aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab
diff options
context:
space:
mode:
authorpmikus <peter.mikus@protonmail.ch>2023-02-23 10:29:12 +0000
committerpmikus <peter.mikus@protonmail.ch>2023-02-23 10:29:12 +0000
commit5e7c4ced1ac46f93c918d070b19ad330294ad269 (patch)
treec6de1d8b7e3f52d6862f038be9513f873211e99e /docs/lab
parent8465c1bbd377b3d7568d70f33ec6d5c0ec177168 (diff)
feat(docs): Add SPR wiring
Signed-off-by: pmikus <peter.mikus@protonmail.ch> Change-Id: I6dd06e66ecf790130d7ed9da792068d239ea02db
Diffstat (limited to 'docs/lab')
-rw-r--r--docs/lab/testbed_specifications.md91
1 files changed, 82 insertions, 9 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 1c2d912979..cade63a6f5 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -219,7 +219,7 @@ To access these hosts, VPN connection is required.
FD.io CSIT lab contains following server types:
```
1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- - Quantity: ---
+ - Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- Main HW configuration:
@@ -1408,8 +1408,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- TG [Server-Type-H2]:
- testbedname: testbed21.
- hostname: s53-t21-tg1.
- - IPMI IP: 10.30.51.53
- - Host IP: 10.30.50.53
+ - IPMI IP: 10.30.50.53
+ - Host IP: 10.30.51.53
- portnames:
- s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
@@ -1442,8 +1442,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- TG [Server-Type-H4]:
- testbedname: testbed22.
- hostname: s55-t22-tg1.
- - IPMI IP: 10.30.51.55
- - Host IP: 10.30.50.55
+ - IPMI IP: 10.30.50.55
+ - Host IP: 10.30.51.55
- portnames:
- s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
@@ -1468,8 +1468,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- TG [Server-Type-H6]:
- testbedname: testbed23.
- hostname: s57-t23-tg1.
- - IPMI IP: 10.30.51.57
- - Host IP: 10.30.50.57
+ - IPMI IP: 10.30.50.57
+ - Host IP: 10.30.51.57
- portnames:
- s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
- s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
@@ -1483,6 +1483,38 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
- s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-H5]:
+ - testbedname: testbed24.
+ - hostname: s58-t24-sut1.
+ - IPMI IP: 10.30.50.58
+ - Host IP: 10.30.51.58
+ - portnames:
+ - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H6]:
+ - testbedname: testbed24.
+ - hostname: s59-t24-tg1.
+ - IPMI IP: 10.30.50.59
+ - Host IP: 10.30.51.59
+ - portnames:
+ - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
### Per Testbed Wiring
@@ -1778,7 +1810,7 @@ To be completed.
```
- testbed39:
- - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+ - ring1 25GE-ports e810-XXVDA4-4p25GE:
- s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
- s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
- s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
@@ -1790,5 +1822,46 @@ To be completed.
#### 2-Node-SapphireRapids Wiring (2n-spr) PROD
```
-TBD
+- testbed21:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - ??
+ - ??
+ - ??
+- testbed22:
+ - ring1 100GE-ports e810-2CQDA2-2p100GE:
+ - s53-t21-tg1-c2/p1 to s54-t22-sut1-c2/p2.
+ - s54-t22-sut1-c2/p1 to s54-t22-sut1-c7/p2.
+ - s54-t22-sut1-c7/p1 to s55-t22-tg1-c2/p2.
+- testbed23:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
+ - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
+ - ring2 100GE-ports e810-2CQDA2-2p100GE:
+ - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
+ - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
+ - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
+ - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
+ - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
+ - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
+ - ring4 200GE-ports ConnectX7-2p200GE:
+ - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
+ - ring5 100GE-ports e810-2CQDA2-2p100GE:
+ - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
+- testbed24:
+ - ring1 200GE-ports ConnectX7-2p200GE:
+ - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
+ - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
+ - ring2 100GE-ports e810-2CQDA2-2p100GE:
+ - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
+ - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
+ - ring3 25GE-ports e810-XXVDA4-2p25GE:
+ - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
+ - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
+ - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
+ - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
+ - ring4 200GE-ports ConnectX7-2p200GE:
+ - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
+ - ring5 100GE-ports e810-2CQDA2-2p100GE:
+ - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
``` \ No newline at end of file