aboutsummaryrefslogtreecommitdiffstats
path: root/docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst
diff options
context:
space:
mode:
authorPeter Mikus <pmikus@cisco.com>2017-07-13 14:42:38 +0200
committerPeter Mikus <pmikus@cisco.com>2017-07-14 12:21:06 +0000
commitd9a08e59581aafe44d446b5bc1ce6ff86b2b173b (patch)
tree74902d592577616d7d5c1a115a42ef02d7139b67 /docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst
parentd6226b0df6d07f886184a5d35ff647dbdfe5d4ce (diff)
CSIT-618 CSIT rls1707 Report - Update I
Change-Id: I7c3af55db6cc89f03004db6ddf6fcf67965132a7 Signed-off-by: Peter Mikus <pmikus@cisco.com>
Diffstat (limited to 'docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst')
-rw-r--r--docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst116
1 files changed, 116 insertions, 0 deletions
diff --git a/docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst b/docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst
new file mode 100644
index 0000000000..09a44884c2
--- /dev/null
+++ b/docs/report/vpp_performance_tests/packet_throughput_graphs/ip6.rst
@@ -0,0 +1,116 @@
+IPv6 Routed-Forwarding
+======================
+
+Following sections include summary graphs of VPP Phy-to-Phy performance
+with IPv6 Routed-Forwarding, including NDR throughput (zero packet loss)
+and PDR throughput (<0.5% packet loss). Performance is reported for VPP
+running in multiple configurations of VPP worker thread(s), a.k.a. VPP
+data plane thread(s), and their physical CPU core(s) placement.
+
+NDR Throughput
+~~~~~~~~~~~~~~
+
+VPP NDR 78B packet throughput in 1t1c setup (1thread, 1core) is presented
+in the graph below.
+
+.. raw:: html
+
+ <iframe width="700" height="1000" frameborder="0" scrolling="no" src="../../_static/vpp/78B-1t1c-ethip6-ip6-ndrdisc.html"></iframe>
+
+*Figure 1. VPP 1thread 1core - NDR Throughput for Phy-to-Phy IPv6
+Routed-Forwarding.*
+
+CSIT source code for the test cases used for above plots can be found in CSIT
+git repository:
+
+.. code-block:: bash
+
+ $ cd $CSIT/tests/vpp/perf/ip6
+ $ grep -E "78B-1t1c-ethip6-ip6[a-z0-9]+-[a-z-]*ndrdisc" *
+
+ 10ge2p1x520-ethip6-ip6base-copwhtlistbase-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6base-copwhtlistbase-ndrdisc
+ 10ge2p1x520-ethip6-ip6base-iacldstbase-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6base-iacldstbase-ndrdisc
+ 10ge2p1x520-ethip6-ip6base-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6base-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale200k-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6scale200k-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale20k-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6scale20k-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale2m-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6scale2m-ndrdisc
+ 40ge2p1xl710-ethip6-ip6base-ndrpdrdisc.robot:| tc01-78B-1t1c-ethip6-ip6base-ndrdisc
+
+VPP NDR 78B packet throughput in 2t2c setup (2thread, 2core) is presented
+in the graph below.
+
+.. raw:: html
+
+ <iframe width="700" height="1000" frameborder="0" scrolling="no" src="../../_static/vpp/78B-2t2c-ethip6-ip6-ndrdisc.html"></iframe>
+
+*Figure 2. VPP 2threads 2cores - NDR Throughput for Phy-to-Phy IPv6
+Routed-Forwarding.*
+
+CSIT source code for the test cases used for above plots can be found in CSIT
+git repository:
+
+.. code-block:: bash
+
+ $ cd $CSIT/tests/vpp/perf/ip6
+ $ grep -E "78B-2t2c-ethip6-ip6[a-z0-9]+-[a-z-]*ndrdisc" *
+
+ 10ge2p1x520-ethip6-ip6base-copwhtlistbase-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6base-copwhtlistbase-ndrdisc
+ 10ge2p1x520-ethip6-ip6base-iacldstbase-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6base-iacldstbase-ndrdisc
+ 10ge2p1x520-ethip6-ip6base-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6base-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale200k-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6scale200k-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale20k-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6scale20k-ndrdisc
+ 10ge2p1x520-ethip6-ip6scale2m-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6scale2m-ndrdisc
+ 40ge2p1xl710-ethip6-ip6base-ndrpdrdisc.robot:| tc07-78B-2t2c-ethip6-ip6base-ndrdisc
+
+PDR Throughput
+~~~~~~~~~~~~~~
+
+VPP PDR 78B packet throughput in 1t1c setup (1thread, 1core) is presented
+in the graph below. PDR measured for 0.5% packet loss ratio.
+
+.. raw:: html
+
+ <iframe width="700" height="1000" frameborder="0" scrolling="no" src="../../_static/vpp/78B-1t1c-ethip6-ip6-pdrdisc.html"></iframe>
+
+*Figure 3. VPP 1thread 1core - PDR Throughput for Phy-to-Phy IPv6
+Routed-Forwarding.*
+
+CSIT source code for the test cases used for above plots can be found in CSIT
+git repository:
+
+.. code-block:: bash
+
+ $ cd $CSIT/tests/vpp/perf/ip6
+ $ grep -E "78B-1t1c-ethip6-ip6[a-z0-9]+-[a-z-]*pdrdisc" *
+
+ 10ge2p1x520-ethip6-ip6base-copwhtlistbase-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6base-copwhtlistbase-pdrdisc
+ 10ge2p1x520-ethip6-ip6base-iacldstbase-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6base-iacldstbase-pdrdisc
+ 10ge2p1x520-ethip6-ip6base-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6base-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale200k-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6scale200k-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale20k-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6scale20k-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale2m-ndrpdrdisc.robot:| tc02-78B-1t1c-ethip6-ip6scale2m-pdrdisc
+
+VPP PDR 78B packet throughput in 2t2c setup (2thread, 2core) is presented
+in the graph below. PDR measured for 0.5% packet loss ratio.
+
+.. raw:: html
+
+ <iframe width="700" height="1000" frameborder="0" scrolling="no" src="../../_static/vpp/78B-2t2c-ethip6-ip6-pdrdisc.html"></iframe>
+
+*Figure 4. VPP 2thread 2core - PDR Throughput for Phy-to-Phy IPv6
+Routed-Forwarding.*
+
+CSIT source code for the test cases used for above plots can be found in CSIT
+git repository:
+
+.. code-block:: bash
+
+ $ cd $CSIT/tests/vpp/perf/ip6
+ $ grep -E "78B-2t2c-ethip6-ip6[a-z0-9]+-[a-z-]*pdrdisc" *
+
+ 10ge2p1x520-ethip6-ip6base-copwhtlistbase-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6base-copwhtlistbase-pdrdisc
+ 10ge2p1x520-ethip6-ip6base-iacldstbase-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6base-iacldstbase-pdrdisc
+ 10ge2p1x520-ethip6-ip6base-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6base-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale200k-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6scale200k-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale20k-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6scale20k-pdrdisc
+ 10ge2p1x520-ethip6-ip6scale2m-ndrpdrdisc.robot:| tc08-78B-2t2c-ethip6-ip6scale2m-pdrdisc