aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorpmikus <peter.mikus@protonmail.ch>2023-09-28 12:36:05 +0000
committerPeter Mikus <peter.mikus@protonmail.ch>2023-10-03 07:28:25 +0000
commitdc75b20cb5410bcda066aa326406a5effdf60f0a (patch)
treea700e1742d94e076123b21e993ea769a261dffbd
parentfa30c20d323567b91571b50d6245f817285afe4d (diff)
feat(infra): IcelakeD
Signed-off-by: pmikus <peter.mikus@protonmail.ch> Change-Id: Ib630ef3a2451c6b13e3ba6b40a1ffa475787aeb6
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md354
-rw-r--r--docs/content/infrastructure/fdio_dc_vexxhost_inventory.md158
2 files changed, 266 insertions, 246 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index 3df698ac0d..c90e01f116 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -39,28 +39,29 @@ To access these hosts, VPN connection is required.
### Summary List
```
- #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
- 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
- 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
- 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
- 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
- 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
- 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
- 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
- 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
- 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
-10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
-11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
-12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
-13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
-14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
-15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4
- Totals: 32 39 18.5 7 1 2 1 2 4 7 2 15.5 2 12
+ #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd
+ 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0
+ 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
+ 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
+ 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 0
+ 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 0
+ 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0
+ 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0
+ 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 0
+10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0
+11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0
+12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0
+13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0
+14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
+15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0
+16. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4
+ Totals: 37 46 19.5 7 1 2 1 2 4 10 2 16.5 2 12 4
```
### 1-Node-Skylake Xeon Intel (1n-skx)
-Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
+Each 1-Node-Skylake testbed includes one SUT (Server-Type-B2) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
@@ -76,13 +77,6 @@ Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
-### 1-Node-Cascadelake Xeon Intel (1n-clx)
-
-Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
-NIC ports connected back-to-back ([Server Types](#server-types)).
-
-Used for FD.io VPP_Device functional driver tests.
-
### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
@@ -146,6 +140,13 @@ TG (Server-Type-F3) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 3-Node-IcelakeD Xeon Intel (3n-icxd)
+
+Each 3-Node-IcelakeD testbed includes two SUTs (Server-Type-I1) and one numa of
+TG (Server-Type-F5) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
### 3-Node-SnowRidge Atom Intel (3n-snr)
Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
@@ -184,7 +185,7 @@ connectivity and wiring across defined CSIT testbeds:
FD.io CSIT lab contains following server types:
-1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
+1. **Server-Type-B1**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -204,7 +205,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+2. **Server-Type-B2**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -265,28 +266,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+5. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
@@ -307,7 +288,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+6. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -328,8 +309,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- - Quantity: 3.
+7. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+ - Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
- no NIC ports, standalone setup.
@@ -340,12 +321,16 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 12* 16GB DDR4-2933.
- Disks: 4* 1.92TB SATA SSD.
- NICs configuration:
- - Numa0:
- - no cards.
- - Numa1:
- - no cards.
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: empty.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
-9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+8. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -358,10 +343,10 @@ FD.io CSIT lab contains following server types:
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
+9. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -375,9 +360,9 @@ FD.io CSIT lab contains following server types:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel.
-11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+10. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -396,7 +381,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+11. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI(?) and host management ports.
@@ -410,7 +395,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+12. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -427,7 +412,7 @@ FD.io CSIT lab contains following server types:
- Numa1:
- PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+13. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -446,7 +431,7 @@ FD.io CSIT lab contains following server types:
- Numa1:
- no cards.
-15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
+14. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -458,7 +443,7 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 12* 16GB DDR4-3200MT/s
- Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
+15. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -476,10 +461,10 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot8 af:00.xx: xl710-QDA2-2p40GE Intel.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+16. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -496,11 +481,11 @@ FD.io CSIT lab contains following server types:
- PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
- PCIe Slot9 ff:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot6 ca:00.xx: empty.
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
-18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
+17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
@@ -521,7 +506,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
+18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
@@ -542,7 +527,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-20. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
+19. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
- Quantity: 6.
- Physical connectivity:
- IPMI and host management ports.
@@ -563,7 +548,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-21. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
+20. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -584,7 +569,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-22. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+21. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -605,7 +590,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
-23. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -620,7 +605,7 @@ FD.io CSIT lab contains following server types:
- Numa0: (x16, PCIe3.0 lane)
- PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-24. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -633,15 +618,15 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia.
-25. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -654,15 +639,15 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
- Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: empty.
-26. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -683,7 +668,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-27. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -704,7 +689,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-28. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -725,7 +710,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-29. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -746,7 +731,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-30. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
+29. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -767,12 +752,27 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
+30. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing.
+ - Quantity: 4
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topology.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-110D-20C-FRDN8TP.
+ - Motherboard: Super X12SDV-20C-SPT8F.
+ - Processors: 1* Intel Xeon D-2796NT.
+ - RAM Memory: 4* 32GB DDR4-3200 MEM-DR432MD-ER32.
+ - Disks: 1* 960GB SATA SSD HDS-25T0.
+ - NICs configuration:
+ - Numa0: (x16, PCIe4.0 lane)
+ - PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel.
+
## Testbeds Configuration
### 1-Node-Skylake (1n-skx)
```
-- SUT [Server-Type-B6]:
+- SUT [Server-Type-B2]:
- testbedname: testbed11.
- hostname: s1-t11-sut1.
- IPMI IP: 10.30.50.47
@@ -786,11 +786,11 @@ FD.io CSIT lab contains following server types:
- s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- - s1-t11-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
- - s1-t11-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
- s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
-- SUT [Server-Type-B6]:
+ - s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
+ - s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
+- SUT [Server-Type-B2]:
- testbedname: testbed12.
- hostname: s2-t12-sut1.
- IPMI IP: 10.30.50.48
@@ -804,10 +804,10 @@ FD.io CSIT lab contains following server types:
- s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- - s2-t12-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
- - s2-t12-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
- s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
+ - s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
```
### 1-Node-ThunderX2 (1n-tx2)
@@ -852,39 +852,20 @@ FD.io CSIT lab contains following server types:
- IPMI IP: 10.30.50.30
- Host IP: 10.30.51.31
- portnames:
- - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
- - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
- - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
- - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
+ - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
- SUT [Server-Type-H7]:
- testbedname: testbed16.
- hostname: s31-t16-sut1.
- IPMI IP: 10.30.50.31
- Host IP: 10.30.51.31
- portnames:
- - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
- - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
- - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
- - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
-```
-
-### 1-Node-Cascadelake (1n-clx)
-
-```
-- SUT [Server-Type-C1]:
- - testbedname: testbed11.
- - hostname: s32-t14-sut1.
- - IPMI IP: 10.30.55.17
- - Host IP: 10.32.8.17
- - portnames:
- - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+ - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
```
### 2-Node-IxiaPS1L47 (2n-ps1)
@@ -1065,8 +1046,8 @@ FD.io CSIT lab contains following server types:
- IPMI IP: 10.30.50.69
- Host IP: 10.30.51.69
- portnames:
- - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s27-t211-sut1-c18/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s27-t211-sut1-c18/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- TG [Server-Type-E31]:
- testbedname: testbed33 and testbed211.
- hostname: s19-t33t211-tg1.
@@ -1230,40 +1211,6 @@ FD.io CSIT lab contains following server types:
- s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
```
-### 3-Node-Rangeley (3n-rng)
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- ServerB22 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
- - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
- - Host IP: 10.30.51.9
- - portnames:
- - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB23 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
- - Host IP: 10.30.51.10
- - portnames:
- - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB24 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
- - Host IP: 10.30.51.11
- - portnames:
- - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-```
-
### 3-Node-Taishan (3n-tsh)
{{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
@@ -1344,10 +1291,6 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
@@ -1625,6 +1568,65 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
+### 3-Node-IcelakeD (3n-icxd)
+
+{{< figure src="/cdocs/testbed-3n-icxd.svg" >}}
+
+```
+- ServerI1 [Server-Type-I1]:
+ - testbedname: testbed31.
+ - hostname: s32-t31-sut1.
+ - IPMI IP: 10.30.50.32
+ - Host IP: 10.30.51.32
+ - portnames:
+ - s32-t31-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
+ - s32-t31-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
+- ServerI1 [Server-Type-I1]:
+ - testbedname: testbed31.
+ - hostname: s33-t31-sut2.
+ - IPMI IP: 10.30.50.33
+ - Host IP: 10.30.51.33
+ - portnames:
+ - s33-t31-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
+ - s33-t31-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
+- ServerF3 [Server-Type-F5]:
+ - testbedname: testbed31.
+ - hostname: s89-t31t32-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t31t32-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerI1 [Server-Type-I1]:
+ - testbedname: testbed32.
+ - hostname: s34-t32-sut1.
+ - IPMI IP: 10.30.50.34
+ - Host IP: 10.30.51.34
+ - portnames:
+ - s34-t32-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
+ - s34-t32-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
+- ServerI1 [Server-Type-I1]:
+ - testbedname: testbed32.
+ - hostname: s35-t32-sut2.
+ - IPMI IP: 10.30.50.35
+ - Host IP: 10.30.51.35
+ - portnames:
+ - s35-t32-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
+ - s35-t32-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
+- ServerF3 [Server-Type-F5]:
+ - testbedname: testbed32.
+ - hostname: s89-t31t32-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t31t32-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+```
+
## Testbed Wiring
### 1-Node-Skylake (1n-skx)
@@ -1998,7 +2000,7 @@ To be completed.
- ring2 100GE-ports e810-2CQDA2-2p100GE:
- s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
- s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
- - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - ring3 25GE-ports e810-XXVDA4-4p25GE:
- s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
- s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
- s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
@@ -2014,7 +2016,7 @@ To be completed.
- ring2 100GE-ports e810-2CQDA2-2p100GE:
- s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
- s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
- - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - ring3 25GE-ports e810-XXVDA4-4p25GE:
- s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
- s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
- s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
@@ -2023,4 +2025,20 @@ To be completed.
- s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
- ring5 100GE-ports e810-2CQDA2-2p100GE:
- s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
-``` \ No newline at end of file
+```
+
+### 3-Node-IcelakeD (3n-icxd)
+
+```
+- testbed31:
+ - ring1 25GE-ports e822cq-2p25GE:
+ - s89-t31t32-tg1-c4/p1 to s32-t31-sut1-c1/p1.
+ - s32-t31-sut1-c1/p2 to s33-t31-sut2-c1/p2.
+ - s33-t31-sut2-c1/p1 to s89-t31t32-tg1-c4/p2.
+- testbed32:
+ - ring1 25GE-ports e822cq-2p25GE:
+ - s89-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1.
+ - s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2.
+ - s35-t32-sut2-c1/p1 to s89-t31t32-tg1-c6/p2.
+```
+
diff --git a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
index f11ed37f6f..0a4e27f223 100644
--- a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
+++ b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
@@ -10,8 +10,6 @@ Captured inventory data:
[CSIT testbed specification]({{< ref "fdio_dc_testbed_specifications#FD.io CSIT Testbed Specifications" >}}),
followed by "/" and the actual configured hostname, unless it is the same
as CSIT name.
- - **oper-status**: operational status (up|down).
- - **testbed-id**: CSIT testbed identifier.
- **role**: 2n/3n-xxx performance testbed, nomad-client, nomad-server.
- role exceptions: decommission, repurpose, spare.
- **model**: server model.
@@ -33,92 +31,96 @@ Captured inventory data:
### Rack YUL1-8 (3016.8)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
----------------|-----------------|----------------|----------|----------------|-----------------|--------------|--------------|------------|--------------
- mtl1-8-lb4m | up | switch | uplink | ? | ? | ? | ? | 3016.8 | u47
- s65-t37-sut1 | up | t37 | 3n-icx | SYS-740GP-TNRT | C7470KK25P50098 | 10.30.51.75 | 10.30.50.75 | 3016.8 | u42-u45
- s66-t37-sut2 | up | t37 | 3n-icx | SYS-740GP-TNRT | C7470KK33P50247 | 10.30.51.76 | 10.30.50.76 | 3016.8 | u38-u41
- s67-t37-tg1 | up | t37 | 3n-icx | SYS-740GP-TNRT | C7470KK25P50076 | 10.30.51.77 | 10.30.50.77 | 3016.8 | u34-u37
- s71-t212-sut1 | up | t212 | 2n-icx | SYS-740GP-TNRT | C7470KK25P50173 | 10.30.51.81 | 10.30.50.81 | 3016.8 | u30-u33
- s72-t212-tg1 | up | t212 | 2n-icx | SYS-740GP-TNRT | C7470KK33P50220 | 10.30.51.82 | 10.30.50.82 | 3016.8 | u26-u29
- s83-t213-sut1 | up | t213 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50300 | 10.30.51.83 | 10.30.50.83 | 3016.8 | u22-u25
- s84-t213-tg1 | up | t213 | 2n-icx | SYS-740GP-TNRT | C7470KL03P50187 | 10.30.51.84 | 10.30.50.84 | 3016.8 | u18-u21
- s85-t214-sut1 | up | t214 | 2n-icx | SYS-740GP-TNRT | C7470KK33P50219 | 10.30.51.85 | 10.30.50.85 | 3016.8 | u14-u17
- s86-t214-tg1 | up | t214 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50312 | 10.30.51.86 | 10.30.50.86 | 3016.8 | u10-u13
- s87-t215-sut1 | up | t215 | 2n-icx | SYS-740GP-TNRT | C7470KL03P50171 | 10.30.51.87 | 10.30.50.87 | 3016.8 | u6-u9
- s88-t215-tg1 | up | t215 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50301 | 10.30.51.88 | 10.30.50.88 | 3016.8 | u2-u5
+ **name** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------|---------------|---------------------|-----------------|--------------|--------------|------------|--------------
+ mtl1-8-lb4m | uplink | ? | ? | ? | ? | 3016.8 | u47
+ s65-t37-sut1 | 3n-icx | SYS-740GP-TNRT | C7470KK25P50098 | 10.30.51.75 | 10.30.50.75 | 3016.8 | u42-u45
+ s66-t37-sut2 | 3n-icx | SYS-740GP-TNRT | C7470KK33P50247 | 10.30.51.76 | 10.30.50.76 | 3016.8 | u38-u41
+ s67-t37-tg1 | 3n-icx | SYS-740GP-TNRT | C7470KK25P50076 | 10.30.51.77 | 10.30.50.77 | 3016.8 | u34-u37
+ s71-t212-sut1 | 2n-icx | SYS-740GP-TNRT | C7470KK25P50173 | 10.30.51.81 | 10.30.50.81 | 3016.8 | u30-u33
+ s72-t212-tg1 | 2n-icx | SYS-740GP-TNRT | C7470KK33P50220 | 10.30.51.82 | 10.30.50.82 | 3016.8 | u26-u29
+ s83-t213-sut1 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50300 | 10.30.51.83 | 10.30.50.83 | 3016.8 | u22-u25
+ s84-t213-tg1 | 2n-icx | SYS-740GP-TNRT | C7470KL03P50187 | 10.30.51.84 | 10.30.50.84 | 3016.8 | u18-u21
+ s85-t214-sut1 | 2n-icx | SYS-740GP-TNRT | C7470KK33P50219 | 10.30.51.85 | 10.30.50.85 | 3016.8 | u14-u17
+ s86-t214-tg1 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50312 | 10.30.51.86 | 10.30.50.86 | 3016.8 | u10-u13
+ s87-t215-sut1 | 2n-icx | SYS-740GP-TNRT | C7470KL03P50171 | 10.30.51.87 | 10.30.50.87 | 3016.8 | u6-u9
+ s88-t215-tg1 | 2n-icx | SYS-740GP-TNRT | C7470KL07P50301 | 10.30.51.88 | 10.30.50.88 | 3016.8 | u2-u5
### Rack YUL1-9 (3016.9)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
------------------|-----------------|----------------|---------------|---------------------|-----------------|--------------|--------------|------------|--------------
- mtl1-5-lb4m | up | switch | uplink | ? | ? | ? | ? | 3016.9 | u47
- s52-t21-sut1 | up | t21 | 2n-spr | SYS-741GE-TNRT | C7490FL36A40118 | 10.30.51.52 | 10.30.50.52 | 3016.9 | u42-u45
- s53-t21-tg1 | up | t21 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.53 | 10.30.50.53 | 3016.9 | u38-u41
- s54-t22-sut1 | up | t22 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.54 | 10.30.50.54 | 3016.9 | u34-u37
- s55-t22-tg1 | up | t22 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.55 | 10.30.50.55 | 3016.9 | u30-u33
- s56-t23-sut1 | up | t23 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.56 | 10.30.50.56 | 3016.9 | u26-u29
- s57-t23-tg1 | up | t23 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.57 | 10.30.50.57 | 3016.9 | u22-u25
- s25-t25-sut1 | down | t25 | 2n-p1 | SYS-7049GP-TRT | C7470KH06A20022 | 10.30.51.61 | 10.30.50.58 | 3016.9 | u18-u21
- s19-t33t211-tg1 | up | t33t211 | 3n-tsh/2n-tx2 | SYS-7049GP-TRT | C7470KH06A20056 | 10.30.51.49 | 10.30.50.46 | 3016.9 | u14-u17
- s27-t211-sut1 | up | t211 | 2n-tx2 | ThunderX2-9975 | K61186073100003 | 10.30.51.69 | 10.30.50.69 | 3016.9 | u13
- s18-t33-sut2 | up | t33 | 3n-tsh | HUAWEI-TAISHAN-2280 | N/A | 10.30.51.37 | 10.30.50.37 | 3016.9 | u11-u12
- s17-t33-sut1 | up | t33 | 3n-tsh | HUAWEI-TAISHAN-2280 | N/A | 10.30.51.36 | 10.30.50.36 | 3016.9 | u9-u10
- s79-t39t310-tg1 | up | t39t310 | tbd | SYS-740GP-TNRT | ??? | 10.30.51.79 | 10.30.50.79 | 3016.9 | u5-u8
+ **name** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------|---------------|---------------------|-----------------|--------------|--------------|------------|--------------
+ mtl1-5-lb4m | uplink | ? | ? | ? | ? | 3016.9 | u47
+ s52-t21-sut1 | 2n-spr | SYS-741GE-TNRT | C7490FL36A40118 | 10.30.51.52 | 10.30.50.52 | 3016.9 | u42-u45
+ s53-t21-tg1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.53 | 10.30.50.53 | 3016.9 | u38-u41
+ s54-t22-sut1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.54 | 10.30.50.54 | 3016.9 | u34-u37
+ s55-t22-tg1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.55 | 10.30.50.55 | 3016.9 | u30-u33
+ s56-t23-sut1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.56 | 10.30.50.56 | 3016.9 | u26-u29
+ s57-t23-tg1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.57 | 10.30.50.57 | 3016.9 | u22-u25
+ s25-t25-sut1 | 2n-p1 | SYS-7049GP-TRT | C7470KH06A20022 | 10.30.51.61 | 10.30.50.58 | 3016.9 | u18-u21
+ s19-t33t211-tg1 | 3n-tsh/2n-tx2 | SYS-7049GP-TRT | C7470KH06A20056 | 10.30.51.49 | 10.30.50.46 | 3016.9 | u14-u17
+ s27-t211-sut1 | 2n-tx2 | ThunderX2-9975 | K61186073100003 | 10.30.51.69 | 10.30.50.69 | 3016.9 | u13
+ s18-t33-sut2 | 3n-tsh | HUAWEI-TAISHAN-2280 | N/A | 10.30.51.37 | 10.30.50.37 | 3016.9 | u11-u12
+ s17-t33-sut1 | 3n-tsh | HUAWEI-TAISHAN-2280 | N/A | 10.30.51.36 | 10.30.50.36 | 3016.9 | u9-u10
### Rack YUL1-10 (3016.10)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
------------------|-----------------|----------------|----------|----------------|-----------------|--------------|--------------|------------|--------------
- yul1-10-lb4m | up | switch | uplink | ? | ? | ? | ? | 3016.10 | u47
- s2-t12-sut1 | up | t12 | 1n-skx | SYS-7049GP-TRT | C7470KH06A20119 | 10.30.51.51 | 10.30.50.48 | 3016.10 | u42-u45
- s1-t11-sut1 | up | t11 | 1n-skx | SYS-7049GP-TRT | C7470KH06A20154 | 10.30.51.50 | 10.30.50.47 | 3016.10 | u38-u41
- s58-t24-sut1 | up | t24 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.58 | 10.30.50.58 | 3016.10 | u34-u37
- s59-t24-tg1 | up | t24 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.59 | 10.30.50.59 | 3016.10 | u30-u33
- s93-t39-sut1 | up | t39 | 3n-snr | ? | ? | 10.30.51.93 | 10.30.50.93 | 3016.10 | u10-u13
- s94-t39-sut2 | up | t39 | 3n-snr | ? | ? | 10.30.51.94 | 10.30.50.94 | 3016.10 | u6-u9
- s89-t39t310-tg1 | up | t39 | 3n-snr | ? | ? | 10.30.51.89 | 10.30.50.89 | 3016.10 | u2-u5
+ **name** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------|---------------|---------------------|-----------------|--------------|--------------|------------|--------------
+ yul1-10-lb4m | uplink | ? | ? | ? | ? | 3016.10 | u47
+ s2-t12-sut1 | 1n-skx | SYS-7049GP-TRT | C7470KH06A20119 | 10.30.51.51 | 10.30.50.48 | 3016.10 | u42-u45
+ s1-t11-sut1 | 1n-skx | SYS-7049GP-TRT | C7470KH06A20154 | 10.30.51.50 | 10.30.50.47 | 3016.10 | u38-u41
+ s58-t24-sut1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.58 | 10.30.50.58 | 3016.10 | u34-u37
+ s59-t24-tg1 | 2n-spr | SYS-741GE-TNRT | ??? | 10.30.51.59 | 10.30.50.59 | 3016.10 | u30-u33
+ s32-t31-sut1 | 3n-icxd | SYS-110D-20C-FRDN8TP| ??? | 10.30.51.32 | 10.30.50.32 | 3016.10 | u21
+ s33-t31-sut2 | 3n-icxd | SYS-110D-20C-FRDN8TP| ??? | 10.30.51.33 | 10.30.50.33 | 3016.10 | u20
+ s34-t32-sut1 | 3n-icxd | SYS-110D-20C-FRDN8TP| ??? | 10.30.51.34 | 10.30.50.34 | 3016.10 | u19
+ s35-t32-sut2 | 3n-icxd | SYS-110D-20C-FRDN8TP| ??? | 10.30.51.35 | 10.30.50.35 | 3016.10 | u18
+ s79-t31t32-tg1 | 3n-icxd | SYS-740GP-TNRT | ??? | 10.30.51.79 | 10.30.50.79 | 3016.10 | u14-u17
+ s93-t39-sut1 | 3n-snr | ? | ? | 10.30.51.93 | 10.30.50.93 | 3016.10 | u10-u13
+ s94-t39-sut2 | 3n-snr | ? | ? | 10.30.51.94 | 10.30.50.94 | 3016.10 | u6-u9
+ s89-t39t310-tg1 | 3n-snr | ? | ? | 10.30.51.89 | 10.30.50.89 | 3016.10 | u2-u5
### Rack YUL1-11 (3016.11)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
------------------------|-----------------|----------------|--------------|----------------|-----------------|--------------|--------------|------------|--------------
- yul1-11-lb6m | up | switch | arm-uplink | ? | ? | ? | ? | 3016.11 | u48
- yul1-11-lf-tor-switch | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u47
- mtl1-6-7050QX-32 | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u46
- fdio-marvell-dev | up | N/A | dev | ThunderX-88XX | N/A | 10.30.51.38 | 10.30.50.38 | 3016.11 | u45
- s21-nomad | up | nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50150 | 10.30.51.21 | 10.30.50.21 | 3016.11 | u39-u42
- s22-nomad | up | nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50155 | 10.30.51.22 | 10.30.50.22 | 3016.11 | u35-u38
- s78-t38-sut1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50450 | 10.30.51.78 | 10.30.50.78 | 3016.11 | u31-u34
- s79-t38-sut2 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL07P50297 | 10.30.51.79 | 10.30.50.79 | 3016.11 | u27-u30
- s80-t38-tg1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50454 | 10.30.51.80 | 10.30.50.80 | 3016.11 | u23-u26
- s30-t15-sut1 | up | nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50154 | 10.30.51.30 | 10.30.50.30 | 3016.11 | u19-u22
- s31-t16-sut1 | up | nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50149 | 10.30.51.31 | 10.30.50.31 | 3016.11 | u15-u18
- s56-t14-sut1 | up | t14 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.71 | 10.30.50.71 | 3016.11 | u13-u14
- s55-t13-sut1 | up | t13 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.70 | 10.30.50.70 | 3016.11 | u11-u12
- s62-t34-sut1 | up | t34 | 3n-alt | WIWYNN | 04000059N0SC | 10.30.51.72 | 10.30.50.72 | 3016.11 | u9-u10
- s63-t34-sut2 | up | t34 | 3n-alt | WIWYNN | 0390003EN0SC | 10.30.51.73 | 10.30.50.73 | 3016.11 | u7-u8
- s64-t34-tg1 | up | t34 | 3n-alt | SYS-740GP-TNRT | C7470KK40P50249 | 10.30.51.74 | 10.30.50.74 | 3016.11 | u3-u6
+ **name** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------------|--------------|----------------|-----------------|--------------|--------------|------------|--------------
+ yul1-11-lb6m | arm-uplink | ? | ? | ? | ? | 3016.11 | u48
+ yul1-11-lf-tor-switch | uplink | ? | ? | ? | ? | 3016.11 | u47
+ mtl1-6-7050QX-32 | uplink | ? | ? | ? | ? | 3016.11 | u46
+ fdio-marvell-dev | dev | ThunderX-88XX | N/A | 10.30.51.38 | 10.30.50.38 | 3016.11 | u45
+ s21-nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50150 | 10.30.51.21 | 10.30.50.21 | 3016.11 | u39-u42
+ s22-nomad | nomad-client | SYS-741GE-TNRT | C7490FL47A50155 | 10.30.51.22 | 10.30.50.22 | 3016.11 | u35-u38
+ s78-t38-sut1 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50450 | 10.30.51.78 | 10.30.50.78 | 3016.11 | u31-u34
+ s79-t38-sut2 | 3n-icx | SYS-740GP-TNRT | C7470KL07P50297 | 10.30.51.79 | 10.30.50.79 | 3016.11 | u27-u30
+ s80-t38-tg1 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50454 | 10.30.51.80 | 10.30.50.80 | 3016.11 | u23-u26
+ s30-t15-sut1 | nomad-client | SYS-741GE-TNRT | C7490FL47A50154 | 10.30.51.30 | 10.30.50.30 | 3016.11 | u19-u22
+ s31-t16-sut1 | nomad-client | SYS-741GE-TNRT | C7490FL47A50149 | 10.30.51.31 | 10.30.50.31 | 3016.11 | u15-u18
+ s56-t14-sut1 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.71 | 10.30.50.71 | 3016.11 | u13-u14
+ s55-t13-sut1 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.70 | 10.30.50.70 | 3016.11 | u11-u12
+ s62-t34-sut1 | 3n-alt | WIWYNN | 04000059N0SC | 10.30.51.72 | 10.30.50.72 | 3016.11 | u9-u10
+ s63-t34-sut2 | 3n-alt | WIWYNN | 0390003EN0SC | 10.30.51.73 | 10.30.50.73 | 3016.11 | u7-u8
+ s64-t34-tg1 | 3n-alt | SYS-740GP-TNRT | C7470KK40P50249 | 10.30.51.74 | 10.30.50.74 | 3016.11 | u3-u6
### Rack YUL1-12 (3016.12)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
----------------|-----------------|----------------|----------------|-----------------|-----------------|--------------|--------------|------------|--------------
- yul1-12-lb4m | up | switch | uplink | ? | ? | ? | ? | 3016.12 | u47
- s28-nomad | up | nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20196 | 10.30.51.28 | 10.30.50.28 | 3016.12 | u41-u44
- s27-nomad | up | nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20055 | 10.30.51.27 | 10.30.50.27 | 3016.12 | u37-u40
- s91-nomad | up | nomad | nomad-client | R152-P30-00 | GLG4P9912A0016 | 10.30.51.91 | 10.30.50.91 | 3016.12 | u36
- s92-nomad | up | nomad | nomad-client | R152-P30-00 | GLG4P9912A0004 | 10.30.51.92 | 10.30.50.92 | 3016.12 | u35
- s23-nomad | up | nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0256 | 10.30.51.23 | 10.30.51.23 | 3016.12 | u34
- s24-nomad | up | nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0241 | 10.30.51.24 | 10.30.51.24 | 3016.12 | u33
- s25-nomad | up | nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0540 | 10.30.51.25 | 10.30.51.25 | 3016.12 | u32
- s61-t210-tg1 | up | t210 | 2n-zn2 | AS-1014S-WTRT | C8150LI50NS2689 | 10.32.8.25 | 10.30.55.25 | 3016.12 | u31
- s60-t210-sut1 | up | t210 | 2n-zn2 | AS-1114S-WTRT | N/A | 10.32.8.24 | 10.30.55.24 | 3016.12 | u30
- s26-nomad | up | nomad | nomad-server | SYS-7049GP-TRT | C7470KH37A30505 | 10.30.51.26 | 10.30.51.26 | 3016.12 | u26-u29
- s33-t27-sut1 | up | t27 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30567 | 10.32.8.18 | 10.30.55.18 | 3016.12 | u22-u25
- s34-t27-tg1 | up | t27 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30565 | 10.32.8.19 | 10.30.55.19 | 3016.12 | u18-u21
- s35-t28-sut1 | up | t28 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30509 | 10.32.8.20 | 10.30.55.20 | 3016.12 | u14-u17
- s36-t28-tg1 | up | t28 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30511 | 10.32.8.21 | 10.30.55.21 | 3016.12 | u10-u13
- s37-t29-sut1 | up | t29 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30566 | 10.32.8.22 | 10.30.55.22 | 3016.12 | u6-u9
- s38-t29-tg1 | up | t29 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30506 | 10.32.8.23 | 10.30.55.23 | 3016.12 | u2-u5
+ **name** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------|---------------|---------------------|-----------------|--------------|--------------|------------|--------------
+ yul1-12-lb4m | uplink | ? | ? | ? | ? | 3016.12 | u47
+ s28-nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20196 | 10.30.51.28 | 10.30.50.28 | 3016.12 | u41-u44
+ s27-nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20055 | 10.30.51.27 | 10.30.50.27 | 3016.12 | u37-u40
+ s91-nomad | nomad-client | R152-P30-00 | GLG4P9912A0016 | 10.30.51.91 | 10.30.50.91 | 3016.12 | u36
+ s92-nomad | nomad-client | R152-P30-00 | GLG4P9912A0004 | 10.30.51.92 | 10.30.50.92 | 3016.12 | u35
+ s23-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0256 | 10.30.51.23 | 10.30.51.23 | 3016.12 | u34
+ s24-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0241 | 10.30.51.24 | 10.30.51.24 | 3016.12 | u33
+ s25-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0540 | 10.30.51.25 | 10.30.51.25 | 3016.12 | u32
+ s61-t210-tg1 | 2n-zn2 | AS-1014S-WTRT | C8150LI50NS2689 | 10.32.8.25 | 10.30.55.25 | 3016.12 | u31
+ s60-t210-sut1 | 2n-zn2 | AS-1114S-WTRT | N/A | 10.32.8.24 | 10.30.55.24 | 3016.12 | u30
+ s26-nomad | nomad-server | SYS-7049GP-TRT | C7470KH37A30505 | 10.30.51.26 | 10.30.51.26 | 3016.12 | u26-u29
+ s33-t27-sut1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30567 | 10.32.8.18 | 10.30.55.18 | 3016.12 | u22-u25
+ s34-t27-tg1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30565 | 10.32.8.19 | 10.30.55.19 | 3016.12 | u18-u21
+ s35-t28-sut1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30509 | 10.32.8.20 | 10.30.55.20 | 3016.12 | u14-u17
+ s36-t28-tg1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30511 | 10.32.8.21 | 10.30.55.21 | 3016.12 | u10-u13
+ s37-t29-sut1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30566 | 10.32.8.22 | 10.30.55.22 | 3016.12 | u6-u9
+ s38-t29-tg1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30506 | 10.32.8.23 | 10.30.55.23 | 3016.12 | u2-u5