diff options
author | pmikus <peter.mikus@protonmail.ch> | 2023-02-23 10:29:12 +0000 |
---|---|---|
committer | pmikus <peter.mikus@protonmail.ch> | 2023-02-23 10:29:12 +0000 |
commit | 5e7c4ced1ac46f93c918d070b19ad330294ad269 (patch) | |
tree | c6de1d8b7e3f52d6862f038be9513f873211e99e /docs | |
parent | 8465c1bbd377b3d7568d70f33ec6d5c0ec177168 (diff) |
feat(docs): Add SPR wiring
Signed-off-by: pmikus <peter.mikus@protonmail.ch>
Change-Id: I6dd06e66ecf790130d7ed9da792068d239ea02db
Diffstat (limited to 'docs')
-rw-r--r-- | docs/lab/testbed_specifications.md | 91 |
1 files changed, 82 insertions, 9 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 1c2d912979..cade63a6f5 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -219,7 +219,7 @@ To access these hosts, VPN connection is required. FD.io CSIT lab contains following server types: ``` 1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - - Quantity: --- + - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - Main HW configuration: @@ -1408,8 +1408,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-H2]: - testbedname: testbed21. - hostname: s53-t21-tg1. - - IPMI IP: 10.30.51.53 - - Host IP: 10.30.50.53 + - IPMI IP: 10.30.50.53 + - Host IP: 10.30.51.53 - portnames: - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. @@ -1442,8 +1442,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-H4]: - testbedname: testbed22. - hostname: s55-t22-tg1. - - IPMI IP: 10.30.51.55 - - Host IP: 10.30.50.55 + - IPMI IP: 10.30.50.55 + - Host IP: 10.30.51.55 - portnames: - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. @@ -1468,8 +1468,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-H6]: - testbedname: testbed23. - hostname: s57-t23-tg1. - - IPMI IP: 10.30.51.57 - - Host IP: 10.30.50.57 + - IPMI IP: 10.30.50.57 + - Host IP: 10.30.51.57 - portnames: - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. @@ -1483,6 +1483,38 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-H5]: + - testbedname: testbed24. + - hostname: s58-t24-sut1. + - IPMI IP: 10.30.50.58 + - Host IP: 10.30.51.58 + - portnames: + - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H6]: + - testbedname: testbed24. + - hostname: s59-t24-tg1. + - IPMI IP: 10.30.50.59 + - Host IP: 10.30.51.59 + - portnames: + - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` ### Per Testbed Wiring @@ -1778,7 +1810,7 @@ To be completed. ``` - testbed39: - - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG: + - ring1 25GE-ports e810-XXVDA4-4p25GE: - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. @@ -1790,5 +1822,46 @@ To be completed. #### 2-Node-SapphireRapids Wiring (2n-spr) PROD ``` -TBD +- testbed21: + - ring1 200GE-ports ConnectX7-2p200GE: + - ?? + - ?? + - ?? +- testbed22: + - ring1 100GE-ports e810-2CQDA2-2p100GE: + - s53-t21-tg1-c2/p1 to s54-t22-sut1-c2/p2. + - s54-t22-sut1-c2/p1 to s54-t22-sut1-c7/p2. + - s54-t22-sut1-c7/p1 to s55-t22-tg1-c2/p2. +- testbed23: + - ring1 200GE-ports ConnectX7-2p200GE: + - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1. + - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2. + - ring2 100GE-ports e810-2CQDA2-2p100GE: + - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. + - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. + - ring3 25GE-ports e810-XXVDA4-2p25GE: + - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. + - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. + - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. + - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4. + - ring4 200GE-ports ConnectX7-2p200GE: + - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2. + - ring5 100GE-ports e810-2CQDA2-2p100GE: + - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2. +- testbed24: + - ring1 200GE-ports ConnectX7-2p200GE: + - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1. + - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2. + - ring2 100GE-ports e810-2CQDA2-2p100GE: + - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. + - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. + - ring3 25GE-ports e810-XXVDA4-2p25GE: + - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. + - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. + - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. + - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4. + - ring4 200GE-ports ConnectX7-2p200GE: + - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. + - ring5 100GE-ports e810-2CQDA2-2p100GE: + - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. ```
\ No newline at end of file |