diff options
-rwxr-xr-x | bootstrap-verify-perf-DPDK.sh | 6 | ||||
-rw-r--r-- | bootstrap-verify-perf-ligato.sh | 6 | ||||
-rwxr-xr-x | bootstrap-verify-perf.sh | 6 | ||||
-rw-r--r-- | resources/topology_schemas/2_node_topology.sch.yaml | 37 | ||||
-rw-r--r-- | topologies/available/3n_hw_testbed1.yaml.example (renamed from topologies/available/3_node_hw_topo1.yaml.example) | 0 | ||||
-rw-r--r-- | topologies/available/lf_2n_skx_testbed21.yaml | 160 | ||||
-rw-r--r-- | topologies/available/lf_2n_skx_testbed22.yaml | 160 | ||||
-rw-r--r-- | topologies/available/lf_2n_skx_testbed23.yaml | 160 | ||||
-rw-r--r-- | topologies/available/lf_2n_skx_testbed24.yaml | 160 | ||||
-rw-r--r-- | topologies/available/lf_3n_hsw_testbed1.yaml (renamed from topologies/available/lf_testbed1.yaml) | 0 | ||||
-rw-r--r-- | topologies/available/lf_3n_hsw_testbed2.yaml (renamed from topologies/available/lf_testbed2.yaml) | 0 | ||||
-rw-r--r-- | topologies/available/lf_3n_hsw_testbed3.yaml (renamed from topologies/available/lf_testbed3.yaml) | 0 | ||||
-rw-r--r-- | topologies/available/lf_3n_skx_testbed31.yaml | 222 |
13 files changed, 908 insertions, 9 deletions
diff --git a/bootstrap-verify-perf-DPDK.sh b/bootstrap-verify-perf-DPDK.sh index f15a38c2f4..defca90797 100755 --- a/bootstrap-verify-perf-DPDK.sh +++ b/bootstrap-verify-perf-DPDK.sh @@ -15,9 +15,9 @@ set -xo pipefail # Space separated list of available testbeds, described by topology files -TOPOLOGIES="topologies/available/lf_testbed1.yaml \ - topologies/available/lf_testbed2.yaml \ - topologies/available/lf_testbed3.yaml" +TOPOLOGIES="topologies/available/lf_3n_hsw_testbed1.yaml \ + topologies/available/lf_3n_hsw_testbed2.yaml \ + topologies/available/lf_3n_hsw_testbed3.yaml" SCRIPT_DIR="$( cd "$( dirname "${BASH_SOURCE[0]}" )" && pwd )" export PYTHONPATH=${SCRIPT_DIR} diff --git a/bootstrap-verify-perf-ligato.sh b/bootstrap-verify-perf-ligato.sh index 0ede5901da..8cbe8ca3a5 100644 --- a/bootstrap-verify-perf-ligato.sh +++ b/bootstrap-verify-perf-ligato.sh @@ -15,9 +15,9 @@ set -xo pipefail # Space separated list of available testbeds, described by topology files -TOPOLOGIES="topologies/available/lf_testbed1.yaml \ - topologies/available/lf_testbed2.yaml \ - topologies/available/lf_testbed3.yaml" +TOPOLOGIES="topologies/available/lf_3n_hsw_testbed1.yaml \ + topologies/available/lf_3n_hsw_testbed2.yaml \ + topologies/available/lf_3n_hsw_testbed3.yaml" SCRIPT_DIR="$( cd "$( dirname "${BASH_SOURCE[0]}" )" && pwd )" export PYTHONPATH=${SCRIPT_DIR} diff --git a/bootstrap-verify-perf.sh b/bootstrap-verify-perf.sh index 5aca852e8f..56e6037090 100755 --- a/bootstrap-verify-perf.sh +++ b/bootstrap-verify-perf.sh @@ -15,9 +15,9 @@ set -xo pipefail # Space separated list of available testbeds, described by topology files -TOPOLOGIES="topologies/available/lf_testbed1.yaml \ - topologies/available/lf_testbed2.yaml \ - topologies/available/lf_testbed3.yaml" +TOPOLOGIES="topologies/available/lf_3n_hsw_testbed1.yaml \ + topologies/available/lf_3n_hsw_testbed2.yaml \ + topologies/available/lf_3n_hsw_testbed3.yaml" SCRIPT_DIR="$( cd "$( dirname "${BASH_SOURCE[0]}" )" && pwd )" export PYTHONPATH=${SCRIPT_DIR} diff --git a/resources/topology_schemas/2_node_topology.sch.yaml b/resources/topology_schemas/2_node_topology.sch.yaml new file mode 100644 index 0000000000..8de397106a --- /dev/null +++ b/resources/topology_schemas/2_node_topology.sch.yaml @@ -0,0 +1,37 @@ +# Copyright (c) 2018 Cisco and/or its affiliates. +# Licensed under the Apache License, Version 2.0 (the "License"); +# you may not use this file except in compliance with the License. +# You may obtain a copy of the License at: +# +# http://www.apache.org/licenses/LICENSE-2.0 +# +# Unless required by applicable law or agreed to in writing, software +# distributed under the License is distributed on an "AS IS" BASIS, +# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. +# See the License for the specific language governing permissions and +# limitations under the License. + +# This file defines required nodes for 2-node topology. + +name: 2_node_topology + +# +------+ +-----+ +# | | port1 port3 | + +# | DUT1 +-----------------+ TG | +# | +-----------------+ + +# | | port2 port4 | | +# +-+-+--+ +-+-+-+ + +type: map +mapping: + metadata: + include: topology_metadata_map + + nodes: + type: map + required: yes + mapping: + TG: + include: type_tg + DUT1: + include: type_dut diff --git a/topologies/available/3_node_hw_topo1.yaml.example b/topologies/available/3n_hw_testbed1.yaml.example index ed817ffb4f..ed817ffb4f 100644 --- a/topologies/available/3_node_hw_topo1.yaml.example +++ b/topologies/available/3n_hw_testbed1.yaml.example diff --git a/topologies/available/lf_2n_skx_testbed21.yaml b/topologies/available/lf_2n_skx_testbed21.yaml new file mode 100644 index 0000000000..d5dc1f50ab --- /dev/null +++ b/topologies/available/lf_2n_skx_testbed21.yaml @@ -0,0 +1,160 @@ +--- +metadata: + version: 0.1 + schema: + - resources/topology_schemas/2_node_topology.sch.yaml + - resources/topology_schemas/topology.sch.yaml + tags: [hw, 2-node] + +nodes: + TG: + type: TG + subtype: TREX + host: "10.30.51.45" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + interfaces: + port1: + # s4-t21-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:70" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.2" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s4-t21-tg1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:71" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.2" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s4-t21-tg1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:72" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.2" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s4-t21-tg1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:73" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.2" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s4-t21-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:fa:38" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.2" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s4-t21-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:fa:39" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.2" + driver: i40e + link: link6 + model: Intel-XXV710 + port7: + # s4-t21-tg1-c10/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:98" + pci_address: "0000:d8:00.0" + ip4_address: "172.16.70.2" + driver: i40e + link: link7 + model: Intel-XL710 + port8: + # s4-t21-tg1-c10/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:99" + pci_address: "0000:d8:00.1" + ip4_address: "172.16.70.1" + driver: i40e + link: link7 + model: Intel-XL710 + port9: + # s4-t21-tg1-c10/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:9a" + pci_address: "0000:d8:00.2" + ip4_address: "172.16.80.2" + driver: i40e + link: link8 + model: Intel-X710 + port10: + # s4-t21-tg1-c10/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:9b" + pci_address: "0000:d8:00.3" + ip4_address: "172.16.80.1" + driver: i40e + link: link8 + model: Intel-X710 + DUT1: + type: DUT + host: "10.30.51.44" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s3-t21-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:88" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.1" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s3-t21-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:89" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.1" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s3-t21-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:8a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.1" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s3-t21-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:8b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.1" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s3-t21-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:60" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.1" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s3-t21-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:61" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.1" + driver: i40e + link: link6 + model: Intel-XXV710 diff --git a/topologies/available/lf_2n_skx_testbed22.yaml b/topologies/available/lf_2n_skx_testbed22.yaml new file mode 100644 index 0000000000..588284c93a --- /dev/null +++ b/topologies/available/lf_2n_skx_testbed22.yaml @@ -0,0 +1,160 @@ +--- +metadata: + version: 0.1 + schema: + - resources/topology_schemas/2_node_topology.sch.yaml + - resources/topology_schemas/topology.sch.yaml + tags: [hw, 2-node] + +nodes: + TG: + type: TG + subtype: TREX + host: "10.30.51.53" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + interfaces: + port1: + # s6-t22-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:98" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.2" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s6-t22-tg1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:99" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.2" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s6-t22-tg1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:9a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.2" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s6-t22-tg1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:9b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.2" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s6-t22-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f8:60" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.2" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s6-t22-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f8:61" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.2" + driver: i40e + link: link6 + model: Intel-XXV710 + port7: + # s6-t22-tg1-c10/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:98" + pci_address: "0000:d8:00.0" + ip4_address: "172.16.70.2" + driver: i40e + link: link7 + model: Intel-XL710 + port8: + # s6-t22-tg1-c10/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:99" + pci_address: "0000:d8:00.1" + ip4_address: "172.16.70.1" + driver: i40e + link: link7 + model: Intel-XL710 + port9: + # s6-t22-tg1-c10/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:9a" + pci_address: "0000:d8:00.2" + ip4_address: "172.16.80.2" + driver: i40e + link: link8 + model: Intel-X710 + port10: + # s6-t22-tg1-c10/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:9b" + pci_address: "0000:d8:00.3" + ip4_address: "172.16.80.1" + driver: i40e + link: link8 + model: Intel-X710 + DUT1: + type: DUT + host: "10.30.51.52" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s5-t22-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:a8" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.1" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s5-t22-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:a9" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.1" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s5-t22-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:aa" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.1" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s5-t22-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:ab" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.1" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s5-t22-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:54" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.1" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s5-t22-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:55" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.1" + driver: i40e + link: link6 + model: Intel-XXV710 diff --git a/topologies/available/lf_2n_skx_testbed23.yaml b/topologies/available/lf_2n_skx_testbed23.yaml new file mode 100644 index 0000000000..d3606e1dde --- /dev/null +++ b/topologies/available/lf_2n_skx_testbed23.yaml @@ -0,0 +1,160 @@ +--- +metadata: + version: 0.1 + schema: + - resources/topology_schemas/2_node_topology.sch.yaml + - resources/topology_schemas/topology.sch.yaml + tags: [hw, 2-node] + +nodes: + TG: + type: TG + subtype: TREX + host: "10.30.51.55" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + interfaces: + port1: + # s8-t23-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:38" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.2" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s8-t23-tg1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:39" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.2" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s8-t23-tg1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:3a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.2" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s8-t23-tg1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:3b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.2" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s8-t23-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:88" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.2" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s8-t23-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:89" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.2" + driver: i40e + link: link6 + model: Intel-XXV710 + port7: + # s8-t23-tg1-c10/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:20" + pci_address: "0000:d8:00.0" + ip4_address: "172.16.70.2" + driver: i40e + link: link7 + model: Intel-XL710 + port8: + # s8-t23-tg1-c10/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:21" + pci_address: "0000:d8:00.1" + ip4_address: "172.16.70.1" + driver: i40e + link: link7 + model: Intel-XL710 + port9: + # s8-t23-tg1-c10/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:22" + pci_address: "0000:d8:00.2" + ip4_address: "172.16.80.2" + driver: i40e + link: link8 + model: Intel-X710 + port10: + # s8-t23-tg1-c10/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ab:23" + pci_address: "0000:d8:00.3" + ip4_address: "172.16.80.1" + driver: i40e + link: link8 + model: Intel-X710 + DUT1: + type: DUT + host: "10.30.51.54" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s7-t23-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:30" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.1" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s7-t23-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:31" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.1" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s7-t23-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:32" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.1" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s7-t23-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:33" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.1" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s7-t23-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:00" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.1" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s7-t23-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:01" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.1" + driver: i40e + link: link6 + model: Intel-XXV710 diff --git a/topologies/available/lf_2n_skx_testbed24.yaml b/topologies/available/lf_2n_skx_testbed24.yaml new file mode 100644 index 0000000000..092104f24f --- /dev/null +++ b/topologies/available/lf_2n_skx_testbed24.yaml @@ -0,0 +1,160 @@ +--- +metadata: + version: 0.1 + schema: + - resources/topology_schemas/2_node_topology.sch.yaml + - resources/topology_schemas/topology.sch.yaml + tags: [hw, 2-node] + +nodes: + TG: + type: TG + subtype: TREX + host: "10.30.51.57" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + interfaces: + port1: + # s10-t24-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:88" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.2" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s10-t24-tg1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:89" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.2" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s10-t24-tg1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:8a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.2" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s10-t24-tg1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:b1:8b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.2" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s10-t24-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:70" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.2" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s10-t24-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:71" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.2" + driver: i40e + link: link6 + model: Intel-XXV710 + port7: + # s10-t24-tg1-c10/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:40" + pci_address: "0000:d8:00.0" + ip4_address: "172.16.70.2" + driver: i40e + link: link7 + model: Intel-XL710 + port8: + # s10-t24-tg1-c10/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:41" + pci_address: "0000:d8:00.1" + ip4_address: "172.16.70.1" + driver: i40e + link: link7 + model: Intel-XL710 + port9: + # s10-t24-tg1-c10/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:42" + pci_address: "0000:d8:00.2" + ip4_address: "172.16.80.2" + driver: i40e + link: link8 + model: Intel-X710 + port10: + # s10-t24-tg1-c10/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ae:43" + pci_address: "0000:d8:00.3" + ip4_address: "172.16.80.1" + driver: i40e + link: link8 + model: Intel-X710 + DUT1: + type: DUT + host: "10.30.51.56" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s9-t24-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:80" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.1" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s9-t24-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:81" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.1" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s9-t24-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:82" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.1" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s9-t24-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:83" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.1" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s9-t24-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:5c" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.1" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s9-t24-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:5d" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.1" + driver: i40e + link: link6 + model: Intel-XXV710 diff --git a/topologies/available/lf_testbed1.yaml b/topologies/available/lf_3n_hsw_testbed1.yaml index fcd9208a38..fcd9208a38 100644 --- a/topologies/available/lf_testbed1.yaml +++ b/topologies/available/lf_3n_hsw_testbed1.yaml diff --git a/topologies/available/lf_testbed2.yaml b/topologies/available/lf_3n_hsw_testbed2.yaml index d69f861969..d69f861969 100644 --- a/topologies/available/lf_testbed2.yaml +++ b/topologies/available/lf_3n_hsw_testbed2.yaml diff --git a/topologies/available/lf_testbed3.yaml b/topologies/available/lf_3n_hsw_testbed3.yaml index e678c87d64..e678c87d64 100644 --- a/topologies/available/lf_testbed3.yaml +++ b/topologies/available/lf_3n_hsw_testbed3.yaml diff --git a/topologies/available/lf_3n_skx_testbed31.yaml b/topologies/available/lf_3n_skx_testbed31.yaml new file mode 100644 index 0000000000..ab40e81f70 --- /dev/null +++ b/topologies/available/lf_3n_skx_testbed31.yaml @@ -0,0 +1,222 @@ +--- +metadata: + version: 0.1 + schema: + - resources/topology_schemas/3_node_topology.sch.yaml + - resources/topology_schemas/topology.sch.yaml + tags: [hw, 3-node] + +nodes: + TG: + type: TG + subtype: TREX + host: "10.30.51.48" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + interfaces: + port1: + # s13-t31-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:58" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.2" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s13-t31-tg1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:59" + pci_address: "0000:18:00.1" + ip4_address: "172.16.20.2" + driver: i40e + link: link2 + model: Intel-XL710 + port3: + # s13-t31-tg1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:5a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.2" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s13-t31-tg1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:5b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.40.2" + driver: i40e + link: link4 + model: Intel-X710 + port5: + # s13-t31-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:40" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.2" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s13-t31-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:41" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.60.2" + driver: i40e + link: link6 + model: Intel-XXV710 + port7: + # s13-t31-tg1-c10/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:30" + pci_address: "0000:d8:00.0" + ip4_address: "172.16.70.2" + driver: i40e + link: link7 + model: Intel-XL710 + port8: + # s13-t31-tg1-c10/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:31" + pci_address: "0000:d8:00.1" + ip4_address: "172.16.70.1" + driver: i40e + link: link7 + model: Intel-XL710 + port9: + # s13-t31-tg1-c10/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:32" + pci_address: "0000:d8:00.2" + ip4_address: "172.16.80.2" + driver: i40e + link: link8 + model: Intel-X710 + port10: + # s13-t31-tg1-c10/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:ad:33" + pci_address: "0000:d8:00.3" + ip4_address: "172.16.80.1" + driver: i40e + link: link8 + model: Intel-X710 + DUT1: + type: DUT + host: "10.30.51.46" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s11-t31-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:38" + pci_address: "0000:18:00.0" + ip4_address: "172.16.10.1" + driver: i40e + link: link1 + model: Intel-XL710 + port2: + # s11-t31-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:39" + pci_address: "0000:18:00.1" + ip4_address: "172.16.120.1" + driver: i40e + link: link21 + model: Intel-XL710 + port3: + # s11-t31-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:3a" + pci_address: "0000:18:00.2" + ip4_address: "172.16.30.1" + driver: i40e + link: link3 + model: Intel-X710 + port4: + # s11-t31-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:af:3b" + pci_address: "0000:18:00.3" + ip4_address: "172.16.140.1" + driver: i40e + link: link22 + model: Intel-X710 + port5: + # s11-t31-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:34" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.50.1" + driver: i40e + link: link5 + model: Intel-XXV710 + port6: + # s11-t31-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:35" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.160.1" + driver: i40e + link: link23 + model: Intel-XXV710 + DUT2: + type: DUT + host: "10.30.51.47" + arch: x86_64 + port: 22 + username: testuser + password: Csit1234 + uio_driver: igb_uio + honeycomb: + user: admin + passwd: admin + port: 8183 + netconf_port: 2831 + interfaces: + port1: + # s12-t31-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:aa:a8" + pci_address: "0000:18:00.0" + ip4_address: "172.16.20.1" + driver: i40e + link: link2 + model: Intel-XL710 + port2: + # s12-t31-sut1-c2/p2 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:aa:a9" + pci_address: "0000:18:00.1" + ip4_address: "172.16.120.2" + driver: i40e + link: link21 + model: Intel-XL710 + port3: + # s12-t31-sut1-c2/p3 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:aa:aa" + pci_address: "0000:18:00.2" + ip4_address: "172.16.40.1" + driver: i40e + link: link4 + model: Intel-X710 + port4: + # s12-t31-sut1-c2/p4 - 10GE port1 on Intel NIC x710 4p10GE. + mac_address: "3c:fd:fe:a8:aa:ab" + pci_address: "0000:18:00.3" + ip4_address: "172.16.140.2" + driver: i40e + link: link22 + model: Intel-X710 + port5: + # s12-t31-sut1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:3c" + pci_address: "0000:3b:00.0" + ip4_address: "172.16.60.1" + driver: i40e + link: link6 + model: Intel-XXV710 + port6: + # s12-t31-sut1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. + mac_address: "3c:fd:fe:bd:f9:3d" + pci_address: "0000:3b:00.1" + ip4_address: "172.16.160.2" + driver: i40e + link: link23 + model: Intel-XXV710 |