diff options
author | Vratko Polak <vrpolak@cisco.com> | 2024-05-20 17:01:11 +0200 |
---|---|---|
committer | Vratko Polak <vrpolak@cisco.com> | 2024-05-20 17:01:11 +0200 |
commit | 55bdf4cc0046617100676685d1f5ef075167af1d (patch) | |
tree | ffefa62b316881619047bba77ebf5e5e54d8ac86 | |
parent | c5d1ec293164a5aad9b04a7df749b85c2ef01582 (diff) |
fix(perf): Increase threshold for jumbo
The old limit of 1522 was introduced long time ago.
First, it appeared here [0], where it is correct
as that suite has zero overhead.
The first suite with wrong logic seems to be here [1]
(no "Add No Multi Seg to all DUTs" in 1518B testcase).
And when I was moving that logic to a keyword in [2],
I did not realize it is wrong with overhead.
This Change uses 1800 as the new threshold,
matching the value used for non-jumbo MTU.
[0] https://gerrit.fd.io/r/c/csit/+/2652/12/tests/perf/Bridge_Domain_Intel-X520-DA2.robot#70
[1] https://gerrit.fd.io/r/c/csit/+/4454/96/tests/perf/40ge2p1xl710-ethip4ipsecscaleip4-ip4base-interfaces-aes-gcm-ndrpdrdisc.robot#229
[2] https://gerrit.fd.io/r/c/csit/+/13411/35/resources/libraries/robot/performance/performance_utils.robot#84
Change-Id: Iff3703fcff0e4bbb1a6b10be359fa5ef67fd5422
Signed-off-by: Vratko Polak <vrpolak@cisco.com>
-rw-r--r-- | resources/libraries/robot/performance/performance_vars.robot | 4 |
1 files changed, 2 insertions, 2 deletions
diff --git a/resources/libraries/robot/performance/performance_vars.robot b/resources/libraries/robot/performance/performance_vars.robot index a0fa277e4c..1bab1071b7 100644 --- a/resources/libraries/robot/performance/performance_vars.robot +++ b/resources/libraries/robot/performance/performance_vars.robot @@ -1,4 +1,4 @@ -# Copyright (c) 2023 Cisco and/or its affiliates. +# Copyright (c) 2024 Cisco and/or its affiliates. # Licensed under the Apache License, Version 2.0 (the "License"); # you may not use this file except in compliance with the License. # You may obtain a copy of the License at: @@ -413,7 +413,7 @@ | | | | # Some suites (e.g. device) are not calling Set Max Rate And Jumbo. | | Set Numeric Frame Sizes -| | ${jumbo} = | Evaluate | ${max_frame_size} >= 1522 +| | ${jumbo} = | Evaluate | ${max_frame_size} >= 1800 | | Set Test Variable | \${jumbo} | | ${recommended_mtu} = | Set Variable If | ${jumbo} | ${9200} | ${1800} | | Set Test Variable | \${recommended_mtu} |