aboutsummaryrefslogtreecommitdiffstats
path: root/docs/test_code_guidelines.rst
diff options
context:
space:
mode:
authorpmikus <peter.mikus@protonmail.ch>2023-03-09 13:32:33 +0000
committerPeter Mikus <peter.mikus@protonmail.ch>2023-03-15 10:06:55 +0000
commitb928e56347c682fdb9762ccbe2f368329d4037e4 (patch)
tree9c0f6a02efc1704821229b8e18a23468fdf8674a /docs/test_code_guidelines.rst
parentddcdf45806d0efa9e89dd4446b4c7da39cfb27a8 (diff)
feat(docs): Hugo
Signed-off-by: pmikus <peter.mikus@protonmail.ch> Change-Id: Id8b43ef1f31f39b19a0629c52581514fda278f3b
Diffstat (limited to 'docs/test_code_guidelines.rst')
-rw-r--r--docs/test_code_guidelines.rst319
1 files changed, 0 insertions, 319 deletions
diff --git a/docs/test_code_guidelines.rst b/docs/test_code_guidelines.rst
deleted file mode 100644
index 33ac72764f..0000000000
--- a/docs/test_code_guidelines.rst
+++ /dev/null
@@ -1,319 +0,0 @@
-CSIT Test Code Guidelines
-^^^^^^^^^^^^^^^^^^^^^^^^^
-
-The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
-"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED",
-"MAY", and "OPTIONAL" in this document are to be interpreted as
-described in `BCP 14 <https://tools.ietf.org/html/bcp14>`_
-`[RFC2119] <https://tools.ietf.org/html/rfc2119>`_
-`[RFC8174] <https://tools.ietf.org/html/rfc8174>`_
-when, and only when, they appear in all capitals, as shown here.
-
-This document SHALL describe guidelines for writing reliable, maintainable,
-reusable and readable code for CSIT.
-
-TODO: Decide whether to use "you SHALL", "contributors SHALL",
-or "code SHALL be"; convert other forms to the chosen one.
-
-RobotFramework test case files and resource files
-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-+ General
-
- + Contributors SHOULD look at requirements.txt in root CSIT directory
- for the currently used Robot Framework version.
- Contributors SHOULD read `Robot Framework User Guide
- <http://robotframework.org/robotframework/latest/RobotFrameworkUserGuide.html>`_
- for more details.
-
- + RobotFramework test case files and resource files
- SHALL use special extension .robot
-
- + Pipe and space separated file format (without trailing pipe
- and without pipe aligning) SHALL be used.
- Tabs are invisible characters, which are error prone.
- 4-spaces separation is prone to accidental double space
- acting as a separator.
-
- + Files SHALL be encoded in UTF-8 (the default Robot source file encoding).
- Usage of non-ASCII characters SHOULD be avoided if possible.
- It is RECOMMENDED to `escape
- <http://robotframework.org/robotframework/latest/RobotFrameworkUserGuide.html#escaping>`_
- non-ASCII characters.
-
- + Line length SHALL be limited to 80 characters.
-
- + There SHALL be licence text (FIXME: add link) present
- at the beginning of each file.
-
- + Copy-pasting of the code NOT RECOMMENDED practice, any code that could be
- re-used SHOULD be put into a library (Robot resource, Python library, ...).
-
-+ Test cases
-
- + It is RECOMMENDED to use data-driven test case definitions
- anytime suite contains test cases similar in structure.
- Typically, a suite SHOULD define a Template keyword, and test cases
- SHOULD only specify tags and argument values::
-
- *** Settings ***
- | Test Template | Local Template
- ...
-
- *** Test Cases ***
- | tc01-64B-1c-eth-l2patch-mrr
- | | [Tags] | 64B | 1C
- | | framesize=${64} | phy_cores=${1}
-
- + Test case templates (or testcases) SHALL be written in Behavior-driven style
- i.e. in readable English, so that even non-technical project stakeholders
- can understand it::
-
- *** Keywords ***
- | Local Template
- | | [Documentation]
- | | ... | [Cfg] DUT runs L2 patch config with ${phy_cores} phy core(s).
- | | ... | [Ver] Measure NDR and PDR values using MLRsearch algorithm.\
- | | ...
- | | ... | *Arguments:*
- | | ... | - frame_size - Framesize in Bytes in integer
- | | ... | or string (IMIX_v4_1). Type: integer, string
- | | ... | - phy_cores - Number of physical cores. Type: integer
- | | ... | - rxq - Number of RX queues, default value: ${None}.
- | | ... | Type: integer
- | | ...
- | | [Arguments] | ${frame_size} | ${phy_cores} | ${rxq}=${None}
- | | ...
- | | Set Test Variable | \${frame_size}
- | | ...
- | | Given Add worker threads and rxqueues to all DUTs
- | | ... | ${phy_cores} | ${rxq}
- | | And Add PCI devices to all DUTs
- | | Set Max Rate And Jumbo And Handle Multi Seg
- | | And Apply startup configuration on all VPP DUTs
- | | When Initialize L2 patch
- | | Then Find NDR and PDR intervals using optimized search
-
- + Every suite and test case template (or testcase)
- SHALL contain short documentation.
- Generated CSIT web pages display the documentation.
- For an example generated page, see:
- https://docs.fd.io/csit/rls1807/doc/tests.vpp.perf.tcp.html
-
- + You SHOULD NOT use hard-coded constants.
- It is RECOMMENDED to use the variable table
- (\*\*\*Variables\*\*\*) to define test case specific values.
- You SHALL use the assignment sign = after the variable name
- to make assigning variables slightly more explicit::
-
- *** Variables ***
- | ${traffic_profile}= | trex-stl-2n-ethip4-ip4src254
-
- + Common test case specific settings of the test environment SHALL be done
- in Test Setup keyword defined in the Setting table.
-
- + Run Keywords construction is RECOMMENDED if it is more readable
- than a keyword.
-
- + Separate keyword is RECOMMENDED if the construction is less readable.
-
- + Post-test cleaning and processing actions SHALL be done in Test Teardown
- part of the Setting table (e.g. download statistics from VPP nodes).
- This part is executed even if the test case has failed. On the other hand
- it is possible to disable the tear-down from command line, thus leaving
- the system in “broken” state for investigation.
-
- + Every testcase SHALL be correctly tagged. List of defined tags is in
- csit/docs/tag_documentation.rst (FIXME: rst-ize the link) file.
-
- + Whenever possible, common tags SHALL be set using Force Tags
- in Settings table.
-
- + User high-level keywords specific for the particular test suite
- SHOULD be implemented in the Keywords table of suitable Robot resource file
- to enable readability and code-reuse.
-
- + Such keywords MAY be implemented in Keywords table of the suite instead,
- if the contributor believes no other test will use such keywords.
- But this is NOT RECOMMENDED in general, as keywords in Resources
- are easier to maintain.
-
- + All test case names (and suite names) SHALL conform
- to current naming convention.
- https://wiki.fd.io/view/CSIT/csit-test-naming
- TODO: Migrate the convention document to .rst and re-link.
-
- + Frequently, different suites use the same test case layout.
- It is RECOMMENDED to use autogeneration scripts available,
- possibly extending them if their current functionality is not sufficient.
-
-+ Resource files
-
- + SHALL be used to implement higher-level keywords that are used in test cases
- or other higher-level (or medium-level) keywords.
-
- + Every keyword SHALL contain Documentation where the purpose and arguments
- of the keyword are described. Also document types, return values,
- and any specific assumptions the particular keyword relies on.
-
- + A keyword usage example SHALL be the part of the Documentation.
- The example SHALL use pipe and space separated format
- (with escaped pipes and) with a trailing pipe.
-
- + The reason was possbile usage of Robot's libdoc tool
- to generate tests and resources documentation. In that case
- example keyword usage would be rendered in table.
-
- + TODO: We should adapt it for current tool
- used to generate the documentation.
-
- + Keyword name SHALL describe what the keyword does,
- specifically and in a reasonable length (“short sentence”).
-
- + Keyword names SHALL be short enough for call sites
- to fit within line length limit.
-
- + If a keyword argument has a most commonly used value, it is RECOMMENDED
- to set it as default. This makes keyword code longer,
- but suite code shorter, and readability (and maintainability)
- of suites SHALL always more important.
-
- + If there is intermediate data (created by one keyword, to be used
- by another keyword) of singleton semantics (it is clear that the test case
- can have at most one instance of such data, even if the instance
- is complex, for example ${nodes}), it is RECOMMENDED to store it
- in test variables. You SHALL document test variables read or written
- by a keyword. This makes the test template code less verbose.
- As soon as the data instance is not unique, you SHALL pass it around
- via arguments and return values explicitly (this makes lower level keywords
- more reusable and less bug prone).
-
- + It is RECOMMENDED to pass arguments explicitly via [Arguments] line.
- Setting test variables takes more space and is less explicit.
- Using arguments embedded in keyword name makes them less visible,
- and it makes it harder for the line containing the resulting long name
- to fit into the maximum character limit, so you SHOULD NOT use them.
-
-Python library files
-~~~~~~~~~~~~~~~~~~~~
-
-TODO: Add guidelines for Python scripts (both utilities called by test on nodes
-and unrelated ones such as PAL) if there are any (in addition to library ones).
-
-+ General
-
- + SHALL be used to implement low-level keywords that are called from
- resource files (of higher-level keywords) or from test cases.
-
- + TODO: Discuss debugability, speed, logging, complexity of logic.
-
- + Higher-level keywords MAY be implemented in python library file too.
- it is RECOMMENDED especially in the case that their implementation
- in resource file would be too difficult or impossible,
- e.g. complex data structures or functional programming.
-
- + Every keyword, Python module, class, method, enum SHALL contain
- docstring with the short description and used input parameters
- and possible return value(s) or raised exceptions.
-
- + The docstrings SHOULD conform to
- `PEP 257 <https://www.python.org/dev/peps/pep-0257/>`_
- and other quality standards.
-
- + CSIT contributions SHALL use a specific formatting for documenting
- arguments, return values and similar.
-
- + FIXME: Find a link which documents sthis style.
- it is based on Sphinx, but very different from
- `Napoleon style
- <https://sphinxcontrib-napoleon.readthedocs.io/en/latest/example_numpy.html>`_.
-
- + Keyword usage examples MAY be grouped and used
- in the class/module documentation string, to provide better overview
- of the usage and relationships between keywords.
-
- + Keyword name SHALL describe what the keyword does,
- specifically and in a reasonable length (“short sentence”).
- See https://wiki.fd.io/view/CSIT/csit-test-naming
-
- + Python implementation of a keyword is a function,
- so its name in the python library should be lowercase_with_underscores.
- Robot call sites should usename with first letter capitalized, and spaces.
-
- + FIXME: create Robot keyword naming item in proper place.
-
-+ Coding
-
- + It is RECOMMENDED to use some standard development tool
- (e.g. PyCharm Community Edition) and follow
- `PEP-8 <https://www.python.org/dev/peps/pep-0008/>`_ recommendations.
-
- + All python code (not only Robot libraries) SHALL adhere to PEP-8 standard.
- This is reported by CSIT Jenkins verify job.
-
- + Indentation: You SHALL NOT use tab for indents!
- Indent is defined as four spaces.
-
- + Line length: SHALL be limited to 80 characters.
-
- + CSIT Python code assumes PYTHONPATH is set
- to the root of cloned CSIT git repository, creating a tree of sub-packages.
- You SHALL use that tree for importing, for example::
-
- from resources.libraries.python.ssh import exec_cmd_no_error
-
- + Imports SHALL be grouped in the following order:
-
- #. standard library imports,
- #. related third party imports,
- #. local application/library specific imports.
-
- You SHALL put a blank line between each group of imports.
-
- + You SHALL use two blank lines between top-level definitions,
- one blank line between method definitions.
-
- + You SHALL NOT execute any active code on library import.
-
- + You SHALL NOT use global variables inside library files.
-
- + You MAY define constants inside library files.
-
- + It is NOT RECOMMENDED to use hard-coded constants (e.g. numbers,
- paths without any description). It is RECOMMENDED to use
- configuration file(s), like /csit/resources/libraries/python/Constants.py,
- with appropriate comments.
-
- + The code SHALL log at the lowest possible level of implementation,
- for debugging purposes. You SHALL use same style for similar events.
- You SHALL keep logging as verbose as necessary.
-
- + You SHALL use the most appropriate exception not general one (Exception)
- if possible. You SHOULD create your own exception
- if necessary and implement there logging, level debug.
-
- + You MAY use RuntimeException for generally unexpected failures.
-
- + It is RECOMMENDED to use RuntimeError also for
- infrastructure failures, e.g. losing SSH connection to SUT.
-
- + You MAY use EnvironmentError and its cublasses instead,
- if the distinction is informative for callers.
-
- + It is RECOMMENDED to use AssertionError when SUT is at fault.
-
- + For each class (e.g. exception) it is RECOMMENDED to implement __repr__()
- which SHALL return a string usable as a constructor call
- (including repr()ed arguments).
- When logging, you SHOULD log the repr form, unless the internal structure
- of the object in question would likely result in too long output.
- This is helpful for debugging.
-
- + For composing and formatting strings, you SHOULD use .format()
- with named arguments.
- Example: "repr() of name: {name!r}".format(name=name)
-
-Bash scripts and libraries
-~~~~~~~~~~~~~~~~~~~~~~~~~~
-
-TODO: Link or copy the bash_code_style.rst document here.