aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
authorpmikus <peter.mikus@protonmail.ch>2023-03-09 13:32:33 +0000
committerPeter Mikus <peter.mikus@protonmail.ch>2023-03-15 10:06:55 +0000
commitb928e56347c682fdb9762ccbe2f368329d4037e4 (patch)
tree9c0f6a02efc1704821229b8e18a23468fdf8674a /docs/lab/testbed_specifications.md
parentddcdf45806d0efa9e89dd4446b4c7da39cfb27a8 (diff)
feat(docs): Hugo
Signed-off-by: pmikus <peter.mikus@protonmail.ch> Change-Id: Id8b43ef1f31f39b19a0629c52581514fda278f3b
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md1879
1 files changed, 0 insertions, 1879 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
deleted file mode 100644
index fc59465569..0000000000
--- a/docs/lab/testbed_specifications.md
+++ /dev/null
@@ -1,1879 +0,0 @@
-# FD.io CSIT Testbed Specifications
-
-1. [Purpose](#purpose)
-1. [Testbeds Overview](#testbeds-overview)
- 1. [Summary List](#summary-list)
- 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
- 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
- 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
- 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
- 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
- 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
- 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
- 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
- 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
- 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
- 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
- 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
- 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr)
- 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr)
-1. [Server Management](#server-management)
- 1. [Addressing](#addressing)
-1. [Server Specifications](#server-specifications)
- 1. [Server Types](#server-types)
- 1. [Naming Convention](#naming-convention)
-1. [Testbeds Configuration](#testbeds-configuration)
- 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
- 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
- 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
- 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
- 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
- 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
- 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
- 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
- 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
- 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
- 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
- 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
- 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod)
- 1. [Per Testbed Wiring](#per-testbed-wiring)
- 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
- 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
- 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
- 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
- 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
- 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
- 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
- 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
- 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
- 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
- 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
- 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod)
-
-## Purpose
-
-This note includes specification of the physical testbed infrastructure
-hosted by LFN FD.io CSIT project.
-
-## Testbeds Overview
-
-### Summary List
-
-```
- #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
- 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
- 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
- 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
- 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
- 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
- 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
- 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
- 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
- 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
-10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
-11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
-12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
-13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
-13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
- Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
-```
-
-### 1-Node-Skylake Xeon Intel (1n-skx)
-
-Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-Cascadelake Xeon Intel (1n-clx)
-
-Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
-NIC ports connected back-to-back ([Server Types](#server-types)).
-
-Used for FD.io VPP_Device functional driver tests.
-
-### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
-
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
-circular topology ([Server Types](#server-types)).
-Used for FD.io TCP/IP and HTTP performance tests.
-
-### 2-Node-Cascadelake Xeon Intel (2n-clx)
-
-Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
-one TG (Server-Type-C3) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Zen2 EPYC AMD (2n-zn2)
-
-Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
-one TG (Server-Type-D2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
-
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
-one TG (Server-Type-E31) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Icelake Xeon Intel (2n-icx)
-
-Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
-one TG (Server-Type-F2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Rangeley Atom Testbeds
-
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-TaiShan Arm Huawei (3n-tsh)
-
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
-TG (Server-Type-E31) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Altra Arm Ampere (3n-alt)
-
-Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
-TG (Server-Type-F4) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Icelake Xeon Intel (3n-icx)
-
-Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
-TG (Server-Type-F3) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-SnowRidge Atom Intel (3n-snr)
-
-Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
-TG (Server-Type-F4) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
-
-One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
-one TG (Server-Type-H2) connected in a 2-node physical topology
-with NUMA (socket) daisy chaining. For more detail see
-[Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
-Used for FD.io performance tests in a full system SUT setup with all PCIe
-Gen5 x16 lane slots populated with 2p200GbE NICs.
-
-### 2-Node-SapphireRapids Xeon Intel (2n-spr)
-
-Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
-one TG (Server-Type-H6) connected in a 2-node circular topology. For more
-detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
-Used for FD.io performance tests.
-
-## Server Management
-
-### Addressing
-
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
-Management port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
- - Subnet: 10.30.50.0/24
- - Gateway: 10.30.50.1
- - Broadcast: 10.30.50.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-2. Management Vlan:
- - Subnet: 10.30.51.0/24
- - Gateway: 10.30.51.1
- - Broadcast: 10.30.51.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-```
-
-To access these hosts, VPN connection is required.
-
-## Server Specifications
-
-### Server Types
-
-FD.io CSIT lab contains following server types:
-```
-1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: empty.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- - Quantity: 1.
- - Physical connectivity:
- - Host management interface: 10/100/1000-BaseT.
- - 8-port 10GE SFP+ integrated NIC.
- - Main HW configuration:
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
- - Interface configuration:
- - Port-1: 10GE SFP+.
- - Port-2: 10GE SFP+.
- - Port-3: 10GE SFP+.
- - Port-4: 10GE SFP+.
-4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- - Quantity: 3
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Gold 6252N 2.3 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
- - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- - PCIe Slot10 d8:00.xx: empty.
-8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - no NIC ports, standalone setup.
- - Main HW configuration:
- - Chassis: SuperMicro 1029P-WTRT.
- - Motherboard: SuperMicro X11DDW-NT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 4* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0:
- - no cards.
- - Numa1:
- - no cards.
-9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro AS-1114S-WTRT
- - Processors: 1* AMD EPYC 7532 2.4 GHz.
- - RAM Memory: 8* 32GB DDR4-2933.
- - Disks: 1* 1TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro AS-1114S-WTRT
- - Processors: 1* AMD EPYC 7532 2.4 GHz.
- - RAM Memory: 8* 32GB DDR4-2933.
- - Disks: 1* 1TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
-11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: GIGABYTE Rack Mount
- - Motherboard: MT91-FS4-00
- - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
- - RAM Memory: 16 * 16GB DIMM
- - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - NICs configuration:
- - Numa0:
- - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
- - Numa1:
- - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motherboard: MT91-FS1
- - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - no cards
- - Numa1:
- - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-node topologies.
- - Main HW configuration:
- - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
- - Motherboard: Mt.Jade Motherboard
- - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
- - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
- - RAM Memory: 16* 8GB DDR4-3200MT/s
- - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
- - NICs configuration:
- - Numa0:
- - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
- - Numa1:
- - no cards.
-15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - Main HW configuration:
- - Chassis: Gigabyte R152-P30-00 1U
- - Motherboard: MP32-AR1-00
- - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
- - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
- - RAM Memory: 12* 16GB DDR4-3200MT/s
- - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
- - Quantity: 8.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node or 3-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-740GP-TNRT.
- - Motherboard: Super X12DPG-QT6.
- - Processors: 2* Intel Platinum 8358 2.6 GHz.
- - RAM Memory: 16* 16GB DDR4-3200.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- - Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-740GP-TNRT.
- - Motherboard: Super X12DPG-QT6.
- - Processors: 2* Intel Platinum 8358 2.6 GHz.
- - RAM Memory: 16* 16GB DDR4-3200.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- - Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-740GP-TNRT.
- - Motherboard: Super X12DPG-QT6.
- - Processors: 2* Intel Platinum 8358 2.6 GHz.
- - RAM Memory: 16* 16GB DDR4-3200.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
- - Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and/or 3-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-740GP-TNRT.
- - Motherboard: Super X12DPG-QT6.
- - Processors: 2* Intel Platinum 8358 2.6 GHz.
- - RAM Memory: 16* 16GB DDR4-3200.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot10 d8:00.xx: empty.
-21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-node testbed topology.
- - Main HW configuration:
- - Chassis: Intel JACOBSVILLE SDP.
- - Motherboard: Intel JACOBSVILLE E63448-400.
- - Processors: 1* Intel Atom P5362B 2.2 GHz.
- - RAM Memory: 2* 16GB DDR4-2933.
- - Disks: ?* ? SATA SSD.
- - NICs configuration:
- - Numa0: (x16, PCIe3.0 lane)
- - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-numa-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-numa-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot11 d8:00.xx: empty.
-24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-numa-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot10 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot11 d8:00.xx: empty.
-25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 3-numa-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot10 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: empty.
- - PCIe Slot9 af:00.xx: empty.
- - PCIe Slot11 d8:00.xx: empty.
-26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: empty.
- - PCIe Slot9 af:00.xx: empty.
- - PCIe Slot11 d8:00.xx: empty.
-27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-741GE-TNRT.
- - Motherboard: Super X13DEG-QT-P.
- - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
- - RAM Memory: 16* 32GB DDR5-4800.
- - Disks: 2* 960GB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
- - Numa1: (x16, x16, x16 PCIe5.0 lanes)
- - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot11 d8:00.xx: empty.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
- - traffic-generator: tN-tgW.
- - system-under-testX: tN-sutX.
-- portnames:
- - tN-tgW-cY/pZ.
- - tN-sutX-cY/pZ.
-- where:
- - N - testbed number.
- - tgW - server acts as traffic-generator with W index.
- - sutX - server acts as system-under-test with X index.
- - Y - PCIe slot number denoting a NIC card number within the host.
- - Z - port number on the NIC card.
-```
-
-## Testbeds Configuration
-
-### Per Testbed Server Allocation and Naming
-
-#### 1-Node-Skylake Servers (1n-skx) PROD
-
-```
-- SUT [Server-Type-B6]:
- - testbedname: testbed11.
- - hostname: s1-t11-sut1.
- - IPMI IP: 10.30.50.47
- - Host IP: 10.30.51.50
- - portnames:
- - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B6]:
- - testbedname: testbed12.
- - hostname: s2-t12-sut1.
- - IPMI IP: 10.30.50.48
- - Host IP: 10.30.51.51
- - portnames:
- - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
-
-```
-- SUT [Server-Type-E11]:
- - testbedname: testbed13
- - hostname: s55-t13-sut1
- - IPMI IP: 10.30.50.70
- - Host IP: 10.30.51.70
- - portnames:
- - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-E11]:
- - testbedname: testbed14
- - hostname: s56-t14-sut1
- - IPMI IP: 10.30.50.71
- - Host IP: 10.30.51.71
- - portnames:
- - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-```
-
-#### 1-Node-Cascadelake Servers (1n-clx) PROD
-
-```
-- SUT [Server-Type-C1]:
- - testbedname: testbed11.
- - hostname: s32-t14-sut1.
- - IPMI IP: 10.30.55.17
- - Host IP: 10.32.8.17
- - portnames:
- - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
-
-```
-- SUT [Server-Type-B8]:
- - testbedname: testbed25.
- - hostname: s25-t25-sut1.
- - IPMI IP: 10.30.50.58
- - Host IP: 10.30.51.61
- - portnames:
- - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- TG [Server-Type-B7]:
- - testbedname: testbed25.
- - hostname: s26-t25-tg1.
- - IPMI IP: 10.30.50.59
- - Host IP: 10.30.51.62
- - portnames:
- - s26-t25-tg1-p1 - 10GE-port1.
- - s26-t25-tg1-p2 - 10GE-port2.
- - s26-t25-tg1-p3 - 10GE-port3.
- - s26-t25-tg1-p4 - 10GE-port4.
-```
-
-#### 2-Node-Cascadelake Servers (2n-clx) PROD
-
-```
-- SUT [Server-Type-C2]:
- - testbedname: testbed27.
- - hostname: s33-t27-sut1.
- - IPMI IP: 10.30.55.18
- - Host IP: 10.32.8.18
- - portnames:
- - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed27.
- - hostname: s34-t27-tg1.
- - IPMI IP: 10.30.55.19
- - Host IP: 10.32.8.19
- - portnames:
- - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed28.
- - hostname: s35-t28-sut1.
- - IPMI IP: 10.30.55.20
- - Host IP: 10.32.8.20
- - portnames:
- - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed28.
- - hostname: s36-t28-tg1.
- - IPMI IP: 10.30.55.21
- - Host IP: 10.32.8.21
- - portnames:
- - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed29.
- - hostname: s37-t29-sut1.
- - IPMI IP: 10.30.55.22
- - Host IP: 10.32.8.22
- - portnames:
- - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed29.
- - hostname: s38-t29-tg1.
- - IPMI IP: 10.30.55.23
- - Host IP: 10.32.8.23
- - portnames:
- - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 2-Node-Zen2 Servers (2n-zn2) PROD
-
-```
-- SUT [Server-Type-D1]:
- - testbedname: testbed210.
- - hostname: s60-t210-sut1.
- - IPMI IP: 10.30.55.24
- - Host IP: 10.32.8.24
- - portnames:
- - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
- - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
- - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
- - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
- - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-D2]:
- - testbedname: testbed210.
- - hostname: s61-t210-tg1.
- - IPMI IP: 10.30.55.25
- - Host IP: 10.32.8.25
- - portnames:
- - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
-
-Note: Server19 (TG) is shared between testbed33 & testbed211
-
-```
-- SUT [Server-Type-E22]:
- - testbedname: testbed211.
- - hostname: s27-t211-sut1.
- - IPMI IP: 10.30.50.69
- - Host IP: 10.30.51.69
- - portnames:
- - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-- TG [Server-Type-E31]:
- - testbedname: testbed33 and testbed211.
- - hostname: s19-t33t211-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-Icelake Servers (2n-icx) PROD
-
-```
-- SUT [Server-Type-F1]:
- - testbedname: testbed212.
- - hostname: s71-t212-sut1.
- - IPMI IP: 10.30.50.81
- - Host IP: 10.30.51.81
- - portnames:
- - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
- - testbedname: testbed212.
- - hostname: s72-t212-tg1.
- - IPMI IP: 10.30.50.82
- - Host IP: 10.30.51.82
- - portnames:
- - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
- - testbedname: testbed213.
- - hostname: s83-t213-sut1.
- - IPMI IP: 10.30.50.83
- - Host IP: 10.30.51.83
- - portnames:
- - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
- - testbedname: testbed213.
- - hostname: s84-t213-tg1.
- - IPMI IP: 10.30.50.84
- - Host IP: 10.30.51.84
- - portnames:
- - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
- - testbedname: testbed214.
- - hostname: s85-t214-sut1.
- - IPMI IP: 10.30.50.85
- - Host IP: 10.30.51.85
- - portnames:
- - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
- - testbedname: testbed214.
- - hostname: s86-t214-tg1.
- - IPMI IP: 10.30.50.86
- - Host IP: 10.30.51.86
- - portnames:
- - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
- - testbedname: testbed215.
- - hostname: s87-t215-sut1.
- - IPMI IP: 10.30.50.87
- - Host IP: 10.30.51.87
- - portnames:
- - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
- - testbedname: testbed215.
- - hostname: s88-t215-tg1.
- - IPMI IP: 10.30.50.88
- - Host IP: 10.30.51.88
- - portnames:
- - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-Rangeley Servers (3n-rng) VERIFY
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- ServerB22 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
- - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
- - Host IP: 10.30.51.9
- - portnames:
- - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB23 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
- - Host IP: 10.30.51.10
- - portnames:
- - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB24 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
- - Host IP: 10.30.51.11
- - portnames:
- - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-```
-
-#### 3-Node-Taishan Servers (3n-tsh) PROD
-
-Note: Server19 (TG) is shared between testbed33 & testbed211
-
-```
-- SUT [Server-Type-E21]:
- - testbedname: testbed33.
- - hostname: s17-t33-sut1.
- - IPMI IP: 10.30.50.36
- - Host IP: 10.30.51.36
- - portnames:
- - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
- - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-E21]:
- - testbedname: testbed33.
- - hostname: s18-t33-sut2.
- - IPMI IP: 10.30.50.37
- - Host IP: 10.30.51.37
- - portnames:
- - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
- - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-E31]:
- - testbedname: testbed33 and testbed211.
- - hostname: s19-t33t211-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 3-Node-Altra Servers (3n-alt) PROD
-
-```
-- SUT [Server-Type-E23]:
- - testbedname: testbed34.
- - hostname: s62-t34-sut1.
- - IPMI IP: 10.30.50.72
- - Host IP: 10.30.51.72
- - portnames:
- - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- SUT [Server-Type-E23]:
- - testbedname: testbed34.
- - hostname: s63-t34-sut2.
- - IPMI IP: 10.30.50.73
- - Host IP: 10.30.51.73
- - portnames:
- - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- TG [Server-Type-F4]:
- - testbedname: testbed34.
- - hostname: s64-t34-tg1.
- - IPMI IP: 10.30.50.74
- - Host IP: 10.30.51.74
- - portnames:
- - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-Icelake Servers (3n-icx) PROD
-
-```
-- ServerF1 [Server-Type-F1]:
- - testbedname: testbed37.
- - hostname: s65-t37-sut1.
- - IPMI IP: 10.30.50.75
- - Host IP: 10.30.51.75
- - portnames:
- - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
- - testbedname: testbed37.
- - hostname: s66-t37-sut2.
- - IPMI IP: 10.30.50.76
- - Host IP: 10.30.51.76
- - portnames:
- - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF3 [Server-Type-F3]:
- - testbedname: testbed37.
- - hostname: s67-t37-tg1.
- - IPMI IP: 10.30.50.77
- - Host IP: 10.30.51.77
- - portnames:
- - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
- - testbedname: testbed38.
- - hostname: s78-t38-sut1.
- - IPMI IP: 10.30.50.78
- - Host IP: 10.30.51.78
- - portnames:
- - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
- - testbedname: testbed38.
- - hostname: s79-t38-sut2.
- - IPMI IP: 10.30.50.79
- - Host IP: 10.30.51.79
- - portnames:
- - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF3 [Server-Type-F3]:
- - testbedname: testbed38.
- - hostname: s80-t38-tg1.
- - IPMI IP: 10.30.50.80
- - Host IP: 10.30.51.80
- - portnames:
- - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-SnowRidge Servers (3n-snr) PROD
-
-```
-- ServerG1 [Server-Type-G1]:
- - testbedname: testbed39.
- - hostname: s93-t39-sut1.
- - IPMI IP: 10.30.50.93
- - Host IP: 10.30.51.93
- - portnames:
- - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
-- ServerG1 [Server-Type-G1]:
- - testbedname: testbed39.
- - hostname: s94-t39-sut2.
- - IPMI IP: 10.30.50.94
- - Host IP: 10.30.51.94
- - portnames:
- - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- ServerF4 [Server-Type-F4]:
- - testbedname: testbed39.
- - hostname: s89-t39t310-tg1.
- - IPMI IP: 10.30.50.89
- - Host IP: 10.30.51.89
- - portnames:
- - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-```
-
-#### 2-Node-SapphireRapids Servers (2n-spr) PROD
-
-```
-- SUT [Server-Type-H1]:
- - testbedname: testbed21.
- - hostname: s52-t21-sut1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.52
- - portnames:
- - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
-- TG [Server-Type-H2]:
- - testbedname: testbed21.
- - hostname: s53-t21-tg1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.53
- - portnames:
- - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
-- SUT [Server-Type-H3]:
- - testbedname: testbed22.
- - hostname: s54-t22-sut1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.54
- - portnames:
- - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- TG [Server-Type-H4]:
- - testbedname: testbed22.
- - hostname: s55-t22-tg1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.55
- - portnames:
- - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- SUT [Server-Type-H5]:
- - testbedname: testbed23.
- - hostname: s56-t23-sut1.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.56
- - portnames:
- - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- TG [Server-Type-H6]:
- - testbedname: testbed23.
- - hostname: s57-t23-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.57
- - portnames:
- - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-H5]:
- - testbedname: testbed24.
- - hostname: s58-t24-sut1.
- - IPMI IP: 10.30.50.58
- - Host IP: 10.30.51.58
- - portnames:
- - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- TG [Server-Type-H6]:
- - testbedname: testbed24.
- - hostname: s59-t24-tg1.
- - IPMI IP: 10.30.50.59
- - Host IP: 10.30.51.59
- - portnames:
- - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
- - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-### Per Testbed Wiring
-
-#### 1-Node-Skylake Wiring (1n-skx) PROD
-
-```
-- testbed11:
- - ring1 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
- - ring5 100GE-ports e810-2p100GE:
- - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
- - ring6 100GE-ports e810-2p100GE:
- - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
-- testbed12:
- - ring1 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
- - ring5 100GE-ports e810-2p100GE:
- - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
- - ring6 100GE-ports e810-2p100GE:
- - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
-```
-
-#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
-
-```
-- testbed13:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
- - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
-
-- testbed14:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
- - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
-```
-
-#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
-
-```
-- testbed25:
- - link1 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p1 to t25-sut1-c2/p1.
- - link2 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p2 to t25-sut1-c2/p2.
- - link3 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p3 to t25-sut1-c2/p3.
- - link4 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-#### 2-Node-Cascadelake Wiring (2n-clx) PROD
-
-```
-- testbed27:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
- - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
- - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
- - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
- - ring6 100GE-ports e810-2p100GE on TG:
- - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
- - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
-- testbed28:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
- - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
- - ring6 100GE-ports e810-2p100GE on TG:
- - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
- - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
-- testbed29:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
- - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
-```
-
-#### 2-Node-Zen2 Wiring (2n-zn2) PROD
-
-```
-- testbed210:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
- - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
- - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
- - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
- - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
-```
-
-#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
-
-```
-- testbed211:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
- - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
-```
-
-#### 2-Node-Icelake Wiring (2n-icx) PROD
-
-```
-- testbed212:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
- - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
- - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
- - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
- - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
- - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
- - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
- - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
-- testbed213:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
- - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
- - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
- - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
- - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
- - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
- - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
- - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
-- testbed214:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
- - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
- - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
- - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
- - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
- - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
- - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
- - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
-- testbed215:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
- - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
- - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
- - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
- - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
- - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
- - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
- - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
-```
-
-#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
-
-```
-To be completed.
-```
-
-#### 3-Node-Taishan Wiring (3n-tsh) PROD
-
-```
-- testbed33:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
- - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
- - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
- - ring2 25GE-ports cx4-2p25GE on SUTs:
- - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
- - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
- - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
-```
-
-#### 3-Node-Altra Wiring (3n-alt) PROD
-
-```
-- testbed34:
- - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
- - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
- - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
- - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
-```
-
-#### 3-Node-Icelake Wiring (3n-icx) PROD
-
-```
-- testbed37:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
- - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
- - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
- - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
- - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
- - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
- - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
- - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
- - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
- - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
- - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
- - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
- - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
-- testbed38:
- - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
- - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
- - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
- - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
- - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
- - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
- - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
- - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
- - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
- - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
- - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
- - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
- - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
- - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
- - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
-```
-
-#### 3-Node-SnowRidge Wiring (3n-snr) PROD
-
-```
-- testbed39:
- - ring1 25GE-ports e810-XXVDA4-4p25GE:
- - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
- - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
- - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
- - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
- - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
- - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
-```
-
-#### 2-Node-SapphireRapids Wiring (2n-spr) PROD
-
-```
-- testbed21:
- - ring1 200GE-ports ConnectX7-2p200GE:
- - s52-t21-tg1-c2/p1 to s53-t21-sut1-c2/p1
- - s52-t21-tg1-c7/p1 to s53-t21-sut1-c7/p1
- - s53-t21-sut1-c4/p2 to s53-t21-sut1-c9/p2
- - ring2 200GE-ports ConnectX7-2p200GE:
- - s52-t21-tg1-c2/p2 to s53-t21-sut1-c2/p2
- - s52-t21-tg1-c7/p2 to s53-t21-sut1-c7/p2
- - s53-t21-sut1-c10/p1 to s53-t21-sut1-c11/p1
- - ring3 200GE-ports ConnectX7-2p200GE:
- - s52-t21-tg1-c4/p1 to s53-t21-sut1-c4/p1
- - s52-t21-tg1-c9/p1 to s53-t21-sut1-c9/p1
- - s53-t21-sut1-c10/p2 to s53-t21-sut1-c11/p2
-- testbed22:
- - ring1 100GE-ports e810-2CQDA2-2p100GE:
- - s54-t22-tg1-c2/p1 to s55-t22-sut1-c2/p1
- - s54-t22-tg1-c2/p2 to s55-t22-sut1-c7/p1
- - s54-t22-sut1-c2/p2 to s55-t22-sut1-c7/p2
- - ring2 25GE-ports e810-XXVDA4-4p25GE:
- - s54-t22-tg1-c4/p1 to s55-t22-sut1-c4/p1
- - s54-t22-tg1-c4/p2 to s55-t22-sut1-c9/p1
- - s54-t22-sut1-c4/p2 to s55-t22-sut1-c9/p2
-- testbed23:
- - ring1 200GE-ports ConnectX7-2p200GE:
- - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
- - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
- - ring2 100GE-ports e810-2CQDA2-2p100GE:
- - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
- - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
- - ring3 25GE-ports e810-XXVDA4-2p25GE:
- - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
- - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
- - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
- - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
- - ring4 200GE-ports ConnectX7-2p200GE:
- - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
- - ring5 100GE-ports e810-2CQDA2-2p100GE:
- - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
-- testbed24:
- - ring1 200GE-ports ConnectX7-2p200GE:
- - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
- - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
- - ring2 100GE-ports e810-2CQDA2-2p100GE:
- - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
- - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
- - ring3 25GE-ports e810-XXVDA4-2p25GE:
- - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
- - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
- - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
- - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
- - ring4 200GE-ports ConnectX7-2p200GE:
- - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
- - ring5 100GE-ports e810-2CQDA2-2p100GE:
- - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
-``` \ No newline at end of file