diff options
-rw-r--r-- | docs/lab/testbed_specifications.md | 36 |
1 files changed, 23 insertions, 13 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 579ccf4757..2c1cd38636 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -668,7 +668,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. + - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. @@ -688,13 +688,13 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. + - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot10 d8:00.xx: empty. 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - - CIMC and host management ports. + - IPMI and host management ports. - no NIC ports, standalone setup. - Main HW configuration: - Chassis: SuperMicro 1029P-WTRT. @@ -1232,8 +1232,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1264,8 +1266,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1296,8 +1300,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. ``` @@ -1964,9 +1968,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. + - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. - testbed28: - ring1 10GE-ports x710-4p10GE on SUT: - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. @@ -1980,9 +1987,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. + - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. - testbed29: - ring1 10GE-ports x710-4p10GE on SUT: - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. @@ -1996,7 +2006,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. - - ring6 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. ``` |