diff options
author | Maciek Konstantynowicz <mkonstan@cisco.com> | 2021-07-08 15:47:53 +0100 |
---|---|---|
committer | Tibor Frank <tifrank@cisco.com> | 2021-07-13 04:40:33 +0000 |
commit | f85930d7b1e3cda191a2e60cbc4e64d93c5fd139 (patch) | |
tree | 228b4095e38f7622cfd79ea14c9c0771c1956c19 /docs/report/introduction/physical_testbeds.rst | |
parent | 52f109b0e14b5f192e2b7f0573e6cebb601d0651 (diff) |
report: add 2n-icx and 3n-icx testbed documentation
Add:
- Physical testbeds description in Introduction.
- Add physical topology diagrams.
- VPP pre-release 21.06 version used in Intel labs for CSIT tests.
Change-Id: I3c17402de8c657f66ea840c9d8692212cbf0501a
Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/report/introduction/physical_testbeds.rst')
-rw-r--r-- | docs/report/introduction/physical_testbeds.rst | 82 |
1 files changed, 78 insertions, 4 deletions
diff --git a/docs/report/introduction/physical_testbeds.rst b/docs/report/introduction/physical_testbeds.rst index 7755bdddeb..fbc16eeaa3 100644 --- a/docs/report/introduction/physical_testbeds.rst +++ b/docs/report/introduction/physical_testbeds.rst @@ -26,12 +26,18 @@ Two physical server topology types are used: Current FD.io production testbeds are built with SUT servers based on the following processor architectures: -- Intel Xeon: Skylake Platinum 8180, Cascade Lake Platinum 8280, - Cascade Lake 6252N. +- Intel Xeon: Skylake Platinum 8180, Cascadelake 6252N, (Icelake 8358 + installation in progress). - Intel Atom: Denverton C3858. - Arm: TaiShan 2280, hip07-d05. - AMD EPYC: Zen2 7532. +CSIT-2106 report data for Intel Xeon Icelake testbeds comes from +testbeds in Intel labs set up per CSIT specification and running CSIT +code. Physical setup used is specified in 2n-icx and 3n-icx sections +below. For details about tested VPP and CSIT versions +see :ref:`vpp_performance_tests_release_notes`. + Server SUT performance depends on server and processor type, hence results for testbeds based on different servers must be reported separately, and compared if appropriate. @@ -83,7 +89,7 @@ NIC models: All AMD EPYC Zen2 7532 servers run with AMD SMT enabled, doubling the number of logical cores exposed to Linux. -2-Node Xeon Cascade Lake (2n-clx) +2-Node Xeon Cascadelake (2n-clx) --------------------------------- Three 2n-clx testbeds are in operation in FD.io labs. Each 2n-clx testbed @@ -128,7 +134,75 @@ NIC models: #. NIC-5: empty, future expansion. #. NIC-6: x710-DA4 4p10GE Intel. (For self-tests.) -All Intel Xeon Cascade Lake servers run with Intel Hyper-Threading enabled, +All Intel Xeon Cascadelake servers run with Intel Hyper-Threading enabled, +doubling the number of logical cores exposed to Linux. + +2-Node Xeon Icelake (2n-icx) EXPERIMENTAL +----------------------------------------- + +One 2n-icx testbed located in Intel labs was used for CSIT testing. It +is built with two SuperMicro SYS-740GP-TNRT servers. SUT is equipped +with two Intel Xeon Gold 6338N processors (48 MB Cache, 2.20 GHz, 32 +cores). TG is equiped with two Intel Xeon Ice Lake Platinum 8360Y +processors (54 MB Cache, 2.40 GHz, 36 cores). 2n-icx physical topology +is shown below. + +.. only:: latex + + .. raw:: latex + + \begin{figure}[H] + \centering + \graphicspath{{../_tmp/src/introduction/}} + \includegraphics[width=0.90\textwidth]{testbed-2n-icx} + \label{fig:testbed-2n-icx} + \end{figure} + +.. only:: html + + .. figure:: testbed-2n-icx.svg + :alt: testbed-2n-icx + :align: center + +SUT and TG servers are populated with the following NIC models: + +#. NIC-1: E810-2CQDA2 2p100GbE Intel. + +All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled, +doubling the number of logical cores exposed to Linux. + +3-Node Xeon Icelake (3n-icx) EXPERIMENTAL +----------------------------------------- + +One 3n-icx testbed located in Intel labs was used for CSIT testing. It +is built with three SuperMicro SYS-740GP-TNRT servers. SUTs are +equipped each with two Intel Xeon Platinum 8360Y processors (54 MB +Cache, 2.40 GHz, 36 cores). TG is equiped with two Intel Xeon Ice Lake +Platinum 8360Y processors (54 MB Cache, 2.40 GHz, 36 cores). 3n-icx +physical topology is shown below. + +.. only:: latex + + .. raw:: latex + + \begin{figure}[H] + \centering + \graphicspath{{../_tmp/src/introduction/}} + \includegraphics[width=0.90\textwidth]{testbed-3n-icx} + \label{fig:testbed-3n-icx} + \end{figure} + +.. only:: html + + .. figure:: testbed-3n-icx.svg + :alt: testbed-3n-icx + :align: center + +SUT and TG servers are populated with the following NIC models: + +#. NIC-1: E810-2CQDA2 2p100GbE Intel. + +All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled, doubling the number of logical cores exposed to Linux. 2-Node Xeon Skylake (2n-skx) |