diff options
author | Tibor Frank <tifrank@cisco.com> | 2017-04-04 10:06:00 +0200 |
---|---|---|
committer | Tibor Frank <tifrank@cisco.com> | 2017-06-05 07:40:28 +0200 |
commit | b92b5be7d4bbbf523812f774bb2e539ab2081cf6 (patch) | |
tree | 61d967364e6eb9952616434b913648742e70fbc9 /tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot | |
parent | 78e999f1203dc8b7c29c24b0178bb8c23edf4c52 (diff) |
CSIT-524: Traffic generator using python profiles
Profile name structure:
[trex|ixia]-[sl|sf]-[topo]-[packet structure]-[scale]
- Traffic generator - T-rex (trex) or Ixia (ixia)
- Stateless (sl) or statefull (sf)
- Topology - 2-node topology (2n) or 3-node topology (3n)
- Packet structure - eth | ip4/6 | udp
- Scale - e.g. ip4dst1, ip6dst10000, 4000u15p
Traffic types changed to stream profiles:
- From: 2-node-bridge
To: trex-sl-2n-ethip4-ip4src253
- From: 3-node-bridge
To: trex-sl-3n-ethip4-ip4src254
- From: 3-node-IPv4-dst-1000000
To: trex-sl-3n-ethip4-ip4dst1000000
- From: 3-node-IPv4-dst-100000
To: trex-sl-3n-ethip4-ip4dst100000
- From: 3-node-IPv4-dst-10000
To: trex-sl-3n-ethip4-ip4dst10000
- From: 3-node-IPv4-dst-1000
To: trex-sl-3n-ethip4-ip4dst1000
- From: 3-node-IPv4-dst-100
To: trex-sl-3n-ethip4-ip4dst100
- From: 3-node-IPv4-dst-1
To: trex-sl-3n-ethip4-ip4dst1
- From: 3-node-IPv4
To: trex-sl-3n-ethip4-ip4src253
- From: 3-node-IPv6-dst-1000000
To: trex-sl-3n-ethip6-ip6dst1000000
- From: 3-node-IPv6-dst-100000
To: trex-sl-3n-ethip6-ip6dst100000
- From: 3-node-IPv6-dst-10000
To: trex-sl-3n-ethip6-ip6dst10000
- From: 3-node-IPv6
To: trex-sl-3n-ethip6-ip6src253
- From: 3-node-xconnect
To: trex-sl-3n-ethip4-ip4src254
- From: 3-node-IPv4-SNAT-1000u-15p
To: trex-sl-3n-ethip4udp-1000u15p
- From: 3-node-IPv4-SNAT-100u-15p
To: trex-sl-3n-ethip4udp-100u15p
- From: 3-node-IPv4-SNAT-10u-15p
To: trex-sl-3n-ethip4udp-10u15p
- From: 3-node-IPv4-SNAT-1u-15p
To: trex-sl-3n-ethip4udp-1u15p
- From: 3-node-IPv4-SNAT-1u-1p
To: trex-sl-3n-ethip4udp-1u1p
- From: 3-node-IPv4-SNAT-2000u-15p
To: trex-sl-3n-ethip4udp-2000u15p
- From: 3-node-IPv4-SNAT-4000u-15p
To: trex-sl-3n-ethip4udp-4000u15p
Change-Id: If6a3cf204c93ff9f2cdccc5fd395e26b05483b58
Signed-off-by: Tibor Frank <tifrank@cisco.com>
Diffstat (limited to 'tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot')
-rw-r--r-- | tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot | 447 |
1 files changed, 211 insertions, 236 deletions
diff --git a/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot b/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot index 58963a59d9..3bfcf9044f 100644 --- a/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot +++ b/tests/perf/10ge2p1x520-ethip4-ip4base-eth-2vhost-1vm-ndrpdrdisc.robot @@ -24,7 +24,7 @@ | ... | Test Setup | Performance test setup | Test Teardown | Performance test with vhost and VM with dpdk-testpmd teardown -| ... | ${min_rate}pps | ${framesize} | 3-node-IPv4 +| ... | ${min_rate}pps | ${framesize} | ${traffic_profile} | ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs} | ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs} | ... @@ -56,12 +56,14 @@ | ... | *[Ref] Applicable standard specifications:* RFC2544. *** Variables *** -#X520-DA2 bandwidth limit +# X520-DA2 bandwidth limit | ${s_limit} | ${10000000000} | ${sock1}= | /tmp/sock-1 | ${sock2}= | /tmp/sock-2 | ${fib_table_1}= | 100 | ${fib_table_2}= | 101 +# Traffic profile: +| ${traffic_profile} | trex-sl-3n-ethip4-ip4src253 *** Test Cases *** | tc01-64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc @@ -79,23 +81,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc02-64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -112,25 +113,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc03-1518B-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -147,23 +146,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc04-1518B-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -180,25 +178,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc05-IMIX-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -216,23 +212,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc06-IMIX-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -250,25 +245,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc07-64B-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -285,23 +278,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc08-64B-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -318,25 +310,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc09-1518B-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -353,23 +343,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc10-1518B-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -386,25 +375,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc11-IMIX-2t2c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -422,23 +409,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc12-IMIX-2t2c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -456,25 +442,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc13-64B-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -491,23 +475,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc14-64B-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -524,25 +507,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc15-1518B-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -559,23 +540,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc16-1518B-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -592,25 +572,23 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} | tc17-IMIX-4t4c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | | [Documentation] @@ -628,23 +606,22 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find NDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} | tc18-IMIX-4t4c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | | [Documentation] @@ -662,22 +639,20 @@ | | ${dut1_vm_refs}= | Create Dictionary | | ${dut2_vm_refs}= | Create Dictionary | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology -| | ... | ${sock1} | ${sock2} +| | And Add PCI devices to DUTs from 3-node single link topology +| | And Add No Multi Seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When IPv4 forwarding with Vhost initialized in a 3-node circular topology +| | ... | ${sock1} | ${sock2} | | ${vm1}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} -| | ... | ${dut1_vif2_mac} +| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 | ${dut1_vif1_mac} +| | ... | ${dut1_vif2_mac} | | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} | | ${vm2}= | And Guest VM with dpdk-testpmd-mac connected via vhost-user is setup -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} -| | ... | ${dut2_vif2_mac} +| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 | ${dut2_vif1_mac} +| | ... | ${dut2_vif2_mac} | | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} | | Then Find PDR using binary search and pps | ${framesize} | ${binary_min} -| | ... | ${binary_max} | 3-node-IPv4 -| | ... | ${min_rate} | ${max_rate} -| | ... | ${threshold} -| | ... | ${perf_pdr_loss_acceptance} -| | ... | ${perf_pdr_loss_acceptance_type} +| | ... | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} |