diff options
author | Jan Gelety <jgelety@cisco.com> | 2017-07-13 17:06:06 +0200 |
---|---|---|
committer | Jan Gelety <jgelety@cisco.com> | 2017-07-17 10:47:55 +0200 |
commit | b4157d62463fc54621fed74b223fcada4811efd1 (patch) | |
tree | 1d2067efc34a60dcf0c5f7004db6f71b5e8a95ce /tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot | |
parent | d9a08e59581aafe44d446b5bc1ce6ff86b2b173b (diff) |
FIX: remove previous QEMU build when needed to change qsz
Change-Id: I949f8800b45354c205c5a5d36ab2abeeb93409dc
Signed-off-by: Jan Gelety <jgelety@cisco.com>
Diffstat (limited to 'tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot')
-rw-r--r-- | tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot | 212 |
1 files changed, 0 insertions, 212 deletions
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot b/tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot deleted file mode 100644 index bab866795a..0000000000 --- a/tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk.robot +++ /dev/null @@ -1,212 +0,0 @@ -# Copyright (c) 2017 Cisco and/or its affiliates. -# Licensed under the Apache License, Version 2.0 (the "License"); -# you may not use this file except in compliance with the License. -# You may obtain a copy of the License at: -# -# http://www.apache.org/licenses/LICENSE-2.0 -# -# Unless required by applicable law or agreed to in writing, software -# distributed under the License is distributed on an "AS IS" BASIS, -# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. -# See the License for the specific language governing permissions and -# limitations under the License. - -*** Settings *** -| Resource | resources/libraries/robot/performance/performance_setup.robot -| Library | resources.libraries.python.QemuUtils -| ... -| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PDRCHK -| ... | NIC_Intel-X520-DA2 | DOT1Q | L2BDMACLRN | BASE | VHOST | VM -| ... -| Suite Setup | Set up 3-node performance topology with DUT's NIC model -| ... | L2 | Intel-X520-DA2 -| Suite Teardown | Tear down 3-node performance topology -| ... -| Test Setup | Set up performance test -| Test Teardown | Tear down performance pdrchk test with vhost and VM with dpdk-testpmd -| ... | ${rate}pps | ${framesize} | ${traffic_profile} -| ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs} -| ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs} -| ... -| Documentation | *RFC2544: Packet throughput L2BD test cases with vhost* -| ... -| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology -| ... | with single links between nodes. -| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 switching of IPv4. 802.1q -| ... | tagging is applied on link between DUT1 and DUT2. -| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 bridge- -| ... | domain and MAC learning enabled. Qemu Guest is connected to VPP via -| ... | vhost-user interfaces. Guest is running DPDK testpmd interconnecting -| ... | vhost-user interfaces using 5 cores pinned to cpus 5-9 and 2048M -| ... | memory. Testpmd is using socket-mem=1024M (512x2M hugepages), 5 cores -| ... | (1 main core and 4 cores dedicated for io), forwarding mode is set to -| ... | io, rxd/txd=256, burst=64. DUT1, DUT2 are tested with 2p10GE NIC X520 -| ... | Niantic by Intel. -| ... | *[Ver] TG verification:* TG verifies throughput PDR (Partial Drop -| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage -| ... | of packets transmitted. Ref-PDR value is periodically updated acording to -| ... | formula: ref-PDR = 0.9x PDR, where PDR is found in RFC2544 long -| ... | performance tests for the same DUT configuration. Test packets are -| ... | generated by TG on links to DUTs. TG traffic profile contains two L3 -| ... | flow-groups (flow-group per direction, 253 flows per flow-group) with -| ... | all packets containing Ethernet header, IPv4 header with IP protocol=61 -| ... | and static payload. MAC addresses are matching MAC addresses of the -| ... | TG node interfaces. -| ... | *[Ref] Applicable standard specifications:* RFC2544. - -*** Variables *** -| ${subid}= | 10 -| ${tag_rewrite}= | pop-1 -# Socket names -| ${bd_id1}= | 1 -| ${bd_id2}= | 2 -| ${sock1}= | /tmp/sock-1-${bd_id1} -| ${sock2}= | /tmp/sock-1-${bd_id2} -# Traffic profile: -| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254 - -*** Keywords *** -| Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with ${wt} thread, ${wt} phy\ -| | ... | core, ${rxq} receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for ${framesize} Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Arguments] | ${framesize} | ${rate} | ${wt} | ${rxq} -| | ... -| | # Test Variables required for test and test teardown -| | Set Test Variable | ${framesize} -| | Set Test Variable | ${rate} -| | ${get_framesize}= | Get Frame Size | ${framesize} -| | ${dut1_vm_refs}= | Create Dictionary -| | ${dut2_vm_refs}= | Create Dictionary -| | Set Test Variable | ${dut1_vm_refs} -| | Set Test Variable | ${dut2_vm_refs} -| | ... -| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology -| | And Add PCI devices to DUTs in 3-node single link topology -| | And Run Keyword If | ${get_framesize} < ${1522} -| | ... | Add no multi seg to all DUTs -| | And Apply startup configuration on all VPP DUTs -| | When Initialize L2 bridge domains with Vhost-User and VLAN in a 3-node circular topology -| | ... | ${bd_id1} | ${bd_id2} | ${sock1} | ${sock2} | ${subid} -| | ... | ${tag_rewrite} -| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user -| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1 -| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1} -| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user -| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1 -| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2} -| | Then Traffic should pass with partial loss | ${perf_trial_duration} -| | ... | ${rate} | ${framesize} | ${traffic_profile} -| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type} - -*** Test Cases *** -| tc01-64B-1t1c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy\ -| | ... | core, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 64B | 1T1C | STHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${64} | rate=1.2mpps | wt=1 | rxq=1 - -| tc02-1518B-1t1c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy\ -| | ... | core, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 1518B | 1T1C | STHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${1518} | rate=350000pps | wt=1 | rxq=1 - -| tc03-IMIX-1t1c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy\ -| | ... | core, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | IMIX | 1T1C | STHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=IMIX_v4_1 | rate=0.9mpps | wt=1 | rxq=1 - -| tc04-64B-2t2c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy\ -| | ... | cores, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 64B | 2T2C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${64} | rate=2.2mpps | wt=2 | rxq=1 - -| tc05-1518B-2t2c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy\ -| | ... | cores, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 1518B | 2T2C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${1518} | rate=0.6mpps | wt=2 | rxq=1 - -| tc06-IMIX-2t2c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy\ -| | ... | cores, 1 receive queue per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | IMIX | 2T2C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=IMIX_v4_1 | rate=1.5pps | wt=2 | rxq=1 - -| tc07-64B-4t4c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy\ -| | ... | cores, 2 receive queues per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 64B | 4T4C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${64} | rate=3.4mpps | wt=4 | rxq=2 - -| tc08-1518B-4t4c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy\ -| | ... | cores, 2 receive queues per NIC port. -| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | 1518B | 4T4C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=${1518} | rate=0.7mpps | wt=4 | rxq=2 - -| tc09-IMIX-4t4c-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-pdrchk -| | [Documentation] -| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy\ -| | ... | cores, 2 receive queues per NIC port. -| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\ -| | ... | throughput test at 2x ${rate}. -| | ... -| | [Tags] | IMIX | 4T4C | MTHREAD -| | ... -| | [Template] | Check PDR for L2 bridge domain with vhost and VM with dpdk-testpmd -| | framesize=IMIX_v4_1 | rate=2.2mpps | wt=4 | rxq=2 |