aboutsummaryrefslogtreecommitdiffstats
path: root/tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot
diff options
context:
space:
mode:
authorTibor Frank <tifrank@cisco.com>2017-06-20 13:57:08 +0200
committerTibor Frank <tifrank@cisco.com>2017-06-29 12:17:28 +0000
commit6721e7f09aa95bff6622068332a3f56afad9c87b (patch)
tree37ef7f40e53f740a62830ab46142aa87342dc56b /tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot
parent859157b5db45927c7b4bb0b2d575e68805777a86 (diff)
CSIT-687: Directory structure reorganization
Change-Id: I772c9e214be2461adf58124998d272e7d795220f Signed-off-by: Tibor Frank <tifrank@cisco.com> Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot')
-rw-r--r--tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot186
1 files changed, 0 insertions, 186 deletions
diff --git a/tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot b/tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot
deleted file mode 100644
index 0c7cd0d2a7..0000000000
--- a/tests/perf/10ge2p1x520-ethip4vxlan-l2xcbase-pdrchk.robot
+++ /dev/null
@@ -1,186 +0,0 @@
-# Copyright (c) 2017 Cisco and/or its affiliates.
-# Licensed under the Apache License, Version 2.0 (the "License");
-# you may not use this file except in compliance with the License.
-# You may obtain a copy of the License at:
-#
-# http://www.apache.org/licenses/LICENSE-2.0
-#
-# Unless required by applicable law or agreed to in writing, software
-# distributed under the License is distributed on an "AS IS" BASIS,
-# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
-# See the License for the specific language governing permissions and
-# limitations under the License.
-
-*** Settings ***
-| Resource | resources/libraries/robot/performance_setup.robot
-| ...
-| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PDRCHK
-| ... | NIC_Intel-X520-DA2 | L2XCFWD | ENCAP | VXLAN | L2OVRLAY | IP4UNRLAY
-| ...
-| Suite Setup | Set up 3-node performance topology with DUT's NIC model
-| ... | L2 | Intel-X520-DA2
-| Suite Teardown | Tear down 3-node performance topology
-| ...
-| Test Setup | Set up performance test
-| Test Teardown | Tear down performance pdrchk test
-| ...
-| Documentation | *Reference PDR throughput L2XC with VXLANoIPv4 verify test\
-| ... | cases*
-| ...
-| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology
-| ... | with single links between nodes.
-| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 cross-connect on TG-DUTn.
-| ... | Eth-IPv4-VXLAN-Eth-IPv4 is applied on link between DUT1 and DUT2.
-| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross-
-| ... | connect. VXLAN tunnels are configured between L2XCs on DUT1 and DUT2.
-| ... | DUT1 and DUT2 tested with 2p10GE NIC X520 Niantic by Intel.
-| ... | *[Ver] TG verification:* In short performance tests, TG verifies
-| ... | DUTs' throughput at ref-PDR (reference Non Drop Rate) with zero packet
-| ... | loss tolerance. Ref-PDR value is periodically updated acording to
-| ... | formula: ref-PDR = 0.9x PDR, where PDR is found in RFC2544 long
-| ... | performance tests for the same DUT configuration. Test packets are
-| ... | generated by TG on links to DUTs. TG traffic profile contains two L3
-| ... | flow-groups (flow-group per direction, 254 flows per flow-group) with
-| ... | all packets containing Ethernet header, IPv4 header with IP protocol=61
-| ... | and generated payload. MAC addresses are matching MAC addresses of the
-| ... | TG node interfaces.
-| ... | *[Ref] Applicable standard specifications:* RFC2544, RFC7348.
-
-*** Variables ***
-| ${vxlan_overhead} | ${50}
-# Traffic profile:
-| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254
-
-*** Keywords ***
-| Check PDR for L2 xconnect with VXLAN over IPv4
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC config with ${wt} thread, ${wt} phy core,\
-| | ... | ${rxq} receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for ${framesize} Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Arguments] | ${framesize} | ${rate} | ${wt} | ${rxq}
-| | ...
-| | # Test Variables required for test and test teardown
-| | Set Test Variable | ${framesize}
-| | Set Test Variable | ${rate}
-| | ${get_framesize}= | Get Frame Size | ${framesize}
-| | ...
-| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
-| | And Add PCI devices to DUTs in 3-node single link topology
-| | And Run Keyword If | ${get_framesize} < ${1522}
-| | ... | Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | And Initialize L2 xconnect with VXLANoIPv4 in 3-node circular topology
-| | Then Traffic should pass with partial loss | ${perf_trial_duration}
-| | ... | ${rate} | ${framesize} | ${traffic_profile}
-| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
-
-*** Test Cases ***
-| tc01-64B-1t1c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC config with 1 thread, 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 64 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 64B | 1T1C | STHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${64 + ${vxlan_overhead}} | rate=2.0mpps | wt=1 | rxq=1
-
-| tc02-1518B-1t1c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC config with 1 thread, 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 1518 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 1518B | 1T1C | STHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${1518 + ${vxlan_overhead}} | rate=500000pps | wt=1 | rxq=1
-
-| tc03-9000B-1t1c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC config with 1 thread, 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 9000B | 1T1C | STHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${9000 + ${vxlan_overhead}} | rate=100000pps | wt=1 | rxq=1
-
-| tc04-64B-2t2c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 64 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 64B | 2T2C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${64 + ${vxlan_overhead}} | rate=5.0mpps | wt=2 | rxq=1
-
-| tc05-1518B-2t2c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 1518 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 1518B | 2T2C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${1518 + ${vxlan_overhead}} | rate=500000pps | wt=2 | rxq=1
-
-| tc06-9000B-2t2c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 9000B | 2T2C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${9000 + ${vxlan_overhead}} | rate=100000pps | wt=2 | rxq=1
-
-| tc07-64B-4t4c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy cores,\
-| | ... | 2 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 64 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 64B | 4T4C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${64 + ${vxlan_overhead}} | rate=6.5mpps | wt=4 | rxq=2
-
-| tc08-1518B-4t4c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy cores,\
-| | ... | 2 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 1518 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 1518B | 4T4C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${1518 + ${vxlan_overhead}} | rate=500000pps | wt=4 | rxq=2
-
-| tc09-9000B-4t4c-ethip4vxlan-l2xcbase-pdrchk
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy cores,\
-| | ... | 2 receive queue per NIC port.
-| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test at 2x ${rate}.
-| | ...
-| | [Tags] | 9000B | 4T4C | MTHREAD
-| | ...
-| | [Template] | Check PDR for L2 xconnect with VXLAN over IPv4
-| | framesize=${9000 + ${vxlan_overhead}} | rate=100000pps | wt=4 | rxq=2