aboutsummaryrefslogtreecommitdiffstats
path: root/docs/content/infrastructure/fdio_dc_testbed_specifications.md
diff options
context:
space:
mode:
authorTibor Frank <tifrank@cisco.com>2023-05-03 13:53:27 +0000
committerTibor Frank <tifrank@cisco.com>2023-05-09 05:56:22 +0000
commit374954b9d648f503f6783325a1266457953a998d (patch)
tree5514dee6af2a2e069189efe39d4e929dd25721f7 /docs/content/infrastructure/fdio_dc_testbed_specifications.md
parent46eac7bb697e8261dba5b439a15f5a6125f31760 (diff)
C-Docs: New structure
Change-Id: I73d107f94b28b138f3350a9e1eedb0555583a9ca Signed-off-by: Tibor Frank <tifrank@cisco.com>
Diffstat (limited to 'docs/content/infrastructure/fdio_dc_testbed_specifications.md')
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md1861
1 files changed, 1861 insertions, 0 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
new file mode 100644
index 0000000000..3daa3824e2
--- /dev/null
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -0,0 +1,1861 @@
+---
+bookToc: true
+title: "FD.io DC Testbed Specifications"
+weight: 2
+---
+
+# FD.io DC Testbed Specifications
+
+## Purpose
+
+This note includes specification of the physical testbed infrastructure
+hosted by LFN FD.io CSIT project.
+
+## Server Management
+
+### Addressing
+
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
+Management port, which are connected to two different VLANs.
+
+#### LOM (IPMI) VLAN
+
+ - Subnet: 10.30.50.0/24
+ - Gateway: 10.30.50.1
+ - Broadcast: 10.30.50.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+
+#### Management VLAN
+ - Subnet: 10.30.51.0/24
+ - Gateway: 10.30.51.1
+ - Broadcast: 10.30.51.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+
+To access these hosts, VPN connection is required.
+
+## Testbeds Overview
+
+### Summary List
+
+```
+ #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
+ 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
+ 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
+ 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
+ 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
+ 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
+ 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
+ 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
+ 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
+10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
+11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
+12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
+13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
+13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
+ Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
+```
+
+### 1-Node-Skylake Xeon Intel (1n-skx)
+
+Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
+
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-Cascadelake Xeon Intel (1n-clx)
+
+Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
+NIC ports connected back-to-back ([Server Types](#server-types)).
+
+Used for FD.io VPP_Device functional driver tests.
+
+### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
+
+Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
+TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
+circular topology ([Server Types](#server-types)).
+Used for FD.io TCP/IP and HTTP performance tests.
+
+### 2-Node-Cascadelake Xeon Intel (2n-clx)
+
+Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
+one TG (Server-Type-C3) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Zen2 EPYC AMD (2n-zn2)
+
+Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
+one TG (Server-Type-D2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
+
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
+one TG (Server-Type-E31) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Icelake Xeon Intel (2n-icx)
+
+Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
+one TG (Server-Type-F2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Rangeley Atom Testbeds
+
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-TaiShan Arm Huawei (3n-tsh)
+
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
+TG (Server-Type-E31) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Altra Arm Ampere (3n-alt)
+
+Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Icelake Xeon Intel (3n-icx)
+
+Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
+TG (Server-Type-F3) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-SnowRidge Atom Intel (3n-snr)
+
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
+
+One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
+one TG (Server-Type-H2) connected in a 2-node physical topology
+with NUMA (socket) daisy chaining. For more detail see
+[Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests in a full system SUT setup with all PCIe
+Gen5 x16 lane slots populated with 2p200GbE NICs.
+
+### 2-Node-SapphireRapids Xeon Intel (2n-spr)
+
+Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
+one TG (Server-Type-H6) connected in a 2-node circular topology. For more
+detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests.
+
+
+## Tesdtbed Naming Convention
+
+Following naming convention is used within this page to specify physical
+connectivity and wiring across defined CSIT testbeds:
+
+- **testbedname**: testbedN.
+- **hostname**:
+ - traffic-generator: tN-tgW.
+ - system-under-testX: tN-sutX.
+- **portnames**:
+ - tN-tgW-cY/pZ.
+ - tN-sutX-cY/pZ.
+- **where**:
+ - N - testbed number.
+ - tgW - server acts as traffic-generator with W index.
+ - sutX - server acts as system-under-test with X index.
+ - Y - PCIe slot number denoting a NIC card number within the host.
+ - Z - port number on the NIC card.
+
+## Server Types
+
+FD.io CSIT lab contains following server types:
+
+1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: empty.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - Host management interface: 10/100/1000-BaseT.
+ - 8-port 10GE SFP+ integrated NIC.
+ - Main HW configuration:
+ - Chassis: PS10GE4NG.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: Quad-Core, Intel Processor.
+ - HW accelerators: FPGA offload.
+ - RAM Memory: 64GB.
+ - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
+ - Physical Interfaces: 4 * 10GE SFP+.
+ - Operating System: Native IxOS.
+ - Interface configuration:
+ - Port-1: 10GE SFP+.
+ - Port-2: 10GE SFP+.
+ - Port-3: 10GE SFP+.
+ - Port-4: 10GE SFP+.
+
+4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+ - Quantity: 3
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Gold 6252N 2.3 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+ - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
+ - PCIe Slot10 d8:00.xx: empty.
+
+8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - no NIC ports, standalone setup.
+ - Main HW configuration:
+ - Chassis: SuperMicro 1029P-WTRT.
+ - Motherboard: SuperMicro X11DDW-NT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 4* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0:
+ - no cards.
+ - Numa1:
+ - no cards.
+
+9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro AS-1114S-WTRT
+ - Processors: 1* AMD EPYC 7532 2.4 GHz.
+ - RAM Memory: 8* 32GB DDR4-2933.
+ - Disks: 1* 1TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
+ - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+
+10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro AS-1114S-WTRT
+ - Processors: 1* AMD EPYC 7532 2.4 GHz.
+ - RAM Memory: 8* 32GB DDR4-2933.
+ - Disks: 1* 1TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+ - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
+ - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+
+11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: GIGABYTE Rack Mount
+ - Motherboard: MT91-FS4-00
+ - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
+ - RAM Memory: 16 * 16GB DIMM
+ - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
+ - Numa1:
+ - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+
+12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI(?) and host management ports.
+ - NIC ports connected into 3-node topology.
+ - Main HW configuration:
+ - Chassis: Huawei TaiShan 2280.
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
+ - RAM Memory: 8* 16GB DDR4-2400MT/s
+ - Disks: 1* 4TB SATA HDD
+ - NICs configuration:
+ - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+ - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+
+13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node topologies.
+ - Main HW configuration:
+ - Chassis: Gigabyte R181-T90 1U
+ - Motherboard: MT91-FS1
+ - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - RAM Memory: 4* 32GB RDIMM
+ - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+ - NICs configuration:
+ - Numa0:
+ - no cards
+ - Numa1:
+ - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
+
+14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node topologies.
+ - Main HW configuration:
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Motherboard: Mt.Jade Motherboard
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+ - Numa1:
+ - no cards.
+15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - Main HW configuration:
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+
+16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+
+17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
+ - Quantity: 8.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and/or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 d8:00.xx: empty.
+
+21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topology.
+ - Main HW configuration:
+ - Chassis: Intel JACOBSVILLE SDP.
+ - Motherboard: Intel JACOBSVILLE E63448-400.
+ - Processors: 1* Intel Atom P5362B 2.2 GHz.
+ - RAM Memory: 2* 16GB DDR4-2933.
+ - Disks: ?* ? SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, PCIe3.0 lane)
+ - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
+
+22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+
+23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot11 d8:00.xx: empty.
+
+24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot11 d8:00.xx: empty.
+
+25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+
+26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+
+27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot11 d8:00.xx: empty.
+
+## Testbeds Configuration
+
+### 1-Node-Skylake (1n-skx)
+
+```
+- SUT [Server-Type-B6]:
+ - testbedname: testbed11.
+ - hostname: s1-t11-sut1.
+ - IPMI IP: 10.30.50.47
+ - Host IP: 10.30.51.50
+ - portnames:
+ - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+- SUT [Server-Type-B6]:
+ - testbedname: testbed12.
+ - hostname: s2-t12-sut1.
+ - IPMI IP: 10.30.50.48
+ - Host IP: 10.30.51.51
+ - portnames:
+ - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+```
+
+### 1-Node-ThunderX2 (1n-tx2)
+
+```
+- SUT [Server-Type-E11]:
+ - testbedname: testbed13
+ - hostname: s55-t13-sut1
+ - IPMI IP: 10.30.50.70
+ - Host IP: 10.30.51.70
+ - portnames:
+ - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+- SUT [Server-Type-E11]:
+ - testbedname: testbed14
+ - hostname: s56-t14-sut1
+ - IPMI IP: 10.30.50.71
+ - Host IP: 10.30.51.71
+ - portnames:
+ - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+```
+
+### 1-Node-Cascadelake (1n-clx)
+
+```
+- SUT [Server-Type-C1]:
+ - testbedname: testbed11.
+ - hostname: s32-t14-sut1.
+ - IPMI IP: 10.30.55.17
+ - Host IP: 10.32.8.17
+ - portnames:
+ - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+```
+
+### 2-Node-IxiaPS1L47 (2n-ps1)
+
+```
+- SUT [Server-Type-B8]:
+ - testbedname: testbed25.
+ - hostname: s25-t25-sut1.
+ - IPMI IP: 10.30.50.58
+ - Host IP: 10.30.51.61
+ - portnames:
+ - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+- TG [Server-Type-B7]:
+ - testbedname: testbed25.
+ - hostname: s26-t25-tg1.
+ - IPMI IP: 10.30.50.59
+ - Host IP: 10.30.51.62
+ - portnames:
+ - s26-t25-tg1-p1 - 10GE-port1.
+ - s26-t25-tg1-p2 - 10GE-port2.
+ - s26-t25-tg1-p3 - 10GE-port3.
+ - s26-t25-tg1-p4 - 10GE-port4.
+```
+
+### 2-Node-Cascadelake (2n-clx)
+
+{{< figure src="/cdocs/testbed-2n-clx.svg" >}}
+
+```
+- SUT [Server-Type-C2]:
+ - testbedname: testbed27.
+ - hostname: s33-t27-sut1.
+ - IPMI IP: 10.30.55.18
+ - Host IP: 10.32.8.18
+ - portnames:
+ - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed27.
+ - hostname: s34-t27-tg1.
+ - IPMI IP: 10.30.55.19
+ - Host IP: 10.32.8.19
+ - portnames:
+ - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+ - testbedname: testbed28.
+ - hostname: s35-t28-sut1.
+ - IPMI IP: 10.30.55.20
+ - Host IP: 10.32.8.20
+ - portnames:
+ - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed28.
+ - hostname: s36-t28-tg1.
+ - IPMI IP: 10.30.55.21
+ - Host IP: 10.32.8.21
+ - portnames:
+ - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+ - testbedname: testbed29.
+ - hostname: s37-t29-sut1.
+ - IPMI IP: 10.30.55.22
+ - Host IP: 10.32.8.22
+ - portnames:
+ - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed29.
+ - hostname: s38-t29-tg1.
+ - IPMI IP: 10.30.55.23
+ - Host IP: 10.32.8.23
+ - portnames:
+ - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+```
+
+### 2-Node-Zen2 (2n-zn2)
+
+{{< figure src="/cdocs/testbed-2n-zn2.svg" >}}
+
+```
+- SUT [Server-Type-D1]:
+ - testbedname: testbed210.
+ - hostname: s60-t210-sut1.
+ - IPMI IP: 10.30.55.24
+ - Host IP: 10.32.8.24
+ - portnames:
+ - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
+ - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
+ - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
+ - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
+ - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-D2]:
+ - testbedname: testbed210.
+ - hostname: s61-t210-tg1.
+ - IPMI IP: 10.30.55.25
+ - Host IP: 10.32.8.25
+ - portnames:
+ - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+```
+
+### 2-Node-ThunderX2 (2x-tx2)
+
+{{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
+
+```
+- SUT [Server-Type-E22]:
+ - testbedname: testbed211.
+ - hostname: s27-t211-sut1.
+ - IPMI IP: 10.30.50.69
+ - Host IP: 10.30.51.69
+ - portnames:
+ - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
+ - portnames:
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+### 2-Node-Icelake (2n-icx)
+
+{{< figure src="/cdocs/testbed-2n-icx.svg" >}}
+
+```
+- SUT [Server-Type-F1]:
+ - testbedname: testbed212.
+ - hostname: s71-t212-sut1.
+ - IPMI IP: 10.30.50.81
+ - Host IP: 10.30.51.81
+ - portnames:
+ - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed212.
+ - hostname: s72-t212-tg1.
+ - IPMI IP: 10.30.50.82
+ - Host IP: 10.30.51.82
+ - portnames:
+ - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed213.
+ - hostname: s83-t213-sut1.
+ - IPMI IP: 10.30.50.83
+ - Host IP: 10.30.51.83
+ - portnames:
+ - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed213.
+ - hostname: s84-t213-tg1.
+ - IPMI IP: 10.30.50.84
+ - Host IP: 10.30.51.84
+ - portnames:
+ - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed214.
+ - hostname: s85-t214-sut1.
+ - IPMI IP: 10.30.50.85
+ - Host IP: 10.30.51.85
+ - portnames:
+ - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed214.
+ - hostname: s86-t214-tg1.
+ - IPMI IP: 10.30.50.86
+ - Host IP: 10.30.51.86
+ - portnames:
+ - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed215.
+ - hostname: s87-t215-sut1.
+ - IPMI IP: 10.30.50.87
+ - Host IP: 10.30.51.87
+ - portnames:
+ - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed215.
+ - hostname: s88-t215-tg1.
+ - IPMI IP: 10.30.50.88
+ - Host IP: 10.30.51.88
+ - portnames:
+ - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+### 3-Node-Rangeley (3n-rng)
+
+Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
+
+```
+- ServerB22 [Server-Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
+ - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
+ - Host IP: 10.30.51.9
+ - portnames:
+ - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+- ServerB23 [Server-Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
+ - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
+ - Host IP: 10.30.51.10
+ - portnames:
+ - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+- ServerB24 [Server-Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
+ - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
+ - Host IP: 10.30.51.11
+ - portnames:
+ - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+```
+
+### 3-Node-Taishan (3n-tsh)
+
+{{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
+
+```
+- SUT [Server-Type-E21]:
+ - testbedname: testbed33.
+ - hostname: s17-t33-sut1.
+ - IPMI IP: 10.30.50.36
+ - Host IP: 10.30.51.36
+ - portnames:
+ - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
+ - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
+ - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
+ - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
+- SUT [Server-Type-E21]:
+ - testbedname: testbed33.
+ - hostname: s18-t33-sut2.
+ - IPMI IP: 10.30.50.37
+ - Host IP: 10.30.51.37
+ - portnames:
+ - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
+ - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
+ - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
+ - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
+ - portnames:
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+### 3-Node-Altra (3n-alt)
+
+{{< figure src="/cdocs/testbed-3n-alt.svg" >}}
+
+```
+- SUT [Server-Type-E23]:
+ - testbedname: testbed34.
+ - hostname: s62-t34-sut1.
+ - IPMI IP: 10.30.50.72
+ - Host IP: 10.30.51.72
+ - portnames:
+ - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- SUT [Server-Type-E23]:
+ - testbedname: testbed34.
+ - hostname: s63-t34-sut2.
+ - IPMI IP: 10.30.50.73
+ - Host IP: 10.30.51.73
+ - portnames:
+ - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- TG [Server-Type-F4]:
+ - testbedname: testbed34.
+ - hostname: s64-t34-tg1.
+ - IPMI IP: 10.30.50.74
+ - Host IP: 10.30.51.74
+ - portnames:
+ - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+### 3-Node-Icelake (3n-icx)
+
+{{< figure src="/cdocs/testbed-3n-icx.svg" >}}
+
+```
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s65-t37-sut1.
+ - IPMI IP: 10.30.50.75
+ - Host IP: 10.30.51.75
+ - portnames:
+ - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s66-t37-sut2.
+ - IPMI IP: 10.30.50.76
+ - Host IP: 10.30.51.76
+ - portnames:
+ - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed37.
+ - hostname: s67-t37-tg1.
+ - IPMI IP: 10.30.50.77
+ - Host IP: 10.30.51.77
+ - portnames:
+ - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s78-t38-sut1.
+ - IPMI IP: 10.30.50.78
+ - Host IP: 10.30.51.78
+ - portnames:
+ - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s79-t38-sut2.
+ - IPMI IP: 10.30.50.79
+ - Host IP: 10.30.51.79
+ - portnames:
+ - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed38.
+ - hostname: s80-t38-tg1.
+ - IPMI IP: 10.30.50.80
+ - Host IP: 10.30.51.80
+ - portnames:
+ - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+### 3-Node-SnowRidge (3n-snr)
+
+{{< figure src="/cdocs/testbed-3n-snr.svg" >}}
+
+```
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s93-t39-sut1.
+ - IPMI IP: 10.30.50.93
+ - Host IP: 10.30.51.93
+ - portnames:
+ - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s94-t39-sut2.
+ - IPMI IP: 10.30.50.94
+ - Host IP: 10.30.51.94
+ - portnames:
+ - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+ - testbedname: testbed39.
+ - hostname: s89-t39t310-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+```
+
+### 2-Node-SapphireRapids (2n-spr)
+
+{{< figure src="/cdocs/testbed-2n-spr.svg" >}}
+
+```
+- SUT [Server-Type-H1]:
+ - testbedname: testbed21.
+ - hostname: s52-t21-sut1.
+ - IPMI IP: 10.30.50.52
+ - Host IP: 10.30.51.52
+ - portnames:
+ - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
+- TG [Server-Type-H2]:
+ - testbedname: testbed21.
+ - hostname: s53-t21-tg1.
+ - IPMI IP: 10.30.50.53
+ - Host IP: 10.30.51.53
+ - portnames:
+ - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+- SUT [Server-Type-H3]:
+ - testbedname: testbed22.
+ - hostname: s54-t22-sut1.
+ - IPMI IP: 10.30.50.54
+ - Host IP: 10.30.51.54
+ - portnames:
+ - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H4]:
+ - testbedname: testbed22.
+ - hostname: s55-t22-tg1.
+ - IPMI IP: 10.30.50.55
+ - Host IP: 10.30.51.55
+ - portnames:
+ - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- SUT [Server-Type-H5]:
+ - testbedname: testbed23.
+ - hostname: s56-t23-sut1.
+ - IPMI IP: 10.30.50.56
+ - Host IP: 10.30.51.56
+ - portnames:
+ - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H6]:
+ - testbedname: testbed23.
+ - hostname: s57-t23-tg1.
+ - IPMI IP: 10.30.50.57
+ - Host IP: 10.30.51.57
+ - portnames:
+ - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-H5]:
+ - testbedname: testbed24.
+ - hostname: s58-t24-sut1.
+ - IPMI IP: 10.30.50.58
+ - Host IP: 10.30.51.58
+ - portnames:
+ - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H6]:
+ - testbedname: testbed24.
+ - hostname: s59-t24-tg1.
+ - IPMI IP: 10.30.50.59
+ - Host IP: 10.30.51.59
+ - portnames:
+ - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+## Testbed Wiring
+
+### 1-Node-Skylake (1n-skx)
+
+```
+- testbed11:
+ - ring1 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
+ - ring2 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+ - ring4 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
+ - ring5 100GE-ports e810-2p100GE:
+ - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
+ - ring6 100GE-ports e810-2p100GE:
+ - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
+- testbed12:
+ - ring1 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
+ - ring2 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+ - ring4 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
+ - ring5 100GE-ports e810-2p100GE:
+ - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
+ - ring6 100GE-ports e810-2p100GE:
+ - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
+```
+
+### 1-Node-ThunderX2 (1n-tx2)
+
+```
+- testbed13:
+ - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
+ - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
+ - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
+ - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
+
+- testbed14:
+ - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
+ - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
+ - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
+ - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
+```
+
+### 2-Node-IxiaPS1L47 (2n-ps1)
+
+```
+- testbed25:
+ - link1 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p1 to t25-sut1-c2/p1.
+ - link2 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p2 to t25-sut1-c2/p2.
+ - link3 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p3 to t25-sut1-c2/p3.
+ - link4 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p4 to t25-sut1-c2/p4.
+```
+
+### 2-Node-Cascadelake (2n-clx)
+
+```
+- testbed27:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
+ - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
+ - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
+ - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
+ - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
+ - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+ - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
+- testbed28:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
+ - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
+ - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
+ - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
+ - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
+ - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+ - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
+- testbed29:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
+ - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
+ - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
+ - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
+ - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
+ - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
+```
+
+### 2-Node-Zen2 (2n-zn2)
+
+```
+- testbed210:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
+ - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
+ - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
+ - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
+ - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
+```
+
+### 2-Node-ThunderX2 (2n-tx2)
+
+```
+- testbed211:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
+ - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
+ - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
+```
+
+### 2-Node-Icelake (2n-icx)
+
+```
+- testbed212:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
+ - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
+ - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
+ - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
+ - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
+ - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
+ - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
+- testbed213:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+ - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+ - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+ - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+ - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+ - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+ - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
+- testbed214:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+ - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+ - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+ - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+ - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+ - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+ - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
+- testbed215:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+ - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+ - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+ - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+ - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+ - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+ - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
+```
+
+### 3-Node-Rangeley (3n-rng)
+
+```
+To be completed.
+```
+
+### 3-Node-Taishan (3n-tsh)
+
+```
+- testbed33:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
+ - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
+ - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
+ - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
+ - ring2 25GE-ports cx4-2p25GE on SUTs:
+ - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
+ - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
+ - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
+```
+
+### 3-Node-Altra (3n-alt)
+
+```
+- testbed34:
+ - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
+ - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+ - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+ - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
+```
+
+### 3-Node-Icelake (3n-icx)
+
+```
+- testbed37:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
+ - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
+ - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
+ - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
+ - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
+ - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
+ - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
+ - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
+ - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
+ - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
+- testbed38:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+ - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+ - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+ - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+ - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+ - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+ - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+ - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+ - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+ - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+### 3-Node-SnowRidge (3n-snr)
+
+```
+- testbed39:
+ - ring1 25GE-ports e810-XXVDA4-4p25GE:
+ - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+ - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+ - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+ - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+ - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+ - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
+```
+
+### 2-Node-SapphireRapids (2n-spr)
+
+```
+- testbed21:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
+ - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
+ - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
+ - ring2 200GE-ports ConnectX7-2p200GE:
+ - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
+ - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
+ - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
+ - ring3 200GE-ports ConnectX7-2p200GE:
+ - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
+ - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
+ - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
+- testbed22:
+ - ring1 100GE-ports e810-2CQDA2-2p100GE:
+ - s55-t22-tg1-c4/p1 to s54-t22-sut1-c9/p2
+ - s55-t22-tg1-c4/p2 to s54-t22-sut1-c4/p2
+ - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
+ - ring2 25GE-ports e810-XXVDA4-4p25GE:
+ - s55-t22-tg1-c2/p1 to s54-t22-sut1-c2/p1
+ - s55-t22-tg1-c2/p2 to s54-t22-sut1-c7/p1
+ - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
+- testbed23:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
+ - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
+ - ring2 100GE-ports e810-2CQDA2-2p100GE:
+ - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
+ - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
+ - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
+ - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
+ - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
+ - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
+ - ring4 200GE-ports ConnectX7-2p200GE:
+ - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
+ - ring5 100GE-ports e810-2CQDA2-2p100GE:
+ - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
+- testbed24:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
+ - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
+ - ring2 100GE-ports e810-2CQDA2-2p100GE:
+ - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
+ - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
+ - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
+ - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
+ - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
+ - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
+ - ring4 200GE-ports ConnectX7-2p200GE:
+ - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
+ - ring5 100GE-ports e810-2CQDA2-2p100GE:
+ - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
+```