diff options
author | Maciek Konstantynowicz <mkonstan@cisco.com> | 2017-07-19 23:14:00 +0100 |
---|---|---|
committer | Peter Mikus <pmikus@cisco.com> | 2017-07-20 06:33:07 +0000 |
commit | 133b8b6c080d0372bccf7b803ddad1301abc9dd1 (patch) | |
tree | cb903bf3a75aedfc356fd0f916cf4731c064103c /docs/report/vpp_performance_tests | |
parent | 02b0011703354f4caaf476ff4cac0ec4ccd8e43a (diff) |
rls1707 report: edits of vpp_performance_tests/test_environment.rst
Change-Id: Ic0a544e12ab1a3b7caf39ef1a45db412b887bff7
Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/report/vpp_performance_tests')
-rw-r--r-- | docs/report/vpp_performance_tests/test_environment.rst | 154 |
1 files changed, 18 insertions, 136 deletions
diff --git a/docs/report/vpp_performance_tests/test_environment.rst b/docs/report/vpp_performance_tests/test_environment.rst index 68f4365a4d..9392259a97 100644 --- a/docs/report/vpp_performance_tests/test_environment.rst +++ b/docs/report/vpp_performance_tests/test_environment.rst @@ -1,140 +1,20 @@ Test Environment
================
-To execute performance tests, there are three identical testbeds, each testbed
-consists of two SUTs and one TG.
+CSIT performance tests are executed on the three identical physical
+testbeds hosted by Linux Foundation for FD.io project. Each testbed
+consists of two servers acting as Systems Under Test (SUT) and one
+server acting as Traffic Generator (TG).
-Naming Convention
------------------
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-- testbedname: testbedN.
-- hostname:
-
- - traffic-generator: tN-tgW.
- - system-under-testX: tN-sutX.
-
-- portnames:
-
- - tN-tgW-cY/pZ.
- - tN-sutX-cY/pZ.
-
-- where:
-
- - N - testbed number.
- - tgW - server acts as traffic-generator with W index.
- - sutX - server acts as system-under-test with X index.
- - Y - PCIe slot number denoting a NIC card number within the host.
-
- - Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.
- - Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.
- - Y=m - the MLOM slot.
-
- - Z - port number on the NIC card.
-
-Server HW Configuration
------------------------
-
-CSIT testbed contains following three HW configuration types of UCS x86 servers,
-across total of ten servers provided:
-
-#. Type-1: Purpose - VPP functional and performance conformance testing.
-
- - Quantity: 6 computers as SUT hosts (Systems Under Test).
- - Physical connectivity:
-
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
-
- - Main HW configuration:
-
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-
- - NICs configuration:
-
- - Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-
- - PCIe Slot1: Cisco VIC 1385 2p40GE.
-
- - PCIe Slot2: Intel NIC x520 2p10GE.
- - PCIe Slot3: empty.
-
- - Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+Server Specification and Configuration
+--------------------------------------
- - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
+Complete specification and configuration of compute servers used in CSIT
+physical testbeds is maintained on wiki page
+`CSIT LF Testbeds <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
-#. Type-2: Purpose - VPP functional and performance conformance testing.
-
- - Quantity: 3 computers as TG hosts (Traffic Generators).
- - Physical connectivity:
-
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
-
- - Main HW configuration:
-
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-
- - NICs configuration:
-
- - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-
- - PCIe Slot1: Intel NIC xl710 2p40GE.
- - PCIe Slot2: Intel NIC x710 2p10GE.
- - PCIe Slot3: Intel NIC x710 2p10GE.
-
- - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel NIC x710 2p10GE.
-
- - MLOM slot: empty.
-
-#. Type-3: Purpose - VIRL functional conformance.
-
- - Quantity: 3 computers as VIRL hosts.
- - Physical connectivity:
-
- - CIMC and host management ports.
- - no NIC ports, standalone setup.
-
- - Main HW configuration:
-
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
-
- - NICs configuration:
-
- - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-
- - no cards.
-
- - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-
- - no cards.
-
- - MLOM slot: empty.
-
-SUT Configuration - Host HW
----------------------------
-Host hardware details (CPU, memory, NIC layout) and physical topology are
-described in detail in
-`LF FDio CSIT testbed wiki page <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
+SUT Configuration
+-----------------
**Host configuration**
@@ -253,8 +133,8 @@ In addition to CIMC and Management, each TG has 4x Intel X710 10GB NIC - 1x Intel X710 NIC (10GB, 2 ports),
- 1x Cisco VIC 1227 (10GB, 2 ports).
-This allows for a total of five ring topologies, each using ports on specific
-NIC model, enabling per NIC model benchmarking.
+This allows for a total of five ring topologies, each using ports on
+specific NIC model, enabling per NIC model benchmarking.
- 0a:00.0 Ethernet controller: Intel Corporation 82599ES 10-Gigabit SFI/SFP+
Network Connection (rev 01) Subsystem: Intel Corporation Ethernet Server
@@ -286,10 +166,12 @@ NIC model, enabling per NIC model benchmarking. SUT Configuration - Host OS Linux
---------------------------------
-Software details (OS, configuration) are described in `LF FDio CSIT testbed
-wiki page <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
+Software details (OS, configuration) of physical testbeds are maintained
+on wiki page
+`CSIT LF Testbeds <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
-System provisioning is done by combination of PXE boot unattented install and
+System provisioning is done by combination of PXE boot unattented
+install and
`Ansible <https://www.ansible.com>`_ described in `CSIT Testbed Setup`_.
Below a subset of the running configuration:
|