Check the flow director status:
+
+.. code-block:: console
+
+ testpmd> show port fdir 0
+
+ ######################## FDIR infos for port 0 ####################
+ MODE: PERFECT
+ SUPPORTED FLOW TYPE: ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
+ ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
+ l2_payload
+ FLEX PAYLOAD INFO:
+ max_len: 16 payload_limit: 480
+ payload_unit: 2 payload_seg: 3
+ bitmask_unit: 2 bitmask_num: 2
+ MASK:
+ vlan_tci: 0x0000,
+ src_ipv4: 0x00000000,
+ dst_ipv4: 0x00000000,
+ src_port: 0x0000,
+ dst_port: 0x0000
+ src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
+ dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
+ FLEX PAYLOAD SRC OFFSET:
+ L2_PAYLOAD: 0 1 2 3 4 5 6 ...
+ L3_PAYLOAD: 0 1 2 3 4 5 6 ...
+ L4_PAYLOAD: 0 1 2 3 4 5 6 ...
+ FLEX MASK CFG:
+ ipv4-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv4-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv4-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv4-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv4-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv6-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv6-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv6-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv6-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ ipv6-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ l2_payload: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
+ guarant_count: 1 best_count: 0
+ guarant_space: 512 best_space: 7168
+ collision: 0 free: 0
+ maxhash: 0 maxlen: 0
+ add: 0 remove: 0
+ f_add: 0 f_remove: 0
+
+
+Delete all flow director rules on a port:
+
+.. code-block:: console
+
+ testpmd> flush_flow_director 0
+