aboutsummaryrefslogtreecommitdiffstats
path: root/docs/report
diff options
context:
space:
mode:
authorMaciek Konstantynowicz <mkonstan@cisco.com>2017-10-20 13:23:01 +0100
committerTibor Frank <tifrank@cisco.com>2017-10-24 06:42:13 +0000
commit21707ceb638db86090b8740aad652cbd4e783302 (patch)
tree4773bffc51c6e8a9b35d11530c987e33df9f5bd2 /docs/report
parent82e59c20f7b7fee0a444fde222bb2325e497ab6d (diff)
rls1710 report: vpp performance methodology updates.
Change-Id: Ifc3b06dc8be0c82b8c424fb599eeac5a8e1f286f Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/report')
-rw-r--r--docs/report/vpp_performance_tests/overview.rst58
1 files changed, 45 insertions, 13 deletions
diff --git a/docs/report/vpp_performance_tests/overview.rst b/docs/report/vpp_performance_tests/overview.rst
index 89f5958075..669c5d10b1 100644
--- a/docs/report/vpp_performance_tests/overview.rst
+++ b/docs/report/vpp_performance_tests/overview.rst
@@ -1,6 +1,8 @@
Overview
========
+.. _tested_physical_topologies:
+
Tested Physical Topologies
--------------------------
@@ -52,7 +54,7 @@ performance labs to address larger scale multi-interface and multi-NIC
performance testing scenarios.
For test cases that require DUT (VPP) to communicate with
-VirtualMachines(VMs)/LinuxContainers(LXCs) over vhost-user/memif
+VirtualMachines (VMs) / LinuxContainers (LXCs) over vhost-user/memif
interfaces, N of VM/LXC instances are created on SUT1 and SUT2. For N=1
DUT forwards packets between vhost/memif and physical interfaces. For
N>1 DUT a logical service chain forwarding topology is created on DUT by
@@ -305,18 +307,48 @@ environment settings:
threads less susceptible to other Linux OS system tasks hijacking CPU
cores running those data plane threads.
-Methodology: LXC Container memif
---------------------------------
-
-CSIT |release| introduced new tests - VPP Memif virtual interface (shared memory
-interface) tests interconnecting VPP instances over memif. VPP vswitch instance
-runs in bare-metal user-mode handling Intel x520 NIC 10GbE interfaces and
-connecting over memif (Master side) virtual interfaces to another instance of
-VPP running in bare-metal :abbr:`LXC (Linux Container)` with memif virtual
-interfaces (Slave side). LXC runs in a priviliged mode with VPP data plane worker
-threads pinned to dedicated physical CPU cores per usual CSIT practice. Both VPP
-run the same version of software. This test topology is equivalent to existing
-tests with vhost-user and VMs.
+Methodology: LXC and Docker Containers memif
+--------------------------------------------
+
+CSIT |release| introduced additional tests taking advantage of VPP memif
+virtual interface (shared memory interface) tests to interconnect VPP
+instances. VPP vswitch instance runs in bare-metal user-mode handling
+Intel x520 NIC 10GbE interfaces and connecting over memif (Master side)
+virtual interfaces to more instances of VPP running in :abbr:`LXC (Linux
+Container)` or in Docker Containers, both with memif virtual interfaces
+(Slave side). LXCs and Docker Containers run in a priviliged mode with
+VPP data plane worker threads pinned to dedicated physical CPU cores per
+usual CSIT practice. All VPP instances run the same version of software.
+This test topology is equivalent to existing tests with vhost-user and
+VMs as described earlier in :ref:`tested_physical_topologies`.
+
+More information about CSIT LXC and Docker Container setup and control
+is available in :ref:`containter_orchestration_in_csit`.
+
+Methodology: Container Topologies Orchestrated by K8s
+-----------------------------------------------------
+
+CSIT |release| introduced new tests of Container topologies connected
+over the memif virtual interface (shared memory interface). In order to
+provide simple topology coding flexibility and extensibility container
+orchestration is done with `Kubernetes <https://github.com/kubernetes>`_
+using `Docker <https://github.com/docker>`_ images for all container
+applications including VPP. `Ligato <https://github.com/ligato>`_ is
+used to address the container networking orchestration that is
+integrated with K8s, including memif support.
+
+For these tests VPP vswitch instance runs in a Docker Container handling
+Intel x520 NIC 10GbE interfaces and connecting over memif (Master side)
+virtual interfaces to more instances of VPP running in Docker Containers
+with memif virtual interfaces (Slave side). All Docker Containers run in
+a priviliged mode with VPP data plane worker threads pinned to dedicated
+physical CPU cores per usual CSIT practice. All VPP instances run the
+same version of software. This test topology is equivalent to existing
+tests with vhost-user and VMs as described earlier in
+:ref:`tested_physical_topologies`.
+
+More information about CSIT Container Topologies Orchestrated by K8s is
+available in :ref:`containter_orchestration_in_csit`.
Methodology: IPSec with Intel QAT HW cards
------------------------------------------