diff options
author | Juraj Linkeš <juraj.linkes@pantheon.tech> | 2024-02-08 13:10:30 +0100 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2024-02-16 06:36:26 +0000 |
commit | 144e2057d8e27a9debb18ed8c0a59065fb27bace (patch) | |
tree | b57fdfec99003a8fa9476c2b5835efe32e27c7da /docs | |
parent | 5ac5ff150deaf930ae120a7f48cc2627508452ed (diff) |
feat(device): add cx6 to 1n-alt ansible
Also update 1n-alt hardware with info from dmidecode and port names to
match the rules in Testbed Naming Convention.
Change-Id: Ib654adaec5667f0e79a3cb86edfbf4578f5c3d5f
Signed-off-by: Juraj Linkeš <juraj.linkes@pantheon.tech>
Diffstat (limited to 'docs')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 68 |
1 files changed, 32 insertions, 36 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index d157d291c9..da71124078 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -162,7 +162,7 @@ one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology Used for FD.io performance tests. -## Tesdtbed Naming Convention +## Testbed Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: @@ -430,12 +430,12 @@ FD.io CSIT lab contains following server types: - IPMI and host management ports. - NIC ports connected into 1-node topologies. - Main HW configuration: - - Chassis: Gigabyte R152-P30-00 1U + - Chassis: Gigabyte E252-P30-00 2U - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - - RAM Memory: 16* 32GB DDR4-3200MT/s - - Disks: 2* 960GB SSD Samsung U.2 NVMe PM9A3 + - Processors: 1* Ampere(R) Altra(R) M128-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41 (Arm), Variant 0x3, Architecture 0xf, Part 0xd0c (neoverse-n1), Revision 0x1 + - RAM Memory: 32* 32GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM9A3 - NICs configuration: - Numa0: - PCIe Slot0 0000:01:00.xx: XL710-QDA2-2p40GE Intel. @@ -821,32 +821,32 @@ FD.io CSIT lab contains following server types: - IPMI IP: 10.30.50.70 - Host IP: 10.30.51.70 - portnames: - - s70-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s70-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s70-t13-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s70-t13-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s70-t13-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s70-t13-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. - s70-t13-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. - s70-t13-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. - s70-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s70-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s70-t13-sut1-c4/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. - - s70-t13-sut1-c4/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. - - s70-t13-sut1-c5/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s70-t13-sut1-c5/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. + - s70-t13-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s70-t13-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. - SUT [Server-Type-E25]: - testbedname: testbed14 - hostname: s71-t14-sut1 - IPMI IP: 10.30.50.71 - Host IP: 10.30.51.71 - portnames: - - s71-t14-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s71-t14-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s71-t14-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s71-t14-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s71-t14-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s71-t14-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. - s71-t14-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. - s71-t14-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. - s71-t14-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s71-t14-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s71-t14-sut1-c4/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. - - s71-t14-sut1-c4/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. - - s71-t14-sut1-c5/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s71-t14-sut1-c5/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. + - s71-t14-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s71-t14-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. ``` ### 1-Node-SapphireRapids (1n-spr) @@ -1671,31 +1671,27 @@ FD.io CSIT lab contains following server types: ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s70-t13-sut1-c1/p1 - s70-t13-sut1-c2/p1. + - s70-t13-sut1-c0/p1 - s70-t13-sut1-c3/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s70-t13-sut1-c1/p2 - s70-t13-sut1-c2/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s70-t13-sut1-c3/p1 - s70-t13-sut1-c4/p1. + - s70-t13-sut1-c0/p2 - s70-t13-sut1-c3/p2. + - ring3 100GE-ports ConnectX6-2p100GE on SUTs: + - s70-t13-sut1-c1/p1 - s70-t13-sut1-c1/p2. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s70-t13-sut1-c3/p2 - s70-t13-sut1-c4/p2. - - ring5 100GE-ports ConnectX6-2p100GE on SUTs: - - s70-t13-sut1-c5/p1 - s70-t13-sut1-c6/p1. - - ring6 100GE-ports ConnectX6-2p100GE on SUTs: - - s70-t13-sut1-c5/p2 - s70-t13-sut1-c6/p2. + - s70-t13-sut1-c2/p1 - s70-t13-sut1-c5/p1. + - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s70-t13-sut1-c2/p2 - s70-t13-sut1-c5/p2. - testbed14: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s71-t14-sut1-c1/p1 - s71-t14-sut1-c2/p1. + - s71-t14-sut1-c0/p1 - s71-t14-sut1-c3/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s71-t14-sut1-c1/p2 - s71-t14-sut1-c2/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s71-t14-sut1-c3/p1 - s71-t14-sut1-c4/p1. + - s71-t14-sut1-c0/p2 - s71-t14-sut1-c3/p2. + - ring3 100GE-ports ConnectX6-2p100GE on SUTs: + - s71-t14-sut1-c1/p1 - s71-t14-sut1-c1/p2. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s71-t14-sut1-c3/p2 - s71-t14-sut1-c4/p2. - - ring5 100GE-ports ConnectX6-2p100GE on SUTs: - - s71-t14-sut1-c5/p1 - s71-t14-sut1-c6/p1. - - ring6 100GE-ports ConnectX6-2p100GE on SUTs: - - s71-t14-sut1-c5/p2 - s71-t14-sut1-c6/p2. + - s71-t14-sut1-c2/p1 - s71-t14-sut1-c5/p1. + - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s71-t14-sut1-c2/p2 - s71-t14-sut1-c5/p2. ``` ### 1-Node-SapphireRapids (1n-spr) |