diff options
author | Peter Mikus <pmikus@cisco.com> | 2018-03-14 16:59:04 +0100 |
---|---|---|
committer | Peter Mikus <pmikus@cisco.com> | 2018-03-16 13:17:30 +0000 |
commit | fdf235ec30b409daef533c5258e2bfbe506c49f8 (patch) | |
tree | f1b2d3b6c85ee194610433fa9f660c6ac16a306b /tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot | |
parent | 237ac98ad0cca7a24e3f38ec9f8b73c106a8b00a (diff) |
Add vhost and memif MRR suite
Change-Id: Iaded13af82383955c2ff093ddc96e09682d95776
Signed-off-by: Peter Mikus <pmikus@cisco.com>
Diffstat (limited to 'tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot')
-rw-r--r-- | tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot | 197 |
1 files changed, 197 insertions, 0 deletions
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot new file mode 100644 index 0000000000..0417b1f65a --- /dev/null +++ b/tests/vpp/perf/vm_vhost/10ge2p1x520-eth-l2xcbase-eth-4vhostvr1024-2vm-mrr.robot @@ -0,0 +1,197 @@ +# Copyright (c) 2018 Cisco and/or its affiliates. +# Licensed under the Apache License, Version 2.0 (the "License"); +# you may not use this file except in compliance with the License. +# You may obtain a copy of the License at: +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, +# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. +# See the License for the specific language governing permissions and +# limitations under the License. + +*** Settings *** +| Resource | resources/libraries/robot/performance/performance_setup.robot +| Library | resources.libraries.python.QemuUtils +| ... +| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | MRR +| ... | NIC_Intel-X520-DA2 | ETH | L2XCFWD | BASE | VHOST | 2VM | VHOST_1024 +| ... +| Suite Setup | Set up 3-node performance topology with DUT's NIC model +| ... | L2 | Intel-X520-DA2 +| Suite Teardown | Tear down 3-node performance topology +| ... +| Test Setup | Set up performance test +| Test Teardown | Tear down performance mrr test with vhost and VM with dpdk-testpmd +| ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs} +| ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs} +| ... +| Documentation | *Raw results L2XC test cases with vhost* +| ... +| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology +| ... | with single links between nodes. +| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 switching of IPv4. 802.1q +| ... | tagging is applied on link between DUT1 and DUT2. +| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross- +| ... | connects. Qemu Guests are connected to VPP via vhost-user interfaces. +| ... | Guests are running DPDK testpmd interconnecting vhost-user interfaces +| ... | using 5 cores pinned to cpus 6-10 and 11-15 and 2048M memory. Testpmd is +| ... | using socket-mem=1024M (512x2M hugepages), 5 cores (1 main core and 4 +| ... | cores dedicated for io), forwarding mode is set to io, rxd/txd=1024, +| ... | burst=64. DUT1, DUT2 are tested with 2p10GE NIC X520 Niantic by Intel. +| ... | *[Ver] TG verification:* In MaxReceivedRate test TG sends traffic +| ... | at line rate and reports total received/sent packets over trial period. +| ... | Test packets are generated by TG on links to DUTs. TG traffic profile +| ... | contains two L3 flow-groups (flow-group per direction, 254 flows per +| ... | flow-group) with all packets containing Ethernet header, IPv4 header +| ... | with IP protocol=61 and static payload. MAC addresses are matching MAC +| ... | addresses of the TG node interfaces. + +*** Variables *** +#CPU settings +| ${system_cpus}= | ${1} +| ${vpp_cpus}= | ${5} +| ${vm_cpus}= | ${5} +# X520-DA2 bandwidth limit +| ${s_limit}= | ${10000000000} +# Traffic profile: +| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254 + +*** Keywords *** +| Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with ${wt} thread, ${wt} phy\ +| | ... | core, ${rxq} receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Arguments] | ${framesize} | ${wt} | ${rxq} +| | ... +| | # Test Variables required for test and test teardown +| | Set Test Variable | ${framesize} +| | ${get_framesize}= | Get Frame Size | ${framesize} +| | ${max_rate}= | Calculate pps | ${s_limit} | ${get_framesize} +| | ${dut1_vm_refs}= | Create Dictionary +| | ${dut2_vm_refs}= | Create Dictionary +| | Set Test Variable | ${dut1_vm_refs} +| | Set Test Variable | ${dut2_vm_refs} +| | ... +| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Run Keyword If | ${get_framesize} < ${1522} +| | ... | Add no multi seg to all DUTs +| | And Apply startup configuration on all VPP DUTs +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology +| | Then Traffic should pass with maximum rate | ${perf_trial_duration} +| | ... | ${max_rate}pps | ${framesize} | ${traffic_profile} + +*** Test Cases *** +| tc01-64B-1t1c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\ +| | ... | core, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 64B | 1T1C | STHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${64} | wt=1 | rxq=1 + +| tc02-1518B-1t1c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\ +| | ... | core, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 1518B | 1T1C | STHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${1518} | wt=1 | rxq=1 + +| tc03-IMIX-1t1c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\ +| | ... | core, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | IMIX | 1T1C | STHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=IMIX_v4_1 | wt=1 | rxq=1 + +| tc04-64B-2t2c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\ +| | ... | cores, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 64B | 2T2C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${64} | wt=2 | rxq=1 + +| tc05-1518B-2t2c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\ +| | ... | cores, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 1518B | 2T2C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${1518} | wt=2 | rxq=1 + +| tc06-IMIX-2t2c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\ +| | ... | cores, 1 receive queue per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | IMIX | 2T2C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=IMIX_v4_1 | wt=2 | rxq=1 + +| tc07-64B-4t4c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\ +| | ... | cores, 2 receive queues per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 64B | 4T4C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${64} | wt=4 | rxq=2 + +| tc08-1518B-4t4c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\ +| | ... | cores, 2 receive queues per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | 1518B | 4T4C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=${1518} | wt=4 | rxq=2 + +| tc09-IMIX-4t4c-eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc-mrr +| | [Documentation] +| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\ +| | ... | cores, 2 receive queues per NIC port. +| | ... | [Ver] Measure MaxReceivedRate for ${framesize} frames using single\ +| | ... | trial throughput test. +| | ... +| | [Tags] | IMIX | 4T4C | MTHREAD +| | ... +| | [Template] | Check RR for eth-l2xcbase-eth-4vhostvr1024-2vm-ndrdisc +| | framesize=IMIX_v4_1 | wt=4 | rxq=2 |