aboutsummaryrefslogtreecommitdiffstats
path: root/doc/guides/sample_app_ug
diff options
context:
space:
mode:
Diffstat (limited to 'doc/guides/sample_app_ug')
-rw-r--r--doc/guides/sample_app_ug/ip_reassembly.rst4
-rw-r--r--doc/guides/sample_app_ug/ipv4_multicast.rst1
-rw-r--r--doc/guides/sample_app_ug/vhost.rst2
3 files changed, 3 insertions, 4 deletions
diff --git a/doc/guides/sample_app_ug/ip_reassembly.rst b/doc/guides/sample_app_ug/ip_reassembly.rst
index 3c5cc708..4c75bd08 100644
--- a/doc/guides/sample_app_ug/ip_reassembly.rst
+++ b/doc/guides/sample_app_ug/ip_reassembly.rst
@@ -50,8 +50,8 @@ There are two key differences from the L2 Forwarding sample application:
* The second difference is that the application differentiates between IP and non-IP traffic by means of offload flags.
-The Longest Prefix Match (LPM for IPv4, LPM6 for IPv6) table is used to store/lookup an outgoing port number, associated with that IPv4 address. Any unmatched packets are forwarded to the originating port.Compiling the Application
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
+The Longest Prefix Match (LPM for IPv4, LPM6 for IPv6) table is used to store/lookup an outgoing port number,
+associated with that IPv4 address. Any unmatched packets are forwarded to the originating port.
To compile the application:
diff --git a/doc/guides/sample_app_ug/ipv4_multicast.rst b/doc/guides/sample_app_ug/ipv4_multicast.rst
index 72da8c42..6badc681 100644
--- a/doc/guides/sample_app_ug/ipv4_multicast.rst
+++ b/doc/guides/sample_app_ug/ipv4_multicast.rst
@@ -365,7 +365,6 @@ It is the mcast_out_pkt() function that performs the packet duplication (either
hdr->pkt.in_port = pkt->pkt.in_port;
hdr->pkt.vlan_macip = pkt->pkt.vlan_macip;
hdr->pkt.hash = pkt->pkt.hash;
- hdr->ol_flags = pkt->ol_flags;
rte_mbuf_sanity_check(hdr, RTE_MBUF_PKT, 1);
return hdr;
diff --git a/doc/guides/sample_app_ug/vhost.rst b/doc/guides/sample_app_ug/vhost.rst
index 1f6d0d96..c9a605fc 100644
--- a/doc/guides/sample_app_ug/vhost.rst
+++ b/doc/guides/sample_app_ug/vhost.rst
@@ -115,7 +115,7 @@ could be done by:
.. code-block:: console
modprobe uio_pci_generic
- $RTE_SDK/tools/dpdk-devbind.py -b=uio_pci_generic 0000:00:04.0
+ $RTE_SDK/tools/dpdk-devbind.py -b uio_pci_generic 0000:00:04.0
Then start testpmd for packet forwarding testing.