aboutsummaryrefslogtreecommitdiffstats
path: root/docs/content/infrastructure
diff options
context:
space:
mode:
authorPeter Mikus <peter.mikus@protonmail.ch>2024-09-05 14:35:22 +0200
committerPeter Mikus <peter.mikus@protonmail.ch>2024-09-06 12:48:37 +0000
commit0b12a2c549a0fc0af89a6914549fe3761d64bc1f (patch)
tree736eb001f8cf25243cb326427a663129a7cfc8e7 /docs/content/infrastructure
parentfb49b8d2560cdbc54a275676bfd07736e5fefa85 (diff)
fix(docs): Infra updates
Signed-off-by: Peter Mikus <peter.mikus@protonmail.ch> Change-Id: I79cc085adfdeed9b99886c4ec6aa00fa95173507
Diffstat (limited to 'docs/content/infrastructure')
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md621
1 files changed, 88 insertions, 533 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index da71124078..8a1c13e8ca 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -40,31 +40,21 @@ To access these hosts, VPN connection is required.
```
#. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd
- 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 0
+ 1. 1-Node-Skylake nomad skx na 2 2 0 2 0 0 0 0 0 0 0 0 0 0 0
2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0
3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0
- 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
- 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 0
- 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 0
- 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0
- 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0
- 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 0
-10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0
-11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0
-12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0
-13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0
-14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
-15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0
-16. 3-Node-IcelakeD perf icxd icx 4 6 1 0 0 0 0 0 0 0 0 1 0 0 4
- Totals: 39 48 19.5 7 1 2 1 2 6 10 2 16.5 2 12 4
+ 4. 2-Node-Cascadelake perf clx clx 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0
+ 5. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0
+ 6. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0
+ 7. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0
+ 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0
+ 9. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0
+10. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0
+11. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
+12. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0
+13. 3-Node-IcelakeD perf icxd icx 4 6 1 0 0 0 0 0 0 0 0 1 0 0 4
```
-### 1-Node-Skylake Xeon Intel (1n-skx)
-
-Each 1-Node-Skylake testbed includes one SUT (Server-Type-B2) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
### 1-Node-Altra Arm Ampere (1n-alt)
Each 1-Node-Altra testbed includes one SUT (Server-Type-E25) with NIC
@@ -77,20 +67,6 @@ Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
-### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
-
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
-circular topology ([Server Types](#server-types)).
-Used for FD.io TCP/IP and HTTP performance tests.
-
-### 2-Node-Cascadelake Xeon Intel (2n-clx)
-
-Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
-one TG (Server-Type-C3) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-Zen2 EPYC AMD (2n-zn2)
Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
@@ -98,13 +74,6 @@ one TG (Server-Type-D2) connected in a 2-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
-
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
-one TG (Server-Type-E31) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-Icelake Xeon Intel (2n-icx)
Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
@@ -112,20 +81,6 @@ one TG (Server-Type-F2) connected in a 2-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Rangeley Atom Testbeds
-
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-TaiShan Arm Huawei (3n-tsh)
-
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
-TG (Server-Type-E31) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 3-Node-Altra Arm Ampere (3n-alt)
Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
@@ -185,7 +140,7 @@ connectivity and wiring across defined CSIT testbeds:
FD.io CSIT lab contains following server types:
-1. **Server-Type-B1**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
+1. **Server-Type-B1**: Purpose - Skylake Xeon hosts for FD.io builds and data processing (BUILDER).
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -205,52 +160,10 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. **Server-Type-B2**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot10 d8:00.xx: empty.
-
-3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- - Quantity: 1.
- - Physical connectivity:
- - Host management interface: 10/100/1000-BaseT.
- - 8-port 10GE SFP+ integrated NIC.
- - Main HW configuration:
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
- - Interface configuration:
- - Port-1: 10GE SFP+.
- - Port-2: 10GE SFP+.
- - Port-3: 10GE SFP+.
- - Port-4: 10GE SFP+.
-
-4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- - Quantity: 1.
+1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing (HST).
+ - Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- - NIC ports.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
@@ -259,40 +172,19 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot2 18:00.xx: e810-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-2p100GE Intel.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-5. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- - Quantity: 3
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Gold 6252N 2.3 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-
-6. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- - Quantity: 3.
+2. **Server-Type-C2**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+ - Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
+ - NIC ports connected into 3-node testbed topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
@@ -309,7 +201,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-7. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+3. **Server-Type-C3**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
@@ -330,7 +222,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-8. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+4. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -346,7 +238,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-9. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
+5. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -362,38 +254,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel.
-10. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-
-11. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motherboard: MT91-FS1
- - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - no cards
- - Numa1:
- - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-
-12. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+6. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -412,7 +273,7 @@ FD.io CSIT lab contains following server types:
- Numa1:
- no cards.
-13. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
+7. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -424,7 +285,7 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 12* 16GB DDR4-3200MT/s
- Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-14. **Server-Type-E25**: Purpose - Altra Arm Ampere SUT for FD.io VPP_Device functional tests.
+8. **Server-Type-E25**: Purpose - Altra Arm Ampere SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -445,28 +306,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot3 0003:02:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot5 0005:02:00.xx: ConnectX5-2p10/25GE Mellanox.
-15. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: xl710-QDA2-2p40GE Intel.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-
-16. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+9. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -487,7 +327,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
-17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
+10. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
@@ -508,7 +348,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
+11. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 4.
- Physical connectivity:
- IPMI and host management ports.
@@ -529,7 +369,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-19. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
+12. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
- Quantity: 6.
- Physical connectivity:
- IPMI and host management ports.
@@ -550,7 +390,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-20. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
+13. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -571,7 +411,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-21. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+14. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -592,7 +432,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 ff:00.xx: empty.
-22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+15. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -607,7 +447,7 @@ FD.io CSIT lab contains following server types:
- Numa0: (x16, PCIe3.0 lane)
- PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+16. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -628,7 +468,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia.
-24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+17. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -649,7 +489,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: empty.
-25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+18. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -670,7 +510,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+19. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -691,7 +531,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+20. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -712,7 +552,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+21. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -733,7 +573,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-29. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
+22. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -754,7 +594,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-30. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing.
+23. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
- IPMI and host management ports.
@@ -776,36 +616,20 @@ FD.io CSIT lab contains following server types:
```
- SUT [Server-Type-B2]:
- testbedname: testbed11.
- - hostname: s1-t11-sut1.
+ - hostname: s50-nomad.
- IPMI IP: 10.30.50.47
- Host IP: 10.30.51.50
- portnames:
- - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
- s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
- SUT [Server-Type-B2]:
- testbedname: testbed12.
- - hostname: s2-t12-sut1.
+ - hostname: s51-nomad.
- IPMI IP: 10.30.50.48
- Host IP: 10.30.51.51
- portnames:
- - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
- s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
@@ -856,12 +680,20 @@ FD.io CSIT lab contains following server types:
- testbedname: testbed15.
- hostname: s30-t15-sut1.
- IPMI IP: 10.30.50.30
- - Host IP: 10.30.51.31
+ - Host IP: 10.30.51.30
- portnames:
- s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s30-t15-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
+ - s30-t15-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
+ - s30-t15-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
+ - s30-t15-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
+ - s30-t15-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
+ - s30-t15-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
+ - s30-t15-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
+ - s30-t15-sut1-c9/p4 - 10GE-port4 x710-4p10GE.
- SUT [Server-Type-H7]:
- testbedname: testbed16.
- hostname: s31-t16-sut1.
@@ -872,31 +704,14 @@ FD.io CSIT lab contains following server types:
- s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
-```
-
-### 2-Node-IxiaPS1L47 (2n-ps1)
-
-```
-- SUT [Server-Type-B8]:
- - testbedname: testbed25.
- - hostname: s25-t25-sut1.
- - IPMI IP: 10.30.50.58
- - Host IP: 10.30.51.61
- - portnames:
- - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- TG [Server-Type-B7]:
- - testbedname: testbed25.
- - hostname: s26-t25-tg1.
- - IPMI IP: 10.30.50.59
- - Host IP: 10.30.51.62
- - portnames:
- - s26-t25-tg1-p1 - 10GE-port1.
- - s26-t25-tg1-p2 - 10GE-port2.
- - s26-t25-tg1-p3 - 10GE-port3.
- - s26-t25-tg1-p4 - 10GE-port4.
+ - s31-t16-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
+ - s31-t16-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
+ - s31-t16-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
+ - s31-t16-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
+ - s31-t16-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
+ - s31-t16-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
+ - s31-t16-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
+ - s31-t16-sut1-c9/p4 - 10GE-port4 x710-4p10GE.
```
### 2-Node-Cascadelake (2n-clx)
@@ -904,91 +719,7 @@ FD.io CSIT lab contains following server types:
{{< figure src="/cdocs/testbed-2n-clx.svg" >}}
```
-- SUT [Server-Type-C2]:
- - testbedname: testbed27.
- - hostname: s33-t27-sut1.
- - IPMI IP: 10.30.55.18
- - Host IP: 10.32.8.18
- - portnames:
- - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed27.
- - hostname: s34-t27-tg1.
- - IPMI IP: 10.30.55.19
- - Host IP: 10.32.8.19
- - portnames:
- - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed28.
- - hostname: s35-t28-sut1.
- - IPMI IP: 10.30.55.20
- - Host IP: 10.32.8.20
- - portnames:
- - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed28.
- - hostname: s36-t28-tg1.
- - IPMI IP: 10.30.55.21
- - Host IP: 10.32.8.21
- - portnames:
- - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed29.
- - hostname: s37-t29-sut1.
- - IPMI IP: 10.30.55.22
- - Host IP: 10.32.8.22
- - portnames:
- - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
+- TG [Server-Type-C2]:
- testbedname: testbed29.
- hostname: s38-t29-tg1.
- IPMI IP: 10.30.55.23
@@ -1041,39 +772,6 @@ FD.io CSIT lab contains following server types:
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-### 2-Node-ThunderX2 (2x-tx2)
-
-{{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
-
-```
-- SUT [Server-Type-E22]:
- - testbedname: testbed211.
- - hostname: s27-t211-sut1.
- - IPMI IP: 10.30.50.69
- - Host IP: 10.30.51.69
- - portnames:
- - s27-t211-sut1-c18/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s27-t211-sut1-c18/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- TG [Server-Type-E31]:
- - testbedname: testbed33 and testbed211.
- - hostname: s19-t33t211-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
### 2-Node-Icelake (2n-icx)
{{< figure src="/cdocs/testbed-2n-icx.svg" >}}
@@ -1181,6 +879,13 @@ FD.io CSIT lab contains following server types:
- s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
- s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
+```
+
+### 2-Node-Icelake (2n-oct)
+
+{{< figure src="/cdocs/testbed-2n-oct.svg" >}}
+
+```
- SUT [Server-Type-F1]:
- testbedname: testbed215.
- hostname: s87-t215-sut1.
@@ -1217,51 +922,6 @@ FD.io CSIT lab contains following server types:
- s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
```
-### 3-Node-Taishan (3n-tsh)
-
-{{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
-
-```
-- SUT [Server-Type-E21]:
- - testbedname: testbed33.
- - hostname: s17-t33-sut1.
- - IPMI IP: 10.30.50.36
- - Host IP: 10.30.51.36
- - portnames:
- - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
- - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-E21]:
- - testbedname: testbed33.
- - hostname: s18-t33-sut2.
- - IPMI IP: 10.30.50.37
- - Host IP: 10.30.51.37
- - portnames:
- - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
- - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-E31]:
- - testbedname: testbed33 and testbed211.
- - hostname: s19-t33t211-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
### 3-Node-Altra (3n-alt)
{{< figure src="/cdocs/testbed-3n-alt.svg" >}}
@@ -1635,37 +1295,6 @@ FD.io CSIT lab contains following server types:
## Testbed Wiring
-### 1-Node-Skylake (1n-skx)
-
-```
-- testbed11:
- - ring1 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
- - ring5 100GE-ports e810-2p100GE:
- - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
- - ring6 100GE-ports e810-2p100GE:
- - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
-- testbed12:
- - ring1 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
- - ring5 100GE-ports e810-2p100GE:
- - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
- - ring6 100GE-ports e810-2p100GE:
- - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
-```
-
### 1-Node-Altra (1n-alt)
```
@@ -1702,84 +1331,27 @@ FD.io CSIT lab contains following server types:
- s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
- ring2 100GE-ports e810-2p100GE:
- s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s30-t15-sut1-c7/p1 to s30-t15-sut1-c9/p1.
+ - ring4 10GE-ports x710-4p10GE:
+ - s30-t15-sut1-c7/p2 to s30-t15-sut1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE:
+ - s30-t15-sut1-c7/p3 to s30-t15-sut1-c9/p3.
+ - ring6 10GE-ports x710-4p10GE:
+ - s30-t15-sut1-c7/p4 to s30-t15-sut1-c9/p4.
- testbed16:
- ring1 100GE-ports e810-2p100GE:
- s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
- ring2 100GE-ports e810-2p100GE:
- s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
-```
-
-### 2-Node-IxiaPS1L47 (2n-ps1)
-
-```
-- testbed25:
- - link1 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p1 to t25-sut1-c2/p1.
- - link2 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p2 to t25-sut1-c2/p2.
- - link3 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p3 to t25-sut1-c2/p3.
- - link4 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-### 2-Node-Cascadelake (2n-clx)
-
-```
-- testbed27:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
- - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
- - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
- - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
- - ring6 100GE-ports e810-2p100GE on TG:
- - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
- - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
-- testbed28:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
- - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
- - ring6 100GE-ports e810-2p100GE on TG:
- - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
- - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
-- testbed29:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
- - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s31-t16-sut1-c9/p1 to s31-t16-sut1-c9/p1.
+ - ring4 10GE-ports x710-4p10GE:
+ - s31-t16-sut1-c9/p2 to s31-t16-sut1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE:
+ - s31-t16-sut1-c9/p3 to s31-t16-sut1-c9/p3.
+ - ring6 10GE-ports x710-4p10GE:
+ - s31-t16-sut1-c9/p4 to s31-t16-sut1-c9/p4.
```
### 2-Node-Zen2 (2n-zn2)
@@ -1800,15 +1372,6 @@ FD.io CSIT lab contains following server types:
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
-### 2-Node-ThunderX2 (2n-tx2)
-
-```
-- testbed211:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
- - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
-```
-
### 2-Node-Icelake (2n-icx)
```
@@ -1866,6 +1429,11 @@ FD.io CSIT lab contains following server types:
- ring5 200GE-ports ConnectX7-2p200GE:
- s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
- s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.
+```
+
+### 2-Node-Icelake (2n-oct)
+
+```
- testbed215:
- ring1 25GE-ports xxv710-DA2-2p25GE:
- s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
@@ -1892,19 +1460,6 @@ FD.io CSIT lab contains following server types:
To be completed.
```
-### 3-Node-Taishan (3n-tsh)
-
-```
-- testbed33:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
- - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
- - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
- - ring2 25GE-ports cx4-2p25GE on SUTs:
- - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
- - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
- - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
-```
### 3-Node-Altra (3n-alt)