diff options
author | pmikus <peter.mikus@protonmail.ch> | 2023-09-05 08:26:26 +0000 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2023-09-06 08:37:48 +0000 |
commit | 4f69b1cbe4e3edb2ca5d6f10d6dae2a0a1fadcb2 (patch) | |
tree | 9b09a2e3d2cb9e820ebe0b517b46498978ac4af0 /docs/content/infrastructure/fdio_dc_testbed_specifications.md | |
parent | 9e28d41817b4f1b3a77a4c65d76da9d292fd9d8a (diff) |
feat(infra): Add new SPR servers
Signed-off-by: pmikus <peter.mikus@protonmail.ch>
Change-Id: Id90ca8323e6f49b51f19526e1089bf711e4e8182
Diffstat (limited to 'docs/content/infrastructure/fdio_dc_testbed_specifications.md')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 85 |
1 files changed, 80 insertions, 5 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 0e9f8ba2b8..3df698ac0d 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -19,7 +19,6 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. #### LOM (IPMI) VLAN - - Subnet: 10.30.50.0/24 - Gateway: 10.30.50.1 - Broadcast: 10.30.50.255 @@ -54,8 +53,9 @@ To access these hosts, VPN connection is required. 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 -13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 - Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 +14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 +15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 + Totals: 32 39 18.5 7 1 2 1 2 4 7 2 15.5 2 12 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -70,6 +70,12 @@ Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. +### 1-Node-Skylake Xeon Intel (1n-spr) + +Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + ### 1-Node-Cascadelake Xeon Intel (1n-clx) Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with @@ -215,8 +221,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. @@ -740,6 +746,27 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot11 d8:00.xx: empty. +30. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. + ## Testbeds Configuration ### 1-Node-Skylake (1n-skx) @@ -759,6 +786,10 @@ FD.io CSIT lab contains following server types: - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. + - s1-t11-sut1-c5/p1 - 100GE-port1 e810-2p100GE. + - s1-t11-sut1-c5/p2 - 100GE-port2 e810-2p100GE. + - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - SUT [Server-Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. @@ -773,6 +804,10 @@ FD.io CSIT lab contains following server types: - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. + - s2-t12-sut1-c5/p1 - 100GE-port1 e810-2p100GE. + - s2-t12-sut1-c5/p2 - 100GE-port2 e810-2p100GE. + - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE. ``` ### 1-Node-ThunderX2 (1n-tx2) @@ -808,6 +843,31 @@ FD.io CSIT lab contains following server types: - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` +### 1-Node-SapphireRapids (1n-spr) + +``` +- SUT [Server-Type-H7]: + - testbedname: testbed15. + - hostname: s30-t15-sut1. + - IPMI IP: 10.30.50.30 + - Host IP: 10.30.51.31 + - portnames: + - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2p100GE. + - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2p100GE. + - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2p100GE. + - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2p100GE. +- SUT [Server-Type-H7]: + - testbedname: testbed16. + - hostname: s31-t16-sut1. + - IPMI IP: 10.30.50.31 + - Host IP: 10.30.51.31 + - portnames: + - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2p100GE. + - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2p100GE. + - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2p100GE. + - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2p100GE. +``` + ### 1-Node-Cascadelake (1n-clx) ``` @@ -1622,6 +1682,21 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` +### 1-Node-SapphireRapids (1n-spr) + +``` +- testbed15: + - ring1 100GE-ports e810-2p100GE: + - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1. + - ring2 100GE-ports e810-2p100GE: + - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2. +- testbed16: + - ring1 100GE-ports e810-2p100GE: + - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1. + - ring2 100GE-ports e810-2p100GE: + - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2. +``` + ### 2-Node-IxiaPS1L47 (2n-ps1) ``` |