summaryrefslogtreecommitdiffstats
path: root/doc/guides/nics/qede.rst
blob: 63ce9b4c60c639c0694a992926bf1a410462de8d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
..  SPDX-License-Identifier: BSD-3-Clause
    Copyright(c) 2016 QLogic Corporation
    Copyright(c) 2017 Cavium, Inc

QEDE Poll Mode Driver
======================

The QEDE poll mode driver library (**librte_pmd_qede**) implements support
for **QLogic FastLinQ QL4xxxx 10G/25G/40G/50G/100G Intelligent Ethernet Adapters (IEA) and Converged Network Adapters (CNA)** family of adapters as well as SR-IOV virtual functions (VF). It is supported on
several standard Linux distros like RHEL7.x, SLES12.x and Ubuntu.
It is compile-tested under FreeBSD OS.

More information can be found at `QLogic Corporation's Website
<http://www.qlogic.com>`_.

Supported Features
------------------

- Unicast/Multicast filtering
- Promiscuous mode
- Allmulti mode
- Port hardware statistics
- Jumbo frames
- Multiple MAC address
- MTU change
- Default pause flow control
- Multiprocess aware
- Scatter-Gather
- Multiple Rx/Tx queues
- RSS (with RETA/hash table/key)
- TSS
- Stateless checksum offloads (IPv4/IPv6/TCP/UDP)
- LRO/TSO
- VLAN offload - Filtering and stripping
- N-tuple filter and flow director (limited support)
- NPAR (NIC Partitioning)
- SR-IOV VF
- VXLAN Tunneling offload
- GENEVE Tunneling offload
- MPLSoUDP Tx Tunneling offload

Non-supported Features
----------------------

- SR-IOV PF
- GRE and NVGRE Tunneling offloads

Co-existence considerations
---------------------------
- QLogic FastLinQ QL4xxxx CNAs can have both NIC and Storage personalities. However, coexistence with storage protocol drivers (qedi and qedf) is not supported on the same adapter. So storage personality has to be disabled on that adapter when used in DPDK applications.
- For SR-IOV case, qede PMD will be used to bind to SR-IOV VF device and Linux native kernel driver (qede) will be attached to SR-IOV PF.

Supported QLogic Adapters
-------------------------

- QLogic FastLinQ QL4xxxx 10G/25G/40G/50G/100G Intelligent Ethernet Adapters (IEA) and Converged Network Adapters (CNA)

Prerequisites
-------------

- Requires storm firmware version **8.30.12.0**. Firmware may be available
  inbox in certain newer Linux distros under the standard directory
  ``E.g. /lib/firmware/qed/qed_init_values-8.30.12.0.bin``
  If the required firmware files are not available then download it from
  `QLogic Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
  For downloading firmware file, select adapter category, model and DPDK Poll Mode Driver.

- Requires management firmware (MFW) version **8.30.x.x** or higher to be
  flashed on to the adapter. If the required management firmware is not
  available then download from
  `QLogic Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
  For downloading firmware upgrade utility, select adapter category, model and Linux distro.
  To flash the management firmware refer to the instructions in the QLogic Firmware Upgrade Utility Readme document.

- SR-IOV requires Linux PF driver version **8.20.x.x** or higher.
  If the required PF driver is not available then download it from
  `QLogic Driver Download Center <http://driverdownloads.qlogic.com/QLogicDriverDownloads_UI/DefaultNewSearch.aspx>`_.
  For downloading PF driver, select adapter category, model and Linux distro.


Performance note
~~~~~~~~~~~~~~~~

- For better performance, it is recommended to use 4K or higher RX/TX rings.

Config File Options
~~~~~~~~~~~~~~~~~~~

The following options can be modified in the ``.config`` file. Please note that
enabling debugging options may affect system performance.

- ``CONFIG_RTE_LIBRTE_QEDE_PMD`` (default **y**)

  Toggle compilation of QEDE PMD driver.

- ``CONFIG_RTE_LIBRTE_QEDE_DEBUG_TX`` (default **n**)

  Toggle display of transmit fast path run-time messages.

- ``CONFIG_RTE_LIBRTE_QEDE_DEBUG_RX`` (default **n**)

  Toggle display of receive fast path run-time messages.

- ``CONFIG_RTE_LIBRTE_QEDE_FW`` (default **""**)

  Gives absolute path of firmware file.
  ``Eg: "/lib/firmware/qed/qed_init_values-8.30.12.0.bin"``
  Empty string indicates driver will pick up the firmware file
  from the default location /lib/firmware/qed.
  CAUTION this option is more for custom firmware, it is not
  recommended for use under normal condition.

Driver compilation and testing
------------------------------

Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
for details.

SR-IOV: Prerequisites and Sample Application Notes
--------------------------------------------------

This section provides instructions to configure SR-IOV with Linux OS.

**Note**: librte_pmd_qede will be used to bind to SR-IOV VF device and Linux native kernel driver (qede) will function as SR-IOV PF driver. Requires PF driver to be 8.10.x.x or higher.

#. Verify SR-IOV and ARI capability is enabled on the adapter using ``lspci``:

   .. code-block:: console

      lspci -s <slot> -vvv

   Example output:

   .. code-block:: console

      [...]
      Capabilities: [1b8 v1] Alternative Routing-ID Interpretation (ARI)
      [...]
      Capabilities: [1c0 v1] Single Root I/O Virtualization (SR-IOV)
      [...]
      Kernel driver in use: igb_uio

#. Load the kernel module:

   .. code-block:: console

      modprobe qede

   Example output:

   .. code-block:: console

      systemd-udevd[4848]: renamed network interface eth0 to ens5f0
      systemd-udevd[4848]: renamed network interface eth1 to ens5f1

#. Bring up the PF ports:

   .. code-block:: console

      ifconfig ens5f0 up
      ifconfig ens5f1 up

#. Create VF device(s):

   Echo the number of VFs to be created into ``"sriov_numvfs"`` sysfs entry
   of the parent PF.

   Example output:

   .. code-block:: console

      echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs


#. Assign VF MAC address:

   Assign MAC address to the VF using iproute2 utility. The syntax is::

      ip link set <PF iface> vf <VF id> mac <macaddr>

   Example output:

   .. code-block:: console

      ip link set ens5f0 vf 0 mac 52:54:00:2f:9d:e8


#. PCI Passthrough:

   The VF devices may be passed through to the guest VM using ``virt-manager`` or
   ``virsh``. QEDE PMD should be used to bind the VF devices in the guest VM
   using the instructions from Driver compilation and testing section above.


#. Running testpmd
   (Supply ``--log-level="pmd.net.qede.driver",7`` to view informational messages):

   Refer to the document
   :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>` to run
   ``testpmd`` application.

   Example output:

   .. code-block:: console

      testpmd -l 0,4-11 -n 4 -- -i --nb-cores=8 --portmask=0xf --rxd=4096 \
      --txd=4096 --txfreet=4068 --enable-rx-cksum --rxq=4 --txq=4 \
      --rss-ip --rss-udp

      [...]

    EAL: PCI device 0000:84:00.0 on NUMA socket 1
    EAL:   probe driver: 1077:1634 rte_qede_pmd
    EAL:   Not managed by a supported kernel driver, skipped
    EAL: PCI device 0000:84:00.1 on NUMA socket 1
    EAL:   probe driver: 1077:1634 rte_qede_pmd
    EAL:   Not managed by a supported kernel driver, skipped
    EAL: PCI device 0000:88:00.0 on NUMA socket 1
    EAL:   probe driver: 1077:1656 rte_qede_pmd
    EAL:   PCI memory mapped at 0x7f738b200000
    EAL:   PCI memory mapped at 0x7f738b280000
    EAL:   PCI memory mapped at 0x7f738b300000
    PMD: Chip details : BB1
    PMD: Driver version : QEDE PMD 8.7.9.0_1.0.0
    PMD: Firmware version : 8.7.7.0
    PMD: Management firmware version : 8.7.8.0
    PMD: Firmware file : /lib/firmware/qed/qed_init_values_zipped-8.7.7.0.bin
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_common_dev_init:macaddr \
                                                        00:0e:1e:d2:09:9c
      [...]
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_tx_queue_setup:txq 0 num_desc 4096 \
                                                tx_free_thresh 4068 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_tx_queue_setup:txq 1 num_desc 4096 \
                                                tx_free_thresh 4068 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_tx_queue_setup:txq 2 num_desc 4096 \
                                                 tx_free_thresh 4068 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_tx_queue_setup:txq 3 num_desc 4096 \
                                                 tx_free_thresh 4068 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_rx_queue_setup:rxq 0 num_desc 4096 \
                                                rx_buf_size=2148 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_rx_queue_setup:rxq 1 num_desc 4096 \
                                                rx_buf_size=2148 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_rx_queue_setup:rxq 2 num_desc 4096 \
                                                rx_buf_size=2148 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_rx_queue_setup:rxq 3 num_desc 4096 \
                                                rx_buf_size=2148 socket 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_dev_start:port 0
    [QEDE PMD: (84:00.0:dpdk-port-0)]qede_dev_start:link status: down
      [...]
    Checking link statuses...
    Port 0 Link Up - speed 25000 Mbps - full-duplex
    Port 1 Link Up - speed 25000 Mbps - full-duplex
    Port 2 Link Up - speed 25000 Mbps - full-duplex
    Port 3 Link Up - speed 25000 Mbps - full-duplex
    Done
    testpmd>