FIX: Use correct interface type in x710_1lbvpplacp perf tests
Change-Id: I68db0b0441ffc7d9b5e04048688711915ab24726 Signed-off-by: Jan Gelety <jgelety@cisco.com>
Diffstat (limited to 'tests/vpp/perf/vm_vhost')
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-mrr.robot2
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot2
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-mrr.robot2
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot2
4 files changed, 4 insertions, 4 deletions
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-mrr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-mrr.robot
index c3a09badce..561ca1eaa7 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-mrr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-mrr.robot
@@ -21,7 +21,7 @@
| ...
| Suite Setup | Run Keywords
| ... | Set up 3-node performance topology with DUT's NIC model | L2
-| ... | Intel-X520-DA2
+| ... | Intel-X710
| ... | AND | Set up performance test suite with LACP mode link bonding
| ...
| Suite Teardown | Tear down 3-node performance topology
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index 556751a3fd..a883291ce7 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -21,7 +21,7 @@
| ...
| Suite Setup | Run Keywords
| ... | Set up 3-node performance topology with DUT's NIC model | L2
-| ... | Intel-X520-DA2
+| ... | Intel-X710
| ... | AND | Set up performance test suite with LACP mode link bonding
| ...
| Suite Teardown | Tear down 3-node performance topology
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-mrr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-mrr.robot
index 00e2ad0e97..590066c790 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-mrr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-mrr.robot
@@ -21,7 +21,7 @@
| ...
| Suite Setup | Run Keywords
| ... | Set up 3-node performance topology with DUT's NIC model | L2
-| ... | Intel-X520-DA2
+| ... | Intel-X710
| ... | AND | Set up performance test suite with LACP mode link bonding
| ...
| Suite Teardown | Tear down 3-node performance topology
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index 262f587566..e64da50425 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -21,7 +21,7 @@
| ...
| Suite Setup | Run Keywords
| ... | Set up 3-node performance topology with DUT's NIC model | L2
-| ... | Intel-X520-DA2
+| ... | Intel-X710
| ... | AND | Set up performance test suite with LACP mode link bonding
| ...
| Suite Teardown | Tear down 3-node performance topology