diff options
author | Maciek Konstantynowicz <mkonstan@cisco.com> | 2020-08-05 14:53:58 +0100 |
---|---|---|
committer | Peter Mikus <pmikus@cisco.com> | 2020-09-18 09:06:59 +0000 |
commit | f0112cf9c44b96e7a0d79ea89912da1ac4d8f4d3 (patch) | |
tree | 90110b0187beefca688a63411f9f2fb1148cf28e /docs | |
parent | ee1c6ce7dd157e141b1911dd1332aac754b0ad8f (diff) |
Added amd 2n-zen2 testbed specification
Change-Id: I429c64f89d1c93945da375072f6f9cb702fa687f
Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs')
-rw-r--r-- | docs/lab/testbed_specifications.md | 145 |
1 files changed, 118 insertions, 27 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 703ebb1427..d636a691dc 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -10,6 +10,7 @@ 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) + 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) @@ -27,11 +28,12 @@ 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip) - 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup) + 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup) + 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup]) 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod) 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) @@ -44,7 +46,8 @@ 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) - 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup) + 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) + 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup]) 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod) 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) @@ -68,22 +71,23 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb - 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 - 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 - 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 - 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 - 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 - 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 - 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 - 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 - 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 -10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 -11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 -12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 -13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 -14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 - Totals: 22 35 18 12 19 1 2 3 1 2 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2 + 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 + 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 + 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 0 +10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 +11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 +12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 0 0 +13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 0 0 +14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 +15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 + Totals: 22 35 18 12 19 1 2 3 1 2 2 7 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -133,6 +137,13 @@ one TG (Server-Type-C3) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 2-Node-Zen2 EPYC AMD (2n-zn2) + +Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and +one TG (Server-Type-D2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one @@ -292,6 +303,8 @@ n/a | s21-t34-sut2 10.30.55.21 | s36-t28-tg1 10.30.55.22 | s37-t29-sut1 10.30.55.23 | s38-t29-tg1 +10.30.55.24 | s60-t210-sut1 +10.30.55.25 | s61-t210-tg1 10.30.55.255 | Broadcast ### Management VLAN IP Addresses @@ -357,9 +370,9 @@ Name | Comment 10.30.51.61 | s25-t25-sut1 10.30.51.62 | s26-t25-tg1 10.30.51.65 | s52-nomad -10.30.51.66 | s51-nomad (out of order) +10.30.51.66 | s51-nomad 10.30.51.67 | s49-nomad -10.30.51.68 | s50-nomad (out of order) +10.30.51.68 | s50-nomad 10.30.51.69 | s27-t13-sut1 10.30.51.70-10.30.51.105 | FREE 10.30.51.106-10.30.51.180 | FREE @@ -381,6 +394,8 @@ Name | Comment 10.32.8.21 | s36-t28-tg1 10.32.8.22 | s37-t29-sut1 10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 10.32.8.255 | Broadcast ## Server Specifications @@ -613,7 +628,6 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports - 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: @@ -634,7 +648,6 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. - 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: @@ -651,7 +664,6 @@ FD.io CSIT lab contains following server types: - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. @@ -672,12 +684,10 @@ FD.io CSIT lab contains following server types: - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. - 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: @@ -694,6 +704,36 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. +15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: x710-4p10GE Intel. + - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. +16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot2 41:00.xx: x710-4p10GE Intel. + - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. ``` ### Naming Convention @@ -771,7 +811,7 @@ connectivity and wiring across defined CSIT testbeds: - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. ``` -#### 1-Node-Cascadelake Servers (1n-clx) SETUP +#### 1-Node-Cascadelake Servers (1n-clx) PROD ``` - SUT [Server-Type-C1]: @@ -1040,6 +1080,39 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` +#### 2-Node-Zen2 Servers (2n-zn2) SETUP + +``` +- SUT [Server-Type-D1]: + - testbedname: testbed210. + - hostname: s60-t210-sut1. + - IPMI IP: 10.30.55.24 + - Host IP: 10.32.8.24 + - portnames: + - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. + - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. + - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. + - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. + - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. + - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-D2]: + - testbedname: testbed210. + - hostname: s61-t210-tg1. + - IPMI IP: 10.30.55.25 + - Host IP: 10.32.8.25 + - portnames: + - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. + - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. + - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. +``` + #### 3-Node-Haswell Servers (3n-hsw) PROD ``` @@ -1530,7 +1603,7 @@ To be completed. - t25-tg1-p4 to t25-sut1-c2/p4. ``` -#### 2-Node-Cascadelake Wiring (2n-clx) SETUP +#### 2-Node-Cascadelake Wiring (2n-clx) PROD ``` - testbed27: @@ -1574,6 +1647,24 @@ To be completed. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. ``` +#### 2-Node-Zen2 Wiring (2n-zen2) SETUP + +``` +- testbed210: + - ring1 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. + - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. + - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. + - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. + - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. +``` + #### 3-Node-Haswell Wiring (3n-hsw) PROD ``` |