diff options
author | Jan Gelety <jgelety@cisco.com> | 2017-06-29 09:05:00 +0200 |
---|---|---|
committer | Jan Gelety <jgelety@cisco.com> | 2017-08-01 17:41:27 +0200 |
commit | 0cd7a2d0d4e701ca61421c5de9b4b0460fdfa28a (patch) | |
tree | 2f41ec1781714c573f55123ead98a2bba2733560 /tests/vpp/perf/l2 | |
parent | f67399101f4fa359de7f6e2b325be455d1438ee8 (diff) |
CSIT-699: Add l2bd+dot1q perf tests
Change-Id: I3d8cbb235918331b3c60147f7870a4aa90036748
Signed-off-by: Jan Gelety <jgelety@cisco.com>
Diffstat (limited to 'tests/vpp/perf/l2')
-rw-r--r-- | tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot | 316 |
1 files changed, 316 insertions, 0 deletions
diff --git a/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot b/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot new file mode 100644 index 0000000000..ca241c9f54 --- /dev/null +++ b/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot @@ -0,0 +1,316 @@ +# Copyright (c) 2017 Cisco and/or its affiliates. +# Licensed under the Apache License, Version 2.0 (the "License"); +# you may not use this file except in compliance with the License. +# You may obtain a copy of the License at: +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, +# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. +# See the License for the specific language governing permissions and +# limitations under the License. + +*** Settings *** +| Resource | resources/libraries/robot/performance/performance_setup.robot +| ... +| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC +| ... | NIC_Intel-X520-DA2 | BASE | DOT1Q | L2BDMACLRN +| ... +| Suite Setup | Set up 3-node performance topology with DUT's NIC model +| ... | L2 | Intel-X520-DA2 +| Suite Teardown | Tear down 3-node performance topology +| ... +| Test Setup | Set up performance test +| Test Teardown | Tear down performance discovery test | ${min_rate}pps +| ... | ${framesize} | ${traffic_profile} +| ... +| Documentation | *RFC2544: Packet throughput L2BD test cases with vhost* +| ... +| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology\ +| ... | with single links between nodes. +| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 switching of IPv4.\ +| ... | 802.1q tagging is applied on link between DUT1 and DUT2. +| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 bridge\ +| ... | domain and MAC learning enabled. DUT1 and DUT2 tested with 2p10GE NIC +| ... | X520 Niantic by Intel. +| ... | *[Ver] TG verification:* TG finds and reports throughput NDR (Non Drop\ +| ... | Rate) with zero packet loss tolerance or throughput PDR (Partial Drop\ +| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage\ +| ... | of packets transmitted. NDR and PDR are discovered for different\ +| ... | Ethernet L2 frame sizes using either binary search or linear search\ +| ... | algorithms with configured starting rate and final step that determines\ +| ... | throughput measurement resolution. Test packets are generated by TG on\ +| ... | links to DUTs. TG traffic profile contains two L3 flow-groups\ +| ... | (flow-group per direction, 254 flows per flow-group) with all packets\ +| ... | containing Ethernet header, IPv4 header with IP protocol=61 and static\ +| ... | payload. MAC addresses are matching MAC addresses of the TG node\ +| ... | interfaces. +| ... | *[Ref] Applicable standard specifications:* RFC2544. + +*** Variables *** +| ${subid}= | 10 +| ${tag_rewrite}= | pop-1 +| ${vlan_overhead}= | ${4} +| ${avg_imix_framesize}= | ${357.833} +# X520-DA2 bandwidth limit +| ${s_limit} | ${10000000000} +# Bridge domain IDs +| ${bd_id1}= | 1 +| ${bd_id2}= | 2 +# Traffic profile: +| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254 + +*** Keywords *** +| Discover NDR or PDR for L2 Bridge Domain with VLAN +| | [Arguments] | ${wt} | ${rxq} | ${framesize} | ${min_rate} | ${search_type} +| | ... +| | Set Test Variable | ${framesize} +| | Set Test Variable | ${min_rate} +| | ${get_framesize}= | Set Variable If +| | ... | "${framesize}" == "IMIX_v4_1" | ${avg_imix_framesize} +| | ... | ${framesize} +| | ${max_rate}= | Calculate pps | ${s_limit} +| | ... | ${get_framesize + ${vlan_overhead}} +| | ${binary_min}= | Set Variable | ${min_rate} +| | ${binary_max}= | Set Variable | ${max_rate} +| | ${threshold}= | Set Variable | ${min_rate} +| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Run Keyword If | ${get_framesize} < ${1522} +| | ... | Add no multi seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When Initialize L2 bridge domains with VLAN dot1q sub-interfaces in a 3-node circular topology +| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite} +| | Run Keyword If | '${search_type}' == 'NDR' +| | ... | Find NDR using binary search and pps +| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ELSE IF | '${search_type}' == 'PDR' +| | ... | Find PDR using binary search and pps +| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} +| | ... | ${min_rate} | ${max_rate} | ${threshold} +| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} + +*** Test Cases *** +| tc01-64B-1t1c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps. +| | ... +| | [Tags] | 64B | 1T1C | STHREAD | NDRDISC +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=NDR + +| tc02-64B-1t1c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps, LT=0.5%. +| | ... +| | [Tags] | 64B | 1T1C | STHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=PDR + +| tc03-1518B-1t1c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps. +| | ... +| | [Tags] | 1518B | 1T1C | STHREAD | NDRDISC +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=NDR + +| tc04-1518B-1t1c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps, LT=0.5%. +| | ... +| | [Tags] | 1518B | 1T1C | STHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=PDR + +| tc05-IMIX-1t1c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 1T1C | STHREAD | NDRDISC +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR + +| tc06-IMIX-1t1c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps, LT=0.5%. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 1T1C | STHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=1 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR + +| tc07-64B-2t2c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps. +| | ... +| | [Tags] | 64B | 2T2C | MTHREAD | NDRDISC +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=NDR + +| tc08-64B-2t2c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps, LT=0.5%. +| | ... +| | [Tags] | 64B | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=PDR + +| tc09-1518B-2t2c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps. +| | ... +| | [Tags] | 1518B | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=NDR + +| tc10-1518B-2t2c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps, LT=0.5%. +| | ... +| | [Tags] | 1518B | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=PDR + +| tc11-IMIX-2t2c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR + +| tc12-IMIX-2t2c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\ +| | ... | 1 receive queue per NIC port. +| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=2 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR + +| tc13-64B-4t4c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps. +| | ... +| | [Tags] | 64B | 4T4C | MTHREAD | NDRDISC +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=${64} | min_rate=${100000} | search_type=NDR + +| tc14-64B-4t4c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 100kpps, LT=0.5%. +| | ... +| | [Tags] | 64B | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=${64} | min_rate=${100000} | search_type=PDR + +| tc15-1518B-4t4c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps. +| | ... +| | [Tags] | 1518B | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=${1518} | min_rate=${10000} | search_type=NDR + +| tc16-1518B-4t4c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\ +| | ... | linerate, step 10kpps, LT=0.5%. +| | ... +| | [Tags] | 1518B | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=${1518} | min_rate=${10000} | search_type=PDR + +| tc17-IMIX-4t4c-dot1q-l2bdbasemaclrn-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR + +| tc18-IMIX-4t4c-dot1q-l2bdbasemaclrn-pdrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\ +| | ... | 2 receive queues per NIC port. +| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\ +| | ... | 10GE linerate, step 10kpps, LT=0.5%. +| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B) +| | ... +| | [Tags] | IMIX | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH +| | ... +| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN +| | wt=4 | rxq=2 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR |