diff options
author | pmikus <peter.mikus@protonmail.ch> | 2023-06-06 08:09:22 +0000 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2023-06-06 08:11:18 +0000 |
commit | 120b5c0f3035985170ee27c001c29766c050684f (patch) | |
tree | c98500cbe1904a69a6e17fca1a9c32bba28fe0b2 | |
parent | 64dbeaadfb456bafaf1b9560858f4cbd2759abdb (diff) |
docs(infra): Fixing typos
Signed-off-by: pmikus <peter.mikus@protonmail.ch>
Change-Id: Ibbe8a346f9c1b9beb5ffa5a6b6029ad9153b9c9f
(cherry picked from commit 0f6e249b9fea466fe78bb37c847a7bc4f03c2fc5)
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 32 |
1 files changed, 16 insertions, 16 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index bbc487fcd6..164e348bd1 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -1262,8 +1262,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s62-t34-sut1-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE. + - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. @@ -1272,8 +1272,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s63-t34-sut2-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE. + - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-E32]: - testbedname: testbed34. - hostname: s64-t34-tg1. @@ -1312,7 +1312,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed37. - hostname: s66-t37-sut2. @@ -1328,7 +1328,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed37. - hostname: s67-t37-tg1. @@ -1344,7 +1344,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s67-t37-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s67-t37-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s67-t37-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT1 [Server-Type-F3]: - testbedname: testbed38. - hostname: s78-t38-sut1. @@ -1360,7 +1360,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s78-t38-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s78-t38-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s78-t38-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed38. - hostname: s79-t38-sut2. @@ -1376,7 +1376,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s79-t38-sut2-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s79-t38-sut2-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s79-t38-sut2-c6/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed38. - hostname: s80-t38-tg1. @@ -1392,7 +1392,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s80-t38-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s80-t38-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s80-t38-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. ``` ### 3-Node-SnowRidge (3n-snr) @@ -1740,7 +1740,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1. - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2. - testbed213: @@ -1758,7 +1758,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1. - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2. - testbed214: @@ -1776,7 +1776,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1. - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2. - testbed215: @@ -1794,7 +1794,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1. - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2. ``` @@ -1852,7 +1852,7 @@ To be completed. - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. - - ring4 100GE-ports ConnectX6-2p100GE: + - ring4 200GE-ports ConnectX6-2p200GE: - s67-t37-tg1-c6/p1 - s65-t37-sut1-c6/p2. - s65-t37-sut1-c6/p1 - s66-t37-sut2-c6/p2. - s66-t37-sut2-c6/p1 - s67-t37-tg1-c9-c6/p2. @@ -1872,7 +1872,7 @@ To be completed. - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. - - ring4 100GE-ports ConnectX6-2p100GE: + - ring4 200GE-ports ConnectX6-2p200GE: - s80-t38-tg1-c6/p1 to s78-t38-sut1-c6/p1. - s78-t38-sut1-c6/p2 to s79-t38-sut2-c6/p2. - s79-t38-sut2-c6/p1 to s80-t38-tg1-c6/p2. |