diff options
author | Peter Mikus <pmikus@cisco.com> | 2022-07-07 10:00:02 +0000 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2022-08-03 08:10:02 +0000 |
commit | 82b34c726b4eb93fbb8ca48b491dd7da65cb813b (patch) | |
tree | 4a77f69dd8a212f5759ba8f2c538564a90546a7e /docs/lab/fdio-dc-inventory-vexxhost.md | |
parent | dc200e7f96297b3bccecb88b4e951b142617734b (diff) |
feat(pxe): Migrate Ubuntu Jammy I.
Signed-off-by: Peter Mikus <pmikus@cisco.com>
Change-Id: I8f79882fce6375a55d67167781fc6b4212934e06
Diffstat (limited to 'docs/lab/fdio-dc-inventory-vexxhost.md')
-rw-r--r-- | docs/lab/fdio-dc-inventory-vexxhost.md | 142 |
1 files changed, 0 insertions, 142 deletions
diff --git a/docs/lab/fdio-dc-inventory-vexxhost.md b/docs/lab/fdio-dc-inventory-vexxhost.md deleted file mode 100644 index 87a72f02cd..0000000000 --- a/docs/lab/fdio-dc-inventory-vexxhost.md +++ /dev/null @@ -1,142 +0,0 @@ -<!-- MarkdownTOC autolink="true" --> - -- [FD.io DC Vexxhost Inventory](#fdio-dc-vexxhost-inventory) - - [Missing Equipment Inventory](#missing-equipment-inventory) - - [YUL1 Inventory](#yul1-inventory) - - [Rack YUL1-8 (3016.8)](#rack-yul1-8-3016.8) - - [Rack YUL1-9 (3016.9)](#rack-yul1-9-3016.9) - - [Rack YUL1-10 (3016.10)](#rack-yul1-10-3016.10) - - [Rack YUL1-11 (3016.11)](#rack-yul1-11-3016.11) - - [Rack YUL1-12 (3016.12)](#rack-yul1-12-3016.12) - -<!-- /MarkdownTOC --> - -## FD.io DC Vexxhost Inventory - -- for each DC location, per rack .csv table with server inventory -- captured inventory data: name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4 - - name: CSIT functional server name as tracked in [CSIT testbed specification](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md), followed by "/" and the actual configured hostname, unless it is the same as CSIT name. - - oper-status: operational status (up|down|ipmi). - - testbed-id: CSIT testbed identifier. - - role: 2n/3n-xxx performance testbed, nomad-client, nomad-server. - - role exceptions: decommission, repurpose, spare. - - model: server model. - - s/n: serial number. - - mgmt-ip4: current management IPv4 address on management VLAN. - - ipmi-ip4: current IPMI IPv4 address on LOM VLAN. - - rackid: new location rack id. - - rackunit: new location rack unit id. - -### Missing Equipment Inventory - -1. Ixia PerfectStorm One Appliance - - [Specification: Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n554) - - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017) - - [mgmt-ip4 10.30.51.62 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n374) - - [ipmi-ip4 10.30.50.59 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n281) - -### YUL1 Inventory - -#### Rack YUL1-8 (3016.8) -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -mtl1-8-lb4m,up,switch,uplink,?,?,?,?,3016.8,u47,?,? -s65-t37-sut1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50098,10.30.51.75,10.30.50.75,3016.8,u42-u45 -s66-t37-sut2,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK33P50247,10.30.51.76,10.30.50.76,3016.8,u38-u41 -s67-t37-tg1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50076,10.30.51.77,10.30.50.77,3016.8,u34-u37 -s71-t212-sut1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK25P50173,10.30.51.81,10.30.50.81,3016.8,u30-u33 -s72-t212-tg1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK33P50220,10.30.51.82,10.30.50.82,3016.8,u26-u29 -s83-t213-sut1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL07P50300,10.30.51.83,10.30.50.83,3016.8,u22-u25 -s84-t213-tg1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL03P50187,10.30.51.84,10.30.50.84,3016.8,u18-u21 -s85-t214-sut1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KK33P50219,10.30.51.85,10.30.50.85,3016.8,u14-u17 -s86-t214-tg1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KL07P50312,10.30.51.86,10.30.50.86,3016.8,u10-u13 -s87-t215-sut1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL03P50171,10.30.51.87,10.30.50.87,3016.8,u6-u9 -s88-t215-tg1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL07P50301,10.30.51.88,10.30.50.88,3016.8,u2-u5 - -#### Rack YUL1-9 (3016.9) -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -mtl1-5-lb4m,up,switch,uplink,?,?,?,?,3016.9,u47,?,? -s11-t31-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20037,10.30.51.46,10.30.50.43,3016.9,u42-u45 -s12-t31-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20018,10.30.51.47,10.30.50.44,3016.9,u38-u41 -s13-t31-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20043,10.30.51.48,10.30.50.45,3016.9,u34-u37 -s14-t32-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20075,10.30.51.58,10.30.50.55,3016.9,u30-u33 -s15-t32-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20010,10.30.51.59,10.30.50.56,3016.9,u26-u29 -s16-t32-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20047,10.30.51.60,10.30.50.57,3016.9,u22-u25 -s25-t25-sut1,down,t25,2n-p1,SYS-7049GP-TRT,C7470KH06A20022,10.30.51.61,10.30.50.58,3016.9,u18-u21 -s19-t33t211-tg1,up,t33t211,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51.49,10.30.50.46,3016.9,u14-u17 -s27-t211-sut1,up,t211,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13 -s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.37,10.30.50.37,3016.9,u11-u12 -s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.36,10.30.50.36,3016.9,u9-u10 -s79-t39t310-tg1,in-transit,t39t310,tbd,SYS-740GP-TNRT,???,10.30.51.89,10.30.50.89,3016.9,u5-u8 - -#### Rack YUL1-10 (3016.10) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-10-lb4m,up,switch,uplink,?,?,?,?,3016.10,u47,?,? -s2-t12-sut1,up,t12,1n-skx,SYS-7049GP-TRT,C7470KH06A20119,10.30.51.51,10.30.50.48,3016.10,u42-u45 -s1-t11-sut1,up,t11,1n-skx,SYS-7049GP-TRT,C7470KH06A20154,10.30.51.50,10.30.50.47,3016.10,u38-u41 -s3-t21-sut1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20167,10.30.51.44,10.30.50.41,3016.10,u34-u37 -s4-t21-tg1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20158,10.30.51.45,10.30.50.42,3016.10,u30-u33 -s5-t22-sut1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.52,10.30.50.49,3016.10,u26-u29 -s6-t22-tg1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.53,10.30.50.50,3016.10,u22-u25 -s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.54,10.30.50.51,3016.10,u18-u21 -s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,10.30.51.55,10.30.50.52,3016.10,u14-u17 -s93-t39-sut1,up,t39,3n-snr,?,?,10.30.51.93,10.30.50.93,3016.10,u10-u13 -s94-t39-sut2,up,t39,3n-snr,?,?,10.30.51.94,10.30.50.94,3016.10,u6-u9 -s89-t39t310-tg1,up,t39,3n-snr,?,?,10.30.51.89,10.30.50.89,3016.10,u2-u5 - -#### Rack YUL1-11 (3016.11) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-11-lb6m,up,switch,arm-uplink,?,?,?,?,3016.11,u48 -yul1-11-lf-tor-switch,up,switch,uplink,?,?,?,?,3016.11,u47 -mtl1-6-7050QX-32,up,switch,uplink,?,?,?,?,3016.11,u46 -fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,10.30.51.38,10.30.50.38,3016.11,u45 -s53-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.39,10.30.50.39,3016.11,u44 -s54-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.40,10.30.50.40,3016.11,u43 -s56-t14-sut1,up,t14,1n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u41-u42 -s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,10.30.51.28,10.30.50.28,3016.11,u39-u40 -s40-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0HZ,10.30.51.30,10.30.50.30,3016.11,u37-u38 -s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,10.30.51.29,10.30.50.29,3016.11,u35-u36 -s78-t38-sut1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50450,10.30.51.78,10.30.50.78,3016.11,u31-u34 -s79-t38-sut2,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL07P50297,10.30.51.79,10.30.50.79,3016.11,u27-u30 -s80-t38-tg1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50454,10.30.51.80,10.30.50.80,3016.11,u23-u26 -s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.65,10.30.50.65,3016.11,u21-u22 -s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.66,10.30.50.66,3016.11,u21-u22 -s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.67,10.30.50.67,3016.11,u21-u22 -s50-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.68,10.30.50.68,3016.11,u21-u22 -s42-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.22,10.30.50.22,3016.11,u19-u20 -s43-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.24,10.30.50.24,3016.11,u17-u18 -s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.25,10.30.50.25,3016.11,u15-u16 -s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.26,10.30.50.26,3016.11,u13-u14 -s55-t13-sut1,up,t13,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12 -s62-t34-sut1,up,t34,3n-alt,WIWYNN,04000059N0SC,10.30.51.72,10.30.50.72,3016.11,u9-u10 -s63-t34-sut2,up,t34,3n-alt,WIWYNN,0390003EN0SC,10.30.51.73,10.30.50.73,3016.11,u7-u8 -s64-t34-tg1,up,t34,3n-alt,SYS-740GP-TNRT,C7470KK40P50249,10.30.51.74,10.30.50.74,3016.11,u3-u6 - -#### Rack YUL1-12 (3016.12) - -name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit -yul1-12-lb4m,up,switch,uplink,?,?,?,?,3016.12,u47 -s31-t35-sut2/dnv3,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040898,10.32.8.13,10.30.55.13,3016.12,u45 -s30-t35-sut1/dnv2,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040866,10.32.8.12,10.30.55.12,3016.12,u44 -s29-t26-sut1/dnv1,up,t26,2n-dnv,SYS-E300-9A,CE300AG39040897,10.32.8.11,10.30.55.11,3016.12,u43 -s28-t26t35-tg1,up,t26t35,2n/3n-dnv,SYS-7049GP-TRT,C7470KH06A20137,10.32.8.10,10.30.55.10,3016.12,u39-u42 -s58-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0016,10.30.51.91,10.30.50.91,3016.12,u36 -s59-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0004,10.30.51.92,10.30.50.92,3016.12,u35 -s46-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0256,10.32.8.14,10.30.55.14,3016.12,u34 -s47-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0241,10.32.8.15,10.30.55.15,3016.12,u33 -s48-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0540,10.32.8.16,10.30.55.16,3016.12,u32 -s61-t210-tg1,up,t210,2n-zn2,AS-1014S-WTRT,C8150LI50NS2689,10.32.8.25,10.30.55.25,3016.12,u31 -s60-t210-sut1,up,t210,2n-zn2,AS-1114S-WTRT,N/A,10.32.8.24,10.30.55.24,3016.12,u30 -s57-nomad,up,nomad-cluster1,nomad-server,SYS-7049GP-TRT,C7470KH37A30505,10.32.8.17,10.30.55.17,3016.12,u26-u29 -s33-t27-sut1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30567,10.32.8.18,10.30.55.18,3016.12,u22-u25 -s34-t27-tg1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30565,10.32.8.19,10.30.55.19,3016.12,u18-u21 -s35-t28-sut1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30509,10.32.8.20,10.30.55.20,3016.12,u14-u17 -s36-t28-tg1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30511,10.32.8.21,10.30.55.21,3016.12,u10-u13 -s37-t29-sut1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30566,10.32.8.22,10.30.55.22,3016.12,u6-u9 -s38-t29-tg1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30506,10.32.8.23,10.30.55.23,3016.12,u2-u5 - -Notes: - -- UCSC-C240-M4 EoL: - [End-of-Life Announcement for the Cisco Unified Computing System C-Series](https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-servers/eos-eol-notice-c51-741235.html)
\ No newline at end of file |