diff options
author | Maciek Konstantynowicz <mkonstan@cisco.com> | 2017-10-30 21:28:43 +0000 |
---|---|---|
committer | Tibor Frank <tifrank@cisco.com> | 2017-10-31 11:53:21 +0000 |
commit | 737fbd3341638e90478979779b5ee6c0b0bf5c39 (patch) | |
tree | 44b891d199bf7d99c6921de037461697fce2429d /docs/report/vpp_performance_tests/overview.rst | |
parent | 5beb7d3d04a876ee37c7b9cf64b3e02366086968 (diff) |
csit report static content updates for rls1710.
Change-Id: I6744f1c206410564114ce7b9d06f840432f97ed2
Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/report/vpp_performance_tests/overview.rst')
-rw-r--r-- | docs/report/vpp_performance_tests/overview.rst | 24 |
1 files changed, 12 insertions, 12 deletions
diff --git a/docs/report/vpp_performance_tests/overview.rst b/docs/report/vpp_performance_tests/overview.rst index b7aecc1c38..c1302866fc 100644 --- a/docs/report/vpp_performance_tests/overview.rst +++ b/docs/report/vpp_performance_tests/overview.rst @@ -54,18 +54,18 @@ performance labs to address larger scale multi-interface and multi-NIC performance testing scenarios. For test cases that require DUT (VPP) to communicate with -VirtualMachines (VMs) / LinuxContainers (LXCs) over vhost-user/memif -interfaces, N of VM/LXC instances are created on SUT1 and SUT2. For N=1 -DUT forwards packets between vhost/memif and physical interfaces. For -N>1 DUT a logical service chain forwarding topology is created on DUT by -applying L2 or IPv4/IPv6 configuration depending on the test suite. DUT -test topology with N VM/LXC instances is shown in the figure below -including applicable packet flow thru the DUTs and VMs/LXCs (marked in -the figure with ``***``).:: +VirtualMachines (VMs) / Containers (Linux or Docker Containers) over +vhost-user/memif interfaces, N of VM/Ctr instances are created on SUT1 +and SUT2. For N=1 DUT forwards packets between vhost/memif and physical +interfaces. For N>1 DUT a logical service chain forwarding topology is +created on DUT by applying L2 or IPv4/IPv6 configuration depending on +the test suite. DUT test topology with N VM/Ctr instances is shown in +the figure below including applicable packet flow thru the DUTs and +VMs/Ctrs (marked in the figure with ``***``).:: +-------------------------+ +-------------------------+ | +---------+ +---------+ | | +---------+ +---------+ | - | |VM/LXC[1]| |VM/LXC[N]| | | |VM/LXC[1]| |VM/LXC[N]| | + | |VM/Ctr[1]| |VM/Ctr[N]| | | |VM/Ctr[1]| |VM/Ctr[N]| | | | ***** | | ***** | | | | ***** | | ***** | | | +--^---^--+ +--^---^--+ | | +--^---^--+ +--^---^--+ | | *| |* *| |* | | *| |* *| |* | @@ -85,8 +85,8 @@ the figure with ``***``).:: **********************| |********************** +-----------+ -For VM/LXC tests, packets are switched by DUT multiple times: twice for -a single VM/LXC, three times for two VMs/LXCs, N+1 times for N VMs/LXCs. +For VM/Ctr tests, packets are switched by DUT multiple times: twice for +a single VM/Ctr, three times for two VMs/Ctrs, N+1 times for N VMs/Ctrs. Hence the external throughput rates measured by TG and listed in this report must be multiplied by (N+1) to represent the actual DUT aggregate packet forwarding rate. @@ -99,7 +99,7 @@ thoughput for Phy-to-Phy (NIC-to-NIC, PCI-to-PCI) topology, is to expect the forwarding performance to be proportional to CPU core frequency, assuming CPU is the only limiting factor and all other SUT parameters equivalent to FD.io CSIT environment. The same rule of thumb can be also -applied for Phy-to-VM/LXC-to-Phy (NIC-to-VM/LXC-to-NIC) topology, but due to +applied for Phy-to-VM/Ctr-to-Phy (NIC-to-VM/Ctr-to-NIC) topology, but due to much higher dependency on intensive memory operations and sensitivity to Linux kernel scheduler settings and behaviour, this estimation may not always yield good enough accuracy. |