index cb5ae125..a11627a0 100644
--- a/doc/guides/nics/enic.rst
+++ b/doc/guides/nics/enic.rst
@@ -252,6 +252,35 @@ Generic Flow API is supported. The baseline support is:
More features may be added in future firmware and new versions of the VIC.
Please refer to the release notes.
+Ingress VLAN Rewrite
+--------------------
+
+VIC adapters can tag, untag, or modify the VLAN headers of ingress
+packets. The ingress VLAN rewrite mode controls this behavior. By
+default, it is set to pass-through, where the NIC does not modify the
+VLAN header in any way so that the application can see the original
+header. This mode is sufficient for many applications, but may not be
+suitable for others. Such applications may change the mode by setting
+``devargs`` parameter ``ig-vlan-rewrite`` to one of the following.
+
+- ``pass``: Pass-through mode. The NIC does not modify the VLAN
+ header. This is the default mode.
+
+- ``priority``: Priority-tag default VLAN mode. If the ingress packet
+ is tagged with the default VLAN, the NIC replaces its VLAN header
+ with the priority tag (VLAN ID 0).
+
+- ``trunk``: Default trunk mode. The NIC tags untagged ingress packets
+ with the default VLAN. Tagged ingress packets are not modified. To
+ the application, every packet appears as tagged.
+
+- ``untag``: Untag default VLAN mode. If the ingress packet is tagged
+ with the default VLAN, the NIC removes or untags its VLAN header so
+ that the application sees an untagged packet. As a result, the
+ default VLAN becomes `untagged`. This mode can be useful for
+ applications such as OVS-DPDK performance benchmarks that utilize
+ only the default VLAN and want to see only untagged packets.
+
.. _enic_limitations:
Limitations
@@ -267,9 +296,10 @@ Limitations
In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
connected point-to-point to another adapter port or connected though a router
instead of a switch, all ingress packets will be VLAN tagged. Programs such
- as l3fwd which do not account for VLAN tags in packets will misbehave. The
- solution is to enable VLAN stripping on ingress. The follow code fragment is
- example of how to accomplish this:
+ as l3fwd may not account for VLAN tags in packets and may misbehave. One
+ solution is to enable VLAN stripping on ingress so the VLAN tag is removed
+ from the packet and put into the mbuf->vlan_tci field. Here is an example
+ of how to accomplish this:
.. code-block:: console
@@ -277,6 +307,14 @@ Limitations
vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
rte_eth_dev_set_vlan_offload(port, vlan_offload);
+Another alternative is modify the adapter's ingress VLAN rewrite mode so that
+packets with the default VLAN tag are stripped by the adapter and presented to
+DPDK as untagged packets. In this case mbuf->vlan_tci and the PKT_RX_VLAN and
+PKT_RX_VLAN_STRIPPED mbuf flags would not be set. This mode is enabled with the
+``devargs`` parameter ``ig-vlan-rewrite=untag``. For example::
+
+ -w 12:00.0,ig-vlan-rewrite=untag
+
- Limited flow director support on 1200 series and 1300 series Cisco VIC
adapters with old firmware. Please see :ref:`enic-flow-director`.
diff --git a/doc/guides/nics/qede.rst b/doc/guides/nics/qede.rst
index 84becc98..19802f43 100644
--- a/doc/guides/nics/qede.rst
+++ b/doc/guides/nics/qede.rst
@@ -86,12 +86,13 @@ Prerequisites
`QLogic Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
For downloading firmware file, select adapter category, model and DPDK Poll Mode Driver.
-- Requires management firmware (MFW) version **8.30.x.x** or higher to be
- flashed on to the adapter. If the required management firmware is not
- available then download from
- `QLogic Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
- For downloading firmware upgrade utility, select adapter category, model and Linux distro.
- To flash the management firmware refer to the instructions in the QLogic Firmware Upgrade Utility Readme document.
+- Requires the NIC be updated minimally with **8.30.x.x** Management firmware(MFW) version supported for that NIC.
+ It is highly recommended that the NIC be updated with the latest available management firmware version to get latest feature set.
+ Management Firmware and Firmware Upgrade Utility for Cavium FastLinQ(r) branded adapters can be downloaded from
+ `Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
+ For downloading Firmware Upgrade Utility, select NIC category, model and Linux distro.
+ To update the management firmware, refer to the instructions in the Firmware Upgrade Utility Readme document.
+ For OEM branded adapters please follow the instruction provided by the OEM to update the Management Firmware on the NIC.
- SR-IOV requires Linux PF driver version **8.20.x.x** or higher.
If the required PF driver is not available then download it from