diff options
author | pmikus <peter.mikus@protonmail.ch> | 2023-03-27 11:02:38 +0000 |
---|---|---|
committer | pmikus <peter.mikus@protonmail.ch> | 2023-03-27 11:02:38 +0000 |
commit | 12992a674d186f437bd29b854c0031a092097def (patch) | |
tree | 80d43dc013362690a291e69612ec2d258bf1a6c0 /docs/content/infrastructure/fdio_csit_testbed_specifications.md | |
parent | 9e86c76e6f2dbd7094f2f4b32b40eb6aa53adc8a (diff) |
feat(docs): Update Infrastructure
Signed-off-by: pmikus <peter.mikus@protonmail.ch>
Change-Id: I0044e305dfe3fbd76f0e0f0f261e107b0f134650
Diffstat (limited to 'docs/content/infrastructure/fdio_csit_testbed_specifications.md')
-rw-r--r-- | docs/content/infrastructure/fdio_csit_testbed_specifications.md | 221 |
1 files changed, 119 insertions, 102 deletions
diff --git a/docs/content/infrastructure/fdio_csit_testbed_specifications.md b/docs/content/infrastructure/fdio_csit_testbed_specifications.md index 49b6d72fa9..0711477a26 100644 --- a/docs/content/infrastructure/fdio_csit_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_csit_testbed_specifications.md @@ -11,6 +11,30 @@ weight: 2 This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project. +## Server Management + +### Addressing + +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a +Management port, which are connected to two different VLANs. + +#### LOM (IPMI) VLAN + + - Subnet: 10.30.50.0/24 + - Gateway: 10.30.50.1 + - Broadcast: 10.30.50.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 + +#### Management VLAN + - Subnet: 10.30.51.0/24 + - Gateway: 10.30.51.1 + - Broadcast: 10.30.51.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 + +To access these hosts, VPN connection is required. + ## Testbeds Overview ### Summary List @@ -139,37 +163,31 @@ one TG (Server-Type-H6) connected in a 2-node circular topology. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). Used for FD.io performance tests. -## Server Management - -### Addressing -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a -Management port, which are connected to two different VLANs. - -``` -1. LOM (IPMI) VLAN: - - Subnet: 10.30.50.0/24 - - Gateway: 10.30.50.1 - - Broadcast: 10.30.50.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -2. Management Vlan: - - Subnet: 10.30.51.0/24 - - Gateway: 10.30.51.1 - - Broadcast: 10.30.51.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -``` +## Tesdtbed Naming Convention -To access these hosts, VPN connection is required. +Following naming convention is used within this page to specify physical +connectivity and wiring across defined CSIT testbeds: -## Server Specifications +- **testbedname**: testbedN. +- **hostname**: + - traffic-generator: tN-tgW. + - system-under-testX: tN-sutX. +- **portnames**: + - tN-tgW-cY/pZ. + - tN-sutX-cY/pZ. +- **where**: + - N - testbed number. + - tgW - server acts as traffic-generator with W index. + - sutX - server acts as system-under-test with X index. + - Y - PCIe slot number denoting a NIC card number within the host. + - Z - port number on the NIC card. -### Server Types +## Server Types FD.io CSIT lab contains following server types: -``` -1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing. + +1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -188,7 +206,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. + +2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -208,7 +227,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. + +3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -227,7 +247,8 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. + +4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -267,7 +288,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. + +6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. @@ -287,7 +309,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. + +7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -307,7 +330,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot10 d8:00.xx: empty. -8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + +8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -323,7 +347,8 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. -9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. + +9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -338,7 +363,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. + +10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -353,7 +379,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. -11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + +11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -371,7 +398,8 @@ FD.io CSIT lab contains following server types: - Numa1: - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. -12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + +12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. @@ -384,7 +412,8 @@ FD.io CSIT lab contains following server types: - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. + +13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -400,7 +429,8 @@ FD.io CSIT lab contains following server types: - no cards - Numa1: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. + +14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -417,7 +447,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - Numa1: - no cards. -15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. +15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -428,7 +458,8 @@ FD.io CSIT lab contains following server types: - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - RAM Memory: 12* 16GB DDR4-3200MT/s - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + +16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -448,7 +479,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. + +17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 8. - Physical connectivity: - IPMI and host management ports. @@ -468,7 +500,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. + +18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -488,7 +521,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. + +19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -508,7 +542,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -528,7 +562,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. -21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. + +21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -542,7 +577,8 @@ FD.io CSIT lab contains following server types: - NICs configuration: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. + +22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -562,7 +598,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. + +23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -582,7 +619,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. -24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. + +24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -602,7 +640,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. -25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing. + +25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -622,7 +661,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: empty. - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. + +26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -642,7 +682,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: empty. - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing. + +27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -662,34 +703,10 @@ FD.io CSIT lab contains following server types: - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot11 d8:00.xx: empty. -``` - -### Naming Convention - -Following naming convention is used within this page to specify physical -connectivity and wiring across defined CSIT testbeds: - -``` -- testbedname: testbedN. -- hostname: - - traffic-generator: tN-tgW. - - system-under-testX: tN-sutX. -- portnames: - - tN-tgW-cY/pZ. - - tN-sutX-cY/pZ. -- where: - - N - testbed number. - - tgW - server acts as traffic-generator with W index. - - sutX - server acts as system-under-test with X index. - - Y - PCIe slot number denoting a NIC card number within the host. - - Z - port number on the NIC card. -``` ## Testbeds Configuration -### Per Testbed Server Allocation and Naming - -#### 1-Node-Skylake Servers (1n-skx) PROD +### 1-Node-Skylake (1n-skx) ``` - SUT [Server-Type-B6]: @@ -722,7 +739,7 @@ connectivity and wiring across defined CSIT testbeds: - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 1-Node-ThunderX2 Servers (1n-tx2) PROD +### 1-Node-ThunderX2 (1n-tx2) ``` - SUT [Server-Type-E11]: @@ -755,7 +772,7 @@ connectivity and wiring across defined CSIT testbeds: - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` -#### 1-Node-Cascadelake Servers (1n-clx) PROD +### 1-Node-Cascadelake (1n-clx) ``` - SUT [Server-Type-C1]: @@ -774,7 +791,7 @@ connectivity and wiring across defined CSIT testbeds: - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY +### 2-Node-IxiaPS1L47 (2n-ps1) ``` - SUT [Server-Type-B8]: @@ -799,7 +816,7 @@ connectivity and wiring across defined CSIT testbeds: - s26-t25-tg1-p4 - 10GE-port4. ``` -#### 2-Node-Cascadelake Servers (2n-clx) PROD +### 2-Node-Cascadelake (2n-clx) {{< figure src="/cdocs/testbed-2n-clx.svg" >}} @@ -906,7 +923,7 @@ connectivity and wiring across defined CSIT testbeds: - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. ``` -#### 2-Node-Zen2 Servers (2n-zn2) PROD +### 2-Node-Zen2 (2n-zn2) {{< figure src="/cdocs/testbed-2n-zn2.svg" >}} @@ -941,7 +958,7 @@ connectivity and wiring across defined CSIT testbeds: - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` -#### 2-Node-ThunderX2 Servers (2x-tx2) PROD +### 2-Node-ThunderX2 (2x-tx2) {{< figure src="/cdocs/testbed-2n-tx2.svg" >}} @@ -974,7 +991,7 @@ connectivity and wiring across defined CSIT testbeds: - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -#### 2-Node-Icelake Servers (2n-icx) PROD +### 2-Node-Icelake (2n-icx) {{< figure src="/cdocs/testbed-2n-icx.svg" >}} @@ -1101,7 +1118,7 @@ connectivity and wiring across defined CSIT testbeds: - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -#### 3-Node-Rangeley Servers (3n-rng) VERIFY +### 3-Node-Rangeley (3n-rng) Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. @@ -1135,7 +1152,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - 1GB ports (tbd) ``` -#### 3-Node-Taishan Servers (3n-tsh) PROD +### 3-Node-Taishan (3n-tsh) {{< figure src="/cdocs/testbed-3n-tsh.svg" >}} @@ -1180,7 +1197,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -#### 3-Node-Altra Servers (3n-alt) PROD +### 3-Node-Altra (3n-alt) {{< figure src="/cdocs/testbed-3n-alt.svg" >}} @@ -1219,7 +1236,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -#### 3-Node-Icelake Servers (3n-icx) PROD +### 3-Node-Icelake (3n-icx) {{< figure src="/cdocs/testbed-3n-icx.svg" >}} @@ -1310,7 +1327,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -#### 3-Node-SnowRidge Servers (3n-snr) PROD +### 3-Node-SnowRidge (3n-snr) {{< figure src="/cdocs/testbed-3n-snr.svg" >}} @@ -1347,7 +1364,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. ``` -#### 2-Node-SapphireRapids Servers (2n-spr) PROD +### 2-Node-SapphireRapids (2n-spr) {{< figure src="/cdocs/testbed-2n-spr.svg" >}} @@ -1482,9 +1499,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -### Per Testbed Wiring +## Testbed Wiring -#### 1-Node-Skylake Wiring (1n-skx) PROD +### 1-Node-Skylake (1n-skx) ``` - testbed11: @@ -1515,7 +1532,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. ``` -#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD +### 1-Node-ThunderX2 (1n-tx2) ``` - testbed13: @@ -1539,7 +1556,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` -#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY +### 2-Node-IxiaPS1L47 (2n-ps1) ``` - testbed25: @@ -1553,7 +1570,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - t25-tg1-p4 to t25-sut1-c2/p4. ``` -#### 2-Node-Cascadelake Wiring (2n-clx) PROD +### 2-Node-Cascadelake (2n-clx) ``` - testbed27: @@ -1612,7 +1629,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. ``` -#### 2-Node-Zen2 Wiring (2n-zn2) PROD +### 2-Node-Zen2 (2n-zn2) ``` - testbed210: @@ -1630,7 +1647,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. ``` -#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD +### 2-Node-ThunderX2 (2n-tx2) ``` - testbed211: @@ -1639,7 +1656,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. ``` -#### 2-Node-Icelake Wiring (2n-icx) PROD +### 2-Node-Icelake (2n-icx) ``` - testbed212: @@ -1704,13 +1721,13 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. ``` -#### 3-Node-Rangeley Wiring (3n-rng) VERIFY +### 3-Node-Rangeley (3n-rng) ``` To be completed. ``` -#### 3-Node-Taishan Wiring (3n-tsh) PROD +### 3-Node-Taishan (3n-tsh) ``` - testbed33: @@ -1724,7 +1741,7 @@ To be completed. - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. ``` -#### 3-Node-Altra Wiring (3n-alt) PROD +### 3-Node-Altra (3n-alt) ``` - testbed34: @@ -1734,7 +1751,7 @@ To be completed. - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. ``` -#### 3-Node-Icelake Wiring (3n-icx) PROD +### 3-Node-Icelake (3n-icx) ``` - testbed37: @@ -1771,7 +1788,7 @@ To be completed. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. ``` -#### 3-Node-SnowRidge Wiring (3n-snr) PROD +### 3-Node-SnowRidge (3n-snr) ``` - testbed39: @@ -1784,7 +1801,7 @@ To be completed. - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. ``` -#### 2-Node-SapphireRapids Wiring (2n-spr) PROD +### 2-Node-SapphireRapids (2n-spr) ``` - testbed21: |