diff options
author | pmikus <pmikus@cisco.com> | 2016-11-16 16:45:05 +0100 |
---|---|---|
committer | Peter Mikus <pmikus@cisco.com> | 2017-01-10 11:42:01 +0000 |
commit | e3ed9257cd7ef50b44eca72ef7d9ae6c7c792647 (patch) | |
tree | b5234556896a1860c172c2792a55c7d402daa36a /tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot | |
parent | 2671e2616aab7a0bfec7a3501d53ccd72e12d668 (diff) |
CSIT-469 Rename performance suites
Rename performance suites and add more TAGS
Change-Id: I6a5251bb6e380fe2a47a6ec1c1aeb4a9f70c5ce3
Signed-off-by: pmikus <pmikus@cisco.com>
Diffstat (limited to 'tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot')
-rw-r--r-- | tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot | 283 |
1 files changed, 0 insertions, 283 deletions
diff --git a/tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot b/tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot deleted file mode 100644 index 5bbc018d68..0000000000 --- a/tests/perf/Short_Xconnect_Dot1ad_Intel-X520-DA2.robot +++ /dev/null @@ -1,283 +0,0 @@ -# Copyright (c) 2016 Cisco and/or its affiliates. -# Licensed under the Apache License, Version 2.0 (the "License"); -# you may not use this file except in compliance with the License. -# You may obtain a copy of the License at: -# -# http://www.apache.org/licenses/LICENSE-2.0 -# -# Unless required by applicable law or agreed to in writing, software -# distributed under the License is distributed on an "AS IS" BASIS, -# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. -# See the License for the specific language governing permissions and -# limitations under the License. - -*** Settings *** -| Resource | resources/libraries/robot/performance.robot -| Resource | resources/libraries/robot/tagging.robot -| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PERFTEST_SHORT -| ... | NIC_Intel-X520-DA2 -| Suite Setup | 3-node Performance Suite Setup with DUT's NIC model -| ... | L2 | Intel-X520-DA2 -| Suite Teardown | 3-node Performance Suite Teardown -| Test Setup | Setup all DUTs before test -| Test Teardown | Run Keywords | Remove startup configuration of VPP from all DUTs -| ... | AND | Show vpp trace dump on all DUTs -| Documentation | *Reference NDR throughput L2XC with 802.1ad verify test cases* -| ... -| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology -| ... | with single links between nodes. -| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 xconnect. -| ... | 802.1ad tagging is applied on link between DUT1 and DUT2 with inner 4B -| ... | vlan tag (id=100) and outer 4B vlan tag (id=200). -| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross- -| ... | connect. DUT1 and DUT2 tested with 2p10GE NIC X520 Niantic by Intel. -| ... | *[Ver] TG verification:* In short performance tests, TG verifies -| ... | DUTs' throughput at ref-NDR (reference Non Drop Rate) with zero packet -| ... | loss tolerance. Ref-NDR value is periodically updated acording to -| ... | formula: ref-NDR = 0.9x NDR, where NDR is found in RFC2544 long -| ... | performance tests for the same DUT configuration. Test packets are -| ... | generated by TG on links to DUTs. TG traffic profile contains two L3 -| ... | flow-groups (flow-group per direction, 253 flows per flow-group) with -| ... | all packets containing Ethernet header, IPv4 header with IP protocol=61 -| ... | and static payload. MAC addresses are matching MAC addresses of the -| ... | TG node interfaces. -| ... | *[Ref] Applicable standard specifications:* RFC2544. - -*** Variables *** -| ${subid}= | 10 -| ${outer_vlan_id}= | 100 -| ${inner_vlan_id}= | 200 -| ${type_subif}= | two_tags -| ${tag_rewrite}= | pop-2 - -*** Test Cases *** -| TC01: Verify 64B ref-NDR at 2x 2.9Mpps - DUT L2XC with 802.1ad - 1thread 1core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR -| | ${framesize}= | Set Variable | 64 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 2.9mpps -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC02: Verify 1514B ref-NDR at 2x 810.635kpps - DUT L2XC with 802.1ad - 1thread 1core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR -| | ${framesize}= | Set Variable | 1514 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 810635pps -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC03: Verify 9000B ref-NDR at 2x 138.458kpps - DUT L2XC with 802.1ad - 1thread 1core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR -| | ${framesize}= | Set Variable | 9000 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 138458pps -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC04: Verify 64B ref-NDR at 2x 7Mpps - DUT L2XC with 802.1ad - 2thread 2core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 64 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 7.0mpps -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC05: Verify 1514B ref-NDR at 2x 810.635kpps - DUT L2XC with 802.1ad - 2thread 2core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 1514 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 810635pps -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC06: Verify 9000B ref-NDR at 2x 138.458kpps - DUT L2XC with 802.1ad - 2thread 2core 1rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \ -| | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 9000 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 138458pps -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC07: Verify 64B ref-NDR at 2x 8Mpps - DUT L2XC with 802.1ad - 4thread 4core 2rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \ -| | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 64 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 8.0mpps -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC08: Verify 1514B ref-NDR at 2x 810.635kpps - DUT L2XC with 802.1ad - 4thread 4core 2rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \ -| | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 1514 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 810635pps -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect - -| TC09: Verify 9000B ref-NDR at 2x 138.458kpps - DUT L2XC with 802.1ad - 4thread 4core 2rxq -| | [Documentation] -| | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \ -| | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte -| | ... | frames using single trial throughput test. -| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR -| | ${framesize}= | Set Variable | 9000 -| | ${duration}= | Set Variable | 10 -| | ${rate}= | Set Variable | 138458pps -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Apply startup configuration on all VPP DUTs -| | And VPP interfaces in path are up in a 3-node circular topology -| | When VLAN subinterfaces initialized on 3-node topology -| | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid} -| | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif} -| | And L2 tag rewrite method setup on interfaces -| | ... | ${dut1} | ${subif_index_1} | ${dut2} | ${subif_index_2} -| | ... | ${tag_rewrite} -| | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect -| | ... | ${dut1} | ${dut1_if1} | ${subif_index_1} -| | ... | ${dut2} | ${dut2_if2} | ${subif_index_2} -| | Then Traffic should pass with no loss | ${duration} | ${rate} -| | ... | ${framesize} | 3-node-xconnect |