diff options
author | Tibor Frank <tifrank@cisco.com> | 2023-05-03 13:53:27 +0000 |
---|---|---|
committer | Tibor Frank <tifrank@cisco.com> | 2023-05-09 05:56:22 +0000 |
commit | 374954b9d648f503f6783325a1266457953a998d (patch) | |
tree | 5514dee6af2a2e069189efe39d4e929dd25721f7 /docs/content/infrastructure/fdio_dc_testbed_specifications.md | |
parent | 46eac7bb697e8261dba5b439a15f5a6125f31760 (diff) |
C-Docs: New structure
Change-Id: I73d107f94b28b138f3350a9e1eedb0555583a9ca
Signed-off-by: Tibor Frank <tifrank@cisco.com>
Diffstat (limited to 'docs/content/infrastructure/fdio_dc_testbed_specifications.md')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 1861 |
1 files changed, 1861 insertions, 0 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md new file mode 100644 index 0000000000..3daa3824e2 --- /dev/null +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -0,0 +1,1861 @@ +--- +bookToc: true +title: "FD.io DC Testbed Specifications" +weight: 2 +--- + +# FD.io DC Testbed Specifications + +## Purpose + +This note includes specification of the physical testbed infrastructure +hosted by LFN FD.io CSIT project. + +## Server Management + +### Addressing + +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a +Management port, which are connected to two different VLANs. + +#### LOM (IPMI) VLAN + + - Subnet: 10.30.50.0/24 + - Gateway: 10.30.50.1 + - Broadcast: 10.30.50.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 + +#### Management VLAN + - Subnet: 10.30.51.0/24 + - Gateway: 10.30.51.1 + - Broadcast: 10.30.51.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 + +To access these hosts, VPN connection is required. + +## Testbeds Overview + +### Summary List + +``` + #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr + 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 + 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 + 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 + 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 + 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 + 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 + 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 + 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 +10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 +11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 +12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 +13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 +13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 + Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 +``` + +### 1-Node-Skylake Xeon Intel (1n-skx) + +Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-ThunderX2 Arm Marvell (1n-tx2) + +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-Cascadelake Xeon Intel (1n-clx) + +Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with +NIC ports connected back-to-back ([Server Types](#server-types)). + +Used for FD.io VPP_Device functional driver tests. + +### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) + +Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one +TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node +circular topology ([Server Types](#server-types)). +Used for FD.io TCP/IP and HTTP performance tests. + +### 2-Node-Cascadelake Xeon Intel (2n-clx) + +Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and +one TG (Server-Type-C3) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Zen2 EPYC AMD (2n-zn2) + +Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and +one TG (Server-Type-D2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-ThunderX2 Arm Marvell (2x-tx2) + +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and +one TG (Server-Type-E31) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Icelake Xeon Intel (2n-icx) + +Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and +one TG (Server-Type-F2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Rangeley Atom Testbeds + +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-TaiShan Arm Huawei (3n-tsh) + +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one +TG (Server-Type-E31) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Altra Arm Ampere (3n-alt) + +Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Icelake Xeon Intel (3n-icx) + +Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one +TG (Server-Type-F3) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-SnowRidge Atom Intel (3n-snr) + +Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) + +One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and +one TG (Server-Type-H2) connected in a 2-node physical topology +with NUMA (socket) daisy chaining. For more detail see +[Server Types](#server-types) and [Testbed Topology-TODO](#TODO). +Used for FD.io performance tests in a full system SUT setup with all PCIe +Gen5 x16 lane slots populated with 2p200GbE NICs. + +### 2-Node-SapphireRapids Xeon Intel (2n-spr) + +Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and +one TG (Server-Type-H6) connected in a 2-node circular topology. For more +detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). +Used for FD.io performance tests. + + +## Tesdtbed Naming Convention + +Following naming convention is used within this page to specify physical +connectivity and wiring across defined CSIT testbeds: + +- **testbedname**: testbedN. +- **hostname**: + - traffic-generator: tN-tgW. + - system-under-testX: tN-sutX. +- **portnames**: + - tN-tgW-cY/pZ. + - tN-sutX-cY/pZ. +- **where**: + - N - testbed number. + - tgW - server acts as traffic-generator with W index. + - sutX - server acts as system-under-test with X index. + - Y - PCIe slot number denoting a NIC card number within the host. + - Z - port number on the NIC card. + +## Server Types + +FD.io CSIT lab contains following server types: + +1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: empty. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. + - Quantity: 1. + - Physical connectivity: + - Host management interface: 10/100/1000-BaseT. + - 8-port 10GE SFP+ integrated NIC. + - Main HW configuration: + - Chassis: PS10GE4NG. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: Quad-Core, Intel Processor. + - HW accelerators: FPGA offload. + - RAM Memory: 64GB. + - Disks: 1 * 1 TB, Enterprise Class, High MTBF. + - Physical Interfaces: 4 * 10GE SFP+. + - Operating System: Native IxOS. + - Interface configuration: + - Port-1: 10GE SFP+. + - Port-2: 10GE SFP+. + - Port-3: 10GE SFP+. + - Port-4: 10GE SFP+. + +4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing. + - Quantity: 3 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Gold 6252N 2.3 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot10 d8:00.xx: empty. + +8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - no NIC ports, standalone setup. + - Main HW configuration: + - Chassis: SuperMicro 1029P-WTRT. + - Motherboard: SuperMicro X11DDW-NT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 4* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: + - no cards. + - Numa1: + - no cards. + +9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: x710-4p10GE Intel. + - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + +10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot2 41:00.xx: x710-4p10GE Intel. + - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. + +11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: GIGABYTE Rack Mount + - Motherboard: MT91-FS4-00 + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz + - RAM Memory: 16 * 16GB DIMM + - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - NICs configuration: + - Numa0: + - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. + +12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slot6 11:00.xx: x520-2p10GE Intel. + +13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node topologies. + - Main HW configuration: + - Chassis: Gigabyte R181-T90 1U + - Motherboard: MT91-FS1 + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - NICs configuration: + - Numa0: + - no cards + - Numa1: + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. + +14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node topologies. + - Main HW configuration: + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Motherboard: Mt.Jade Motherboard + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 + - NICs configuration: + - Numa0: + - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. + - Numa1: + - no cards. +15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 + +16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. + +17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. + - Quantity: 8. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 d8:00.xx: empty. + +21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topology. + - Main HW configuration: + - Chassis: Intel JACOBSVILLE SDP. + - Motherboard: Intel JACOBSVILLE E63448-400. + - Processors: 1* Intel Atom P5362B 2.2 GHz. + - RAM Memory: 2* 16GB DDR4-2933. + - Disks: ?* ? SATA SSD. + - NICs configuration: + - Numa0: (x16, PCIe3.0 lane) + - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. + +22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-numa-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + +23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-numa-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot11 d8:00.xx: empty. + +24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-numa-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot10 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot11 d8:00.xx: empty. + +25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-numa-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot10 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. + +26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. + +27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot11 d8:00.xx: empty. + +## Testbeds Configuration + +### 1-Node-Skylake (1n-skx) + +``` +- SUT [Server-Type-B6]: + - testbedname: testbed11. + - hostname: s1-t11-sut1. + - IPMI IP: 10.30.50.47 + - Host IP: 10.30.51.50 + - portnames: + - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +- SUT [Server-Type-B6]: + - testbedname: testbed12. + - hostname: s2-t12-sut1. + - IPMI IP: 10.30.50.48 + - Host IP: 10.30.51.51 + - portnames: + - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + +### 1-Node-ThunderX2 (1n-tx2) + +``` +- SUT [Server-Type-E11]: + - testbedname: testbed13 + - hostname: s55-t13-sut1 + - IPMI IP: 10.30.50.70 + - Host IP: 10.30.51.70 + - portnames: + - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-E11]: + - testbedname: testbed14 + - hostname: s56-t14-sut1 + - IPMI IP: 10.30.50.71 + - Host IP: 10.30.51.71 + - portnames: + - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +``` + +### 1-Node-Cascadelake (1n-clx) + +``` +- SUT [Server-Type-C1]: + - testbedname: testbed11. + - hostname: s32-t14-sut1. + - IPMI IP: 10.30.55.17 + - Host IP: 10.32.8.17 + - portnames: + - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + +### 2-Node-IxiaPS1L47 (2n-ps1) + +``` +- SUT [Server-Type-B8]: + - testbedname: testbed25. + - hostname: s25-t25-sut1. + - IPMI IP: 10.30.50.58 + - Host IP: 10.30.51.61 + - portnames: + - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. +- TG [Server-Type-B7]: + - testbedname: testbed25. + - hostname: s26-t25-tg1. + - IPMI IP: 10.30.50.59 + - Host IP: 10.30.51.62 + - portnames: + - s26-t25-tg1-p1 - 10GE-port1. + - s26-t25-tg1-p2 - 10GE-port2. + - s26-t25-tg1-p3 - 10GE-port3. + - s26-t25-tg1-p4 - 10GE-port4. +``` + +### 2-Node-Cascadelake (2n-clx) + +{{< figure src="/cdocs/testbed-2n-clx.svg" >}} + +``` +- SUT [Server-Type-C2]: + - testbedname: testbed27. + - hostname: s33-t27-sut1. + - IPMI IP: 10.30.55.18 + - Host IP: 10.32.8.18 + - portnames: + - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed27. + - hostname: s34-t27-tg1. + - IPMI IP: 10.30.55.19 + - Host IP: 10.32.8.19 + - portnames: + - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed28. + - hostname: s35-t28-sut1. + - IPMI IP: 10.30.55.20 + - Host IP: 10.32.8.20 + - portnames: + - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed28. + - hostname: s36-t28-tg1. + - IPMI IP: 10.30.55.21 + - Host IP: 10.32.8.21 + - portnames: + - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed29. + - hostname: s37-t29-sut1. + - IPMI IP: 10.30.55.22 + - Host IP: 10.32.8.22 + - portnames: + - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed29. + - hostname: s38-t29-tg1. + - IPMI IP: 10.30.55.23 + - Host IP: 10.32.8.23 + - portnames: + - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +``` + +### 2-Node-Zen2 (2n-zn2) + +{{< figure src="/cdocs/testbed-2n-zn2.svg" >}} + +``` +- SUT [Server-Type-D1]: + - testbedname: testbed210. + - hostname: s60-t210-sut1. + - IPMI IP: 10.30.55.24 + - Host IP: 10.32.8.24 + - portnames: + - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. + - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. + - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. + - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. + - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. + - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-D2]: + - testbedname: testbed210. + - hostname: s61-t210-tg1. + - IPMI IP: 10.30.55.25 + - Host IP: 10.32.8.25 + - portnames: + - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. + - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. + - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. +``` + +### 2-Node-ThunderX2 (2x-tx2) + +{{< figure src="/cdocs/testbed-2n-tx2.svg" >}} + +``` +- SUT [Server-Type-E22]: + - testbedname: testbed211. + - hostname: s27-t211-sut1. + - IPMI IP: 10.30.50.69 + - Host IP: 10.30.51.69 + - portnames: + - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 + - portnames: + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +### 2-Node-Icelake (2n-icx) + +{{< figure src="/cdocs/testbed-2n-icx.svg" >}} + +``` +- SUT [Server-Type-F1]: + - testbedname: testbed212. + - hostname: s71-t212-sut1. + - IPMI IP: 10.30.50.81 + - Host IP: 10.30.51.81 + - portnames: + - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed212. + - hostname: s72-t212-tg1. + - IPMI IP: 10.30.50.82 + - Host IP: 10.30.51.82 + - portnames: + - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed213. + - hostname: s83-t213-sut1. + - IPMI IP: 10.30.50.83 + - Host IP: 10.30.51.83 + - portnames: + - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed213. + - hostname: s84-t213-tg1. + - IPMI IP: 10.30.50.84 + - Host IP: 10.30.51.84 + - portnames: + - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed214. + - hostname: s85-t214-sut1. + - IPMI IP: 10.30.50.85 + - Host IP: 10.30.51.85 + - portnames: + - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed214. + - hostname: s86-t214-tg1. + - IPMI IP: 10.30.50.86 + - Host IP: 10.30.51.86 + - portnames: + - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed215. + - hostname: s87-t215-sut1. + - IPMI IP: 10.30.50.87 + - Host IP: 10.30.51.87 + - portnames: + - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed215. + - hostname: s88-t215-tg1. + - IPMI IP: 10.30.50.88 + - Host IP: 10.30.51.88 + - portnames: + - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +### 3-Node-Rangeley (3n-rng) + +Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. + +``` +- ServerB22 [Server-Type-B5]: + - testbedname: testbed35. + - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). + - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 + - Host IP: 10.30.51.9 + - portnames: + - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- ServerB23 [Server-Type-B5]: + - testbedname: testbed35. + - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 + - Host IP: 10.30.51.10 + - portnames: + - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- ServerB24 [Server-Type-B5]: + - testbedname: testbed35. + - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 + - Host IP: 10.30.51.11 + - portnames: + - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +``` + +### 3-Node-Taishan (3n-tsh) + +{{< figure src="/cdocs/testbed-3n-tsh.svg" >}} + +``` +- SUT [Server-Type-E21]: + - testbedname: testbed33. + - hostname: s17-t33-sut1. + - IPMI IP: 10.30.50.36 + - Host IP: 10.30.51.36 + - portnames: + - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE. + - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. + - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. + - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. +- SUT [Server-Type-E21]: + - testbedname: testbed33. + - hostname: s18-t33-sut2. + - IPMI IP: 10.30.50.37 + - Host IP: 10.30.51.37 + - portnames: + - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE. + - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. + - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. + - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 + - portnames: + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +### 3-Node-Altra (3n-alt) + +{{< figure src="/cdocs/testbed-3n-alt.svg" >}} + +``` +- SUT [Server-Type-E23]: + - testbedname: testbed34. + - hostname: s62-t34-sut1. + - IPMI IP: 10.30.50.72 + - Host IP: 10.30.51.72 + - portnames: + - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. +- SUT [Server-Type-E23]: + - testbedname: testbed34. + - hostname: s63-t34-sut2. + - IPMI IP: 10.30.50.73 + - Host IP: 10.30.51.73 + - portnames: + - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. +- TG [Server-Type-F4]: + - testbedname: testbed34. + - hostname: s64-t34-tg1. + - IPMI IP: 10.30.50.74 + - Host IP: 10.30.51.74 + - portnames: + - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +### 3-Node-Icelake (3n-icx) + +{{< figure src="/cdocs/testbed-3n-icx.svg" >}} + +``` +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s65-t37-sut1. + - IPMI IP: 10.30.50.75 + - Host IP: 10.30.51.75 + - portnames: + - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s66-t37-sut2. + - IPMI IP: 10.30.50.76 + - Host IP: 10.30.51.76 + - portnames: + - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed37. + - hostname: s67-t37-tg1. + - IPMI IP: 10.30.50.77 + - Host IP: 10.30.51.77 + - portnames: + - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s78-t38-sut1. + - IPMI IP: 10.30.50.78 + - Host IP: 10.30.51.78 + - portnames: + - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s79-t38-sut2. + - IPMI IP: 10.30.50.79 + - Host IP: 10.30.51.79 + - portnames: + - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed38. + - hostname: s80-t38-tg1. + - IPMI IP: 10.30.50.80 + - Host IP: 10.30.51.80 + - portnames: + - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +### 3-Node-SnowRidge (3n-snr) + +{{< figure src="/cdocs/testbed-3n-snr.svg" >}} + +``` +- ServerG1 [Server-Type-G1]: + - testbedname: testbed39. + - hostname: s93-t39-sut1. + - IPMI IP: 10.30.50.93 + - Host IP: 10.30.51.93 + - portnames: + - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE. +- ServerG1 [Server-Type-G1]: + - testbedname: testbed39. + - hostname: s94-t39-sut2. + - IPMI IP: 10.30.50.94 + - Host IP: 10.30.51.94 + - portnames: + - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- ServerF4 [Server-Type-F4]: + - testbedname: testbed39. + - hostname: s89-t39t310-tg1. + - IPMI IP: 10.30.50.89 + - Host IP: 10.30.51.89 + - portnames: + - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +``` + +### 2-Node-SapphireRapids (2n-spr) + +{{< figure src="/cdocs/testbed-2n-spr.svg" >}} + +``` +- SUT [Server-Type-H1]: + - testbedname: testbed21. + - hostname: s52-t21-sut1. + - IPMI IP: 10.30.50.52 + - Host IP: 10.30.51.52 + - portnames: + - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE. +- TG [Server-Type-H2]: + - testbedname: testbed21. + - hostname: s53-t21-tg1. + - IPMI IP: 10.30.50.53 + - Host IP: 10.30.51.53 + - portnames: + - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. +- SUT [Server-Type-H3]: + - testbedname: testbed22. + - hostname: s54-t22-sut1. + - IPMI IP: 10.30.50.54 + - Host IP: 10.30.51.54 + - portnames: + - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H4]: + - testbedname: testbed22. + - hostname: s55-t22-tg1. + - IPMI IP: 10.30.50.55 + - Host IP: 10.30.51.55 + - portnames: + - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- SUT [Server-Type-H5]: + - testbedname: testbed23. + - hostname: s56-t23-sut1. + - IPMI IP: 10.30.50.56 + - Host IP: 10.30.51.56 + - portnames: + - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H6]: + - testbedname: testbed23. + - hostname: s57-t23-tg1. + - IPMI IP: 10.30.50.57 + - Host IP: 10.30.51.57 + - portnames: + - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-H5]: + - testbedname: testbed24. + - hostname: s58-t24-sut1. + - IPMI IP: 10.30.50.58 + - Host IP: 10.30.51.58 + - portnames: + - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H6]: + - testbedname: testbed24. + - hostname: s59-t24-tg1. + - IPMI IP: 10.30.50.59 + - Host IP: 10.30.51.59 + - portnames: + - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +## Testbed Wiring + +### 1-Node-Skylake (1n-skx) + +``` +- testbed11: + - ring1 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. +- testbed12: + - ring1 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. +``` + +### 1-Node-ThunderX2 (1n-tx2) + +``` +- testbed13: + - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. + - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. + +- testbed14: + - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. + - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. +``` + +### 2-Node-IxiaPS1L47 (2n-ps1) + +``` +- testbed25: + - link1 10GE-port x710-4p10GE on SUT: + - t25-tg1-p1 to t25-sut1-c2/p1. + - link2 10GE-port x710-4p10GE on SUT: + - t25-tg1-p2 to t25-sut1-c2/p2. + - link3 10GE-port x710-4p10GE on SUT: + - t25-tg1-p3 to t25-sut1-c2/p3. + - link4 10GE-port x710-4p10GE on SUT: + - t25-tg1-p4 to t25-sut1-c2/p4. +``` + +### 2-Node-Cascadelake (2n-clx) + +``` +- testbed27: + - ring1 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. + - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. + - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. + - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. + - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. + - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. + - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. +- testbed28: + - ring1 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. + - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. + - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. + - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. + - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. + - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. + - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. +- testbed29: + - ring1 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. + - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. + - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. + - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. + - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. + - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. +``` + +### 2-Node-Zen2 (2n-zn2) + +``` +- testbed210: + - ring1 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. + - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. + - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. + - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. + - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. +``` + +### 2-Node-ThunderX2 (2n-tx2) + +``` +- testbed211: + - ring1 10GE-ports x520-2p10GE on SUTs: + - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. + - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. +``` + +### 2-Node-Icelake (2n-icx) + +``` +- testbed212: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. + - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. + - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. + - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. + - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. + - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. + - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. +- testbed213: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. + - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. + - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. + - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. + - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. + - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. + - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. +- testbed214: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. + - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. + - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. + - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. + - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. + - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. + - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. +- testbed215: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. + - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. + - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. + - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. + - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. + - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. + - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. +``` + +### 3-Node-Rangeley (3n-rng) + +``` +To be completed. +``` + +### 3-Node-Taishan (3n-tsh) + +``` +- testbed33: + - ring1 10GE-ports x520-2p10GE on SUTs: + - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. + - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. + - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. + - ring2 25GE-ports cx4-2p25GE on SUTs: + - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. + - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. + - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. +``` + +### 3-Node-Altra (3n-alt) + +``` +- testbed34: + - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: + - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. + - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. + - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. +``` + +### 3-Node-Icelake (3n-icx) + +``` +- testbed37: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. + - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. + - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. + - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. + - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. + - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. + - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. + - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. + - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. + - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. +- testbed38: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. + - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. + - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. + - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. + - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. + - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. + - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. + - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. + - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. + - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. +``` + +### 3-Node-SnowRidge (3n-snr) + +``` +- testbed39: + - ring1 25GE-ports e810-XXVDA4-4p25GE: + - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. + - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. + - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. + - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3. + - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4. + - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. +``` + +### 2-Node-SapphireRapids (2n-spr) + +``` +- testbed21: + - ring1 200GE-ports ConnectX7-2p200GE: + - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1 + - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1 + - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2 + - ring2 200GE-ports ConnectX7-2p200GE: + - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2 + - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2 + - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1 + - ring3 200GE-ports ConnectX7-2p200GE: + - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1 + - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1 + - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2 +- testbed22: + - ring1 100GE-ports e810-2CQDA2-2p100GE: + - s55-t22-tg1-c4/p1 to s54-t22-sut1-c9/p2 + - s55-t22-tg1-c4/p2 to s54-t22-sut1-c4/p2 + - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1 + - ring2 25GE-ports e810-XXVDA4-4p25GE: + - s55-t22-tg1-c2/p1 to s54-t22-sut1-c2/p1 + - s55-t22-tg1-c2/p2 to s54-t22-sut1-c7/p1 + - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2 +- testbed23: + - ring1 200GE-ports ConnectX7-2p200GE: + - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1. + - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2. + - ring2 100GE-ports e810-2CQDA2-2p100GE: + - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. + - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. + - ring3 25GE-ports e810-XXVDA4-2p25GE: + - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. + - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. + - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. + - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4. + - ring4 200GE-ports ConnectX7-2p200GE: + - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2. + - ring5 100GE-ports e810-2CQDA2-2p100GE: + - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2. +- testbed24: + - ring1 200GE-ports ConnectX7-2p200GE: + - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1. + - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2. + - ring2 100GE-ports e810-2CQDA2-2p100GE: + - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. + - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. + - ring3 25GE-ports e810-XXVDA4-2p25GE: + - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. + - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. + - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. + - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4. + - ring4 200GE-ports ConnectX7-2p200GE: + - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. + - ring5 100GE-ports e810-2CQDA2-2p100GE: + - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. +``` |