1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
|
.. SPDX-License-Identifier: BSD-3-Clause
Copyright(c) 2017 Cavium, Inc
LiquidIO VF Poll Mode Driver
============================
The LiquidIO VF PMD library (librte_pmd_lio) provides poll mode driver support for
Cavium LiquidIO® II server adapter VFs. PF management and VF creation can be
done using kernel driver.
More information can be found at `Cavium Official Website
<http://cavium.com/LiquidIO_Adapters.html>`_.
Supported LiquidIO Adapters
-----------------------------
- LiquidIO II CN2350 210SV/225SV
- LiquidIO II CN2350 210SVPT
- LiquidIO II CN2360 210SV/225SV
- LiquidIO II CN2360 210SVPT
Pre-Installation Configuration
------------------------------
The following options can be modified in the ``config`` file.
Please note that enabling debugging options may affect system performance.
- ``CONFIG_RTE_LIBRTE_LIO_PMD`` (default ``y``)
Toggle compilation of LiquidIO PMD.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_DRIVER`` (default ``n``)
Toggle display of generic debugging messages.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_INIT`` (default ``n``)
Toggle display of initialization related messages.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_RX`` (default ``n``)
Toggle display of receive fast path run-time messages.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_TX`` (default ``n``)
Toggle display of transmit fast path run-time messages.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_MBOX`` (default ``n``)
Toggle display of mailbox messages.
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_REGS`` (default ``n``)
Toggle display of register reads and writes.
SR-IOV: Prerequisites and Sample Application Notes
--------------------------------------------------
This section provides instructions to configure SR-IOV with Linux OS.
#. Verify SR-IOV and ARI capabilities are enabled on the adapter using ``lspci``:
.. code-block:: console
lspci -s <slot> -vvv
Example output:
.. code-block:: console
[...]
Capabilities: [148 v1] Alternative Routing-ID Interpretation (ARI)
[...]
Capabilities: [178 v1] Single Root I/O Virtualization (SR-IOV)
[...]
Kernel driver in use: LiquidIO
#. Load the kernel module:
.. code-block:: console
modprobe liquidio
#. Bring up the PF ports:
.. code-block:: console
ifconfig p4p1 up
ifconfig p4p2 up
#. Change PF MTU if required:
.. code-block:: console
ifconfig p4p1 mtu 9000
ifconfig p4p2 mtu 9000
#. Create VF device(s):
Echo number of VFs to be created into ``"sriov_numvfs"`` sysfs entry
of the parent PF.
.. code-block:: console
echo 1 > /sys/bus/pci/devices/0000:03:00.0/sriov_numvfs
echo 1 > /sys/bus/pci/devices/0000:03:00.1/sriov_numvfs
#. Assign VF MAC address:
Assign MAC address to the VF using iproute2 utility. The syntax is::
ip link set <PF iface> vf <VF id> mac <macaddr>
Example output:
.. code-block:: console
ip link set p4p1 vf 0 mac F2:A8:1B:5E:B4:66
#. Assign VF(s) to VM.
The VF devices may be passed through to the guest VM using qemu or
virt-manager or virsh etc.
Example qemu guest launch command:
.. code-block:: console
./qemu-system-x86_64 -name lio-vm -machine accel=kvm \
-cpu host -m 4096 -smp 4 \
-drive file=<disk_file>,if=none,id=disk1,format=<type> \
-device virtio-blk-pci,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \
-device vfio-pci,host=03:00.3 -device vfio-pci,host=03:08.3
#. Running testpmd
Refer to the document
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>` to run
``testpmd`` application.
.. note::
Use ``igb_uio`` instead of ``vfio-pci`` in VM.
Example output:
.. code-block:: console
[...]
EAL: PCI device 0000:03:00.3 on NUMA socket 0
EAL: probe driver: 177d:9712 net_liovf
EAL: using IOMMU type 1 (Type 1)
PMD: net_liovf[03:00.3]INFO: DEVICE : CN23XX VF
EAL: PCI device 0000:03:08.3 on NUMA socket 0
EAL: probe driver: 177d:9712 net_liovf
PMD: net_liovf[03:08.3]INFO: DEVICE : CN23XX VF
Interactive-mode selected
USER1: create a new mbuf pool <mbuf_pool_socket_0>: n=171456, size=2176, socket=0
Configuring Port 0 (socket 0)
PMD: net_liovf[03:00.3]INFO: Starting port 0
Port 0: F2:A8:1B:5E:B4:66
Configuring Port 1 (socket 0)
PMD: net_liovf[03:08.3]INFO: Starting port 1
Port 1: 32:76:CC:EE:56:D7
Checking link statuses...
Port 0 Link Up - speed 10000 Mbps - full-duplex
Port 1 Link Up - speed 10000 Mbps - full-duplex
Done
testpmd>
#. Enabling VF promiscuous mode
One VF per PF can be marked as trusted for promiscuous mode.
.. code-block:: console
ip link set dev <PF iface> vf <VF id> trust on
Limitations
-----------
VF MTU
~~~~~~
VF MTU is limited by PF MTU. Raise PF value before configuring VF for larger packet size.
VLAN offload
~~~~~~~~~~~~
Tx VLAN insertion is not supported and consequently VLAN offload feature is
marked partial.
Ring size
~~~~~~~~~
Number of descriptors for Rx/Tx ring should be in the range 128 to 512.
CRC striping
~~~~~~~~~~~~
LiquidIO adapters strip ethernet FCS of every packet coming to the host interface.
|