aboutsummaryrefslogtreecommitdiffstats
path: root/tests
diff options
context:
space:
mode:
authorJan Gelety <jgelety@cisco.com>2017-06-29 09:05:00 +0200
committerJan Gelety <jgelety@cisco.com>2017-08-01 17:41:27 +0200
commit0cd7a2d0d4e701ca61421c5de9b4b0460fdfa28a (patch)
tree2f41ec1781714c573f55123ead98a2bba2733560 /tests
parentf67399101f4fa359de7f6e2b325be455d1438ee8 (diff)
CSIT-699: Add l2bd+dot1q perf tests
Change-Id: I3d8cbb235918331b3c60147f7870a4aa90036748 Signed-off-by: Jan Gelety <jgelety@cisco.com>
Diffstat (limited to 'tests')
-rw-r--r--tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot316
1 files changed, 316 insertions, 0 deletions
diff --git a/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot b/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot
new file mode 100644
index 0000000000..ca241c9f54
--- /dev/null
+++ b/tests/vpp/perf/l2/10ge2p1x520-dot1q-l2bdbasemaclrn-ndrpdrdisc.robot
@@ -0,0 +1,316 @@
+# Copyright (c) 2017 Cisco and/or its affiliates.
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at:
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+*** Settings ***
+| Resource | resources/libraries/robot/performance/performance_setup.robot
+| ...
+| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC
+| ... | NIC_Intel-X520-DA2 | BASE | DOT1Q | L2BDMACLRN
+| ...
+| Suite Setup | Set up 3-node performance topology with DUT's NIC model
+| ... | L2 | Intel-X520-DA2
+| Suite Teardown | Tear down 3-node performance topology
+| ...
+| Test Setup | Set up performance test
+| Test Teardown | Tear down performance discovery test | ${min_rate}pps
+| ... | ${framesize} | ${traffic_profile}
+| ...
+| Documentation | *RFC2544: Packet throughput L2BD test cases with vhost*
+| ...
+| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology\
+| ... | with single links between nodes.
+| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 switching of IPv4.\
+| ... | 802.1q tagging is applied on link between DUT1 and DUT2.
+| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 bridge\
+| ... | domain and MAC learning enabled. DUT1 and DUT2 tested with 2p10GE NIC
+| ... | X520 Niantic by Intel.
+| ... | *[Ver] TG verification:* TG finds and reports throughput NDR (Non Drop\
+| ... | Rate) with zero packet loss tolerance or throughput PDR (Partial Drop\
+| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage\
+| ... | of packets transmitted. NDR and PDR are discovered for different\
+| ... | Ethernet L2 frame sizes using either binary search or linear search\
+| ... | algorithms with configured starting rate and final step that determines\
+| ... | throughput measurement resolution. Test packets are generated by TG on\
+| ... | links to DUTs. TG traffic profile contains two L3 flow-groups\
+| ... | (flow-group per direction, 254 flows per flow-group) with all packets\
+| ... | containing Ethernet header, IPv4 header with IP protocol=61 and static\
+| ... | payload. MAC addresses are matching MAC addresses of the TG node\
+| ... | interfaces.
+| ... | *[Ref] Applicable standard specifications:* RFC2544.
+
+*** Variables ***
+| ${subid}= | 10
+| ${tag_rewrite}= | pop-1
+| ${vlan_overhead}= | ${4}
+| ${avg_imix_framesize}= | ${357.833}
+# X520-DA2 bandwidth limit
+| ${s_limit} | ${10000000000}
+# Bridge domain IDs
+| ${bd_id1}= | 1
+| ${bd_id2}= | 2
+# Traffic profile:
+| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254
+
+*** Keywords ***
+| Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | [Arguments] | ${wt} | ${rxq} | ${framesize} | ${min_rate} | ${search_type}
+| | ...
+| | Set Test Variable | ${framesize}
+| | Set Test Variable | ${min_rate}
+| | ${get_framesize}= | Set Variable If
+| | ... | "${framesize}" == "IMIX_v4_1" | ${avg_imix_framesize}
+| | ... | ${framesize}
+| | ${max_rate}= | Calculate pps | ${s_limit}
+| | ... | ${get_framesize + ${vlan_overhead}}
+| | ${binary_min}= | Set Variable | ${min_rate}
+| | ${binary_max}= | Set Variable | ${max_rate}
+| | ${threshold}= | Set Variable | ${min_rate}
+| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Run Keyword If | ${get_framesize} < ${1522}
+| | ... | Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize L2 bridge domains with VLAN dot1q sub-interfaces in a 3-node circular topology
+| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
+| | Run Keyword If | '${search_type}' == 'NDR'
+| | ... | Find NDR using binary search and pps
+| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ELSE IF | '${search_type}' == 'PDR'
+| | ... | Find PDR using binary search and pps
+| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
+| | ... | ${min_rate} | ${max_rate} | ${threshold}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
+
+*** Test Cases ***
+| tc01-64B-1t1c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps.
+| | ...
+| | [Tags] | 64B | 1T1C | STHREAD | NDRDISC
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=NDR
+
+| tc02-64B-1t1c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps, LT=0.5%.
+| | ...
+| | [Tags] | 64B | 1T1C | STHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=PDR
+
+| tc03-1518B-1t1c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps.
+| | ...
+| | [Tags] | 1518B | 1T1C | STHREAD | NDRDISC
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=NDR
+
+| tc04-1518B-1t1c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps, LT=0.5%.
+| | ...
+| | [Tags] | 1518B | 1T1C | STHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=PDR
+
+| tc05-IMIX-1t1c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 1T1C | STHREAD | NDRDISC
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR
+
+| tc06-IMIX-1t1c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps, LT=0.5%.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 1T1C | STHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=1 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR
+
+| tc07-64B-2t2c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps.
+| | ...
+| | [Tags] | 64B | 2T2C | MTHREAD | NDRDISC
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=NDR
+
+| tc08-64B-2t2c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps, LT=0.5%.
+| | ...
+| | [Tags] | 64B | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=${64} | min_rate=${100000} | search_type=PDR
+
+| tc09-1518B-2t2c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps.
+| | ...
+| | [Tags] | 1518B | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=NDR
+
+| tc10-1518B-2t2c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps, LT=0.5%.
+| | ...
+| | [Tags] | 1518B | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=${1518} | min_rate=${10000} | search_type=PDR
+
+| tc11-IMIX-2t2c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 2T2C | MTHREAD | NDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR
+
+| tc12-IMIX-2t2c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 2T2C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=2 | rxq=1 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR
+
+| tc13-64B-4t4c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps.
+| | ...
+| | [Tags] | 64B | 4T4C | MTHREAD | NDRDISC
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=${64} | min_rate=${100000} | search_type=NDR
+
+| tc14-64B-4t4c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 100kpps, LT=0.5%.
+| | ...
+| | [Tags] | 64B | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=${64} | min_rate=${100000} | search_type=PDR
+
+| tc15-1518B-4t4c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps.
+| | ...
+| | [Tags] | 1518B | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=${1518} | min_rate=${10000} | search_type=NDR
+
+| tc16-1518B-4t4c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
+| | ... | linerate, step 10kpps, LT=0.5%.
+| | ...
+| | [Tags] | 1518B | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=${1518} | min_rate=${10000} | search_type=PDR
+
+| tc17-IMIX-4t4c-dot1q-l2bdbasemaclrn-ndrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 4T4C | MTHREAD | NDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=NDR
+
+| tc18-IMIX-4t4c-dot1q-l2bdbasemaclrn-pdrdisc
+| | [Documentation]
+| | ... | [Cfg] DUT runs L2BD switching config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
+| | ... | 10GE linerate, step 10kpps, LT=0.5%.
+| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
+| | ...
+| | [Tags] | IMIX | 4T4C | MTHREAD | PDRDISC | SKIP_PATCH
+| | ...
+| | [Template] | Discover NDR or PDR for L2 Bridge Domain with VLAN
+| | wt=4 | rxq=2 | framesize=IMIX_v4_1 | min_rate=${10000} | search_type=PDR