diff options
author | pmikus <peter.mikus@protonmail.ch> | 2023-03-09 13:32:33 +0000 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2023-03-15 10:06:55 +0000 |
commit | b928e56347c682fdb9762ccbe2f368329d4037e4 (patch) | |
tree | 9c0f6a02efc1704821229b8e18a23468fdf8674a /docs/test_code_guidelines.rst | |
parent | ddcdf45806d0efa9e89dd4446b4c7da39cfb27a8 (diff) |
feat(docs): Hugo
Signed-off-by: pmikus <peter.mikus@protonmail.ch>
Change-Id: Id8b43ef1f31f39b19a0629c52581514fda278f3b
Diffstat (limited to 'docs/test_code_guidelines.rst')
-rw-r--r-- | docs/test_code_guidelines.rst | 319 |
1 files changed, 0 insertions, 319 deletions
diff --git a/docs/test_code_guidelines.rst b/docs/test_code_guidelines.rst deleted file mode 100644 index 33ac72764f..0000000000 --- a/docs/test_code_guidelines.rst +++ /dev/null @@ -1,319 +0,0 @@ -CSIT Test Code Guidelines -^^^^^^^^^^^^^^^^^^^^^^^^^ - -The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", -"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", -"MAY", and "OPTIONAL" in this document are to be interpreted as -described in `BCP 14 <https://tools.ietf.org/html/bcp14>`_ -`[RFC2119] <https://tools.ietf.org/html/rfc2119>`_ -`[RFC8174] <https://tools.ietf.org/html/rfc8174>`_ -when, and only when, they appear in all capitals, as shown here. - -This document SHALL describe guidelines for writing reliable, maintainable, -reusable and readable code for CSIT. - -TODO: Decide whether to use "you SHALL", "contributors SHALL", -or "code SHALL be"; convert other forms to the chosen one. - -RobotFramework test case files and resource files -~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ - -+ General - - + Contributors SHOULD look at requirements.txt in root CSIT directory - for the currently used Robot Framework version. - Contributors SHOULD read `Robot Framework User Guide - <http://robotframework.org/robotframework/latest/RobotFrameworkUserGuide.html>`_ - for more details. - - + RobotFramework test case files and resource files - SHALL use special extension .robot - - + Pipe and space separated file format (without trailing pipe - and without pipe aligning) SHALL be used. - Tabs are invisible characters, which are error prone. - 4-spaces separation is prone to accidental double space - acting as a separator. - - + Files SHALL be encoded in UTF-8 (the default Robot source file encoding). - Usage of non-ASCII characters SHOULD be avoided if possible. - It is RECOMMENDED to `escape - <http://robotframework.org/robotframework/latest/RobotFrameworkUserGuide.html#escaping>`_ - non-ASCII characters. - - + Line length SHALL be limited to 80 characters. - - + There SHALL be licence text (FIXME: add link) present - at the beginning of each file. - - + Copy-pasting of the code NOT RECOMMENDED practice, any code that could be - re-used SHOULD be put into a library (Robot resource, Python library, ...). - -+ Test cases - - + It is RECOMMENDED to use data-driven test case definitions - anytime suite contains test cases similar in structure. - Typically, a suite SHOULD define a Template keyword, and test cases - SHOULD only specify tags and argument values:: - - *** Settings *** - | Test Template | Local Template - ... - - *** Test Cases *** - | tc01-64B-1c-eth-l2patch-mrr - | | [Tags] | 64B | 1C - | | framesize=${64} | phy_cores=${1} - - + Test case templates (or testcases) SHALL be written in Behavior-driven style - i.e. in readable English, so that even non-technical project stakeholders - can understand it:: - - *** Keywords *** - | Local Template - | | [Documentation] - | | ... | [Cfg] DUT runs L2 patch config with ${phy_cores} phy core(s). - | | ... | [Ver] Measure NDR and PDR values using MLRsearch algorithm.\ - | | ... - | | ... | *Arguments:* - | | ... | - frame_size - Framesize in Bytes in integer - | | ... | or string (IMIX_v4_1). Type: integer, string - | | ... | - phy_cores - Number of physical cores. Type: integer - | | ... | - rxq - Number of RX queues, default value: ${None}. - | | ... | Type: integer - | | ... - | | [Arguments] | ${frame_size} | ${phy_cores} | ${rxq}=${None} - | | ... - | | Set Test Variable | \${frame_size} - | | ... - | | Given Add worker threads and rxqueues to all DUTs - | | ... | ${phy_cores} | ${rxq} - | | And Add PCI devices to all DUTs - | | Set Max Rate And Jumbo And Handle Multi Seg - | | And Apply startup configuration on all VPP DUTs - | | When Initialize L2 patch - | | Then Find NDR and PDR intervals using optimized search - - + Every suite and test case template (or testcase) - SHALL contain short documentation. - Generated CSIT web pages display the documentation. - For an example generated page, see: - https://docs.fd.io/csit/rls1807/doc/tests.vpp.perf.tcp.html - - + You SHOULD NOT use hard-coded constants. - It is RECOMMENDED to use the variable table - (\*\*\*Variables\*\*\*) to define test case specific values. - You SHALL use the assignment sign = after the variable name - to make assigning variables slightly more explicit:: - - *** Variables *** - | ${traffic_profile}= | trex-stl-2n-ethip4-ip4src254 - - + Common test case specific settings of the test environment SHALL be done - in Test Setup keyword defined in the Setting table. - - + Run Keywords construction is RECOMMENDED if it is more readable - than a keyword. - - + Separate keyword is RECOMMENDED if the construction is less readable. - - + Post-test cleaning and processing actions SHALL be done in Test Teardown - part of the Setting table (e.g. download statistics from VPP nodes). - This part is executed even if the test case has failed. On the other hand - it is possible to disable the tear-down from command line, thus leaving - the system in “broken” state for investigation. - - + Every testcase SHALL be correctly tagged. List of defined tags is in - csit/docs/tag_documentation.rst (FIXME: rst-ize the link) file. - - + Whenever possible, common tags SHALL be set using Force Tags - in Settings table. - - + User high-level keywords specific for the particular test suite - SHOULD be implemented in the Keywords table of suitable Robot resource file - to enable readability and code-reuse. - - + Such keywords MAY be implemented in Keywords table of the suite instead, - if the contributor believes no other test will use such keywords. - But this is NOT RECOMMENDED in general, as keywords in Resources - are easier to maintain. - - + All test case names (and suite names) SHALL conform - to current naming convention. - https://wiki.fd.io/view/CSIT/csit-test-naming - TODO: Migrate the convention document to .rst and re-link. - - + Frequently, different suites use the same test case layout. - It is RECOMMENDED to use autogeneration scripts available, - possibly extending them if their current functionality is not sufficient. - -+ Resource files - - + SHALL be used to implement higher-level keywords that are used in test cases - or other higher-level (or medium-level) keywords. - - + Every keyword SHALL contain Documentation where the purpose and arguments - of the keyword are described. Also document types, return values, - and any specific assumptions the particular keyword relies on. - - + A keyword usage example SHALL be the part of the Documentation. - The example SHALL use pipe and space separated format - (with escaped pipes and) with a trailing pipe. - - + The reason was possbile usage of Robot's libdoc tool - to generate tests and resources documentation. In that case - example keyword usage would be rendered in table. - - + TODO: We should adapt it for current tool - used to generate the documentation. - - + Keyword name SHALL describe what the keyword does, - specifically and in a reasonable length (“short sentence”). - - + Keyword names SHALL be short enough for call sites - to fit within line length limit. - - + If a keyword argument has a most commonly used value, it is RECOMMENDED - to set it as default. This makes keyword code longer, - but suite code shorter, and readability (and maintainability) - of suites SHALL always more important. - - + If there is intermediate data (created by one keyword, to be used - by another keyword) of singleton semantics (it is clear that the test case - can have at most one instance of such data, even if the instance - is complex, for example ${nodes}), it is RECOMMENDED to store it - in test variables. You SHALL document test variables read or written - by a keyword. This makes the test template code less verbose. - As soon as the data instance is not unique, you SHALL pass it around - via arguments and return values explicitly (this makes lower level keywords - more reusable and less bug prone). - - + It is RECOMMENDED to pass arguments explicitly via [Arguments] line. - Setting test variables takes more space and is less explicit. - Using arguments embedded in keyword name makes them less visible, - and it makes it harder for the line containing the resulting long name - to fit into the maximum character limit, so you SHOULD NOT use them. - -Python library files -~~~~~~~~~~~~~~~~~~~~ - -TODO: Add guidelines for Python scripts (both utilities called by test on nodes -and unrelated ones such as PAL) if there are any (in addition to library ones). - -+ General - - + SHALL be used to implement low-level keywords that are called from - resource files (of higher-level keywords) or from test cases. - - + TODO: Discuss debugability, speed, logging, complexity of logic. - - + Higher-level keywords MAY be implemented in python library file too. - it is RECOMMENDED especially in the case that their implementation - in resource file would be too difficult or impossible, - e.g. complex data structures or functional programming. - - + Every keyword, Python module, class, method, enum SHALL contain - docstring with the short description and used input parameters - and possible return value(s) or raised exceptions. - - + The docstrings SHOULD conform to - `PEP 257 <https://www.python.org/dev/peps/pep-0257/>`_ - and other quality standards. - - + CSIT contributions SHALL use a specific formatting for documenting - arguments, return values and similar. - - + FIXME: Find a link which documents sthis style. - it is based on Sphinx, but very different from - `Napoleon style - <https://sphinxcontrib-napoleon.readthedocs.io/en/latest/example_numpy.html>`_. - - + Keyword usage examples MAY be grouped and used - in the class/module documentation string, to provide better overview - of the usage and relationships between keywords. - - + Keyword name SHALL describe what the keyword does, - specifically and in a reasonable length (“short sentence”). - See https://wiki.fd.io/view/CSIT/csit-test-naming - - + Python implementation of a keyword is a function, - so its name in the python library should be lowercase_with_underscores. - Robot call sites should usename with first letter capitalized, and spaces. - - + FIXME: create Robot keyword naming item in proper place. - -+ Coding - - + It is RECOMMENDED to use some standard development tool - (e.g. PyCharm Community Edition) and follow - `PEP-8 <https://www.python.org/dev/peps/pep-0008/>`_ recommendations. - - + All python code (not only Robot libraries) SHALL adhere to PEP-8 standard. - This is reported by CSIT Jenkins verify job. - - + Indentation: You SHALL NOT use tab for indents! - Indent is defined as four spaces. - - + Line length: SHALL be limited to 80 characters. - - + CSIT Python code assumes PYTHONPATH is set - to the root of cloned CSIT git repository, creating a tree of sub-packages. - You SHALL use that tree for importing, for example:: - - from resources.libraries.python.ssh import exec_cmd_no_error - - + Imports SHALL be grouped in the following order: - - #. standard library imports, - #. related third party imports, - #. local application/library specific imports. - - You SHALL put a blank line between each group of imports. - - + You SHALL use two blank lines between top-level definitions, - one blank line between method definitions. - - + You SHALL NOT execute any active code on library import. - - + You SHALL NOT use global variables inside library files. - - + You MAY define constants inside library files. - - + It is NOT RECOMMENDED to use hard-coded constants (e.g. numbers, - paths without any description). It is RECOMMENDED to use - configuration file(s), like /csit/resources/libraries/python/Constants.py, - with appropriate comments. - - + The code SHALL log at the lowest possible level of implementation, - for debugging purposes. You SHALL use same style for similar events. - You SHALL keep logging as verbose as necessary. - - + You SHALL use the most appropriate exception not general one (Exception) - if possible. You SHOULD create your own exception - if necessary and implement there logging, level debug. - - + You MAY use RuntimeException for generally unexpected failures. - - + It is RECOMMENDED to use RuntimeError also for - infrastructure failures, e.g. losing SSH connection to SUT. - - + You MAY use EnvironmentError and its cublasses instead, - if the distinction is informative for callers. - - + It is RECOMMENDED to use AssertionError when SUT is at fault. - - + For each class (e.g. exception) it is RECOMMENDED to implement __repr__() - which SHALL return a string usable as a constructor call - (including repr()ed arguments). - When logging, you SHOULD log the repr form, unless the internal structure - of the object in question would likely result in too long output. - This is helpful for debugging. - - + For composing and formatting strings, you SHOULD use .format() - with named arguments. - Example: "repr() of name: {name!r}".format(name=name) - -Bash scripts and libraries -~~~~~~~~~~~~~~~~~~~~~~~~~~ - -TODO: Link or copy the bash_code_style.rst document here. |