diff options
author | Peter Mikus <peter.mikus@protonmail.ch> | 2024-09-16 12:22:45 +0200 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2024-09-16 12:22:45 +0200 |
commit | 4f727ccb9c432dc54d1e76785ba7f29e65030fa6 (patch) | |
tree | e2ecbaff56858fa3d11a437f4488828898d85895 /docs/content/infrastructure/fdio_dc_testbed_specifications.md | |
parent | adbdd8ea63631683a2aa707ac294f21cf9f14714 (diff) |
feat(infra): Movements part 3
Signed-off-by: Peter Mikus <peter.mikus@protonmail.ch>
Change-Id: Ifcd47fd5ffaaf974b4e7d0c8dce391a21842b45a
Diffstat (limited to 'docs/content/infrastructure/fdio_dc_testbed_specifications.md')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 20 |
1 files changed, 10 insertions, 10 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 831cee47e4..cda2ff1624 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -49,7 +49,7 @@ To access these hosts, VPN connection is required. 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 0 9. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 0 10. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 0 -11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0 0 +11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 .5 0 0 2 0 0 0 12. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 0 13. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4 0 14. 2-Node-Grace perf grc icx 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1 @@ -194,7 +194,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. **Server-Type-C2**: Purpose - Cascadelake Xeon TG for FD.io performance testing. +2. **Server-Type-C2**: Purpose - Cascadelake Xeon Shared TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -206,13 +206,13 @@ FD.io CSIT lab contains following server types: - RAM Memory: 12* 16GB DDR4-2933. - Disks: 2* 1.92TB SATA SSD. - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 31:00.xx: empty. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 3. **Server-Type-C3**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. @@ -1141,7 +1141,7 @@ FD.io CSIT lab contains following server types: - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerF4 [Server-Type-F5]: +- ServerC2 [Server-Type-C2]: - testbedname: testbed39. - hostname: s89-t39t310-tg1. - IPMI IP: 10.30.50.89 |