aboutsummaryrefslogtreecommitdiffstats
path: root/docs/content
diff options
context:
space:
mode:
authorpmikus <peter.mikus@protonmail.ch>2023-03-27 11:02:38 +0000
committerpmikus <peter.mikus@protonmail.ch>2023-03-27 11:02:38 +0000
commit12992a674d186f437bd29b854c0031a092097def (patch)
tree80d43dc013362690a291e69612ec2d258bf1a6c0 /docs/content
parent9e86c76e6f2dbd7094f2f4b32b40eb6aa53adc8a (diff)
feat(docs): Update Infrastructure
Signed-off-by: pmikus <peter.mikus@protonmail.ch> Change-Id: I0044e305dfe3fbd76f0e0f0f261e107b0f134650
Diffstat (limited to 'docs/content')
-rw-r--r--docs/content/infrastructure/fdio_csit_testbed_specifications.md221
-rw-r--r--docs/content/infrastructure/fdio_dc_vexxhost_inventory.md33
-rw-r--r--docs/content/infrastructure/testbed_configuration/ami_alt_hw_bios_cfg.md1252
-rw-r--r--docs/content/infrastructure/testbed_configuration/gigabyte_tx2_hw_bios_cfg.md394
-rw-r--r--docs/content/infrastructure/testbed_configuration/huawei_tsh_hw_bios_cfg.md522
-rw-r--r--docs/content/introduction/bash_code_style.md6
-rw-r--r--docs/content/introduction/testing_in_vagrant.md4
7 files changed, 2310 insertions, 122 deletions
diff --git a/docs/content/infrastructure/fdio_csit_testbed_specifications.md b/docs/content/infrastructure/fdio_csit_testbed_specifications.md
index 49b6d72fa9..0711477a26 100644
--- a/docs/content/infrastructure/fdio_csit_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_csit_testbed_specifications.md
@@ -11,6 +11,30 @@ weight: 2
This note includes specification of the physical testbed infrastructure
hosted by LFN FD.io CSIT project.
+## Server Management
+
+### Addressing
+
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
+Management port, which are connected to two different VLANs.
+
+#### LOM (IPMI) VLAN
+
+ - Subnet: 10.30.50.0/24
+ - Gateway: 10.30.50.1
+ - Broadcast: 10.30.50.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+
+#### Management VLAN
+ - Subnet: 10.30.51.0/24
+ - Gateway: 10.30.51.1
+ - Broadcast: 10.30.51.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+
+To access these hosts, VPN connection is required.
+
## Testbeds Overview
### Summary List
@@ -139,37 +163,31 @@ one TG (Server-Type-H6) connected in a 2-node circular topology. For more
detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
Used for FD.io performance tests.
-## Server Management
-
-### Addressing
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
-Management port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
- - Subnet: 10.30.50.0/24
- - Gateway: 10.30.50.1
- - Broadcast: 10.30.50.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-2. Management Vlan:
- - Subnet: 10.30.51.0/24
- - Gateway: 10.30.51.1
- - Broadcast: 10.30.51.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-```
+## Tesdtbed Naming Convention
-To access these hosts, VPN connection is required.
+Following naming convention is used within this page to specify physical
+connectivity and wiring across defined CSIT testbeds:
-## Server Specifications
+- **testbedname**: testbedN.
+- **hostname**:
+ - traffic-generator: tN-tgW.
+ - system-under-testX: tN-sutX.
+- **portnames**:
+ - tN-tgW-cY/pZ.
+ - tN-sutX-cY/pZ.
+- **where**:
+ - N - testbed number.
+ - tgW - server acts as traffic-generator with W index.
+ - sutX - server acts as system-under-test with X index.
+ - Y - PCIe slot number denoting a NIC card number within the host.
+ - Z - port number on the NIC card.
-### Server Types
+## Server Types
FD.io CSIT lab contains following server types:
-```
-1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
+
+1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -188,7 +206,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+
+2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -208,7 +227,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+
+3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- Quantity: 1.
- Physical connectivity:
- Host management interface: 10/100/1000-BaseT.
@@ -227,7 +247,8 @@ FD.io CSIT lab contains following server types:
- Port-2: 10GE SFP+.
- Port-3: 10GE SFP+.
- Port-4: 10GE SFP+.
-4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+
+4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -267,7 +288,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+
+6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
@@ -287,7 +309,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+
+7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -307,7 +330,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+
+8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -323,7 +347,8 @@ FD.io CSIT lab contains following server types:
- no cards.
- Numa1:
- no cards.
-9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+
+9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -338,7 +363,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+
+10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -353,7 +379,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
-11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+
+11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -371,7 +398,8 @@ FD.io CSIT lab contains following server types:
- Numa1:
- PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+
+12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI(?) and host management ports.
@@ -384,7 +412,8 @@ FD.io CSIT lab contains following server types:
- NICs configuration:
- PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+
+13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
@@ -400,7 +429,8 @@ FD.io CSIT lab contains following server types:
- no cards
- Numa1:
- PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+
+14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -417,7 +447,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
- Numa1:
- no cards.
-15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -428,7 +458,8 @@ FD.io CSIT lab contains following server types:
- Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
- RAM Memory: 12* 16GB DDR4-3200MT/s
- Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+
+16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
@@ -448,7 +479,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+
+17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 8.
- Physical connectivity:
- IPMI and host management ports.
@@ -468,7 +500,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+
+18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -488,7 +521,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+
+19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -508,7 +542,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -528,7 +562,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 d8:00.xx: empty.
-21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+
+21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -542,7 +577,8 @@ FD.io CSIT lab contains following server types:
- NICs configuration:
- Numa0: (x16, PCIe3.0 lane)
- PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+
+22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -562,7 +598,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+
+23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -582,7 +619,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: empty.
-24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+
+24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -602,7 +640,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+
+25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -622,7 +661,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: empty.
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+
+26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -642,7 +682,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: empty.
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+
+27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -662,34 +703,10 @@ FD.io CSIT lab contains following server types:
- PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
- - traffic-generator: tN-tgW.
- - system-under-testX: tN-sutX.
-- portnames:
- - tN-tgW-cY/pZ.
- - tN-sutX-cY/pZ.
-- where:
- - N - testbed number.
- - tgW - server acts as traffic-generator with W index.
- - sutX - server acts as system-under-test with X index.
- - Y - PCIe slot number denoting a NIC card number within the host.
- - Z - port number on the NIC card.
-```
## Testbeds Configuration
-### Per Testbed Server Allocation and Naming
-
-#### 1-Node-Skylake Servers (1n-skx) PROD
+### 1-Node-Skylake (1n-skx)
```
- SUT [Server-Type-B6]:
@@ -722,7 +739,7 @@ connectivity and wiring across defined CSIT testbeds:
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
+### 1-Node-ThunderX2 (1n-tx2)
```
- SUT [Server-Type-E11]:
@@ -755,7 +772,7 @@ connectivity and wiring across defined CSIT testbeds:
- s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
```
-#### 1-Node-Cascadelake Servers (1n-clx) PROD
+### 1-Node-Cascadelake (1n-clx)
```
- SUT [Server-Type-C1]:
@@ -774,7 +791,7 @@ connectivity and wiring across defined CSIT testbeds:
- s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
+### 2-Node-IxiaPS1L47 (2n-ps1)
```
- SUT [Server-Type-B8]:
@@ -799,7 +816,7 @@ connectivity and wiring across defined CSIT testbeds:
- s26-t25-tg1-p4 - 10GE-port4.
```
-#### 2-Node-Cascadelake Servers (2n-clx) PROD
+### 2-Node-Cascadelake (2n-clx)
{{< figure src="/cdocs/testbed-2n-clx.svg" >}}
@@ -906,7 +923,7 @@ connectivity and wiring across defined CSIT testbeds:
- s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
-#### 2-Node-Zen2 Servers (2n-zn2) PROD
+### 2-Node-Zen2 (2n-zn2)
{{< figure src="/cdocs/testbed-2n-zn2.svg" >}}
@@ -941,7 +958,7 @@ connectivity and wiring across defined CSIT testbeds:
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
+### 2-Node-ThunderX2 (2x-tx2)
{{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
@@ -974,7 +991,7 @@ connectivity and wiring across defined CSIT testbeds:
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Icelake Servers (2n-icx) PROD
+### 2-Node-Icelake (2n-icx)
{{< figure src="/cdocs/testbed-2n-icx.svg" >}}
@@ -1101,7 +1118,7 @@ connectivity and wiring across defined CSIT testbeds:
- s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Rangeley Servers (3n-rng) VERIFY
+### 3-Node-Rangeley (3n-rng)
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
@@ -1135,7 +1152,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- 1GB ports (tbd)
```
-#### 3-Node-Taishan Servers (3n-tsh) PROD
+### 3-Node-Taishan (3n-tsh)
{{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
@@ -1180,7 +1197,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Altra Servers (3n-alt) PROD
+### 3-Node-Altra (3n-alt)
{{< figure src="/cdocs/testbed-3n-alt.svg" >}}
@@ -1219,7 +1236,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Icelake Servers (3n-icx) PROD
+### 3-Node-Icelake (3n-icx)
{{< figure src="/cdocs/testbed-3n-icx.svg" >}}
@@ -1310,7 +1327,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-SnowRidge Servers (3n-snr) PROD
+### 3-Node-SnowRidge (3n-snr)
{{< figure src="/cdocs/testbed-3n-snr.svg" >}}
@@ -1347,7 +1364,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
```
-#### 2-Node-SapphireRapids Servers (2n-spr) PROD
+### 2-Node-SapphireRapids (2n-spr)
{{< figure src="/cdocs/testbed-2n-spr.svg" >}}
@@ -1482,9 +1499,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-### Per Testbed Wiring
+## Testbed Wiring
-#### 1-Node-Skylake Wiring (1n-skx) PROD
+### 1-Node-Skylake (1n-skx)
```
- testbed11:
@@ -1515,7 +1532,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
```
-#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
+### 1-Node-ThunderX2 (1n-tx2)
```
- testbed13:
@@ -1539,7 +1556,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
-#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
+### 2-Node-IxiaPS1L47 (2n-ps1)
```
- testbed25:
@@ -1553,7 +1570,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- t25-tg1-p4 to t25-sut1-c2/p4.
```
-#### 2-Node-Cascadelake Wiring (2n-clx) PROD
+### 2-Node-Cascadelake (2n-clx)
```
- testbed27:
@@ -1612,7 +1629,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```
-#### 2-Node-Zen2 Wiring (2n-zn2) PROD
+### 2-Node-Zen2 (2n-zn2)
```
- testbed210:
@@ -1630,7 +1647,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
-#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
+### 2-Node-ThunderX2 (2n-tx2)
```
- testbed211:
@@ -1639,7 +1656,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
```
-#### 2-Node-Icelake Wiring (2n-icx) PROD
+### 2-Node-Icelake (2n-icx)
```
- testbed212:
@@ -1704,13 +1721,13 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
```
-#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
+### 3-Node-Rangeley (3n-rng)
```
To be completed.
```
-#### 3-Node-Taishan Wiring (3n-tsh) PROD
+### 3-Node-Taishan (3n-tsh)
```
- testbed33:
@@ -1724,7 +1741,7 @@ To be completed.
- s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
```
-#### 3-Node-Altra Wiring (3n-alt) PROD
+### 3-Node-Altra (3n-alt)
```
- testbed34:
@@ -1734,7 +1751,7 @@ To be completed.
- s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
```
-#### 3-Node-Icelake Wiring (3n-icx) PROD
+### 3-Node-Icelake (3n-icx)
```
- testbed37:
@@ -1771,7 +1788,7 @@ To be completed.
- s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
```
-#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+### 3-Node-SnowRidge (3n-snr)
```
- testbed39:
@@ -1784,7 +1801,7 @@ To be completed.
- s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
```
-#### 2-Node-SapphireRapids Wiring (2n-spr) PROD
+### 2-Node-SapphireRapids (2n-spr)
```
- testbed21:
diff --git a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
index 3bdca72dae..528101fd3c 100644
--- a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
+++ b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
@@ -5,26 +5,29 @@ weight: 1
# FD.io DC Vexxhost Inventory
-- captured inventory data: name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
- - name: CSIT functional server name as tracked in [CSIT testbed specification](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md), followed by "/" and the actual configured hostname, unless it is the same as CSIT name.
- - oper-status: operational status (up|down).
- - testbed-id: CSIT testbed identifier.
- - role: 2n/3n-xxx performance testbed, nomad-client, nomad-server.
+Captured inventory data:
+ - **name**: CSIT functional server name as tracked in
+ [CSIT testbed specification]({{< ref "fdio_csit_testbed_specifications#FD.io CSIT Testbed Specifications" >}}),
+ followed by "/" and the actual configured hostname, unless it is the same
+ as CSIT name.
+ - **oper-status**: operational status (up|down).
+ - **testbed-id**: CSIT testbed identifier.
+ - **role**: 2n/3n-xxx performance testbed, nomad-client, nomad-server.
- role exceptions: decommission, repurpose, spare.
- - model: server model.
- - s/n: serial number.
- - mgmt-ip4: current management IPv4 address on management VLAN.
- - ipmi-ip4: current IPMI IPv4 address on LOM VLAN.
- - rackid: new location rack id.
- - rackunit: new location rack unit id.
+ - **model**: server model.
+ - **s/n**: serial number.
+ - **mgmt-ip4**: current management IPv4 address on management VLAN.
+ - **ipmi-ip4**: current IPMI IPv4 address on LOM VLAN.
+ - **rackid**: new location rack id.
+ - **rackunit**: new location rack unit id.
## Missing Equipment Inventory
1. Ixia PerfectStorm One Appliance
- - [Specification: Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n554)
- - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017)
- - [mgmt-ip4 10.30.51.62 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n374)
- - [ipmi-ip4 10.30.50.59 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n281)
+ - [**Specification**]({{< ref "fdio_csit_testbed_specifications#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1" >}})
+ - [**Wiring**]({{< ref "fdio_csit_testbed_specifications#2-node-ixiaps1l47-2n-ps1" >}})
+ - **mgmt-ip4**: 10.30.51.62 s26-t25-tg1
+ - **ipmi-ip4**: 10.30.50.59 s26-t25-tg1
## YUL1 Inventory
diff --git a/docs/content/infrastructure/testbed_configuration/ami_alt_hw_bios_cfg.md b/docs/content/infrastructure/testbed_configuration/ami_alt_hw_bios_cfg.md
index e02c642e6e..d36d075e12 100644
--- a/docs/content/infrastructure/testbed_configuration/ami_alt_hw_bios_cfg.md
+++ b/docs/content/infrastructure/testbed_configuration/ami_alt_hw_bios_cfg.md
@@ -5,6 +5,1258 @@ title: "MegaRac Altra"
# MegaRac Altra
+## Linux lscpu
+
+```
+Architecture: aarch64
+ CPU op-mode(s): 32-bit, 64-bit
+ Byte Order: Little Endian
+CPU(s): 160
+ On-line CPU(s) list: 0-159
+Vendor ID: ARM
+ Model name: Neoverse-N1
+ Model: 1
+ Thread(s) per core: 1
+ Core(s) per socket: 80
+ Socket(s): 2
+ Stepping: r3p1
+ Frequency boost: disabled
+ CPU max MHz: 3000.0000
+ CPU min MHz: 1000.0000
+ BogoMIPS: 50.00
+ Flags: fp asimd evtstrm aes pmull sha1 sha2 crc32 atomics fphp asimdhp cpuid asimdrdm lrcpc dcpop asimddp ssbs
+Caches (sum of all):
+ L1d: 10 MiB (160 instances)
+ L1i: 10 MiB (160 instances)
+ L2: 160 MiB (160 instances)
+NUMA:
+ NUMA node(s): 2
+ NUMA node0 CPU(s): 0-79
+ NUMA node1 CPU(s): 80-159
+Vulnerabilities:
+ Itlb multihit: Not affected
+ L1tf: Not affected
+ Mds: Not affected
+ Meltdown: Not affected
+ Mmio stale data: Not affected
+ Retbleed: Not affected
+ Spec store bypass: Mitigation; Speculative Store Bypass disabled via prctl
+ Spectre v1: Mitigation; __user pointer sanitization
+ Spectre v2: Mitigation; CSV2, BHB
+ Srbds: Not affected
+ Tsx async abort: Not affected
+```
+
+## Linux dmidecode
+
+```
+# dmidecode 3.3
+Getting SMBIOS data from sysfs.
+SMBIOS 3.3.0 present.
+Table at 0xB1E10000.
+
+Handle 0x0000, DMI type 0, 26 bytes
+BIOS Information
+ Vendor: Ampere(R)
+ Version: 1.07.20210713 (SCP: 1.07.20210713)
+ Release Date: 2021/07/13
+ ROM Size: 7680 kB
+ Characteristics:
+ PCI is supported
+ BIOS is upgradeable
+ Boot from CD is supported
+ Selectable boot is supported
+ ACPI is supported
+ UEFI is supported
+ BIOS Revision: 5.15
+ Firmware Revision: 1.7
+
+Handle 0x0001, DMI type 1, 27 bytes
+System Information
+ Manufacturer: WIWYNN
+ Product Name: Mt.Jade Server System B81.030Z1.0007
+ Version: DVT
+ Serial Number: B81030Z1000704000059N0SC
+ UUID: 57c97bbe-008e-368f-19d0-595df92c6de0
+ Wake-up Type: Power Switch
+ SKU Number: NULL
+ Family: Altra
+
+Handle 0x0002, DMI type 2, 15 bytes
+Base Board Information
+ Manufacturer: WIWYNN
+ Product Name: Mt.Jade Motherboard
+ Version: B81.03010.0033
+ Serial Number: B8103010003303800033J0SA
+ Asset Tag: NULL
+ Features:
+ Board is a hosting board
+ Location In Chassis: Part Component
+ Chassis Handle: 0x0003
+ Type: Motherboard
+ Contained Object Handles: 0
+
+Handle 0x0003, DMI type 3, 22 bytes
+Chassis Information
+ Manufacturer: WIWYNN
+ Type: Rack Mount Chassis
+ Lock: Present
+ Version: B60.03008.0001
+ Serial Number: 04000059N0SC
+ Asset Tag: NULL
+ Boot-up State: Safe
+ Power Supply State: Safe
+ Thermal State: Safe
+ Security Status: None
+ OEM Information: 0x00000000
+ Height: Unspecified
+ Number Of Power Cords: 1
+ Contained Elements: 0
+ SKU Number: Unknown
+```
+
+## Linux dmidecode memory
+
+```
+Handle 0x0020, DMI type 16, 23 bytes
+Physical Memory Array
+ Location: System Board Or Motherboard
+ Use: System Memory
+ Error Correction Type: Multi-bit ECC
+ Maximum Capacity: 4 TB
+ Error Information Handle: No Error
+ Number Of Devices: 16
+
+Handle 0x0026, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 1
+ Bank Locator: Bank 1
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0197198A
+ Asset Tag: Array 1 Asset Tag 1
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0028, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0029
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 2
+ Bank Locator: Bank 2
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 2
+ Serial Number: Array 1 Serial Number 2
+ Asset Tag: Array 1 Asset Tag 2
+ Part Number: Array 1 Part Number 2
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0030, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 3
+ Bank Locator: Bank 3
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971992
+ Asset Tag: Array 1 Asset Tag 3
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0032, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0033
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 4
+ Bank Locator: Bank 4
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 4
+ Serial Number: Array 1 Serial Number 4
+ Asset Tag: Array 1 Asset Tag 4
+ Part Number: Array 1 Part Number 4
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0034, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 5
+ Bank Locator: Bank 5
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971989
+ Asset Tag: Array 1 Asset Tag 5
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0036, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0037
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 6
+ Bank Locator: Bank 6
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 6
+ Serial Number: Array 1 Serial Number 6
+ Asset Tag: Array 1 Asset Tag 6
+ Part Number: Array 1 Part Number 6
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0038, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 7
+ Bank Locator: Bank 7
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971BA1
+ Asset Tag: Array 1 Asset Tag 7
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0040, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0041
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 8
+ Bank Locator: Bank 8
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 8
+ Serial Number: Array 1 Serial Number 8
+ Asset Tag: Array 1 Asset Tag 8
+ Part Number: Array 1 Part Number 8
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0042, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 9
+ Bank Locator: Bank 9
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971930
+ Asset Tag: Array 1 Asset Tag 9
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0044, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0045
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 10
+ Bank Locator: Bank 10
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 10
+ Serial Number: Array 1 Serial Number 10
+ Asset Tag: Array 1 Asset Tag 10
+ Part Number: Array 1 Part Number 10
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0046, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 11
+ Bank Locator: Bank 11
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971BA2
+ Asset Tag: Array 1 Asset Tag 11
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0048, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0049
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 12
+ Bank Locator: Bank 12
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 12
+ Serial Number: Array 1 Serial Number 12
+ Asset Tag: Array 1 Asset Tag 12
+ Part Number: Array 1 Part Number 12
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0050, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 13
+ Bank Locator: Bank 13
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971957
+ Asset Tag: Array 1 Asset Tag 13
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0052, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0053
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 14
+ Bank Locator: Bank 14
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 14
+ Serial Number: Array 1 Serial Number 14
+ Asset Tag: Array 1 Asset Tag 14
+ Part Number: Array 1 Part Number 14
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0054, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 15
+ Bank Locator: Bank 15
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971B9E
+ Asset Tag: Array 1 Asset Tag 15
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0056, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0020
+ Error Information Handle: 0x0057
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM 16
+ Bank Locator: Bank 16
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 16
+ Serial Number: Array 1 Serial Number 16
+ Asset Tag: Array 1 Asset Tag 16
+ Part Number: Array 1 Part Number 16
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0071, DMI type 16, 23 bytes
+Physical Memory Array
+ Location: System Board Or Motherboard
+ Use: System Memory
+ Error Correction Type: Multi-bit ECC
+ Maximum Capacity: 4 TB
+ Error Information Handle: No Error
+ Number Of Devices: 16
+
+Handle 0x0077, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 1
+ Bank Locator: Bank 1
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971918
+ Asset Tag: Array 1 Asset Tag 1
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x007A, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x007C
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 2
+ Bank Locator: Bank 2
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 2
+ Serial Number: Array 1 Serial Number 2
+ Asset Tag: Array 1 Asset Tag 2
+ Part Number: Array 1 Part Number 2
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x007D, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 3
+ Bank Locator: Bank 3
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971970
+ Asset Tag: Array 1 Asset Tag 3
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0080, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x0082
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 4
+ Bank Locator: Bank 4
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 4
+ Serial Number: Array 1 Serial Number 4
+ Asset Tag: Array 1 Asset Tag 4
+ Part Number: Array 1 Part Number 4
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0083, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 5
+ Bank Locator: Bank 5
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971993
+ Asset Tag: Array 1 Asset Tag 5
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0086, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x0088
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 6
+ Bank Locator: Bank 6
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 6
+ Serial Number: Array 1 Serial Number 6
+ Asset Tag: Array 1 Asset Tag 6
+ Part Number: Array 1 Part Number 6
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0089, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 7
+ Bank Locator: Bank 7
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971985
+ Asset Tag: Array 1 Asset Tag 7
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x008C, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x008E
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 8
+ Bank Locator: Bank 8
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 8
+ Serial Number: Array 1 Serial Number 8
+ Asset Tag: Array 1 Asset Tag 8
+ Part Number: Array 1 Part Number 8
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x008F, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 9
+ Bank Locator: Bank 9
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971917
+ Asset Tag: Array 1 Asset Tag 9
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0092, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x0094
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 10
+ Bank Locator: Bank 10
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 10
+ Serial Number: Array 1 Serial Number 10
+ Asset Tag: Array 1 Asset Tag 10
+ Part Number: Array 1 Part Number 10
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0095, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 11
+ Bank Locator: Bank 11
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971984
+ Asset Tag: Array 1 Asset Tag 11
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x0098, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x009A
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 12
+ Bank Locator: Bank 12
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 12
+ Serial Number: Array 1 Serial Number 12
+ Asset Tag: Array 1 Asset Tag 12
+ Part Number: Array 1 Part Number 12
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x009B, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 13
+ Bank Locator: Bank 13
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971B37
+ Asset Tag: Array 1 Asset Tag 13
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x009E, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x00A0
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 14
+ Bank Locator: Bank 14
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 14
+ Serial Number: Array 1 Serial Number 14
+ Asset Tag: Array 1 Asset Tag 14
+ Part Number: Array 1 Part Number 14
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x00A1, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: No Error
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 8 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 15
+ Bank Locator: Bank 15
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 3200 MT/s
+ Manufacturer: Samsung
+ Serial Number: 01971C99
+ Asset Tag: Array 1 Asset Tag 15
+ Part Number: M393A1K43DB2-CWE
+ Rank: 1
+ Configured Memory Speed: 3200 MT/s
+ Minimum Voltage: 1.14 V
+ Maximum Voltage: 1.26 V
+ Configured Voltage: 1.2 V
+ Memory Technology: DRAM
+ Memory Operating Mode Capability: None
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Bank 1, Hex 0xCE
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: 8 GB
+ Cache Size: None
+ Logical Size: None
+
+Handle 0x00A4, DMI type 17, 92 bytes
+Memory Device
+ Array Handle: 0x0071
+ Error Information Handle: 0x00A6
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: Socket 1 DIMM 16
+ Bank Locator: Bank 16
+ Type: Unknown
+ Type Detail: Unknown
+ Speed: Unknown
+ Manufacturer: Array 1 Manufacturer 16
+ Serial Number: Array 1 Serial Number 16
+ Asset Tag: Array 1 Asset Tag 16
+ Part Number: Array 1 Part Number 16
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+ Memory Technology: Unknown
+ Memory Operating Mode Capability: Unknown
+ Firmware Version: Not Specified
+ Module Manufacturer ID: Unknown
+ Module Product ID: Unknown
+ Memory Subsystem Controller Manufacturer ID: Unknown
+ Memory Subsystem Controller Product ID: Unknown
+ Non-Volatile Size: None
+ Volatile Size: None
+ Cache Size: None
+ Logical Size: None
+```
+
## Linux cmdline
```
diff --git a/docs/content/infrastructure/testbed_configuration/gigabyte_tx2_hw_bios_cfg.md b/docs/content/infrastructure/testbed_configuration/gigabyte_tx2_hw_bios_cfg.md
index eb188d3bf9..5020cb70f9 100644
--- a/docs/content/infrastructure/testbed_configuration/gigabyte_tx2_hw_bios_cfg.md
+++ b/docs/content/infrastructure/testbed_configuration/gigabyte_tx2_hw_bios_cfg.md
@@ -5,6 +5,400 @@ title: "GigaByte ThunderX2"
# GigaByte ThunderX2
+## Linux lscpu
+
+```
+Architecture: aarch64
+ CPU op-mode(s): 64-bit
+ Byte Order: Little Endian
+CPU(s): 56
+ On-line CPU(s) list: 0-55
+Vendor ID: Cavium
+ Model name: ThunderX2 99xx
+ Model: 1
+ Thread(s) per core: 1
+ Core(s) per socket: 28
+ Socket(s): 2
+ Stepping: 0x1
+ Frequency boost: disabled
+ CPU max MHz: 2000.0000
+ CPU min MHz: 1000.0000
+ BogoMIPS: 400.00
+ Flags: fp asimd evtstrm aes pmull sha1 sha2 crc32 atomics cpuid asimdrdm
+Caches (sum of all):
+ L1d: 1.8 MiB (56 instances)
+ L1i: 1.8 MiB (56 instances)
+ L2: 14 MiB (56 instances)
+ L3: 64 MiB (2 instances)
+NUMA:
+ NUMA node(s): 2
+ NUMA node0 CPU(s): 0-27
+ NUMA node1 CPU(s): 28-55
+Vulnerabilities:
+ Itlb multihit: Not affected
+ L1tf: Not affected
+ Mds: Not affected
+ Meltdown: Not affected
+ Mmio stale data: Not affected
+ Retbleed: Not affected
+ Spec store bypass: Vulnerable
+ Spectre v1: Mitigation; __user pointer sanitization
+ Spectre v2: Vulnerable
+ Srbds: Not affected
+ Tsx async abort: Not affected
+```
+
+## Linux dmidecode
+
+```
+# dmidecode 3.3
+Getting SMBIOS data from sysfs.
+SMBIOS 3.1.1 present.
+Table at 0xFE340000.
+
+Handle 0x0000, DMI type 0, 26 bytes
+BIOS Information
+ Vendor: GIGABYTE
+ Version: F28
+ Release Date: 12/27/2019
+ Address: 0xF0000
+ Runtime Size: 64 kB
+ ROM Size: 32 MB
+ Characteristics:
+ PCI is supported
+ BIOS is upgradeable
+ BIOS shadowing is allowed
+ Boot from CD is supported
+ Selectable boot is supported
+ BIOS ROM is socketed
+ ACPI is supported
+ BIOS boot specification is supported
+ Targeted content distribution is supported
+ UEFI is supported
+ BIOS Revision: 7.3
+
+Handle 0x0001, DMI type 1, 27 bytes
+System Information
+ Manufacturer: GIGABYTE
+ Product Name: R181-T90-00
+ Version: 0100
+ Serial Number: GIG7P9512A0022
+ UUID: 00000000-0000-0040-8000-e0d55eae7026
+ Wake-up Type: Power Switch
+ SKU Number: SABER SKU
+ Family: Server
+
+Handle 0x0002, DMI type 2, 15 bytes
+Base Board Information
+ Manufacturer: GIGABYTE
+ Product Name: MT91-FS1-00
+ Version: 01000100
+ Serial Number: IH6P8800035
+ Asset Tag: 01234567890123456789AB
+ Features:
+ Board is a hosting board
+ Board is replaceable
+ Location In Chassis: Default string
+ Chassis Handle: 0x0003
+ Type: Motherboard
+ Contained Object Handles: 0
+
+Handle 0x0003, DMI type 3, 22 bytes
+Chassis Information
+ Manufacturer: GIGABYTE
+ Type: Rack Mount Chassis
+ Lock: Not Present
+ Version: 1.0
+ Serial Number: K61186073100003
+ Asset Tag: 01234567890123456789AB
+ Boot-up State: Safe
+ Power Supply State: Safe
+ Thermal State: Safe
+ Security Status: None
+ OEM Information: 0x00000000
+ Height: Unspecified
+ Number Of Power Cords: 1
+ Contained Elements: 0
+ SKU Number: Default string
+
+Handle 0x0004, DMI type 10, 6 bytes
+On Board Device Information
+ Type: Unknown
+ Status: Enabled
+ Description: Device 1
+
+Handle 0x0005, DMI type 12, 5 bytes
+System Configuration Options
+ Option 1: Default string
+
+Handle 0x0006, DMI type 13, 22 bytes
+BIOS Language Information
+ Language Description Format: Long
+ Installable Languages: 1
+ en|US|iso8859-1
+ Currently Installed Language: en|US|iso8859-1
+
+Handle 0x0007, DMI type 31, 28 bytes
+Boot Integrity Services Entry Point
+ Checksum: Invalid
+ 16-bit Entry Point Address: FFFF:FFFF
+ 32-bit Entry Point Address: 0xFFFFFFFF
+
+Handle 0x0008, DMI type 32, 11 bytes
+System Boot Information
+ Status: No errors detected
+
+Handle 0x0009, DMI type 39, 22 bytes
+System Power Supply
+ Power Unit Group: 1
+ Location: CHINA
+ Name: FSP1200-20ERM
+ Manufacturer: FSP GROUP
+ Serial Number: WS8011100823
+ Asset Tag: Default string
+ Model Part Number: FSP1200-20ERM
+ Revision: 10
+ Max Power Capacity: 2648 W
+ Status: Present, OK
+ Type: Switching
+ Input Voltage Range Switching: Auto-switch
+ Plugged: Yes
+ Hot Replaceable: No
+
+Handle 0x0010, DMI type 39, 22 bytes
+System Power Supply
+ Power Unit Group: 1
+ Location: CHINA
+ Name: FSP1200-20ERM
+ Manufacturer: FSP GROUP
+ Serial Number: WS8011100830
+ Asset Tag: Default string
+ Model Part Number: FSP1200-20ERM
+ Revision: 10
+ Max Power Capacity: 2648 W
+ Status: Present, OK
+ Type: Switching
+ Input Voltage Range Switching: Auto-switch
+ Plugged: Yes
+ Hot Replaceable: No
+
+Handle 0x0011, DMI type 41, 11 bytes
+Onboard Device
+ Reference Designation: Device 1
+ Type: Unknown
+ Status: Enabled
+ Type Instance: 1
+ Bus Address: 0000:00:00.0
+
+Handle 0x0012, DMI type 41, 11 bytes
+Onboard Device
+ Reference Designation: Device 2
+ Type: Unknown
+ Status: Enabled
+ Type Instance: 1
+ Bus Address: 0000:00:00.0
+
+Handle 0x0013, DMI type 41, 11 bytes
+Onboard Device
+ Reference Designation: Device 3
+ Type: Unknown
+ Status: Enabled
+ Type Instance: 1
+ Bus Address: 0000:00:00.0
+
+Handle 0x0014, DMI type 41, 11 bytes
+Onboard Device
+ Reference Designation: Device 4
+ Type: Unknown
+ Status: Enabled
+ Type Instance: 1
+ Bus Address: 0000:00:00.0
+
+Handle 0x0015, DMI type 41, 11 bytes
+Onboard Device
+ Reference Designation: Device 5
+ Type: Unknown
+ Status: Enabled
+ Type Instance: 1
+ Bus Address: 0000:00:00.0
+
+Handle 0x0016, DMI type 38, 18 bytes
+IPMI Device Information
+ Interface Type: SSIF (SMBus System Interface)
+ Specification Version: 2.0
+ I2C Slave Address: 0x10
+ NV Storage Device: Not Present
+ Base Address: 0x10 (SMBus)
+
+Handle 0x0017, DMI type 42, 12 bytes
+Management Controller Host Interface
+ Interface Type: OEM
+ Vendor ID: 0xFF0102FF
+
+Handle 0x0029, DMI type 11, 5 bytes
+OEM Strings
+ String 1: HWID=E38C
+ String 2: cavium.com
+ String 3: Saber
+
+Handle 0x002A, DMI type 13, 22 bytes
+BIOS Language Information
+ Language Description Format: Abbreviated
+ Installable Languages: 1
+ enUS
+ Currently Installed Language: enUS
+
+Handle 0x002B, DMI type 4, 48 bytes
+Processor Information
+ Socket Designation: Socket 0
+ Type: Central Processor
+ Family: ARM
+ Manufacturer: Cavium Inc.
+ ID: F1 0A 1F 43 00 00 00 00
+ Signature: Implementor 0x43, Variant 0x1, Architecture 15, Part 0x0af, Revision 1
+ Version: Cavium ThunderX2(R) CPU CN9975 v2.1 @ 2.0GHz
+ Voltage: 0.8 V
+ External Clock: 33 MHz
+ Max Speed: 2500 MHz
+ Current Speed: 2000 MHz
+ Status: Populated, Enabled
+ Upgrade: Other
+ L1 Cache Handle: 0x002C
+ L2 Cache Handle: 0x002E
+ L3 Cache Handle: 0x002F
+ Serial Number: 000081D4-4003326A
+ Asset Tag: Not Specified
+ Part Number: CN9975-2000BG4077-Y21-G
+ Core Count: 28
+ Core Enabled: 28
+ Thread Count: 28
+ Characteristics:
+ 64-bit capable
+ Multi-Core
+ Hardware Thread
+ Execute Protection
+ Enhanced Virtualization
+ Power/Performance Control
+```
+
+## Linux dmidecode memory
+
+```
+Handle 0x003E, DMI type 16, 23 bytes
+Physical Memory Array
+ Location: System Board Or Motherboard
+ Use: System Memory
+ Error Correction Type: Multi-bit ECC
+ Maximum Capacity: 2 TB
+ Error Information Handle: Not Provided
+ Number Of Devices: 12
+
+Handle 0x003F, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x003E
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 32 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM_P0_A0
+ Bank Locator: N0
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Micron Technology
+ Serial Number: 469570327
+ Asset Tag: Not Specified
+ Part Number: 36ASF4G72PZ-2G3B1
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 1.2 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0040, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x003E
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 32 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM_P0_B0
+ Bank Locator: N0
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Micron Technology
+ Serial Number: 469570172
+ Asset Tag: Not Specified
+ Part Number: 36ASF4G72PZ-2G3B1
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 1.2 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0050, DMI type 16, 23 bytes
+Physical Memory Array
+ Location: System Board Or Motherboard
+ Use: System Memory
+ Error Correction Type: Multi-bit ECC
+ Maximum Capacity: 2 TB
+ Error Information Handle: Not Provided
+ Number Of Devices: 12
+
+Handle 0x0051, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0050
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 32 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM_P1_I0
+ Bank Locator: N1
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Micron Technology
+ Serial Number: 469567519
+ Asset Tag: Not Specified
+ Part Number: 36ASF4G72PZ-2G3B1
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 1.2 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0052, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0050
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 32 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM_P1_J0
+ Bank Locator: N1
+ Type: DDR4
+ Type Detail: Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Micron Technology
+ Serial Number: 469567696
+ Asset Tag: Not Specified
+ Part Number: 36ASF4G72PZ-2G3B1
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 1.2 V
+ Configured Voltage: 1.2 V
+```
+
## Linux cmdline
```
diff --git a/docs/content/infrastructure/testbed_configuration/huawei_tsh_hw_bios_cfg.md b/docs/content/infrastructure/testbed_configuration/huawei_tsh_hw_bios_cfg.md
index d9fd71b080..6803fd615b 100644
--- a/docs/content/infrastructure/testbed_configuration/huawei_tsh_hw_bios_cfg.md
+++ b/docs/content/infrastructure/testbed_configuration/huawei_tsh_hw_bios_cfg.md
@@ -5,6 +5,528 @@ title: "Huawei Taishan"
# Huawei Taishan
+## Linux lscpu
+
+```
+Architecture: aarch64
+ CPU op-mode(s): 32-bit, 64-bit
+ Byte Order: Little Endian
+CPU(s): 64
+ On-line CPU(s) list: 0-63
+Vendor ID: ARM
+ Model name: Cortex-A72
+ Model: 2
+ Thread(s) per core: 1
+ Core(s) per socket: 32
+ Socket(s): 2
+ Stepping: r0p2
+ BogoMIPS: 100.00
+ Flags: fp asimd evtstrm aes pmull sha1 sha2 crc32 cpuid
+Caches (sum of all):
+ L1d: 2 MiB (64 instances)
+ L1i: 3 MiB (64 instances)
+ L2: 16 MiB (16 instances)
+ L3: 64 MiB (4 instances)
+NUMA:
+ NUMA node(s): 4
+ NUMA node0 CPU(s): 0-15
+ NUMA node1 CPU(s): 16-31
+ NUMA node2 CPU(s): 32-47
+ NUMA node3 CPU(s): 48-63
+Vulnerabilities:
+ Itlb multihit: Not affected
+ L1tf: Not affected
+ Mds: Not affected
+ Meltdown: Not affected
+ Mmio stale data: Not affected
+ Retbleed: Not affected
+ Spec store bypass: Vulnerable
+ Spectre v1: Mitigation; __user pointer sanitization
+ Spectre v2: Vulnerable
+ Srbds: Not affected
+ Tsx async abort: Not affected
+```
+
+## Linux dmidecode
+
+```
+# dmidecode 3.3
+Getting SMBIOS data from sysfs.
+SMBIOS 3.0.0 present.
+Table at 0x39150000.
+
+Handle 0x0000, DMI type 0, 24 bytes
+BIOS Information
+ Vendor: Huawei Corp.
+ Version: Estuary-5.1 D05 LTS
+ Release Date: 05/25/2018
+ Address: 0xA4800
+ Runtime Size: 366 kB
+ ROM Size: 3 MB
+ Characteristics:
+ PCI is supported
+ BIOS is upgradeable
+ BIOS shadowing is allowed
+ Boot from CD is supported
+ Selectable boot is supported
+ EDD is supported
+ Japanese floppy for NEC 9800 1.2 MB is supported (int 13h)
+ Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
+ 5.25"/360 kB floppy services are supported (int 13h)
+ 5.25"/1.2 MB floppy services are supported (int 13h)
+ 3.5"/720 kB floppy services are supported (int 13h)
+ 3.5"/2.88 MB floppy services are supported (int 13h)
+ 8042 keyboard services are supported (int 9h)
+ CGA/mono video services are supported (int 10h)
+ ACPI is supported
+ USB legacy is supported
+ BIOS boot specification is supported
+ Targeted content distribution is supported
+ UEFI is supported
+ BIOS Revision: 0.0
+
+Handle 0x0001, DMI type 1, 27 bytes
+System Information
+ Manufacturer: Huawei
+ Product Name: D05
+ Version: VER.A
+ Serial Number: 2102311TBJ10J1000089
+ UUID: e11a0a38-f920-11e7-8c7d-a0a33bc11426
+ Wake-up Type: Power Switch
+ SKU Number: To be filled by O.E.M.
+ Family: To be filled by O.E.M.
+
+Handle 0x0002, DMI type 3, 25 bytes
+Chassis Information
+ Manufacturer: Huawei
+ Type: Main Server Chassis
+ Lock: Not Present
+ Version: To be filled by O.E.M.
+ Serial Number: To be filled by O.E.M.
+ Asset Tag: To be filled by O.E.M.
+ Boot-up State: Safe
+ Power Supply State: Safe
+ Thermal State: Safe
+ Security Status: None
+ OEM Information: 0x00000000
+ Height: 2 U
+ Number Of Power Cords: 1
+ Contained Elements: 0
+ SKU Number: Not Specified
+
+Handle 0x0003, DMI type 2, 17 bytes
+Base Board Information
+ Manufacturer: Huawei
+ Product Name: D05
+ Version: Estuary
+ Serial Number: 024APL10H8000089
+ Asset Tag: To be filled by O.E.M.
+ Features:
+ Board is a hosting board
+ Board is replaceable
+ Location In Chassis: To Be Filled By O.E.M.
+ Chassis Handle: 0x0002
+ Type: Motherboard
+ Contained Object Handles: 0
+```
+
+## Linux dmidecode memory
+
+```
+Handle 0x0007, DMI type 16, 23 bytes
+Physical Memory Array
+ Location: System Board Or Motherboard
+ Use: System Memory
+ Error Correction Type: None
+ Maximum Capacity: 512 GB
+ Error Information Handle: Not Provided
+ Number Of Devices: 16
+
+Handle 0x0009, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM000 J5
+ Bank Locator: SOCKET 0 CHANNEL 0 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x37663087
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x000A, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM001 J6
+ Bank Locator: SOCKET 0 CHANNEL 0 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x000B, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM010 J8
+ Bank Locator: SOCKET 0 CHANNEL 1 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x37663064
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x000C, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM011 J9
+ Bank Locator: SOCKET 0 CHANNEL 1 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x000D, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM020 J11
+ Bank Locator: SOCKET 0 CHANNEL 2 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x3766308B
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x000E, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM021 J12
+ Bank Locator: SOCKET 0 CHANNEL 2 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x000F, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM030 J14
+ Bank Locator: SOCKET 0 CHANNEL 3 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x376630DA
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0010, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM031 J15
+ Bank Locator: SOCKET 0 CHANNEL 3 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x0011, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM100 J17
+ Bank Locator: SOCKET 1 CHANNEL 0 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x379A2774
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0012, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM101 J18
+ Bank Locator: SOCKET 1 CHANNEL 0 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x0013, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM110 J20
+ Bank Locator: SOCKET 1 CHANNEL 1 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x3766308A
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0014, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM111 J21
+ Bank Locator: SOCKET 1 CHANNEL 1 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x0015, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM120 J23
+ Bank Locator: SOCKET 1 CHANNEL 2 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x376630B0
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0016, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM121 J24
+ Bank Locator: SOCKET 1 CHANNEL 2 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+
+Handle 0x0017, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: 72 bits
+ Data Width: 64 bits
+ Size: 16 GB
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM130 J26
+ Bank Locator: SOCKET 1 CHANNEL 3 DIMM 0
+ Type: DDR4
+ Type Detail: Synchronous Registered (Buffered)
+ Speed: 2400 MT/s
+ Manufacturer: Samsung
+ Serial Number: 0x376630A0
+ Asset Tag: Unknown
+ Part Number: M393A2K43BB1-CRC
+ Rank: 2
+ Configured Memory Speed: 2400 MT/s
+ Minimum Voltage: 1.2 V
+ Maximum Voltage: 2.0 V
+ Configured Voltage: 1.2 V
+
+Handle 0x0018, DMI type 17, 40 bytes
+Memory Device
+ Array Handle: 0x0007
+ Error Information Handle: Not Provided
+ Total Width: Unknown
+ Data Width: Unknown
+ Size: No Module Installed
+ Form Factor: DIMM
+ Set: None
+ Locator: DIMM131 J27
+ Bank Locator: SOCKET 1 CHANNEL 3 DIMM 1
+ Type: Unknown
+ Type Detail: Unknown Synchronous
+ Speed: Unknown
+ Manufacturer: NO DIMM
+ Serial Number: NO DIMM
+ Asset Tag: NO DIMM
+ Part Number: NO DIMM
+ Rank: Unknown
+ Configured Memory Speed: Unknown
+ Minimum Voltage: Unknown
+ Maximum Voltage: Unknown
+ Configured Voltage: Unknown
+```
+
## Linux cmdline
```
diff --git a/docs/content/introduction/bash_code_style.md b/docs/content/introduction/bash_code_style.md
index 1cc1464056..bbd0c37196 100644
--- a/docs/content/introduction/bash_code_style.md
+++ b/docs/content/introduction/bash_code_style.md
@@ -6,9 +6,9 @@ title: "Bash Code Style"
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED",
"MAY", and "OPTIONAL" in this document are to be interpreted as
-described in `BCP 14 <https://tools.ietf.org/html/bcp14>`_
-`[RFC2119] <https://tools.ietf.org/html/rfc2119>`_
-`[RFC8174] <https://tools.ietf.org/html/rfc8174>`_
+described in [BCP 14](https://tools.ietf.org/html/bcp14),
+[RFC2119](https://tools.ietf.org/html/rfc2119),
+[RFC8174](https://tools.ietf.org/html/rfc8174)
when, and only when, they appear in all capitals, as shown here.
This document SHALL describe guidelines for writing reliable, maintainable,
diff --git a/docs/content/introduction/testing_in_vagrant.md b/docs/content/introduction/testing_in_vagrant.md
index ef1e231393..34ca596d0a 100644
--- a/docs/content/introduction/testing_in_vagrant.md
+++ b/docs/content/introduction/testing_in_vagrant.md
@@ -22,8 +22,8 @@ Run all commands from command line.
VBoxManage --version
Tested version: 6.1.16r140961
-2. Download and install latest vagrant
- [from official page](https://www.vagrantup.com/downloads.html).
+2. Download and install latest vagrant from
+ [official page](https://www.vagrantup.com/downloads.html).
To verify the installtion, run
vagrant -v