diff options
author | Peter Mikus <pmikus@cisco.com> | 2018-07-10 06:10:41 +0000 |
---|---|---|
committer | Peter Mikus <pmikus@cisco.com> | 2018-07-13 09:11:04 +0000 |
commit | ad71afc5baa8008bd5d4ea26f51a71eefe3fbe62 (patch) | |
tree | 3b1c24ab540b5f57ee4b3592368191bc1f227cc7 /tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot | |
parent | 338b195c0d7274b921eb18944d27ed1b4cb3739f (diff) |
Refactor perf test cases
- Refactor Performance TCs due to changes in Hyperthreading and RXQ allocations.
- Simplify the structure of suite to avoid large refactors in future.
Change-Id: Ifb1b9719391f26745f075a900bd9fb39b6cb809c
Signed-off-by: Peter Mikus <pmikus@cisco.com>
Diffstat (limited to 'tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot')
-rw-r--r-- | tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot | 36 |
1 files changed, 18 insertions, 18 deletions
diff --git a/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot b/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot index 7f5f8d29d3..ba0a51a5b2 100644 --- a/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot +++ b/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip4-ip6base-ndrpdrdisc.robot @@ -66,7 +66,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -96,7 +96,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -127,7 +127,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -157,7 +157,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -188,7 +188,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology @@ -217,7 +217,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 1 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology @@ -247,7 +247,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -277,7 +277,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -308,7 +308,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -338,7 +338,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -369,7 +369,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology @@ -398,7 +398,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 2 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology @@ -428,7 +428,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -458,7 +458,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -489,7 +489,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -519,7 +519,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs @@ -550,7 +550,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology @@ -579,7 +579,7 @@ | | ${binary_min}= | Set Variable | ${min_rate} | | ${binary_max}= | Set Variable | ${max_rate} | | ${threshold}= | Set Variable | ${min_rate} -| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | Given Add worker threads and rxqueues to all DUTs | 4 | | And Add PCI devices to all DUTs | | And Apply startup configuration on all VPP DUTs | | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology |