aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md
diff options
context:
space:
mode:
authorMaciek Konstantynowicz <mkonstan@cisco.com>2019-02-27 21:27:04 +0000
committerMaciek Konstantynowicz <mkonstan@cisco.com>2019-03-06 14:35:38 +0000
commitddbfd9e68e81e77bd253c8b6cd81839ec3bd2715 (patch)
tree0f0216974f37b9b7953a4def38b9629bec8ebd7d /docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md
parenta1e7653789cf39773b717bb8dda0400d4683c96e (diff)
docs/lab: merged testbed specifications, separated out detailed HW and BIOS configs.
Change-Id: I5945723676361fdbe180a3bd5a6a366102ee6c67 Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md')
-rw-r--r--docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md1560
1 files changed, 0 insertions, 1560 deletions
diff --git a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md
deleted file mode 100644
index 3227ee09d4..0000000000
--- a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md
+++ /dev/null
@@ -1,1560 +0,0 @@
-## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
-
-This is a low-level design implemented as an extensions of FD.io CSIT lab to
-accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices.
-
-## Testbeds Overview
-
-### Testbeds Type Breakdown
-
-```
- #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node.
- 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2.
- 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8.
- 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6.
- 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1.
- 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1.
- 6. aarch64-d05 perf arm. skx. 1. 2. 1. 1/2.
- 7. aarch64-mcbin perf arm. skx. 1. 2. 1. 1/2.
- 8. 1-node aarch64 func arm. n/a. 1. 1. 0. 0.
- Total skx_node: 19.
-```
-
-### 1-Node Xeon Testbeds
-
-One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6
-server), with NIC ports connected back-to-back.
-
-### 2-Node Xeon Testbeds
-
-Four 2-node Xeon testbeds (are expected to be built|are built), with each
-testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected
-back-to-back. NIC cards placement into slots and NIC ports connectivity is
-following the testbed specification included in next sections.
-
-### 3-Node Xeon Testbeds
-
-Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed
-using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh
-triangle. NIC cards placement into slots and NIC ports connectivity is following
-the testbed specification included in next sections.
-
-### 1-Node Arm Marvell ThunderX2 Testbed
-
-One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using
-one SUT (Type-9 server), with NIC ports connected back-to-back.
-
-### 3-Node Arm Huawei TaiShan Testbed
-
-One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3
-server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards
-placement into slots and NIC ports connectivity is following the testbed
-specification included in next sections.
-
-### 3-Node Arm Marvell MACCHIATObin Testbed
-
-One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs
-(Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
-Built-in NIC ports connectivity is following the testbed specification included
-in next sections.
-
-### TCP/IP and L47 Testbeds
-
-One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
-
-### Atom Testbeds
-One 3-node Atom (Netgate based) testbed is built consisting of three SUTs
-(Type-5 Netgate device.) NIC cards placement into slots and NIC ports
-connectivity is following the testbed specification included in the next
-section.
-
-## Inventory
-
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
- - 1 * PS10GE4NG
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
-```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
- - 1 * ThunderX2
- - Chassis: Marvell ThunderX2
- - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - 2 * Huawei TaiShan 2280.
- - Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
- - RAM Memory: 8* 16GB DDR4-2400MT/s.
- - Disks: 1* 4TB SATA HDD.
- - 3 * MACCHIATObin
- - Chassis: MACCHIATObin.
- - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
- - RAM Memory: 1* 16GB DDR4.
- - Disks: 1* 128GB(?) SATA SDD.
-```
-
-Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro
-------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------
-[SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB | | openSUSE
- | | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB | | openSUSE
- | | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB | | openSUSE
-[Marvell ThunderX](https://www.marvell.com/server-processors/thunderx-arm-processors/) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
- | | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
- | | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
- | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad6arm | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
- | | VPP dev debug | Up | nomad7arm | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
- | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad8arm | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
- | | VPP dev debug | Up | nomad9arm | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
-[Marvell ThunderX2](https://www.marvell.com/server-processors/thunderx2-arm-processors/) | VPP device server | Being Provisioned | s27-t13-sut1 | 10.30.51.69 | 10.30.50.69 | 112 | 128GB | 3x40GbE QSFP+ XL710-QDA2 | Ubuntu 18.04.1
-Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
- | | CSIT Performance | Up, Manual perf experiments | s18-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
-[Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4
- | | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
- | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
-
-### Xeon and Atom Servers
-
-```
-1. Intel Xeon servers:
- - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
- - 3 * Netgate XG-2758-1u
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangely (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
- - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
- - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
- - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
-2. 25GE NICs
- - 12 * Intel® Ethernet Network Adapter XXV710-DA2
-3. 40GE NICs
- - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
-4. 100GE NICs
- - 4 * mcx556a-edat NICs (not on site yet, in transit)
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
- - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
- - 80 * 10G SR optic (generic, "Intel" compatible branded)
-2. 25GE SFP28
- - None
-3. 40GE QSFP+
- - None
-4. 100GE
- - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
-```
-
-Standalone cables:
-
-```
-1. 10GE
- - None
-2. 25GE
- - None
-3. 40GE QSFP+
- - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
-4. 100GE
- - None
-```
-
-### Other Network Cards
-
-Any QATs?
-
-## Installation Status
-
-Lab installation status is tracked by LF IT team in
-[FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
-
-## Server/Device Management and Naming
-
-### Server Management Requirements
-
-Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
-For management purposes, each server must have following two ports connected to
-the management network:
-
-```
-- 1GE IPMI port
- - IPMI - Intelligent Platform Management Interface.
- - Required for access to embedded server management with WebUI, CLI, SNMPv3,
- IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE management port
- - hostOS management port for general system management.
-```
-
-### Server and Port Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
- - traffic-generator: tN-tgW.
- - system-under-testX: tN-sutX.
-- portnames:
- - tN-tgW-cY/pZ.
- - tN-sutX-cY/pZ.
-- where:
- - N - testbed number.
- - tgW - server acts as traffic-generator with W index.
- - sutX - server acts as system-under-test with X index.
- - Y - PCIe slot number denoting a NIC card number within the host.
- - Y=2,4,9 - slots connected to NUMA node 0.
- - Y=6,8,10 - slots connected to NUMA node 1.
- - Z - port number on the NIC card.
-```
-
-### Server Management - Addressing
-
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
-port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
- - Subnet: 10.30.50.0/24
- - Gateway: 10.30.50.1
- - Broadcast: 10.30.50.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-2. Management Vlan:
- - Subnet: 10.30.51.0/24
- - Gateway: 10.30.51.1
- - Broadcast: 10.30.51.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-```
-
-To access these hosts, an VPN connection is required.
-
-### LOM (IPMI) VLAN IP Addresses
-..
-
-### Management VLAN IP Addresses
-..
-
-## Testbeds Specification - Target Build
-
-### Server/Ports Naming, NIC Placement
-
-#### 1-Node Xeon
-
-Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server1 [Type-6]:
- - testbedname: testbed11.
- - hostname: s1-t11-sut1.
- - IPMI IP: 10.30.50.47
- - Host IP: 10.30.51.50
- - portnames:
- - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- Server2 [Type-6]:
- - testbedname: testbed12.
- - hostname: s2-t12-sut1.
- - IPMI IP: 10.30.50.48
- - Host IP: 10.30.51.51
- - portnames:
- - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node Xeon
-
-Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server3 [Type-1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server4 [Type-2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server5 [Type-1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server6 [Type-2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server7 [Type-1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server8 [Type-2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server9 [Type-1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server10 [Type-2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 3-Node Xeon
-
-Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server11 [Type-1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
- - portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server12 [Type-1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
- - portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server13 [Type-2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
- - portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server14 [Type-1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
- - portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server15 [Type-1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
- - portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server16 [Type-2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
- - portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 1-Node Arm
-
-```
-- Server17 [Type-3]:
- - testbedname: testbed13.
- - hostname: s27-t13-sut1.
- - IPMI IP: 10.30.50.69
- - Host IP: 10.30.51.69
- - portnames:
- - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-```
-
-#### 3-Node Arm
-
-Note: Server19 (TG) is shared between testbed33 & testbed34
-
-```
-- Server17 [Type-3]:
- - testbedname: testbed33.
- - hostname: s17-t33-sut1.
- - IPMI IP: 10.30.50.36
- - Host IP: 10.30.51.36
- - portnames:
- - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
- - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
- - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- Server18 [Type-3]:
- - testbedname: testbed33.
- - hostname: s18-t33-sut2.
- - IPMI IP: 10.30.50.37
- - Host IP: 10.30.51.37
- - portnames:
- - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
- - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
- - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- Server19 [Type-2]:
- - testbednames: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- Server20 [Type-4]:
- - testbedname: testbed34.
- - hostname: s20-t34-sut1.
- - IPMI IP: N/A
- - Host IP: 10.30.51.41
- - portnames:
- - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
- - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- Server21 [Type-4]:
- - testbedname: testbed34.
- - hostname: s21-t34-sut2.
- - IPMI IP: N/A
- - Host IP: 10.30.51.42
- - portnames:
- - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
- - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
-```
-
-#### TCP/IP and L47
-
-Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and
-NIC cards and ports indexed per following specification:
-
-```
-- Server25 [Type-8]:
- - testbedname: testbed25.
- - hostname: s25-t25-sut1.
- - IPMI IP: 10.30.50.58
- - Host IP: 10.30.51.61
- - portnames:
- - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- Server26 [Type-7]:
- - testbedname: testbed25.
- - hostname: s26-t25-tg1.
- - IPMI IP: 10.30.50.59
- - Host IP: 10.30.51.62
- - portnames:
- - s26-t25-tg1-p1 - 10GE-port1.
- - s26-t25-tg1-p2 - 10GE-port2.
- - s26-t25-tg1-p3 - 10GE-port3.
- - s26-t25-tg1-p4 - 10GE-port4.
-```
-
-#### 3-Node Atom
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- Server22 [Type-5]:
- - testbedname: testbed35.
- - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
- - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
- - Host IP: 10.30.51.9
- - portnames:
- - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- Server23 [Type-5]:
- - testbedname: testbed35.
- - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
- - Host IP: 10.30.51.10
- - portnames:
- - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- Server24 [Type-5]:
- - testbedname: testbed35.
- - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
- - Host IP: 10.30.51.11
- - portnames:
- - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-```
-
-### Physical Connectivity within Testbeds
-
-#### 1-Node Xeon
-
-Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below
-specification:
-
-```
-- testbed11:
- - ring1 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
-- testbed12:
- - ring1 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
-```
-
-#### 2-Node Xeon
-
-Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below
-specification:
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
- - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
- - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
- - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
- - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
- - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
- - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
- - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
- - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
-#### 3-Node Xeon
-
-Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below
-specification:
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
-
-#### 1-Node Arm
-
-One 1-Node testbed is constructed by connecting 1 Arm server using below
-specification:
-
-```
-- testbed13:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
- - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
-```
-
-#### 3-Node Arm
-
-One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon
-server using below specification:
-
-```
-- testbed33:
- - ring1 10GE-ports 82599-2p10GE on SUTs:
- - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
- - t33-sut1-c6/p1 - t33-sut2-c6/p2.
- - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
- - ring2 25GE-ports cx4-2p25GE on SUTs:
- - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
- - t33-sut1-c4/p1 - t33-sut2-c4/p2.
- - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
-```
-
-One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one
-Xeon server using below specification:
-
-```
-- testbed34:
- - ring1 10GE-ports Marvell on SUTs:
- - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
- - t34-sut1-ca/p2 - t34-sut2-ca/p1.
- - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
-```
-
-#### TCP/IP and L47
-
-One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon
-server using below specification:
-
-```
-- testbed25:
- - link1 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p1 to t25-sut1-c2/p1.
- - link2 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p2 to t25-sut1-c2/p2.
- - link3 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p3 to t25-sut1-c2/p3.
- - link4 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-#### 3-Node Atom
-
-..
-
-## Server Specification
-
-### Hardware Configuration
-
-The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
-server configurations:
-
-```
-1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e.
- VPP, testpmd.
- - Quantity: TBD based on testbed allocation.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
- - Quantity: TBD based on testbed allocation.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload
- i.e. VPP, testpmd.
- - Quantity: 2
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
-4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload
- i.e. VPP, testpmd.
- - Quantity: 3
- - Physical connectivity:
- - Host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: MACCHIATObin.
- - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
- - RAM Memory: 1* 16GB DDR4
- - Disks: 1* 128GB(?) SATA SDD
- - NICs configuration:
- - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e.
- VPP, testpmd.
- - Quantity: TBD based on testbed allocation.
- - Physical connectivity:
- - Management: serial Port (usb) for console
- - NIC ports connected into 2-node.
- - Main HW configuration:
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
- - NICs configuration:
- - 2x 10Gb Intel 82599ES
- - 4x 1GB Intel I354
-6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance
- tests.
- - Quantity: 1.
- - Physical connectivity:
- - Host management interface: 10/100/1000-BaseT.
- - 8-port 10GE SFP+ integrated NIC.
- - Main HW configuration:
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
- - Interface configuration:
- - Port-1: 10GE SFP+.
- - Port-2: 10GE SFP+.
- - Port-3: 10GE SFP+.
- - Port-4: 10GE SFP+.
-8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional
- tests.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motheboard: MT91-FS1
- - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - PCIe Slot1 05:00.xx: XL710-QDA2.
- - PCIe Slot3 08:00.xx: XL710-QDA2.
- - Numa1:
- - PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane
- Workload i.e. VPP, testpmd.
- - Quantity: 4
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-E300-9A
- - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
- - RAM Memory: 32GB ECC
- - Disks: 480 GB
- - NICs configuration:
- - 2x 10Gb Intel x553 fiber ports
- - 2x 10Gb Intel x553 copper ports
- - 4x 1GB Intel I350 ports
-```
-
-### Xeon Skx Server BIOS Configuration
-
-#### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | Install Windows 7 USB support [Disabled] | |
- | Port 61h Bit-4 Emulation [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
- | Throttle on Power Fail [Disabled] | |
-```
-
-#### CPU Configuration
-
-```
- | Processor Configuration |Enables Hyper Threading |
- | -------------------------------------------------- |(Software Method to |
- | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
- | Processor Socket CPU1 | CPU2 |Processor threads. |
- | Processor ID 00050654* | 000506... | |
- | Processor Frequency 2.500GHz | 2.500GHz | |
- | Processor Max Ratio 19H | 19H | |
- | Processor Min Ratio 0AH | 0AH | |
- | Microcode Revision 02000030 | |
- | L1 Cache RAM 64KB | 64KB | |
- | L2 Cache RAM 1024KB | 1024KB | |
- | L3 Cache RAM 39424KB | 39424KB | |
- | Processor 0 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | Processor 1 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | | |
- | Hyper-Threading [ALL] [Enable] | |
- | Core Disable Bitmap(Hex) 0 | |
- | Execute Disable Bit [Enable] | |
- | Intel Virtualization Technology [Enable] | |
- | PPIN Control [Unlock/Enable] | |
- | Hardware Prefetcher [Enable] | |
- | Adjacent Cache Prefetch [Enable] | |
- | DCU Streamer Prefetcher [Enable] | |
- | DCU IP Prefetcher [Enable] | |
- | LLC Prefetch [Disable] | |
- | Extended APIC [Disable] | |
- | AES-NI [Enable] | |
- |> Advanced Power Management Configuration | |
-```
-
-##### Advanced Power Management Configuration
-
-```
- | Advanced Power Management Configuration |Switch CPU Power Management |
- | -------------------------------------------------- |profile |
- | Power Technology [Custom] | |
- | Power Performance Tuning [BIOS Controls EPB] | |
- | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
- |> CPU P State Control | |
- |> Hardware PM State Control | |
- |> CPU C State Control | |
- |> Package C State Control | |
- |> CPU T State Control | |
-```
-
-###### CPU P State Control
-
-```
- | CPU P State Control |Enable/Disable EIST |
- | |(P-States) |
- | SpeedStep (Pstates) [Disable] | |
- | EIST PSD Function [HW_ALL] | |
-```
-
-###### Hardware PM State Control
-
-```
- | Hardware PM State Control |Disable: Hardware chooses a |
- | |P-state based on OS Request |
- | Hardware P-States [Disable] |(Legacy P-States) |
- | |Native Mode:Hardware |
- | |chooses a P-state based on |
- | |OS guidance |
- | |Out of Band Mode:Hardware |
- | |autonomously chooses a |
- | |P-state (no OS guidance) |
-```
-
-###### CPU C State Control
-
-```
- | CPU C State Control |Autonomous Core C-State |
- | |Control |
- | Autonomous Core C-State [Disable] | |
- | CPU C6 report [Disable] | |
- | Enhanced Halt State (C1E) [Disable] | |
-```
-
-###### Package C State Control
-
-```
- | Package C State Control |Package C State limit |
- | | |
- | Package C State [C0/C1 state] | |
-```
-
-###### CPU T State Control
-
-```
- | CPU T State Control |Enable/Disable Software |
- | |Controlled T-States |
- | Software Controlled T-States [Disable] | |
-```
-
-##### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge | |
- |> South Bridge | |
-```
-
-###### North Bridge
-
-```
- |> UPI Configuration |Displays and provides |
- |> Memory Configuration |option to change the UPI |
- |> IIO Configuration |Settings |
-```
-
-###### UPI Configuration
-
-```
- | UPI Configuration |Choose Topology Precedence |
- | -------------------------------------------------- |to degrade features if |
- | Number of CPU 2 |system options are in |
- | Number of Active UPI Link 3 |conflict or choose Feature |
- | Current UPI Link Speed Fast |Precedence to degrade |
- | Current UPI Link Frequency 10.4 GT/s |topology if system options |
- | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
- | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
- | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
- | Degrade Precedence [Topology Precedence] | |
- | Link L0p Enable [Disable] | |
- | Link L1 Enable [Disable] | |
- | IO Directory Cache (IODC) [Auto] | |
- | SNC [Disable] | |
- | XPT Prefetch [Disable] | |
- | KTI Prefetch [Enable] | |
- | Local/Remote Threshold [Auto] | |
- | Stale AtoS [Disable] | |
- | LLC dead line alloc [Enable] | |
- | Isoc Mode [Auto] | |
-```
-
-###### Memory Configuration
-
-```
- | |POR - Enforces Plan Of |
- | -------------------------------------------------- |Record restrictions for |
- | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
- | -------------------------------------------------- |programming. Disable - |
- | |Disables this feature. |
- | Enforce POR [Disable] | |
- | Memory Frequency [2666] | |
- | Data Scrambling for NVMDIMM [Auto] | |
- | Data Scrambling for DDR4 [Auto] | |
- | tCCD_L Relaxation [Auto] | |
- | Memory tRWSR Relaxation [Enable] | |
- | 2X REFRESH [Auto] | |
- | Page Policy [Auto] | |
- | IMC Interleaving [2-way Interleave] | |
- |> Memory Topology | |
- |> Memory RAS Configuration | |
-```
-
-###### IIO Configuration
-
-```
- | IIO Configuration |Expose IIO DFX devices and |
- | -------------------------------------------------- |other CPU devices like PMON |
- | | |
- | EV DFX Features [Disable] | |
- |> CPU1 Configuration | |
- |> CPU2 Configuration | |
- |> IOAT Configuration | |
- |> Intel. VT for Directed I/O (VT-d) | |
- |> Intel. VMD technology | |
- | | |
- | IIO-PCIE Express Global Options | |
- | ======================================== | |
- | PCI-E Completion Timeout Disable [No] | |
-```
-
-###### CPU1 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU1 SLOT2 PCI-E 3.0 X16 | |
- |> CPU1 SLOT4 PCI-E 3.0 X16 | |
- |> CPU1 SLOT9 PCI-E 3.0 X16 | |
-```
-
-###### CPU2 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU2 SLOT6 PCI-E 3.0 X16 | |
- |> CPU2 SLOT8 PCI-E 3.0 X16 | |
- |> CPU2 SLOT10 PCI-E 3.0 X16 | |
-```
-
-##### South Bridge
-
-```
- | |Enables Legacy USB support. |
- | USB Module Version 17 |AUTO option disables legacy |
- | |support if no USB devices |
- | USB Devices: |are connected. DISABLE |
- | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
- | |devices available only for |
- | Legacy USB Support [Enabled] |EFI applications. |
- | XHCI Hand-off [Disabled] | |
- | Port 60/64 Emulation [Enabled] | |
- | PCIe PLL SSC [Disable] | |
- | Real USB Wake Up [Enabled] | |
- | Front USB Wake Up [Enabled] | |
- | | |
- | Azalia [Auto] | |
- | Azalia PME Enable [Disabled] | |
-```
-
-#### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit |
- | |capable Devices to be |
- | PCI Devices Common Settings: |Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] |Space (Only if System |
- | SR-IOV Support [Enabled] |Supports 64 bit PCI |
- | MMIO High Base [56T] |Decoding). |
- | MMIO High Granularity Size [256G] | |
- | Maximum Read Request [Auto] | |
- | MMCFG Base [2G] | |
- | NVMe Firmware Source [Vendor Defined Fi...] | |
- | VGA Priority [Onboard] | |
- | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
- | M.2 CONNECTOR OPROM [Legacy] | |
- | Onboard LAN1 Option ROM [Legacy] | |
- | Onboard LAN2 Option ROM [Disabled] | |
- | Onboard Video Option ROM [Legacy] | |
- |> Network Stack Configuration | |
-```
-
-#### ACPI Settings
-
-```
- | ACPI Settings |Enable or Disable Non |
- | |uniform Memory Access |
- | NUMA [Enabled] |(NUMA). |
- | WHEA Support [Enabled] | |
- | High Precision Event Timer [Enabled] | |
- | ACPI Sleep State [S3 (Suspend to RAM)] | |
-```
-
-#### DMIDECODE
-
-```
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.1.1 present.
- Table at 0x000E89C0.
-
- Handle 0x0000, DMI type 0, 26 bytes
- BIOS Information
- Vendor: American Megatrends Inc.
- Version: 2.0
- Release Date: 11/29/2017
- Address: 0xF0000
- Runtime Size: 64 kB
- ROM Size: 64 MB
- Characteristics:
- PCI is supported
- BIOS is upgradeable
- BIOS shadowing is allowed
- Boot from CD is supported
- Selectable boot is supported
- BIOS ROM is socketed
- EDD is supported
- 5.25"/1.2 MB floppy services are supported (int 13h)
- 3.5"/720 kB floppy services are supported (int 13h)
- 3.5"/2.88 MB floppy services are supported (int 13h)
- Print screen service is supported (int 5h)
- Serial services are supported (int 14h)
- Printer services are supported (int 17h)
- ACPI is supported
- USB legacy is supported
- BIOS boot specification is supported
- Targeted content distribution is supported
- UEFI is supported
- BIOS Revision: 5.12
-
- Handle 0x0001, DMI type 1, 27 bytes
- System Information
- Manufacturer: Supermicro
- Product Name: SYS-7049GP-TRT
- Version: 0123456789
- Serial Number: S291427X8332242
- UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
- Wake-up Type: Power Switch
- SKU Number: To be filled by O.E.M.
- Family: To be filled by O.E.M.
-
- Handle 0x0002, DMI type 2, 15 bytes
- Base Board Information
- Manufacturer: Supermicro
- Product Name: X11DPG-QT
- Version: 1.02
- Serial Number: VM183S014930
- Asset Tag: To be filled by O.E.M.
- Features:
- Board is a hosting board
- Board is replaceable
- Location In Chassis: To be filled by O.E.M.
- Chassis Handle: 0x0003
- Type: Motherboard
- Contained Object Handles: 0
-
- Handle 0x0003, DMI type 3, 22 bytes
- Chassis Information
- Manufacturer: Supermicro
- Type: Other
- Lock: Not Present
- Version: 0123456789
- Serial Number: C7470KH06A20167
- Asset Tag: To be filled by O.E.M.
- Boot-up State: Safe
- Power Supply State: Safe
- Thermal State: Safe
- Security Status: None
- OEM Information: 0x00000000
-
- Handle 0x0050, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU1
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x004D
- L2 Cache Handle: 0x004E
- L3 Cache Handle: 0x004F
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-
-
- Handle 0x0054, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU2
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x0051
- L2 Cache Handle: 0x0052
- L3 Cache Handle: 0x0053
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-### Xeon Skx Server Firmware Inventory
-
-```
-Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
-s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s2-t12-sut1. 10.30.50.48. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s3-t21-sut1. 10.30.50.41. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s4-t21-tg1. 10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s5-t22-sut1. 10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s6-t22-tg1. 10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s7-t23-sut1. 10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s8-t23-tg1. 10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s9-t24-sut1. 10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s10-t24-tg1. 10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s11-t31-sut1. 10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s12-t31-sut2. 10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s13-t31-tg1. 10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s14-t32-sut1. 10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s15-t32-sut2. 10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s16-t32-tg1. 10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-```