aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorJuraj Linkeš <juraj.linkes@pantheon.tech>2020-11-13 09:53:25 +0100
committerJuraj Linke? <juraj.linkes@pantheon.tech>2020-11-24 10:42:23 +0000
commite55816842cf0eea50196230a0ababd42505e372f (patch)
treed7321b67d5c1fda4c6050895ca6b639faaeb4765
parent7b6f78baed3260de06f5c70d8bc170f22f3b504f (diff)
lab: ThunderX2 updates
Update after switching one 1n-tx2 and the idle ThunderX2 servers between racks. Update the idle ThunderX2 specs to a new perf testbed, 2n-tx2. Add Server-Type-B12 which is a modified Server-Type-B2 with one extra NIC (needed for 2n-tx2). Change-Id: I51af358f1feb476652eddfe82b5af1d0d70ac259 Signed-off-by: Juraj Linkeš <juraj.linkes@pantheon.tech>
-rw-r--r--docs/lab/testbed_specifications.md127
-rw-r--r--resources/tools/testbed-setup/ansible/inventories/lf_inventory/host_vars/10.30.51.69.yaml10
-rw-r--r--resources/tools/testbed-setup/ansible/inventories/lf_inventory/hosts2
3 files changed, 106 insertions, 33 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 69efbae272..d5b7be4827 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -11,6 +11,7 @@
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
+ 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
@@ -26,26 +27,28 @@
1. [Testbeds Configuration](#testbeds-configuration)
1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
- 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
+ 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
+ 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-wip)
1. [Per Testbed Wiring](#per-testbed-wiring)
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
- 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
+ 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
+ 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
@@ -71,8 +74,8 @@ hosted by LFN FD.io CSIT project.
#. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
- 3. 1-Node-Thunderx2 idle tx2 na 1 1 0 0 0 0 0 0 1 0 0 0
- 4. 1-Node-Thunderx2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
+ 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
+ 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
@@ -84,7 +87,7 @@ hosted by LFN FD.io CSIT project.
13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 27 36 16.5 12 18.5 1 2 3 3 2 7 2
+ Totals: 27 36 18 12 19 1 2 3 3 2 7 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -141,6 +144,13 @@ one TG (Server-Type-D2) connected in a 2-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
+
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
+one TG (Server-Type-B12) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
### 3-Node-Haswell Xeon Intel (3n-hsw)
Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
@@ -273,7 +283,7 @@ Name | Comment
10.30.50.66 | s51-nomad
10.30.50.67 | s49-nomad
10.30.50.68 | s50-nomad
-10.30.50.69 | s27-t13-sut
+10.30.50.69 | s27-t34-sut1
10.30.50.70 | s55-t36-sut1
10.30.50.71 | s56-t37-sut1
10.30.50.255 | Broadcast
@@ -366,7 +376,7 @@ Name | Comment
10.30.51.66 | s51-nomad
10.30.51.67 | s49-nomad
10.30.51.68 | s50-nomad
-10.30.51.69 | s27-t13-sut1
+10.30.51.69 | s27-t34-sut1
10.30.51.70 | s55-t36-sut1
10.30.51.71 | s56-t37-sut1
10.30.51.72-10.30.51.105 | FREE
@@ -580,7 +590,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
+11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
@@ -588,15 +598,14 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: Gigabyte R181-T90 1U
- Motherboard: MT91-FS1
- - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- NICs configuration:
- Numa0:
- - PCIe Slot1 05:00.xx: XL710-QDA2.
- - PCIe Slot3 08:00.xx: XL710-QDA2.
+ - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
- Numa1:
- - PCIe Slot6 85:00.xx: XL710-QDA2.
+ - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
@@ -611,7 +620,7 @@ FD.io CSIT lab contains following server types:
- 2x 10Gb Intel x553 fiber ports
- 2x 10Gb Intel x553 copper ports
- 4x 1GB Intel I350 ports
-13. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -619,7 +628,7 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: GIGABYTE Rack Mount
- Motherboard: MT91-FS4-00
- - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
+ - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
- RAM Memory: 16 * 16GB DIMM
- Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
- NICs configuration:
@@ -629,8 +638,28 @@ FD.io CSIT lab contains following server types:
- Numa1:
- PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: ---
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -650,7 +679,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
@@ -670,7 +699,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -690,7 +719,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- CIMC and host management ports.
@@ -707,7 +736,7 @@ FD.io CSIT lab contains following server types:
- Numa1:
- no cards.
-18. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -722,7 +751,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-19. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -797,7 +826,7 @@ connectivity and wiring across defined CSIT testbeds:
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 1-Node-Thunderx2 Servers (1n-tx2) WIP
+#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
```
- SUT [Server-Type-B11]:
@@ -814,7 +843,6 @@ connectivity and wiring across defined CSIT testbeds:
- s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-
- SUT [Server-Type-B11]:
- testbedname: testbed37
- hostname: s56-t37-sut1
@@ -1133,6 +1161,41 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
+#### 2-Node-ThunderX2 Servers (2x-tx2) WIP
+
+Note: Server19 (TG) is shared between testbed33 & testbed34
+
+```
+- SUT [Server-Type-B9]:
+ - testbedname: testbed34.
+ - hostname: s27-t34-sut1.
+ - IPMI IP: 10.30.50.69
+ - Host IP: 10.30.51.69
+ - portnames:
+ - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
+- TG [Server-Type-B12]:
+ - testbedname: testbed33 and testbed34.
+ - hostname: s19-t33t34-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
+ - portnames:
+ - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
#### 3-Node-Haswell Servers (3n-hsw) PROD
```
@@ -1502,7 +1565,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
```
-#### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
+#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
```
- testbed36:
@@ -1673,6 +1736,16 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
+#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
+
+```
+- testbed34:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
+ - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
+ - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
+```
+
+
#### 3-Node-Haswell Wiring (3n-hsw) PROD
```
@@ -1851,12 +1924,12 @@ To be completed.
1. Arm Cortex A-72 servers
- 2 * ThunderX2 (VPP Device)
- Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9980 ~ 128* ThunderX2
+ - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
- RAM Memory: 16* 16GB DIMM
- Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - 1 * ThunderX2 (Idle)
- - Chassis: Marvell ThunderX2
- - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
+ - 1 * ThunderX2 (Performance)
+ - Chassis: GIGABYTE Rack Mount
+ - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- 2 * Huawei TaiShan 2280.
diff --git a/resources/tools/testbed-setup/ansible/inventories/lf_inventory/host_vars/10.30.51.69.yaml b/resources/tools/testbed-setup/ansible/inventories/lf_inventory/host_vars/10.30.51.69.yaml
index 221bc3afb5..0ebda86285 100644
--- a/resources/tools/testbed-setup/ansible/inventories/lf_inventory/host_vars/10.30.51.69.yaml
+++ b/resources/tools/testbed-setup/ansible/inventories/lf_inventory/host_vars/10.30.51.69.yaml
@@ -1,19 +1,19 @@
---
# file: host_vars/10.30.51.69.yaml
-hostname: "s27-t13-sut1"
+hostname: "s27-t34-sut1"
grub:
audit: "0"
intel_iommu: "on"
- isolcpus: "1-111,113-223"
+ isolcpus: "1-27,29-55"
nmi_watchdog: "0"
- nohz_full: "1-111,113-223"
+ nohz_full: "1-27,29-55"
nosoftlockup: True
processor.max_cstate: "1"
- rcu_nocbs: "1-111,113-223"
+ rcu_nocbs: "1-27,29-55"
sysctl:
kernel:
- watchdog_cpumask: "0,112"
+ watchdog_cpumask: "0,28"
vm:
nr_hugepages: 57344
max_map_count: 20000
diff --git a/resources/tools/testbed-setup/ansible/inventories/lf_inventory/hosts b/resources/tools/testbed-setup/ansible/inventories/lf_inventory/hosts
index 4f13457dd7..d89fe4888f 100644
--- a/resources/tools/testbed-setup/ansible/inventories/lf_inventory/hosts
+++ b/resources/tools/testbed-setup/ansible/inventories/lf_inventory/hosts
@@ -42,7 +42,7 @@ all:
10.32.8.20: #s35-t28-sut1 - cascadelake
10.32.8.22: #s37-t29-sut1 - cascadelake
10.32.8.24: #s60-t210-sut1 - epyc
- 10.30.51.69: #s27-t13-sut1 - thunderx2 9975
+ 10.30.51.69: #s27-t34-sut1 - thunderx2 9975
vpp_device:
hosts:
10.30.51.50: #s1-t11-sut1 - skylake