aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
authorjuraj.linkes <juraj.linkes@pantheon.tech>2019-03-07 14:03:36 +0100
committerVratko Polak <vrpolak@cisco.com>2019-04-05 13:58:53 +0000
commit6e96fee163eb9622bf39ed48743db86f7bcf743a (patch)
tree89266ca35da7258c80d8c410e09b5ab5112fe7c1 /docs/lab/testbed_specifications.md
parent90236e8fa69f5a226edd75a7c67f49e6d4383aaf (diff)
Fixes for Taishan testbed
* rename NICs in Taishan testbed to Intel-X520-DA2 * fix testbed NIC selection * remove unnecessary 82599es tests * blacklist unsupported tests on Taishan testbed * lowercase previously created bash local variables Change-Id: I3b7f59e2edc00929fab2f5a0fce483f236f83075 Signed-off-by: juraj.linkes <juraj.linkes@pantheon.tech>
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md12
1 files changed, 6 insertions, 6 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 69156d76d5..5a8b4b1137 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -406,7 +406,7 @@ FD.io CSIT lab contains following server types:
- Disks: 1* 4TB SATA HDD
- NICs configuration:
- PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
+ - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
@@ -1036,8 +1036,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- IPMI IP: 10.30.50.36
- Host IP: 10.30.51.36
- portnames:
- - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
- - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
+ - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
+ - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
- ServerB18 [Type-B3]:
@@ -1046,8 +1046,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- IPMI IP: 10.30.50.37
- Host IP: 10.30.51.37
- portnames:
- - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
- - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
+ - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
+ - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
- ServerB19 [Type-B2]:
@@ -1347,7 +1347,7 @@ To be completed.
```
- testbed33:
- - ring1 10GE-ports 82599-2p10GE on SUTs:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
- t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
- t33-sut1-c6/p1 - t33-sut2-c6/p2.
- t33-sut2-c6/p1 - t33t34-tg1-c2/p1.